Benefit of a single recruitment maneuver after an apnea test for the diagnosis of brain death

verfasst von: Marie Paries, Nicolas Boccheciampe, Mathieu Raux, Bruno Riou, Olivier Langeron, Armelle Nicolas-Robin

Erschienen in: Critical Care | Ausgabe 4/2012

Abstract

Introduction

Many potential lung transplants are lost because of hypoxemia during donor management. We hypothesized that the apnea test, necessary to confirm the diagnosis of brain death in potential lung donors, was involved in the decrease in the ratio of partial pressure of arterial O2 to fraction of inspired O2 (PaO2/FiO2) and that a single recruitment maneuver performed just after the apnea test can reverse this alteration.

Methods

In this case-control study, we examined the effectiveness of the recruitment maneuver with a comparison cohort of brain dead patients who did not receive the maneuver. Patients were matched one-to-one on the basis of initial PaO2/FiO2 and on the duration of mechanical ventilation before the apnea test. PaO2/FiO2 was measured before (T1), at the end (T2) and two hours after apnea test (T3).

Results

Twenty-seven patients were included in each group. The apnea test was associated with a significant decrease in PaO2/FiO2 from 284 ± 98 to 224 ± 104 mmHg (P < 0.001). The decrease in PaO2/FiO2 between T1 and T3 was significantly lower in the recruitment maneuver group than in the control group (-4 (-68-57) vs -61 (-110--18) mmHg, P = 0.02). The number of potential donors with PaO2/FiO2 > 300 mmHg decreased by 58% (95% CI: 28-85%) in the control group vs 0% (95% CI: 0-34%) in the recruitment maneuver group (P < 0.001).

Conclusions

The apnea test induced a decrease in PaO2/FiO2 in potential lung donors. A single recruitment maneuver performed immediately after the apnea test can reverse this alteration and may prevent the loss of potential lung donors.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​cc11408) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

NB participated in study design and performed data collection. AN-R, OL, and BR participated in study design. MP performed data collection. MR made computer programs and performed primary data analysis. All authors participated in manuscript preparation and read and approved the final manuscript.
Abkürzungen
CI
confidence interval
FiO2
fractional inspired oxygen
PaO2
arterial oxygen tension
PEEP
positive end-expiratory pressure
RM
recruitment maneuver.

Introduction

Lung transplantation has become a procedure of choice for patients with irreversible, progressively disabling, end-stage pulmonary disease [1]. Among criteria for lung donors, one of the most significant appears to be arterial blood gas analysis before harvest since this parameter has been found to be significantly associated with recipient prognosis [2]. Arterial blood gas standard criteria for lung donors are a ratio of arterial oxygen tension (PaO2) to fractional inspired oxygen (FiO2) of greater than 300 mm Hg and a positive end-expiratory pressure (PEEP) of 5 cm H2O [3]. During the donor management and before organ procurement, many factors may damage the respiratory function of the donor. One of these factors is the apnea test, used to assess the clinical diagnosis of brain death, as a supplement to the absence of motor response to a painful stimulus and to the absence of brainstem reflexes. Usually, the patient has to be disconnected from the mechanical ventilator for 8 to 10 minutes. If there is a partial pressure of arterial carbon dioxide of 60 mm Hg or higher or an increase of more than 20 mm Hg from the baseline value, apnea is confirmed [4]. But apnea is known to be responsible for atelectasis and to decrease PaO2/FiO2 ratio in critically ill ventilated patients [5, 6]. Therefore, the apnea test may possibly contribute to worsening of the respiratory function in potential lung donors.
In normal or morbidly obese patients, recruitment maneuvers (RMs) allow re-opening of atelectasis induced by apnea and paralysis during general anesthesia, through an intentional transient increase in transpulmonary pressure. RMs are associated with a significant increase in oxygenation [7, 8]. Moreover, in potential lung donors, a global protective ventilator strategy that includes small tidal volumes, high PEEP, apnea tests performed without disconnection from the ventilator, and closed circuit for airway suction was recently shown to significantly increase the number of eligible and harvested lungs, although the precise role of each item has not been determined [9]. Thus, we hypothesized that the apnea test used to diagnose brain death could impair gas exchange in potential lung donors and that a single RM performed immediately after could restore it.

Materials and methods

The study was approved by our ethics committee (Comité de Protection des Personnes se prêtant à la RechercheBiomédicale de l'HôpitalPitié-Salpetrière, Paris, France) and was performed in accordance with the Declaration of Helsinki. This study was also conducted in accordance with French law concerning multiple organ procurement. Medical management of patients and diagnosis of brain death were performed as recommended by the French conference of experts in 2005 [10] and by the American Academy of Neurology [11]. Brain death was clinically suspected with usual criteria and had to be confirmed with an apnea test, required for the diagnosis of brain death in France.
The study design was an observational, case controlled study comparing a recent historic cohort of matched control patients with prospectively included treated patients. Before June 2008, the apnea test was performed without any RM. From June 2008, a new protocol was established in our unit, providing a single RM performed immediately after the apnea test administered after the reconnection to the ventilator in potential donors. The RM was the only modification made to our lung management in brain-dead patients between the historical control period and the intervention period.
All patients who required an apnea test to confirm brain death between January 2005 and June 2008 were included in the historic cohort, independently of the criteria for lung donors. Patients were retained if arterial blood gas samples taken 2 hours after the apnea test were available. Blood gas samples were taken at the request of the organ procurement team and not to guide lung management of potential donors. We selected, from among these patients, a matched control group (n = 27, control group). After June 2008 to December 2009, all patients (n = 27, RM group) who required an apnea test to confirm brain death were prospectively included. Patients were excluded only if an apnea test had not been performed or achieved. In this nested case cohort study, patients in the RM group were matched one-to-one on the basis of initial PaO2/FiO2 ratio and mechanical ventilation duration (both identified as putative confounding factors) with patients who were not recruited among the cohort. Matching was performed as follows: For each case, a subset of patients was selected among a historical cohort on the basis of PaO2/FiO2 ratio and mechanical ventilation duration (± 10%). A single patient was subsequently randomly extracted from this subset of matched patients by using a random number table. A flowchart of the study is shown in Figure 1.

Study protocol

All patients received ventilation with tidal volumes of 6 to 10 mL/kg of predicted body weight, PEEP of 5 cm H2O, respiratory rate adjusted to obtain normocapnia, and FiO2 adjusted to obtain a pulse oximetry saturation of greater than 90% (Evita XL; Dräger Medical AG and Co. KGaA, Lübeck, Germany). When required, airway suction was performed with an open circuit. Before the apnea test, the physician checked the absence of confounding variables known to interfere with brain-death diagnosis (low arterial blood pressure, hypothermia, neuromuscular relaxation, and circulating psychoactive drugs). After clinical assessment of unresponsiveness to noxious pain stimuli and abolition of brainstem reflexes, the apnea test was performed as follows: First, FiO2 was increased to 1 for 15 minutes for preoxygenation. At the end of the preoxygenation period, an initial arterial blood sample (T1) was taken. Then, the ventilator was disconnected for 10 minutes and a continuous flow of oxygen at a rate of 6 L/minute was administered to maintain oxygenation. The absence of chest movement indicated a diagnosis of neuronal death in the medulla oblongata. At the end of the test and just before the ventilator was reconnected with the same settings as before the test, a second arterial blood sample (T2) was taken to demonstrate a partial pressure of arterial carbon dioxide of 60 mm Hg or higher or an increase of more than 20 mm Hg from the baseline value.
In the RM group, immediately after reconnection to the ventilator, an RM was performed as follows: First, PEEP was increased from 5 to 35 cm H2O and the respiratory rate was decreased to 0.5 beats per minute for 40 seconds. Next, the initial ventilatory settings were re-applied. Two hours after the reconnection to the ventilator, a third arterial blood sample (T3) was taken. During the RM, we observed hemodynamic effects and oxygen saturation. Hypotension was defined by a diminution of at least 20% of the initial systolic arterial blood pressure, and desaturation was defined by a diminution of oxygen saturation of less than 90%.

Endpoints

The main endpoint was PaO2/FiO2 ratio 2 hours after the apnea test. The secondary endpoints were PaO2/FiO2 ratio evolution during the apnea test, the proportion of potential lung donors in relation to arterial blood gas criteria, and complications of the RM in patients.
Assumptions for the sample size calculation were based on a preliminary study in 36 brain-injured patients. In these patients, we observed that PaO2/FiO2 ratio decreased from 344 ± 116 mm Hg at T1 to 276 ± 124 mm Hg at T2. To test the hypothesis that RMs prevent 80% of the decrease of PaO2/FiO2 ratio measured 2 hours after the apnea test, we calculated that 24 patients per control group or RM group would need to be studied to achieve a statistical power of 80% and an alpha risk of 5%.

Statistical analysis

Data are expressed as mean ± standard deviation or median (25th to 75th interquartiles) for non-normally distributed variables or as number and percentage and its 95% confidence interval (CI). The normality of the distribution of the measured variables was examined with the Shapiro-Wilk test. Comparison between the two groups was performed by using the Student t test, the Mann-Whitney U test, and the Fisher exact method, as appropriate. All P values were two-tailed, and a P value of less than 0.05 was considered significant. Statistical analysis was performed by using Prism 5 software (Software MacKiev Company, Boston, MA, USA).

Results

We prospectively included 27 patients between June 2008 and December 2009, for whom an RM was performed immediately after the apnea test (RM group). From 2005 to June 2008, we retrospectively screened 197 brain-dead patients. Among them, 63 had complete data (that is, a well-conducted apnea test and arterial blood gas taken 2 hours after the apnea test). Among these 63 control patients, 27 were definitively included by matching to the 27 RM patients (Figure 1). Baseline characteristics of the included patients in the control and RM groups are presented in Table 1.
Table 1
Baseline characteristics of patients in the control group and of those in the recruitment maneuver group
 
Control group
(n= 27)
RM group
(n= 27)
P value
Age, years
51 ± 15
55 ± 15
0.35
Cause of brain death
   
   Brain trauma
4 (15%)
8 (22%)
 
   Stroke
18 (67%)
16 (59%)
0.38
   Others
5 (19%)
3 (11%)
 
Sex
   
   Male
19 (70%)
21 (78%)
0.76
   Female
8 (30%)
6 (22%)
 
Weight, kg
76 ± 14
74 ± 13
0.54
Size, cm
173 ± 10
172 ± 9
0.89
Pulmonary disease history
1 (4%)
2 (7%)
1.00
History of smoking
8 (30%)
6 (22%)
0.75
Abnormal chest x-ray
4 (15%)
7 (26%)
0.50
Mean arterial blood pressure, mm Hg
87 ± 10
90 ± 20
0.63
Administration of catecholamine
23 (85%)
24 (89%)
1.00
Ventilatory settings
   
   Tidal volume, mL
525 (500-550)
550 (500-600)
0.30
   Respiratory frequency, per minute
12 (12-14)
12 (10-14)
0.16
   Positive end-expiratory pressure, cm H2O
5 (5-5)
5 (5-5)
0.67
Duration of mechanical ventilation, hours
36 (22-48)
30 (23-48)
0.79
Duration of ventilation of more than 5 days
3 (11%)
4 (15%)
1.00
Data are expressed as mean ± standard deviation (SD), as median (25th to 75th interquartiles), or as number and percentage. RM, recruitment maneuver.
During the apnea test, PaO2/FiO2 ratio decreased significantly from 291 ± 95 mm Hg at T1 to 248 ± 102 mm Hg at T2 in the control group (P < 0.0001) and from 277 ± 101 mm Hg at T1 to 201 ± 103 mm Hg at T2 in the RM group (P < 0.0001). The decrease in PaO2/FiO2 ratio between T1 and T2 was not significantly different between the two groups. After the apnea test, between T2 and T3, PaO2/FiO2 ratio did not significantly change in the control group (from 248 ± 102 to 236 ± 103 mm Hg, P = 0.48). In contrast, in the RM group, PaO2/FiO2 ratio increased significantly (from 201 ± 103 to 283 ± 117 mm Hg, P = 0.009). Consequently, the variation in PaO2/FiO2 ratio between T2 and T3 was significantly greater in the RM group than in the control group (Figure 2a). As a whole, between T1 and T3, the decrease in PaO2/FiO2 ratio was significantly lower in the RM group than in the control group (Figure 2b).
At the same time, the number of potential lung donors with a PaO2/FiO2 ratio of greater than 300 mm Hg decreased. In the whole population (n = 54) and before the apnea test, the number of potential lung donors (with a PaO2/FiO2 ratio of greater than 300 mm Hg) was 21 (39%, 95% CI 26% to 53%): 12 in the control group and 9 in the RM group. Two hours after the apnea test, 7 of the 12 (58%, 95% CI 28% to 85%) potential donors did not meet the criteria any more in the control group as compared with 0 of the 9 (0%, 95% CI 0% to 34%) in the RM group (P = 0.000) (Figure 3).
Complications of RM were studied in the 27 RM potential donors. Hypotension occurred during the RM in 15 cases (55%, 95% CI 37% to 72%), requiring infusion of 500 mL of normal saline in 7 cases. In 5 patients (19%, 95% CI 6% to 38%), this hypotension was resolving after 15 minutes and, in only one patient (3%, 95% CI 1% to 17%), was persistent after 30 minutes. One case (3%, 95% CI 1% to 17%) of desaturation was observed, and no case (0%, 95% CI 0% to 12%) of pneumothorax or bradycardia was observed.

Discussion

Our study showed that the apnea test was associated with a marked decrease in PaO2/FiO2 ratio, which could be restored by an RM performed immediately after the reconnection to the ventilator. Importantly, in relation to arterial blood gas criteria for lung procurement eligibility defined as a PaO2/FiO2 ratio of greater than 300 mm Hg, RM prevented the loss of potential lung donors.
Around the world, there is a persistent and mounting supply-demand discrepancy for lung transplants. Selection criteria were established almost 30 years ago and continue to define the 'standard' lung donor to the present day. The traditional features are age of 55 years or less, clear chest radiography, PaO2/FiO2 ratio of 300 mm Hg or more, tobacco history of not more than 20 packs per year, absence of chest trauma, no evidence of aspiration/sepsis, absence of organisms detected by a sputum Gram stain, absence of purulent secretions at bronchoscopy, and a short period of mechanical ventilation [3, 12]. Historically, the vast majority of organ donors have failed to meet these criteria, leading to lung harvest rates of only 15% to 25%, the lowest rates of all the major transplantable organs [13]. Among them, PaO2/FiO2 ratio is a criterion variably reached in brain-dead patients. In our study, on the basis of arterial blood gas criteria, only 39% of patients were eligible for lung procurement before the apnea test. In the series reported by Mascia and colleagues [9], 54% of lung donors in the control group met a PaO2/FiO2 ratio of greater than 300 mm Hg and a peak airway pressure of less than 30 cm H2O. This difference may be explained because Mascia and colleagues excluded patients who did not meet non-gasometric standard criteria for lung procurement, which are obviously related to PaO2/FiO2 ratio. In our study, patients were older (mean of 53 versus 45 years), the duration of ventilation before the apnea test was greater (mean of 51 versus 36 hours), and the PaO2/FiO2 ratio before the apnea test was lower (mean of 284 versus 396 mm Hg) in comparison with the study by Mascia and colleagues. Moreover, the proportion of patients who had a history of pulmonary disease or an abnormal chest x-ray was 24% in our study whereas these patients were excluded in the study by Mascia and colleagues.
During donor management and before the harvest, many factors may impair the donor's respiratory function: fluid overload, hemodynamic instability, endocrine failure, nephrogenic diabetes insipidus, inflammatory response, arrhythmias, hypothermia, coagulopathy, and infection [14]. Other factors may be atelectasis due to the use of a protective lung strategy and the apnea test, used to assess the clinical diagnosis of brain death [15].
We confirmed the deleterious effect of the apnea test on oxygenation. In our study, the apnea test was responsible for the PaO2/FiO2 ratio decrease from 265 to 225 mm Hg. Because inadequate preoxygenation was found to be associated with hypoxemia during the apnea test, we took care to increase FiO2 to 1 for 15 minutes before the apnea test [16]. Then, we showed that hypoxemia may occur even after adequate preoxygenation. These results are very close to those reported by Goudreau and colleagues [16] during uncomplicated apnea tests, in which the PaO2/FiO2 ratio fell from 248 to 206 mm Hg.
Consequently, two options were available to increase the supply of lungs available for transplantation: to expand the eligibility criteria or to prevent hypoxemia. Some teams have proposed decreasing the minimum tolerated value of PaO2/FiO2 ratio to 225 mm Hg or even removing this criterion in 'marginal' lungs being considered, despite controversies about the consequences [17]. Thabut and colleagues [2], reporting a series of 785 lung donors, demonstrated a higher relative risk of recipient death when donor PaO2/FiO2 ratio fell to below 350 mm Hg. On the other hand, Luckraz and colleagues [18] analyzed 362 lung transplants and found a higher 30-day mortality but not a higher overall mortality in the group of 52 donors with a PaO2/FiO2 ratio of between 225 and 300 mm Hg. More recently, Reyes and colleagues [19] found that 18% of the donors used for transplantation did not meet 'standard' gasometric criteria but that the post-transplant outcomes were similar to those of donors with a PaO2/FiO2 ratio of greater than 300 mm Hg. Nevertheless, it should be a safer strategy to improve the potential lung donors' oxygenation than to expand the criteria of eligibility for procurement.
To improve oxygenation, Noiseux and colleagues [20] proposed a lung recruitment protocol with intermittent 30-second periods of sustained inflation at 30 cm H2O. They reported that, with this protocol, two thirds of the lungs were suitable for transplantation after recruitment. As they did not compare the data with those of donors without a recruitment protocol, the exact benefit of the protocol remains unknown. Recently, Mascia and colleagues [9] showed that a protective ventilatory management of organ donors allowed the number of lung transplantations to be increased. The authors tested a global strategy of optimizing lung function to successfully harvest twice as many lungs according to standard eligibility criteria (including a PaO2/FiO2 ratio of greater than 300 mm Hg). The global strategy included protective ventilation (with tidal volumes of 6 to 8 mL/kg of predicted body weight), PEEP of 8 to 10 cm H2O, an RM performed after any disconnection from the ventilator, an apnea test performed by using continuous positive airway pressure, and a closed circuit for airway suction. Because of global protective respiratory management, it was not possible to ascribe the improvement in respiratory function to a specific modification, especially to RM. Our study was therefore designed to answer this question.
After apnea induced by general anesthesia and paralysis, RMs are effective to re-expand atelectasis and improve oxygenation in healthy subjects [7]. In morbidly obese patients, Reinius and colleagues [21] showed that a single RM followed by PEEP was efficient to reduce the amount of atelectasis and to correct the impairment of oxygenation induced by anesthesia. In brain-dead patients, we have shown that a single RM followed by PEEP might restore oxygenation impaired by an apnea test. Moreover, this strategy may improve the rate of lung procurement. Indeed, in our control group, 58% of the potential lung donors before the apnea test were lost after the apnea test. Conversely, no potential lung donor was lost in the RM group. This result is important since only 39% of our potential donors met the criteria for lung procurement, compared with 95% in the treated group of Mascia and colleagues [9], because of a different selection of potential lung donors (as detailed above).
RMs may have some potential adverse effects. In particular, excessive pressure may cause transient hemodynamic instability, especially in hypovolemic patients [22]. It is known that 80% of brain-dead patients have hemodynamic instability and that many factors may induce real or relative hypovolemia, such as diabetes insipidus, adrenal insufficiency, and sepsis [23]. Despite taking care to correct hypovolemia before an apnea test, we could not prevent all hypotensive episodes. However, these episodes were quickly resolved, either spontaneously or after fluid administration, and no serious complication such as pneumothorax, extreme bradycardia, or cardiac arrest was observed.
Our study had certain limitations that should be noted. The control group was historic. However, randomization was impossible because French law requires informed consent, which is impossible to obtain from brain-dead patients. However, the matching of patients allowed us to have comparable groups, especially under initial pulmonary conditions. In addition, our study included a relatively small number of patients, but the effect of RM, both expected and demonstrated, was so important that the power of the study remained good. Unlike investigators in a study of patients with acute lung injury [24], we did not try to detect atelectasis and effect of RM through computed tomography scans. However, 55% of our patients were hemodynamically unstable, making any move to the radiology unit potentially deleterious. Lastly, the choice of RM technique requires discussion [25, 26]. We chose a sustained high-pressure inflation using a PEEP of 35 cm H2O for a duration of 40 seconds for the sake of simplicity. The PEEP of 35 cm H2O was limited by the settings possible on our ventilator. The choice of this procedure seemed to be the easiest implementation and the most reproducible by all physicians.

Conclusions

Our study showed that the apnea test was associated with impairment in respiratory function in potential organ donors, and this may limit the eligibility for donor lung harvest. A single RM applied just after reconnection to the ventilator prevented the decrease of PaO2/FiO2 ratio and may prevent the loss of potential lung donors. Our study suggests that an RM should be routinely applied after the apnea test in potential lung donors.

Key messages

  • The apnea test, used to assess the clinical diagnosis of brain death, may be associated with impairment in oxygenation in potential organ donors and may limit the eligibility for donor lung harvest.
  • A single recruitment maneuver applied just after reconnection to the ventilator prevents the decrease of PaO2/FiO2 ratio and may prevent the loss of potential lung donors.

Acknowledgements

We thank the team of nurses and the hospital coordinating organ procurement team (Joelle Florit, Viviane Justice, Véronique Kokoszka-Biscompte, and Isabelle Oillic) for their help in this study. We thank David Baker, staff anesthesiologist at the Department of Anesthesiology, CHU Necker-EnfantsMalades, Paris, France, for reviewing the manuscript.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

NB participated in study design and performed data collection. AN-R, OL, and BR participated in study design. MP performed data collection. MR made computer programs and performed primary data analysis. All authors participated in manuscript preparation and read and approved the final manuscript.
Anhänge

Authors’ original submitted files for images

Literatur
2.
Zurück zum Zitat Thabut G, Mal H, Cerrina J, Dartevelle P, Dromer C, Velly J-F, Stern M, Loirat P, Bertocchi M, Mornex J-F, Haloun A, Despins P, Pison C, Blin D, Simonneau G, Reynaud-Gaubert M: Influence of donor characteristics on outcome after lung transplantation: a multicenter study. J Heart Lung Transplant 2005, 24: 1347-1353. 10.1016/j.healun.2004.10.016PubMedCrossRef Thabut G, Mal H, Cerrina J, Dartevelle P, Dromer C, Velly J-F, Stern M, Loirat P, Bertocchi M, Mornex J-F, Haloun A, Despins P, Pison C, Blin D, Simonneau G, Reynaud-Gaubert M: Influence of donor characteristics on outcome after lung transplantation: a multicenter study. J Heart Lung Transplant 2005, 24: 1347-1353. 10.1016/j.healun.2004.10.016PubMedCrossRef
3.
Zurück zum Zitat Snell GI, Westall GP: Selection and management of the lung donor. Clin Chest Med 2011, 32: 223-232. 10.1016/j.ccm.2011.02.002PubMedCrossRef Snell GI, Westall GP: Selection and management of the lung donor. Clin Chest Med 2011, 32: 223-232. 10.1016/j.ccm.2011.02.002PubMedCrossRef
4.
Zurück zum Zitat Wijdicks EF: The diagnosis of brain death. N Engl J Med 2001, 344: 1215-1221. 10.1056/NEJM200104193441606PubMedCrossRef Wijdicks EF: The diagnosis of brain death. N Engl J Med 2001, 344: 1215-1221. 10.1056/NEJM200104193441606PubMedCrossRef
5.
Zurück zum Zitat Strandberg A, Tokics L, Brismar B, Lundquist H, Hedenstierna G: Constitutional factors promoting development of atelectasis during anaesthesia. Acta Anaesthesiol Scand 1987, 31: 21-24. 10.1111/j.1399-6576.1987.tb02513.xPubMedCrossRef Strandberg A, Tokics L, Brismar B, Lundquist H, Hedenstierna G: Constitutional factors promoting development of atelectasis during anaesthesia. Acta Anaesthesiol Scand 1987, 31: 21-24. 10.1111/j.1399-6576.1987.tb02513.xPubMedCrossRef
6.
Zurück zum Zitat Bendixen HH, Hedley-Whyte J, Laver MB: Impaired oxygenation in surgical patients during general anesthesia with controlled ventilation. A concept of atelectasis. N Engl J Med 1963, 269: 991-996. 10.1056/NEJM196311072691901PubMedCrossRef Bendixen HH, Hedley-Whyte J, Laver MB: Impaired oxygenation in surgical patients during general anesthesia with controlled ventilation. A concept of atelectasis. N Engl J Med 1963, 269: 991-996. 10.1056/NEJM196311072691901PubMedCrossRef
7.
Zurück zum Zitat Rothen HU, Sporre B, Engberg G, Wegenius G, Hedenstierna G: Re-expansion of atelectasis during general anaesthesia: a computed tomography study. Br J Anaesth 1993, 71: 788-795. 10.1093/bja/71.6.788PubMedCrossRef Rothen HU, Sporre B, Engberg G, Wegenius G, Hedenstierna G: Re-expansion of atelectasis during general anaesthesia: a computed tomography study. Br J Anaesth 1993, 71: 788-795. 10.1093/bja/71.6.788PubMedCrossRef
8.
Zurück zum Zitat Futier E, Constantin J-M, Pelosi P, Chanques G, Massone A, Petit A, Kwiatkowski F, Bazin J-E, Jaber S: Noninvasive ventilation and alveolar recruitment maneuver improve respiratory function during and after intubation of morbidly obese patients: a randomized controlled study. Anesthesiology 2011, 114: 1354-1363. 10.1097/ALN.0b013e31821811baPubMedCrossRef Futier E, Constantin J-M, Pelosi P, Chanques G, Massone A, Petit A, Kwiatkowski F, Bazin J-E, Jaber S: Noninvasive ventilation and alveolar recruitment maneuver improve respiratory function during and after intubation of morbidly obese patients: a randomized controlled study. Anesthesiology 2011, 114: 1354-1363. 10.1097/ALN.0b013e31821811baPubMedCrossRef
9.
Zurück zum Zitat Mascia L, Pasero D, Arguis MJ, Munari M, Boifava S, Cornara G, Della Corte F, Vivaldi N, Malacarne P, Del Gaudio P, Livigni S, Zavala E, Filippini C, Martin EL, Donadio PP, Mastromauro I, Ranieri VM: Effect of a lung protective strategy for organ donors on eligibility and availability of lungs for transplantation: a randomized controlled trial. JAMA 2010, 304: 2620-2627. 10.1001/jama.2010.1796PubMedCrossRef Mascia L, Pasero D, Arguis MJ, Munari M, Boifava S, Cornara G, Della Corte F, Vivaldi N, Malacarne P, Del Gaudio P, Livigni S, Zavala E, Filippini C, Martin EL, Donadio PP, Mastromauro I, Ranieri VM: Effect of a lung protective strategy for organ donors on eligibility and availability of lungs for transplantation: a randomized controlled trial. JAMA 2010, 304: 2620-2627. 10.1001/jama.2010.1796PubMedCrossRef
10.
Zurück zum Zitat Boulard G, Guiot P, Pottecher T, Tenaillon A: Management of subjects in a state of brain death and the preservation of organs. Ann Fr Anesth Reanim 2005, 24: 836-43. 10.1016/j.annfar.2005.05.020PubMedCrossRef Boulard G, Guiot P, Pottecher T, Tenaillon A: Management of subjects in a state of brain death and the preservation of organs. Ann Fr Anesth Reanim 2005, 24: 836-43. 10.1016/j.annfar.2005.05.020PubMedCrossRef
11.
Zurück zum Zitat Practice parameters for determining brain death in adults (summary statement). The Quality Standards Subcommittee of the American Academy of Neurology Neurology 1995, 45: 1012-1014. Practice parameters for determining brain death in adults (summary statement). The Quality Standards Subcommittee of the American Academy of Neurology Neurology 1995, 45: 1012-1014.
12.
Zurück zum Zitat Riou B, Guesde R, Jacquens Y, Duranteau R, Viars P: Fiberoptic bronchoscopy in brain-dead organ donors. Am J Respir Crit Care Med 1994, 150: 558-560.PubMedCrossRef Riou B, Guesde R, Jacquens Y, Duranteau R, Viars P: Fiberoptic bronchoscopy in brain-dead organ donors. Am J Respir Crit Care Med 1994, 150: 558-560.PubMedCrossRef
13.
Zurück zum Zitat Kotloff RM, Thabut G: Lung transplantation. Am J Respir Crit Care Med 2011, 184: 159-171. 10.1164/rccm.201101-0134CIPubMedCrossRef Kotloff RM, Thabut G: Lung transplantation. Am J Respir Crit Care Med 2011, 184: 159-171. 10.1164/rccm.201101-0134CIPubMedCrossRef
14.
Zurück zum Zitat de Perrot M, Snell GI, Babcock WD, Meyers BF, Patterson G, Hodges TN, Keshavjee S: Strategies to optimize the use of currently available lung donors. J Heart Lung Transplant 2004, 23: 1127-1134. 10.1016/j.healun.2003.09.010PubMedCrossRef de Perrot M, Snell GI, Babcock WD, Meyers BF, Patterson G, Hodges TN, Keshavjee S: Strategies to optimize the use of currently available lung donors. J Heart Lung Transplant 2004, 23: 1127-1134. 10.1016/j.healun.2003.09.010PubMedCrossRef
15.
Zurück zum Zitat Richard JC, Maggiore SM, Jonson B, Mancebo J, Lemaire F, Brochard L: Influence of tidal volume on alveolar recruitment. Respective role of PEEP and a recruitment maneuver. Am J Respir Crit Care Med 2001, 163: 1609-1613.PubMedCrossRef Richard JC, Maggiore SM, Jonson B, Mancebo J, Lemaire F, Brochard L: Influence of tidal volume on alveolar recruitment. Respective role of PEEP and a recruitment maneuver. Am J Respir Crit Care Med 2001, 163: 1609-1613.PubMedCrossRef
16.
Zurück zum Zitat Goudreau JL, Wijdicks EF, Emery SF: Complications during apnea testing in the determination of brain death: predisposing factors. Neurology 2000, 55: 1045-1048. 10.1212/WNL.55.7.1045PubMedCrossRef Goudreau JL, Wijdicks EF, Emery SF: Complications during apnea testing in the determination of brain death: predisposing factors. Neurology 2000, 55: 1045-1048. 10.1212/WNL.55.7.1045PubMedCrossRef
17.
Zurück zum Zitat Botha P, Fisher AJ, Dark JH: Marginal lung donors: a diminishing margin of safety? Transplantation 2006, 82: 1273-1279. 10.1097/01.tp.0000236099.52382.74PubMedCrossRef Botha P, Fisher AJ, Dark JH: Marginal lung donors: a diminishing margin of safety? Transplantation 2006, 82: 1273-1279. 10.1097/01.tp.0000236099.52382.74PubMedCrossRef
18.
Zurück zum Zitat Luckraz H, White P, Sharples LD, Hopkins P, Wallwork J: Short- and long-term outcomes of using pulmonary allograft donors with low Po2. J Heart Lung Transplant 2005, 24: 470-473. 10.1016/j.healun.2004.02.012PubMedCrossRef Luckraz H, White P, Sharples LD, Hopkins P, Wallwork J: Short- and long-term outcomes of using pulmonary allograft donors with low Po2. J Heart Lung Transplant 2005, 24: 470-473. 10.1016/j.healun.2004.02.012PubMedCrossRef
19.
Zurück zum Zitat Reyes KG, Mason DP, Thuita L, Nowicki ER, Murthy SC, Pettersson GB, Blackstone EH: Guidelines for donor lung selection: time for revision? Ann Thorac Surg 2010, 89: 1756-1764; discussion 1764-1765. 10.1016/j.athoracsur.2010.02.056PubMedCrossRef Reyes KG, Mason DP, Thuita L, Nowicki ER, Murthy SC, Pettersson GB, Blackstone EH: Guidelines for donor lung selection: time for revision? Ann Thorac Surg 2010, 89: 1756-1764; discussion 1764-1765. 10.1016/j.athoracsur.2010.02.056PubMedCrossRef
20.
Zurück zum Zitat Noiseux N, Nguyen BK, Marsolais P, Dupont J, Simard L, Houde I, Lallier M, Langevin S, Cantin B, Ferraro P: Pulmonary recruitment protocol for organ donors: a new strategy to improve the rate of lung utilization. Transplant Proc 2009, 41: 3284-3289. 10.1016/j.transproceed.2009.08.041PubMedCrossRef Noiseux N, Nguyen BK, Marsolais P, Dupont J, Simard L, Houde I, Lallier M, Langevin S, Cantin B, Ferraro P: Pulmonary recruitment protocol for organ donors: a new strategy to improve the rate of lung utilization. Transplant Proc 2009, 41: 3284-3289. 10.1016/j.transproceed.2009.08.041PubMedCrossRef
21.
Zurück zum Zitat Reinius H, Jonsson L, Gustafsson S, Sundbom M, Duvernoy O, Pelosi P, Hedenstierna G, Fredén F: Prevention of atelectasis in morbidly obese patients during general anesthesia and paralysis: a computerized tomography study. Anesthesiology 2009, 111: 979-987. 10.1097/ALN.0b013e3181b87edbPubMedCrossRef Reinius H, Jonsson L, Gustafsson S, Sundbom M, Duvernoy O, Pelosi P, Hedenstierna G, Fredén F: Prevention of atelectasis in morbidly obese patients during general anesthesia and paralysis: a computerized tomography study. Anesthesiology 2009, 111: 979-987. 10.1097/ALN.0b013e3181b87edbPubMedCrossRef
22.
Zurück zum Zitat Bohm SH, Thamm OC, von Sandersleben A, Bangert K, Langwieler TE, Tusman G, Strate TG, Standl TG: Alveolar recruitment strategy and high positive end-expiratory pressure levels do not affect hemodynamics in morbidly obese intravascular volume-loaded patients. Anesth Analg 2009, 109: 160-163. 10.1213/ane.0b013e3181a801a3PubMedCrossRef Bohm SH, Thamm OC, von Sandersleben A, Bangert K, Langwieler TE, Tusman G, Strate TG, Standl TG: Alveolar recruitment strategy and high positive end-expiratory pressure levels do not affect hemodynamics in morbidly obese intravascular volume-loaded patients. Anesth Analg 2009, 109: 160-163. 10.1213/ane.0b013e3181a801a3PubMedCrossRef
23.
Zurück zum Zitat Salim A, Martin M, Brown C, Rhee P, Demetriades D, Belzberg H: The effect of a protocol of aggressive donor management: implications for the national organ donor shortage. J Trauma 2006, 61: 429-433; discussion 433-435. 10.1097/01.ta.0000228968.63652.c1PubMedCrossRef Salim A, Martin M, Brown C, Rhee P, Demetriades D, Belzberg H: The effect of a protocol of aggressive donor management: implications for the national organ donor shortage. J Trauma 2006, 61: 429-433; discussion 433-435. 10.1097/01.ta.0000228968.63652.c1PubMedCrossRef
24.
Zurück zum Zitat Constantin J-M, Grasso S, Chanques G, Aufort S, Futier E, Sebbane M, Jung B, Gallix B, Bazin JE, Rouby J-J, Jaber S: Lung morphology predicts response to recruitment maneuver in patients with acute respiratory distress syndrome. Crit Care Med 2010, 38: 1108-1117. 10.1097/CCM.0b013e3181d451ecPubMedCrossRef Constantin J-M, Grasso S, Chanques G, Aufort S, Futier E, Sebbane M, Jung B, Gallix B, Bazin JE, Rouby J-J, Jaber S: Lung morphology predicts response to recruitment maneuver in patients with acute respiratory distress syndrome. Crit Care Med 2010, 38: 1108-1117. 10.1097/CCM.0b013e3181d451ecPubMedCrossRef
25.
Zurück zum Zitat Chacko J, Rani U: Alveolar recruitment maneuvers in acute lung injury/acute respiratory distress syndrome. Indian J Crit Care Med 2009, 13: 1-6. 10.4103/0972-5229.53107PubMedPubMedCentralCrossRef Chacko J, Rani U: Alveolar recruitment maneuvers in acute lung injury/acute respiratory distress syndrome. Indian J Crit Care Med 2009, 13: 1-6. 10.4103/0972-5229.53107PubMedPubMedCentralCrossRef
Metadaten
Titel
Benefit of a single recruitment maneuver after an apnea test for the diagnosis of brain death
verfasst von
Marie Paries
Nicolas Boccheciampe
Mathieu Raux
Bruno Riou
Olivier Langeron
Armelle Nicolas-Robin
Publikationsdatum
01.08.2012
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 4/2012
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc11408

Weitere Artikel der Ausgabe 4/2012

Critical Care 4/2012 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.