Erschienen in:
01.10.2007 | Scientific Article
Comparison of MR arthrography with arthroscopy of the hip for the assessment of intra-articular loose bodies
verfasst von:
Andrew C. Neckers, Joshua M. Polster, Carl S. Winalski, Viktor E. Krebs, M. Sundaram
Erschienen in:
Skeletal Radiology
|
Ausgabe 10/2007
Einloggen, um Zugang zu erhalten
Abstract
Objective
To assess the specificity and sensitivity of MR arthrography of the hip in comparison with arthroscopy for the evaluation of intra-articular loose bodies.
Design
Over a 3-year period, 81 consecutive patients underwent a total of 82 hip arthroscopies by a single orthopedic surgeon for intractable hip pain. Of the 82 arthroscopies, 70 had pre-operative MR arthrograms. Of these, 57 were available for retrospective review, after which they were compared with the operative notes of the subsequent arthroscopies.
Results
Of 82 arthroscopies 16 (20%) demonstrated intra-articular loose bodies, while, in the study group, nine of 57 had loose bodies (16%). There was a total of seven discordant cases (five false negatives and two false positives). The sensitivity of MR arthrography for detection of intra-articular loose bodies was 44%, while the specificity was 96%.
Conclusion
While the specificity of MR arthrography for the detection of intra-articular loose bodies was high (96%), the sensitivity was not nearly as good (44%).