Skip to main content
Erschienen in: Journal of Anesthesia 6/2018

05.10.2018 | Original Article

Bite injuries caused by transcranial electrical stimulation motor-evoked potentials’ monitoring: incidence, associated factors, and clinical course

verfasst von: Sachiko Yata, Mitsuru Ida, Hiroko Shimotsuji, Yosuke Nakagawa, Nobuhiro Ueda, Tsunenori Takatani, Hideki Shigematsu, Yasushi Motoyama, Hiroyuki Nakase, Tadaaki Kirita, Masahiko Kawaguchi

Erschienen in: Journal of Anesthesia | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The incidence of bite injuries associated with transcranial electrical stimulation motor-evoked potentials monitoring reportedly ranges from 0.13 to 0.19%. However, in clinical practice, bite injuries appear to occur more frequently than previously reported. Our aim was to identify the incidence of and perioperative risk factors associated with bite injuries caused by transcranial electrical stimulation motor-evoked potential monitoring.

Methods

Patients who underwent elective surgery with transcranial electrical stimulation motor-evoked potential monitoring at a single tertiary hospital in Japan between June 2017 and December 2017 were included in this study. All patients were assessed by oral surgeons preoperatively and postoperatively. The associated factors with bite injuries were explored by the univariate analysis.

Results

12 of 186 patients experienced 13 bite injuries, including three lip, six oral mucosa, and four tongue injuries. No patient required suture repair. 11 of 12 patients had uneventful postoperative courses and were cured within 12 postoperative days. One patient with a tongue ulcer and a hematoma had difficulty in oral intake and persistent dysgeusia. Patient severe movement during transcranial electrical stimulation motor-evoked potential monitoring was associated with bite injuries (p = 0.03).

Conclusions

The incidence of bite injuries assessed by oral surgeons was 6.5% in patients with transcranial electrical stimulation motor-evoked potential monitoring, and the patients with severe movement during the monitoring tended to incur bite injuries. In rare cases, transcranial electrical stimulation motor-evoked potential monitoring may cause difficulty in oral intake and dysgeusia.
Literatur
1.
Zurück zum Zitat Deletis V, Sala F. Intraoperative neurophysiological monitoring of the spinal cord during spinal cord and spine surgery: a review focus on the corticospinal tracts. Clin Neurophysiol. 2008;119:248–64.CrossRef Deletis V, Sala F. Intraoperative neurophysiological monitoring of the spinal cord during spinal cord and spine surgery: a review focus on the corticospinal tracts. Clin Neurophysiol. 2008;119:248–64.CrossRef
2.
Zurück zum Zitat Motoyama Y, Kawaguchi M, Yamada S, Nakagawa I, Nishimura F, Hironaka Y, Park YS, Hayashi H, Abe R, Nakase H. Evaluation of combined use of transcranial and direct cortical motor evoked potential monitoring during unruptured aneurysm surgery. Neurol Med Chir (Tokyo). 2011;51:15–22.CrossRef Motoyama Y, Kawaguchi M, Yamada S, Nakagawa I, Nishimura F, Hironaka Y, Park YS, Hayashi H, Abe R, Nakase H. Evaluation of combined use of transcranial and direct cortical motor evoked potential monitoring during unruptured aneurysm surgery. Neurol Med Chir (Tokyo). 2011;51:15–22.CrossRef
3.
Zurück zum Zitat MacDonald DB. Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring. J Clin Neurophysiol. 2002;19:416–29.CrossRef MacDonald DB. Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring. J Clin Neurophysiol. 2002;19:416–29.CrossRef
4.
Zurück zum Zitat Tamkus A, Rice K. The incidence of bite injuries associated with transcranial motor-evoked potential monitoring. Anesth Analg. 2012;115:663–7.PubMed Tamkus A, Rice K. The incidence of bite injuries associated with transcranial motor-evoked potential monitoring. Anesth Analg. 2012;115:663–7.PubMed
5.
Zurück zum Zitat Schwartz DM, Sestokas AK, Dormans JP, Vaccaro AR, Hilibrand AS, Flynn JM, Li PM, Shah SA, Welch W, Drummond DS, Albert TJ. Transcranial motor evoked potential monitoring in spine surgery: is it safe? Spine. 2011;36:1046–9.CrossRef Schwartz DM, Sestokas AK, Dormans JP, Vaccaro AR, Hilibrand AS, Flynn JM, Li PM, Shah SA, Welch W, Drummond DS, Albert TJ. Transcranial motor evoked potential monitoring in spine surgery: is it safe? Spine. 2011;36:1046–9.CrossRef
6.
Zurück zum Zitat Kakimoto M, Kawaguchi M, Yamamoto Y, Inoue S, Horiuchi T, Nakase H, Sakaki T, Furuya H. Tetanic stimulation of the peripheral nerve before transcranial electrical stimulation can enlarge general anesthesia with neuromuscular blockade. Anesthesiology. 2005;102:733–8.CrossRef Kakimoto M, Kawaguchi M, Yamamoto Y, Inoue S, Horiuchi T, Nakase H, Sakaki T, Furuya H. Tetanic stimulation of the peripheral nerve before transcranial electrical stimulation can enlarge general anesthesia with neuromuscular blockade. Anesthesiology. 2005;102:733–8.CrossRef
7.
Zurück zum Zitat Yamamoto Y, Kawaguchi M, Hayashi H, Horiuchi T, Inoue S, Nakase H, Sakaki T, Furuya H. The effects of the neuromuscular blockade levels on amplitudes of posttetanic motor-evoked potentials and movement in response to transcranial stimulation in patients receiving propofol and fentanyl anesthesia. Anesth Analg. 2008;106:930–4.CrossRef Yamamoto Y, Kawaguchi M, Hayashi H, Horiuchi T, Inoue S, Nakase H, Sakaki T, Furuya H. The effects of the neuromuscular blockade levels on amplitudes of posttetanic motor-evoked potentials and movement in response to transcranial stimulation in patients receiving propofol and fentanyl anesthesia. Anesth Analg. 2008;106:930–4.CrossRef
8.
Zurück zum Zitat Mahmoud M, Spaeth J, Sadhasivam S. Protection of tongue from injuries during transcranial motor-evoked potential monitoring. Paediatr Anaesth. 2008;18:902–3.CrossRef Mahmoud M, Spaeth J, Sadhasivam S. Protection of tongue from injuries during transcranial motor-evoked potential monitoring. Paediatr Anaesth. 2008;18:902–3.CrossRef
9.
Zurück zum Zitat Oshita K, Saeki N, Kubo T, Abekura H, Tanaka N, Kawamoto M. A novel mouthpiece prevents bite injuries caused by intraoperative transcranial electric motor-evoked potential monitoring. J Anesth. 2016;30:850–4.CrossRef Oshita K, Saeki N, Kubo T, Abekura H, Tanaka N, Kawamoto M. A novel mouthpiece prevents bite injuries caused by intraoperative transcranial electric motor-evoked potential monitoring. J Anesth. 2016;30:850–4.CrossRef
Metadaten
Titel
Bite injuries caused by transcranial electrical stimulation motor-evoked potentials’ monitoring: incidence, associated factors, and clinical course
verfasst von
Sachiko Yata
Mitsuru Ida
Hiroko Shimotsuji
Yosuke Nakagawa
Nobuhiro Ueda
Tsunenori Takatani
Hideki Shigematsu
Yasushi Motoyama
Hiroyuki Nakase
Tadaaki Kirita
Masahiko Kawaguchi
Publikationsdatum
05.10.2018
Verlag
Springer Japan
Erschienen in
Journal of Anesthesia / Ausgabe 6/2018
Print ISSN: 0913-8668
Elektronische ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-018-2562-0

Weitere Artikel der Ausgabe 6/2018

Journal of Anesthesia 6/2018 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Häufigste Gründe für Brustschmerzen bei Kindern

06.05.2024 Pädiatrische Diagnostik Nachrichten

Akute Brustschmerzen sind ein Alarmsymptom par exellence, schließlich sind manche Auslöser lebensbedrohlich. Auch Kinder klagen oft über Schmerzen in der Brust. Ein Studienteam ist den Ursachen nachgegangen.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.