Skip to main content
Erschienen in: Radiological Physics and Technology 1/2019

10.12.2018

Computed tomography pulmonary angiography and venography with a low dose of contrast medium

verfasst von: Jun Nakane, Norinari Honda, Kazuhiro Tsuchiya

Erschienen in: Radiological Physics and Technology | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

The authors developed a method to ensure sufficient opacification of pulmonary vasculature for separate depiction of arteries and veins in three-dimensional form with a small dose of contrast medium utilizing a test injection to determine optimal timing of computed tomography (CT) scanning. The dose was determined by a simulation based on a pharmacokinetic model. The contrast medium was administered at a rate of 5.0 mL/s for 3 s, followed by helical scanning at the timing determined by a dynamic CT scanning following the test injection. Images of 20 consecutive patients acquired with a 64-row CT scanner were evaluated. Quality of vessel depiction was assessed on the basis of the following: HU values at the main pulmonary artery (MPA) and left atrium (LA), distance between the pleural surface and the distal end of the pulmonary vessels on three-dimensional CT pulmonary arteriography and venography (3D-CTPAV), and subjective visual assessment of quality of the 3D-CTPAV images. Time to generate the 3D-CTPAV images was recorded. The mean ± standard deviation (SD) of the HU values at MPA/LA and the distances to the pleural surface for pulmonary arteries/veins were 448.0 ± 123.1/277.3 ± 60.85 HU and 9.21 ± 3.60/10.7 ± 5.45 mm, respectively. The image quality was visually rated as excellent for all of the patients. The mean time ± SD to generate 3D-CTPAV images was 13.6 ± 6.7 min. In conclusion, three-dimensional images of the pulmonary vasculature can be created using 21 mL (including 6 mL for the test injection) of contrast medium.
Literatur
1.
Zurück zum Zitat McKenna RJ, Houck W, Fuller CB. Video-assisted thoracic surgery lobectomy: experience with 1,100 cases. Ann Thorac Surg. 2006;81:421–6.CrossRef McKenna RJ, Houck W, Fuller CB. Video-assisted thoracic surgery lobectomy: experience with 1,100 cases. Ann Thorac Surg. 2006;81:421–6.CrossRef
2.
Zurück zum Zitat Kaseda S, Aoki T, Hangai N. Video-assisted thoracic surgery (VATS) lobectomy: the Japanese experience. Semin Thorac Cardiovasc Surg. 1998;10:300–4.CrossRefPubMed Kaseda S, Aoki T, Hangai N. Video-assisted thoracic surgery (VATS) lobectomy: the Japanese experience. Semin Thorac Cardiovasc Surg. 1998;10:300–4.CrossRefPubMed
3.
Zurück zum Zitat Ohtaki Y, Shimizu K. Anatomical thoracoscopic segmentectomy for lung cancer. Gen Thorac Cardiovasc Surg. 2014;62:586–93.CrossRef Ohtaki Y, Shimizu K. Anatomical thoracoscopic segmentectomy for lung cancer. Gen Thorac Cardiovasc Surg. 2014;62:586–93.CrossRef
4.
Zurück zum Zitat Akiba T, Marushima H, Harada J, Kobayashi S, Morikawa T. Anomalous pulmonary vein detected using three-dimensional computed tomography in a patient with lung cancer undergoing thoracoscopic lobectomy. Gen Thorac Cardiovasc Surg. 2008;56:413–6.CrossRefPubMed Akiba T, Marushima H, Harada J, Kobayashi S, Morikawa T. Anomalous pulmonary vein detected using three-dimensional computed tomography in a patient with lung cancer undergoing thoracoscopic lobectomy. Gen Thorac Cardiovasc Surg. 2008;56:413–6.CrossRefPubMed
5.
Zurück zum Zitat Watanabe S, Arai K, Watanabe T, Koda W, Urayama H. Use of three-dimensional computed tomographic angiography of pulmonary vessels for lung resections. Ann Thorac Surg. 2003;75:388–92.CrossRefPubMed Watanabe S, Arai K, Watanabe T, Koda W, Urayama H. Use of three-dimensional computed tomographic angiography of pulmonary vessels for lung resections. Ann Thorac Surg. 2003;75:388–92.CrossRefPubMed
6.
Zurück zum Zitat Fukuhara K, Akashi A, Nakane S, Tomita E. Preoperative assessment of the pulmonary artery by three-dimensional computed tomography before video-assisted thoracic surgery lobectomy. Eur J Cardiothorac Surg. 2008;34:875–7.CrossRefPubMed Fukuhara K, Akashi A, Nakane S, Tomita E. Preoperative assessment of the pulmonary artery by three-dimensional computed tomography before video-assisted thoracic surgery lobectomy. Eur J Cardiothorac Surg. 2008;34:875–7.CrossRefPubMed
7.
Zurück zum Zitat Tane S, Ohno Y, Hokka D, Ogawa H, Tauchi S, Nishio W, Yoshimura M, Okita Y, Maniwa Y. The efficacy of 320-detector row computed tomography for the assessment of preoperative pulmonary vasculature of candidates for pulmonary segmentectomy. Interact Cardiovasc Thorac Surg. 2013;17:974–80.CrossRefPubMedPubMedCentral Tane S, Ohno Y, Hokka D, Ogawa H, Tauchi S, Nishio W, Yoshimura M, Okita Y, Maniwa Y. The efficacy of 320-detector row computed tomography for the assessment of preoperative pulmonary vasculature of candidates for pulmonary segmentectomy. Interact Cardiovasc Thorac Surg. 2013;17:974–80.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Fourdrain A, De Dominicis F, Blanchard C, Iquille J, Lafitte S, Beuvry PL, Michel D, Merlusca G, Havet E, Berna P. Three-dimensional CT angiography of anatomic variations in the pulmonary arterial tree. Surg Radiol Anat. 2018;40:45–53.CrossRefPubMed Fourdrain A, De Dominicis F, Blanchard C, Iquille J, Lafitte S, Beuvry PL, Michel D, Merlusca G, Havet E, Berna P. Three-dimensional CT angiography of anatomic variations in the pulmonary arterial tree. Surg Radiol Anat. 2018;40:45–53.CrossRefPubMed
9.
Zurück zum Zitat Chen-Yoshikawa TF, Date H. Update on three-dimensional image reconstruction for preoperative simulation in thoracic surgery. J Thorac Dis. 2016;8:295–301.CrossRef Chen-Yoshikawa TF, Date H. Update on three-dimensional image reconstruction for preoperative simulation in thoracic surgery. J Thorac Dis. 2016;8:295–301.CrossRef
10.
Zurück zum Zitat Masin-Spasovska J, Spasovski G, Dzikova S, Grcevska L, Petrusevska G, Lekovski L, Popov Z, Ivanovski N. Protocol biopsies in kidney transplant recipients: histologic findings as prognostic markers for graft function and outcome. Transplant Proc. 2005;37:705–8.CrossRefPubMed Masin-Spasovska J, Spasovski G, Dzikova S, Grcevska L, Petrusevska G, Lekovski L, Popov Z, Ivanovski N. Protocol biopsies in kidney transplant recipients: histologic findings as prognostic markers for graft function and outcome. Transplant Proc. 2005;37:705–8.CrossRefPubMed
11.
Zurück zum Zitat Vercellino M, Bezante GP, Balbi M. Contrast medium induced nephropathy: new insights into prevention and risk management. Cardiovasc Hematol Agents Med Chem. 2009;7:166–80.CrossRefPubMed Vercellino M, Bezante GP, Balbi M. Contrast medium induced nephropathy: new insights into prevention and risk management. Cardiovasc Hematol Agents Med Chem. 2009;7:166–80.CrossRefPubMed
12.
Zurück zum Zitat Caruso D, Eid M, Schoepf UJ, De Santis D, Varga-Szemes A, Mangold S, Canstein C, Lesslie VW, Fuller SR, Ball BD, Laghi A. Optimizing contrast media injection protocols in computed tomography angiography at different tube voltages: evaluation in a circulation phantom. J Comput Assist Tomogr. 2017;41:804–10.CrossRefPubMed Caruso D, Eid M, Schoepf UJ, De Santis D, Varga-Szemes A, Mangold S, Canstein C, Lesslie VW, Fuller SR, Ball BD, Laghi A. Optimizing contrast media injection protocols in computed tomography angiography at different tube voltages: evaluation in a circulation phantom. J Comput Assist Tomogr. 2017;41:804–10.CrossRefPubMed
13.
Zurück zum Zitat Faggioni L, Neri E, Sbragia P, Pascale R, D’Errico L, Caramella D, Bartolozzi C. 80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL) and iomeprol (400 mg I/mL). Am J Roentgenol. 2012;199:1220–5.CrossRef Faggioni L, Neri E, Sbragia P, Pascale R, D’Errico L, Caramella D, Bartolozzi C. 80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL) and iomeprol (400 mg I/mL). Am J Roentgenol. 2012;199:1220–5.CrossRef
14.
Zurück zum Zitat Lu GM, Luo S, Meinel FG, McQuiston AD, Zhou CS, Kong X, Zhao YE, Zheng L, Schoepf UJ, Zhang LJ. High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume. Eur Radiol. 2014;24:3260–8.CrossRefPubMed Lu GM, Luo S, Meinel FG, McQuiston AD, Zhou CS, Kong X, Zhao YE, Zheng L, Schoepf UJ, Zhang LJ. High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume. Eur Radiol. 2014;24:3260–8.CrossRefPubMed
15.
Zurück zum Zitat Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology. 2010;256:32–61.CrossRefPubMed Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology. 2010;256:32–61.CrossRefPubMed
16.
Zurück zum Zitat Yamaguchi I, Kidoya E, Suzuki M, Kimura H. Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography. Radiol Phys Technol. 2011;4:43–52.CrossRefPubMed Yamaguchi I, Kidoya E, Suzuki M, Kimura H. Optimizing scan timing of hepatic arterial phase by physiologic pharmacokinetic analysis in bolus-tracking technique by multi-detector row computed tomography. Radiol Phys Technol. 2011;4:43–52.CrossRefPubMed
17.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology. 1998;207:647–55.CrossRefPubMed Bae KT, Heiken JP, Brink JA. Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology. 1998;207:647–55.CrossRefPubMed
18.
Zurück zum Zitat Kawaguchi N, Kurata A, Kido T, Nishiyama Y, Kido T, Miyagawa M, Ogimoto A, Mochizuki T. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material. Circ J. 2014;78:662–70.CrossRefPubMed Kawaguchi N, Kurata A, Kido T, Nishiyama Y, Kido T, Miyagawa M, Ogimoto A, Mochizuki T. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material. Circ J. 2014;78:662–70.CrossRefPubMed
19.
Zurück zum Zitat Lee SM, Lee H-J, Kim JI, Kang MJ, Goo JM, Park CM, Im JG. Adaptive 4D volume perfusion CT of lung cancer: effects of computerized motion correction and the range of volume coverage on measurement reproducibility. Am J Roentgenol. 2013;200:W603–9.CrossRef Lee SM, Lee H-J, Kim JI, Kang MJ, Goo JM, Park CM, Im JG. Adaptive 4D volume perfusion CT of lung cancer: effects of computerized motion correction and the range of volume coverage on measurement reproducibility. Am J Roentgenol. 2013;200:W603–9.CrossRef
20.
Zurück zum Zitat Hinrichs JB, von Falck C, Hoeper MM, Olsson KM, Wacker FK, Meyer BC, Renne J. Pulmonary artery imaging in patients with chronic thromboembolic pulmonary hypertension: comparison of cone-beam CT and 64-row multidetector CT. J Vasc Interv Radiol. 2016;27:361–8.e2.CrossRefPubMed Hinrichs JB, von Falck C, Hoeper MM, Olsson KM, Wacker FK, Meyer BC, Renne J. Pulmonary artery imaging in patients with chronic thromboembolic pulmonary hypertension: comparison of cone-beam CT and 64-row multidetector CT. J Vasc Interv Radiol. 2016;27:361–8.e2.CrossRefPubMed
21.
Zurück zum Zitat Raczeck P, Minko P, Graeber S, Fries P, Seidel R, Buecker A, Stroeder J. Influence of respiratory position on contrast attenuation in pulmonary CT angiography: a prospective randomized clinical trial. Am J Roentgenol. 2016;206:481–6.CrossRef Raczeck P, Minko P, Graeber S, Fries P, Seidel R, Buecker A, Stroeder J. Influence of respiratory position on contrast attenuation in pulmonary CT angiography: a prospective randomized clinical trial. Am J Roentgenol. 2016;206:481–6.CrossRef
Metadaten
Titel
Computed tomography pulmonary angiography and venography with a low dose of contrast medium
verfasst von
Jun Nakane
Norinari Honda
Kazuhiro Tsuchiya
Publikationsdatum
10.12.2018
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 1/2019
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-018-00492-5

Weitere Artikel der Ausgabe 1/2019

Radiological Physics and Technology 1/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.