Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 3/2008

01.05.2008 | Review

Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?

verfasst von: Fabian Springer, Rolf W. Günther, Thomas Schmitz-Rode

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 3/2008

Einloggen, um Zugang zu erhalten

Abstract

Current protocols for surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms are mostly based on costly and time-consuming imaging procedures and aim to detect adverse events such as graft migration, endoleaks or aneurysm sac enlargement. These imaging procedures are either associated with radiation exposure to the patients or may be harmful to the patient due to the use of iodine- or gadolinium-containing contrast agents. Furthermore the advantages of EVAR in the short term might be negated by the necessity for endograft surveillance over years. Thus, alternative modalities for follow-up are being investigated. One of these technologies provides pressure information directly from the aneurysm sac. This noninvasive, telemetric pressure sensing was tested in vitro as well as in first clinical trials and was able to identify successful aneurysm exclusion after EVAR. The telemetric pressure sensors showed a promising efficacy and accuracy in detecting type I and type III endoleaks and will help to clarify the clinical relevance of type II endoleaks. This article provides an overview of the in vitro sensors investigated as well as the first clinical trials and the sensors’ potential to change the current endograft surveillance regimes.
Literatur
1.
Zurück zum Zitat Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMedCrossRef Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMedCrossRef
2.
Zurück zum Zitat Jordan WD, Alcocer F, Wirthlin DJ, et al. (2003) Abdominal aortic aneurysms in “high-risk” surgical patients: Comparison of open and endovascular repair. Ann Surg 237:623–629; discussion 629–630PubMedCrossRef Jordan WD, Alcocer F, Wirthlin DJ, et al. (2003) Abdominal aortic aneurysms in “high-risk” surgical patients: Comparison of open and endovascular repair. Ann Surg 237:623–629; discussion 629–630PubMedCrossRef
3.
Zurück zum Zitat Golzarian J, Valenti D (2006) Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment. Eur Radiol 16:2849–2857PubMedCrossRef Golzarian J, Valenti D (2006) Endoleakage after endovascular treatment of abdominal aortic aneurysms: Diagnosis, significance and treatment. Eur Radiol 16:2849–2857PubMedCrossRef
4.
Zurück zum Zitat Dubenec SR, White GH, Pasenau J, et al. (2003) Endotension. A review of current views on pathophysiology and treatment. J Cardiovasc Surg (Torino) 44:553–557 Dubenec SR, White GH, Pasenau J, et al. (2003) Endotension. A review of current views on pathophysiology and treatment. J Cardiovasc Surg (Torino) 44:553–557
5.
Zurück zum Zitat Gilling-Smith G, Brennan J, Harris P, et al. (1999) Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 6:305–307PubMedCrossRef Gilling-Smith G, Brennan J, Harris P, et al. (1999) Endotension after endovascular aneurysm repair: Definition, classification, and strategies for surveillance and intervention. J Endovasc Surg 6:305–307PubMedCrossRef
6.
Zurück zum Zitat White GH, May J, Petrasek P, et al. (1999) Endotension: An explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg 6:308–315PubMedCrossRef White GH, May J, Petrasek P, et al. (1999) Endotension: An explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg 6:308–315PubMedCrossRef
7.
Zurück zum Zitat Napoli V, Bargellini I, Sardella SG, et al. (2004) Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMedCrossRef Napoli V, Bargellini I, Sardella SG, et al. (2004) Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMedCrossRef
8.
Zurück zum Zitat d’Audiffret A, Desgranges P, Kobeiter DH, et al. (2001) Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: Validation with computed tomography. J Vasc Surg 33:42–50PubMedCrossRef d’Audiffret A, Desgranges P, Kobeiter DH, et al. (2001) Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: Validation with computed tomography. J Vasc Surg 33:42–50PubMedCrossRef
9.
Zurück zum Zitat Cejna M, Loewe C, Schoder M, et al. (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Eur Radiol 12:2443–2450PubMed Cejna M, Loewe C, Schoder M, et al. (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Eur Radiol 12:2443–2450PubMed
10.
Zurück zum Zitat Haulon S, Lions C, McFadden EP, et al. (2001) Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysms. Eur J Vasc Endovasc Surg 22:62–69PubMedCrossRef Haulon S, Lions C, McFadden EP, et al. (2001) Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysms. Eur J Vasc Endovasc Surg 22:62–69PubMedCrossRef
11.
Zurück zum Zitat Schwope RB, Alper HJ, Talenfeld AD, et al. (2007) MR angiography for patient surveillance after endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 188:W334–340PubMedCrossRef Schwope RB, Alper HJ, Talenfeld AD, et al. (2007) MR angiography for patient surveillance after endovascular repair of abdominal aortic aneurysms. AJR Am J Roentgenol 188:W334–340PubMedCrossRef
12.
Zurück zum Zitat Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am 40:799–833PubMedCrossRef Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am 40:799–833PubMedCrossRef
13.
Zurück zum Zitat Dias NV, Ivancev K, Malina M, et al. (2004) Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. J Vasc Surg 39:1229–1235PubMedCrossRef Dias NV, Ivancev K, Malina M, et al. (2004) Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. J Vasc Surg 39:1229–1235PubMedCrossRef
14.
Zurück zum Zitat Dias NV, Ivancev K, Malina M, et al. (2004) Direct intra-aneurysm sac pressure measurement using tip-pressure sensors: In vivo and in vitro evaluation. J Vasc Surg 40:711–716PubMedCrossRef Dias NV, Ivancev K, Malina M, et al. (2004) Direct intra-aneurysm sac pressure measurement using tip-pressure sensors: In vivo and in vitro evaluation. J Vasc Surg 40:711–716PubMedCrossRef
15.
Zurück zum Zitat Baum RA, Carpenter JP, Cope C, et al. (2001) Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 33:32–41PubMedCrossRef Baum RA, Carpenter JP, Cope C, et al. (2001) Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg 33:32–41PubMedCrossRef
16.
Zurück zum Zitat Sonesson B, Dias N, Malina M, et al. (2003) Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair. J Vasc Surg 37:733–738PubMedCrossRef Sonesson B, Dias N, Malina M, et al. (2003) Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair. J Vasc Surg 37:733–738PubMedCrossRef
17.
Zurück zum Zitat Allen MG (2005) Micromachined endovascularly-implantable wireless aneurysm pressure sensors: from concept to clinic. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Digest of Technical Papers, TRANSDUCERS ‘05:275–278 Allen MG (2005) Micromachined endovascularly-implantable wireless aneurysm pressure sensors: from concept to clinic. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Digest of Technical Papers, TRANSDUCERS ‘05:275–278
18.
Zurück zum Zitat Ohki T, Ouriel K, Silveira PG, et al. (2007) Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial—Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion. J Vasc Surg 45:236–242PubMedCrossRef Ohki T, Ouriel K, Silveira PG, et al. (2007) Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial—Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion. J Vasc Surg 45:236–242PubMedCrossRef
19.
Zurück zum Zitat Ohki T, Yadav J, Gargiulo N, et al. (2003) Preliminary results of an implantable wireless aneurysm pressure sensor in a canine model: Will surveillance CT scan following EVAR become obsolete? J Endovasc Ther 10(Suppl):1–32 Ohki T, Yadav J, Gargiulo N, et al. (2003) Preliminary results of an implantable wireless aneurysm pressure sensor in a canine model: Will surveillance CT scan following EVAR become obsolete? J Endovasc Ther 10(Suppl):1–32
20.
Zurück zum Zitat Chaer RA, Trocciola S, DeRubertis B, et al. (2006) Evaluation of the accuracy of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak and correlation with histologic analysis. J Vasc Surg 44:1306–1313PubMedCrossRef Chaer RA, Trocciola S, DeRubertis B, et al. (2006) Evaluation of the accuracy of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak and correlation with histologic analysis. J Vasc Surg 44:1306–1313PubMedCrossRef
21.
Zurück zum Zitat Milner R, Ruurda JP, Blankensteijn JD (2004) Durability and validity of a remote, miniaturized pressure sensor in an animal model of abdominal aortic aneurysm. J Endovasc Ther 11:372–377PubMedCrossRef Milner R, Ruurda JP, Blankensteijn JD (2004) Durability and validity of a remote, miniaturized pressure sensor in an animal model of abdominal aortic aneurysm. J Endovasc Ther 11:372–377PubMedCrossRef
22.
Zurück zum Zitat Milner R, Verhagen HJ, Prinssen M, et al. (2004) Noninvasive intrasac pressure measurement and the influence of type 2 and type 3 endoleaks in an animal model of abdominal aortic aneurysm. Vascular 12:99–105PubMedCrossRef Milner R, Verhagen HJ, Prinssen M, et al. (2004) Noninvasive intrasac pressure measurement and the influence of type 2 and type 3 endoleaks in an animal model of abdominal aortic aneurysm. Vascular 12:99–105PubMedCrossRef
23.
Zurück zum Zitat Ellozy SH, Carroccio A, Lookstein RA, et al. (2006) Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurement. J Vasc Surg 43:2–7PubMedCrossRef Ellozy SH, Carroccio A, Lookstein RA, et al. (2006) Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurement. J Vasc Surg 43:2–7PubMedCrossRef
24.
Zurück zum Zitat Ellozy SH, Carroccio A, Lookstein RA, et al. (2004) First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg 40:405–412PubMedCrossRef Ellozy SH, Carroccio A, Lookstein RA, et al. (2004) First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg 40:405–412PubMedCrossRef
25.
Zurück zum Zitat Schlierf R, Görtz M, Schmitz-Rode T, et al. (2005) Pressure sensor to control the treatment of abdominal aorta aneurisms. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Digest of Technical Papers, TRANSDUCERS ‘05:1656–1659 Schlierf R, Görtz M, Schmitz-Rode T, et al. (2005) Pressure sensor to control the treatment of abdominal aorta aneurisms. The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, Digest of Technical Papers, TRANSDUCERS ‘05:1656–1659
26.
Zurück zum Zitat Springer F, Schlierf R, Pfeffer JG, et al. (2007) Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: An in vitro study. Eur Radiol 17:2589–2597PubMedCrossRef Springer F, Schlierf R, Pfeffer JG, et al. (2007) Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: An in vitro study. Eur Radiol 17:2589–2597PubMedCrossRef
27.
Zurück zum Zitat Milner R, Kasirajan K, Chaikof EL (2006) Future of endograft surveillance. Semin Vasc Surg 19:75–82PubMedCrossRef Milner R, Kasirajan K, Chaikof EL (2006) Future of endograft surveillance. Semin Vasc Surg 19:75–82PubMedCrossRef
28.
Zurück zum Zitat Carnero L, Milner R (2006) Aneurysm sac pressure measurement with a pressure sensor in endovascular aortic aneurysm repair. Vascular 14:264–269PubMedCrossRef Carnero L, Milner R (2006) Aneurysm sac pressure measurement with a pressure sensor in endovascular aortic aneurysm repair. Vascular 14:264–269PubMedCrossRef
29.
Zurück zum Zitat Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 17:759–764PubMedCrossRef Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 17:759–764PubMedCrossRef
30.
Zurück zum Zitat AbuRahma AF, Welch CA, Mullins BB, et al. (2005) Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther 12:568–573PubMedCrossRef AbuRahma AF, Welch CA, Mullins BB, et al. (2005) Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts. J Endovasc Ther 12:568–573PubMedCrossRef
31.
Zurück zum Zitat Ashoke R, Brown LC, Rodway A, et al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review. J Endovasc Ther 12:297–305PubMedCrossRef Ashoke R, Brown LC, Rodway A, et al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review. J Endovasc Ther 12:297–305PubMedCrossRef
32.
Zurück zum Zitat Henao EA, Hodge MD, Felkai DD, et al. (2006) Contrast-enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: Improved efficacy using a continuous infusion technique. J Vasc Surg 43:259–264; discussion 264PubMedCrossRef Henao EA, Hodge MD, Felkai DD, et al. (2006) Contrast-enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: Improved efficacy using a continuous infusion technique. J Vasc Surg 43:259–264; discussion 264PubMedCrossRef
33.
Zurück zum Zitat Bendick PJ, Zelenock GB, Bove PG, et al. (2003) Duplex ultrasound imaging with an ultrasound contrast agent: The economic alternative to CT angiography for aortic stent graft surveillance. Vasc Endovascular Surg 37:165–170PubMedCrossRef Bendick PJ, Zelenock GB, Bove PG, et al. (2003) Duplex ultrasound imaging with an ultrasound contrast agent: The economic alternative to CT angiography for aortic stent graft surveillance. Vasc Endovascular Surg 37:165–170PubMedCrossRef
34.
Zurück zum Zitat Pitton MB, Schweitzer H, Herber S, et al. (2005) MRI versus helical CT for endoleak detection after endovascular aneurysm repair. AJR Am J Roentgenol 185:1275–1281PubMedCrossRef Pitton MB, Schweitzer H, Herber S, et al. (2005) MRI versus helical CT for endoleak detection after endovascular aneurysm repair. AJR Am J Roentgenol 185:1275–1281PubMedCrossRef
35.
Zurück zum Zitat van der Laan MJ, Bartels LW, Viergever MA, et al. (2006) Computed tomography versus magnetic resonance imaging of endoleaks after EVAR. Eur J Vasc Endovasc Surg 32:361–365PubMedCrossRef van der Laan MJ, Bartels LW, Viergever MA, et al. (2006) Computed tomography versus magnetic resonance imaging of endoleaks after EVAR. Eur J Vasc Endovasc Surg 32:361–365PubMedCrossRef
36.
Zurück zum Zitat Krämer SC, Gorich J, Pamler R, et al. (2002) The contribution of MRI to the detection of endovascular aneurysm repair. Rofo 174:1285–1288PubMed Krämer SC, Gorich J, Pamler R, et al. (2002) The contribution of MRI to the detection of endovascular aneurysm repair. Rofo 174:1285–1288PubMed
37.
Zurück zum Zitat Chewning RH, Murphy KJ (2007) Gadolinium-based Contrast Media and the Development of Nephrogenic Systemic Fibrosis in Patients with Renal Insufficiency. J Vasc Interv Radiol 18:331–333PubMedCrossRef Chewning RH, Murphy KJ (2007) Gadolinium-based Contrast Media and the Development of Nephrogenic Systemic Fibrosis in Patients with Renal Insufficiency. J Vasc Interv Radiol 18:331–333PubMedCrossRef
38.
Zurück zum Zitat High WA, Ayers RA, Chandler J, et al. (2007) Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis. J Am Acad Dermatol 56:21–26PubMedCrossRef High WA, Ayers RA, Chandler J, et al. (2007) Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis. J Am Acad Dermatol 56:21–26PubMedCrossRef
39.
Zurück zum Zitat Khurana A, Runge VM, Narayanan M, et al. (2007) Nephrogenic systemic fibrosis: a review of 6 cases temporally related to gadodiamide injection (Omniscan). Invest Radiol 42:139–145PubMedCrossRef Khurana A, Runge VM, Narayanan M, et al. (2007) Nephrogenic systemic fibrosis: a review of 6 cases temporally related to gadodiamide injection (Omniscan). Invest Radiol 42:139–145PubMedCrossRef
40.
Zurück zum Zitat Pedersen M (2007) Safety update on the possible causal relationship between gadolinium-containing MRI agents and nephrogenic systemic fibrosis. J Magn Reson Imaging 25:881–883PubMedCrossRef Pedersen M (2007) Safety update on the possible causal relationship between gadolinium-containing MRI agents and nephrogenic systemic fibrosis. J Magn Reson Imaging 25:881–883PubMedCrossRef
41.
Zurück zum Zitat Sadowski EA, Bennett LK, Chan MR, et al. (2007) Nephrogenic systemic fibrosis: Risk factors and incidence estimation. Radiology 243:148–157PubMedCrossRef Sadowski EA, Bennett LK, Chan MR, et al. (2007) Nephrogenic systemic fibrosis: Risk factors and incidence estimation. Radiology 243:148–157PubMedCrossRef
42.
Zurück zum Zitat Fonseca MA, Allen M, Kroh J, et al. (2006) Flexible wireless passive pressure sensors for biomedical applications. Solid-State Sensors, Actuators, and Microsystems Workshop, Hilton Head Island, South Carolina, June 4–8, pp 37–42 Fonseca MA, Allen M, Kroh J, et al. (2006) Flexible wireless passive pressure sensors for biomedical applications. Solid-State Sensors, Actuators, and Microsystems Workshop, Hilton Head Island, South Carolina, June 4–8, pp 37–42
Metadaten
Titel
Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?
verfasst von
Fabian Springer
Rolf W. Günther
Thomas Schmitz-Rode
Publikationsdatum
01.05.2008
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 3/2008
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-007-9245-9

Weitere Artikel der Ausgabe 3/2008

CardioVascular and Interventional Radiology 3/2008 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.