Blood viscometer applying electromagnetically spinning method

verfasst von: Kazuyoshi Fukunaga, Masaya Onuki, Yoshinori Ohtsuka, Taichi Hirano, Keiji Sakai, Yasuharu Ohgoe, Ayako Katoh, Toshiyuki Yaguchi, Akio Funakubo, Yasuhiro Fukui

Erschienen in: Journal of Artificial Organs | Ausgabe 3/2013

Einloggen, um Zugang zu erhalten

Abstract

Viscosity is an important parameter which affects hemodynamics during extracorporeal circulation and long-term cardiac support. In this study, we have aimed to develop a novel viscometer with which we can easily measure blood viscosity by applying the electromagnetically spinning (EMS) method. In the EMS method, we can rotate an aluminum ball 2 mm in diameter indirectly in a test tube with 0.3 ml sample of a liquid by utilizing the moment caused by the Lorentz force as well as separate the test tube from the viscometer body. First, we calibrated the EMS viscometer by means of liquid samples with known viscosities and computational fluid dynamics. Then, when we measured the viscosity of 9.4 mPa s silicone oil in order to evaluate the performance of the EMS viscometer, the mean viscosity was found to be 9.55 ± 0.10 mPa s at available shear rates from 10 to 240 s−1. Finally, we measured the viscosity of bovine blood. We prepared four blood samples whose hematocrit levels were adjusted to 23, 45, 50, and 70 % and a plasma sample without hemocyte components. As a result, the measurements of blood viscosities showed obedience to Casson’s equation. We found that the viscosity was approximately constant in Newtonian silicone oil, whereas the viscosity decreased with increasing shear rate in non-Newtonian bovine blood. These results suggest that the EMS viscometer will be useful to measure blood viscosity at the clinical site.
Literatur
1.
Zurück zum Zitat Yarnell WG, Baker PM, Sweetnam PM, Bainton D, O’Brien JR, Whitehead PJ, Elwood PC. Fibrinogen, viscosity, and white blood cell count are major risk factors for ischemic heart disease. The Caerphilly and Speedwell collaborative heart disease studies. Circulation. 2001;83:836–44.CrossRef Yarnell WG, Baker PM, Sweetnam PM, Bainton D, O’Brien JR, Whitehead PJ, Elwood PC. Fibrinogen, viscosity, and white blood cell count are major risk factors for ischemic heart disease. The Caerphilly and Speedwell collaborative heart disease studies. Circulation. 2001;83:836–44.CrossRef
2.
Zurück zum Zitat Shinmyozu K, Hashiguchi K, Maruyama I, Igata A, Ohkatsu Y. Studies on the parameters of blood viscosity and platelet function in patients with transient ischemic attack. Jpn J Stoke. 1983;5:12–9 (in Japanese).CrossRef Shinmyozu K, Hashiguchi K, Maruyama I, Igata A, Ohkatsu Y. Studies on the parameters of blood viscosity and platelet function in patients with transient ischemic attack. Jpn J Stoke. 1983;5:12–9 (in Japanese).CrossRef
3.
Zurück zum Zitat Zimm BH, Crothers DM. Simplified rotating cylinder viscometer for DNA. Proc Natl Acad Sci USA. 1962;48:905–11.PubMedCrossRef Zimm BH, Crothers DM. Simplified rotating cylinder viscometer for DNA. Proc Natl Acad Sci USA. 1962;48:905–11.PubMedCrossRef
4.
Zurück zum Zitat Martin JL, Sinusas R, Jacobs RM, Copley AL. Transistorized falling ball viscometer for rapid testing of biological and technological system. Biorheology. 1974;11:449–52.PubMed Martin JL, Sinusas R, Jacobs RM, Copley AL. Transistorized falling ball viscometer for rapid testing of biological and technological system. Biorheology. 1974;11:449–52.PubMed
5.
Zurück zum Zitat Harwood CF, Pilpel N. Rotational viscometer for powders and granules. Lab Pract. 1968;17:1236–8.PubMed Harwood CF, Pilpel N. Rotational viscometer for powders and granules. Lab Pract. 1968;17:1236–8.PubMed
6.
Zurück zum Zitat Alexy T, Pais E, Wenby RB, Hogenauer W, Toth K, Meiselman HJ, Kensey KR. Measurement of whole blood viscosity profiles via an automated viscometer : technical details and clinical relevance. Clin Lab. 2005;51:523–9.PubMed Alexy T, Pais E, Wenby RB, Hogenauer W, Toth K, Meiselman HJ, Kensey KR. Measurement of whole blood viscosity profiles via an automated viscometer : technical details and clinical relevance. Clin Lab. 2005;51:523–9.PubMed
7.
Zurück zum Zitat Eguchi Y, Karino T. Measurement of rheologic property of blood by a falling-ball blood viscometer. Ann Biomed Eng. 2008;36:543–53.CrossRef Eguchi Y, Karino T. Measurement of rheologic property of blood by a falling-ball blood viscometer. Ann Biomed Eng. 2008;36:543–53.CrossRef
8.
Zurück zum Zitat Sakai K, Hirano T, Hosoda M. Electromagnetically spinning sphere viscometer. Jpn J Appl Phys. 2010;3:016602. Sakai K, Hirano T, Hosoda M. Electromagnetically spinning sphere viscometer. Jpn J Appl Phys. 2010;3:016602.
9.
Zurück zum Zitat Yasuda M, Kurauchi N, Nakamura M, Hirano T, Sakai K. Application of electro-magnetically spinning sphere viscometer for variety of viscosity measurement. J Soc Rheol Jpn. 2011;39:29–35 (in Japanese).CrossRef Yasuda M, Kurauchi N, Nakamura M, Hirano T, Sakai K. Application of electro-magnetically spinning sphere viscometer for variety of viscosity measurement. J Soc Rheol Jpn. 2011;39:29–35 (in Japanese).CrossRef
10.
Zurück zum Zitat Scott Blair GW. An equation for the flow of blood, plasma and serum through glass capillaries. Nature. 1959;183:613–4.CrossRef Scott Blair GW. An equation for the flow of blood, plasma and serum through glass capillaries. Nature. 1959;183:613–4.CrossRef
11.
Zurück zum Zitat Copley AL, Scott Blair GW, Glover FA, Thorley RS. Capillary flow and wall adherence of bovine blood, plasma and serum in contact with glass and fibrin surfaces. Kolloid-Zeitschrift. 1960;168:101–7.CrossRef Copley AL, Scott Blair GW, Glover FA, Thorley RS. Capillary flow and wall adherence of bovine blood, plasma and serum in contact with glass and fibrin surfaces. Kolloid-Zeitschrift. 1960;168:101–7.CrossRef
12.
Zurück zum Zitat Wells RE, Merrill EW. Influence of flow properties of blood upon viscosity-hematocrit relationships. J Clin Invest. 1962;41:1591–8.PubMedCrossRef Wells RE, Merrill EW. Influence of flow properties of blood upon viscosity-hematocrit relationships. J Clin Invest. 1962;41:1591–8.PubMedCrossRef
Metadaten
Titel
Blood viscometer applying electromagnetically spinning method
verfasst von
Kazuyoshi Fukunaga
Masaya Onuki
Yoshinori Ohtsuka
Taichi Hirano
Keiji Sakai
Yasuharu Ohgoe
Ayako Katoh
Toshiyuki Yaguchi
Akio Funakubo
Yasuhiro Fukui
Publikationsdatum
01.09.2013
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 3/2013
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-013-0707-3

Weitere Artikel der Ausgabe 3/2013

Journal of Artificial Organs 3/2013 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Deutlich weniger Infektionen: Wundprotektoren schützen!

08.05.2024 Postoperative Wundinfektion Nachrichten

Der Einsatz von Wundprotektoren bei offenen Eingriffen am unteren Gastrointestinaltrakt schützt vor Infektionen im Op.-Gebiet – und dient darüber hinaus der besseren Sicht. Das bestätigt mit großer Robustheit eine randomisierte Studie im Fachblatt JAMA Surgery.

Chirurginnen und Chirurgen sind stark suizidgefährdet

07.05.2024 Suizid Nachrichten

Der belastende Arbeitsalltag wirkt sich negativ auf die psychische Gesundheit der Angehörigen ärztlicher Berufsgruppen aus. Chirurginnen und Chirurgen bilden da keine Ausnahme, im Gegenteil.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.