Skip to main content
Erschienen in: Neuroradiology 7/2012

01.07.2012 | Interventional Neuroradiology

Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

verfasst von: Marc Saake, Tobias Struffert, Philipp Goelitz, Sabine Ott, Frank Seifert, Oliver Ganslandt, Arnd Doerfler

Erschienen in: Neuroradiology | Ausgabe 7/2012

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina.

Methods

Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion.

Results

Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis.

Conclusions

We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients.
Literatur
1.
Zurück zum Zitat Sadasivan C, Lieber BB, Cesar L, Miskolczi L, Seong J, Wakhloo AK (2006) Angiographic assessment of the performance of flow diverters to treat cerebral aneurysms. Conf Proc IEEE Eng Med Biol Soc 1:3210–3213PubMed Sadasivan C, Lieber BB, Cesar L, Miskolczi L, Seong J, Wakhloo AK (2006) Angiographic assessment of the performance of flow diverters to treat cerebral aneurysms. Conf Proc IEEE Eng Med Biol Soc 1:3210–3213PubMed
2.
Zurück zum Zitat Fiorella D, Hsu D, Woo HH, Tarr RW, Nelson PK (2010) Very late thrombosis of a pipeline embolization device construct: case report. Neurosurgery 67:313–314CrossRef Fiorella D, Hsu D, Woo HH, Tarr RW, Nelson PK (2010) Very late thrombosis of a pipeline embolization device construct: case report. Neurosurgery 67:313–314CrossRef
3.
Zurück zum Zitat Lubicz B, Collignon L, Raphaeli G, Pruvo JP, Bruneau M, De Witte O, Leclerc X (2010) Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 41:2247–2253PubMedCrossRef Lubicz B, Collignon L, Raphaeli G, Pruvo JP, Bruneau M, De Witte O, Leclerc X (2010) Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 41:2247–2253PubMedCrossRef
4.
Zurück zum Zitat Kulcsár Z, Houdart E, Bonafé A, Parker G, Millar J, Goddard AJ, Renowden S, Gál G, Turowski B, Mitchell K, Gray F, Rodriguez M, van den Berg R, Gruber A, Desal H, Wanke I, Rüfenacht DA (2011) Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 32:20–25PubMedCrossRef Kulcsár Z, Houdart E, Bonafé A, Parker G, Millar J, Goddard AJ, Renowden S, Gál G, Turowski B, Mitchell K, Gray F, Rodriguez M, van den Berg R, Gruber A, Desal H, Wanke I, Rüfenacht DA (2011) Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 32:20–25PubMedCrossRef
5.
Zurück zum Zitat Turowski B, Macht S, Kulcsár Z, Hänggi D, Stummer W (2011) Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts? Neuroradiology 53:37–41PubMedCrossRef Turowski B, Macht S, Kulcsár Z, Hänggi D, Stummer W (2011) Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts? Neuroradiology 53:37–41PubMedCrossRef
6.
Zurück zum Zitat Benndorf G, Strother CM, Claus B, Naeini R, Morsi H, Klucznik R, Mawad ME (2005) Angiographic CT in cerebrovascular stenting. AJNR Am J Neuroradiol 26:1813–1818PubMed Benndorf G, Strother CM, Claus B, Naeini R, Morsi H, Klucznik R, Mawad ME (2005) Angiographic CT in cerebrovascular stenting. AJNR Am J Neuroradiol 26:1813–1818PubMed
7.
Zurück zum Zitat Buhk JH, Lingor P, Knauth M (2008) Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting. Neuroradiology 50:349–354PubMedCrossRef Buhk JH, Lingor P, Knauth M (2008) Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting. Neuroradiology 50:349–354PubMedCrossRef
8.
Zurück zum Zitat Struffert T, Ott S, Adamek E, Schwarz M, Engelhorn T, Kloska S, Deuerling-Zheng Y, Doerfler A (2011) Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model. Eur Radiol 21:1779–1787PubMedCrossRef Struffert T, Ott S, Adamek E, Schwarz M, Engelhorn T, Kloska S, Deuerling-Zheng Y, Doerfler A (2011) Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model. Eur Radiol 21:1779–1787PubMedCrossRef
9.
Zurück zum Zitat Struffert T, Kloska S, Engelhorn T, Deuerling-Zheng Y, Ott S, Doelken M, Saake M, Köhrmann M, Doerfler A (2011) Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results. Eur Radiol 21:411–418PubMedCrossRef Struffert T, Kloska S, Engelhorn T, Deuerling-Zheng Y, Ott S, Doelken M, Saake M, Köhrmann M, Doerfler A (2011) Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results. Eur Radiol 21:411–418PubMedCrossRef
10.
Zurück zum Zitat Psychogios MN, Schramm P, Buhk JH, Xyda A, Gröschel K, Jung K, Knauth M (2010) Angiographic CT after intravenous contrast agent application: a noninvasive follow-up tool after intracranial angioplasty and stenting. AJNR Am J Neuroradiol 31:1886–1891PubMedCrossRef Psychogios MN, Schramm P, Buhk JH, Xyda A, Gröschel K, Jung K, Knauth M (2010) Angiographic CT after intravenous contrast agent application: a noninvasive follow-up tool after intracranial angioplasty and stenting. AJNR Am J Neuroradiol 31:1886–1891PubMedCrossRef
11.
Zurück zum Zitat Struffert T, Deuerling-Zheng Y, Kloska S, Engelhorn T, Strother CM, Kalender WA, Köhrmann M, Schwab S, Doerfler A (2010) Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral ischemia. AJNR Am J Neuroradiol 31:1462–1469PubMedCrossRef Struffert T, Deuerling-Zheng Y, Kloska S, Engelhorn T, Strother CM, Kalender WA, Köhrmann M, Schwab S, Doerfler A (2010) Flat detector CT in the evaluation of brain parenchyma, intracranial vasculature, and cerebral blood volume: a pilot study in patients with acute symptoms of cerebral ischemia. AJNR Am J Neuroradiol 31:1462–1469PubMedCrossRef
12.
Zurück zum Zitat Benndorf G, Claus B, Strother CM, Chang L, Klucznik RP (2006) Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: value of angiographic computed tomography: technical case report. Neurosurgery 58:ONS-E380PubMed Benndorf G, Claus B, Strother CM, Chang L, Klucznik RP (2006) Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: value of angiographic computed tomography: technical case report. Neurosurgery 58:ONS-E380PubMed
13.
Zurück zum Zitat Hinkmann FM, Voit HL, Anders K, Baum U, Seidensticker P, Bautz WA, Lell MM (2009) Ultra-fast carotid CT-angiography: low versus standard volume contrast material protocol for a 128-slice CT-system. Invest Radiol 44:257–264PubMedCrossRef Hinkmann FM, Voit HL, Anders K, Baum U, Seidensticker P, Bautz WA, Lell MM (2009) Ultra-fast carotid CT-angiography: low versus standard volume contrast material protocol for a 128-slice CT-system. Invest Radiol 44:257–264PubMedCrossRef
14.
Zurück zum Zitat Kamran M, Yarnold J, Grunwald IQ, Byrne JV (2010) Assessment of angiographic outcomes after flow diversion treatment of intracranial aneurysms: a new grading schema. Neuroradiology 53:501–508PubMedCrossRef Kamran M, Yarnold J, Grunwald IQ, Byrne JV (2010) Assessment of angiographic outcomes after flow diversion treatment of intracranial aneurysms: a new grading schema. Neuroradiology 53:501–508PubMedCrossRef
15.
Zurück zum Zitat Walcott BP, Pisapia JM, Nahed BV, Kahle KT, Ogilvy CS (2011) Early experience with flow diverting endoluminal stents for the treatment of intracranial aneurysms. J Clin Neurosci 18:891–894PubMedCrossRef Walcott BP, Pisapia JM, Nahed BV, Kahle KT, Ogilvy CS (2011) Early experience with flow diverting endoluminal stents for the treatment of intracranial aneurysms. J Clin Neurosci 18:891–894PubMedCrossRef
16.
Zurück zum Zitat Strobel N, Meissner O, Boese J, Brunner T, Heigl B, Hoheisel M, Lauritsch G, Nagel M, Pfister M, Rührnschopf EP, Scholz B, Schreiber B, Spahn M, Zellerhoff M, Klingenbeck-Regn K (2009) 3D Imaging with Flat-Detector C-Arm systems. In: Reiser MF, Becker CR, Nikolaou K, Glazer G (eds) Multislice CT, 3rd edn. Springer, Berlin, pp 33–51CrossRef Strobel N, Meissner O, Boese J, Brunner T, Heigl B, Hoheisel M, Lauritsch G, Nagel M, Pfister M, Rührnschopf EP, Scholz B, Schreiber B, Spahn M, Zellerhoff M, Klingenbeck-Regn K (2009) 3D Imaging with Flat-Detector C-Arm systems. In: Reiser MF, Becker CR, Nikolaou K, Glazer G (eds) Multislice CT, 3rd edn. Springer, Berlin, pp 33–51CrossRef
17.
Zurück zum Zitat Ulzheimer S, Flohr T (2009) Multislice CT: current technology and future developments. In: Reiser MF, Becker CR, Nikolaou K, Glazer G (eds) Multislice CT, 3rd edn. Springer, Berlin, pp 3–23CrossRef Ulzheimer S, Flohr T (2009) Multislice CT: current technology and future developments. In: Reiser MF, Becker CR, Nikolaou K, Glazer G (eds) Multislice CT, 3rd edn. Springer, Berlin, pp 3–23CrossRef
18.
Zurück zum Zitat Trossbach M, Hartmann M, Braun C, Sartor K, Hähnel S (2004) Small vessel stents for intracranial angioplasty: in vitro evaluation of in-stent stenoses using CT angiography. Neuroradiology 46:459–463PubMedCrossRef Trossbach M, Hartmann M, Braun C, Sartor K, Hähnel S (2004) Small vessel stents for intracranial angioplasty: in vitro evaluation of in-stent stenoses using CT angiography. Neuroradiology 46:459–463PubMedCrossRef
19.
Zurück zum Zitat Ionescu M, Metcalfe RW, Cody D, Alvarado MV, Hipp J, Benndorf G (2011) Spatial resolution limits of multislice computed tomography (MS-CT), C-arm-CT, and flat panel-CT (FP-CT) compared to microCT for visualization of a small metallic stent. Acad Radiol 18:866–875PubMedCrossRef Ionescu M, Metcalfe RW, Cody D, Alvarado MV, Hipp J, Benndorf G (2011) Spatial resolution limits of multislice computed tomography (MS-CT), C-arm-CT, and flat panel-CT (FP-CT) compared to microCT for visualization of a small metallic stent. Acad Radiol 18:866–875PubMedCrossRef
20.
Zurück zum Zitat Cohnen M, Wittsack HJ, Assadi S, Muskalla K, Ringelstein A, Poll LW, Saleh A, Mödder U (2006) Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke. AJNR Am J Neuroradiol 27:1741–1745PubMed Cohnen M, Wittsack HJ, Assadi S, Muskalla K, Ringelstein A, Poll LW, Saleh A, Mödder U (2006) Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke. AJNR Am J Neuroradiol 27:1741–1745PubMed
Metadaten
Titel
Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents
verfasst von
Marc Saake
Tobias Struffert
Philipp Goelitz
Sabine Ott
Frank Seifert
Oliver Ganslandt
Arnd Doerfler
Publikationsdatum
01.07.2012
Verlag
Springer-Verlag
Erschienen in
Neuroradiology / Ausgabe 7/2012
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-011-0965-9

Weitere Artikel der Ausgabe 7/2012

Neuroradiology 7/2012 Zur Ausgabe

Interventional Neuroradiology

Medial branch neurotomy in low back pain

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Thrombektomie auch bei großen Infarkten von Vorteil

16.05.2024 Ischämischer Schlaganfall Nachrichten

Auch ein sehr ausgedehnter ischämischer Schlaganfall scheint an sich kein Grund zu sein, von einer mechanischen Thrombektomie abzusehen. Dafür spricht die LASTE-Studie, an der Patienten und Patientinnen mit einem ASPECTS von maximal 5 beteiligt waren.

Schwindelursache: Massagepistole lässt Otholiten tanzen

14.05.2024 Benigner Lagerungsschwindel Nachrichten

Wenn jüngere Menschen über ständig rezidivierenden Lagerungsschwindel klagen, könnte eine Massagepistole der Auslöser sein. In JAMA Otolaryngology warnt ein Team vor der Anwendung hochpotenter Geräte im Bereich des Nackens.

Schützt Olivenöl vor dem Tod durch Demenz?

10.05.2024 Morbus Alzheimer Nachrichten

Konsumieren Menschen täglich 7 Gramm Olivenöl, ist ihr Risiko, an einer Demenz zu sterben, um mehr als ein Viertel reduziert – und dies weitgehend unabhängig von ihrer sonstigen Ernährung. Dafür sprechen Auswertungen zweier großer US-Studien.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.