Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 5/2022

07.11.2021 | Original Research

Continuous transthoracic echocardiographic monitoring for changes in maternal cardiac hemodynamics during cesarean section under combined epidural–spinal anesthesia: a prospective, observational study

verfasst von: Zhimin Liao, Shimiao Feng, Haibo Song, Han Huang

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 5/2022

Einloggen, um Zugang zu erhalten

Abstract

The change in maternal hemodynamics during cesarean section has not been well studied. Continuous transthoracic echocardiography can monitor cardiac function continuously. This study aimed to evaluate the effectiveness of maternal hemodynamic parameters monitoring during cesarean section using continuous transthoracic echocardiography. In this prospective, observational study, women with an uncomplicated singleton pregnancy scheduled for elective cesarean section at term under combined spinal–epidural anesthesia were enrolled. Maternal hemodynamic parameters were assessed by continuous transthoracic echocardiography at 11 pre-set time points. The image quality of continuous transthoracic echocardiography was evaluated before measurement was performed. Totally, one hundred parturients were recruited, and transthoracic echocardiography images with sufficient quality for further analysis were obtained in 72 women. Following anesthesia, maternal heart rate decreased by 11.18% and cardiac output decreased by 7.82%, but stroke volume remained stable. After delivery of the neonate and placenta, stroke volume and cardiac output increased by 21.09% and 22.33%, respectively. End-diastolic volume also increased significantly after delivery of the neonate, but end-systolic volume was unchanged. Following delivery of the neonate, fractional shortening increased till the end of the cesarean section while total peripheral resistance decreased significantly. In conclusion, continuous transthoracic echocardiographic monitoring revealed that there were significant changes in hemodynamic parameters during cesarean section after delivery of the newborn and placenta, which warranted further investigation.
Literatur
1.
Zurück zum Zitat van Oppen AC, van der Tweel I, Alsbach GP, Heethaar RM, Bruinse HW. A longitudinal study of maternal hemodynamics during normal pregnancy. Obstet Gynecol. 1996;88(1):40–6.CrossRef van Oppen AC, van der Tweel I, Alsbach GP, Heethaar RM, Bruinse HW. A longitudinal study of maternal hemodynamics during normal pregnancy. Obstet Gynecol. 1996;88(1):40–6.CrossRef
2.
Zurück zum Zitat Hunter S, Robson SC. Adaptation of the maternal heart in pregnancy. Br Heart J. 1992;68(6):540–3.CrossRef Hunter S, Robson SC. Adaptation of the maternal heart in pregnancy. Br Heart J. 1992;68(6):540–3.CrossRef
3.
Zurück zum Zitat Sanghavi M, Rutherford JD. Cardiovascular physiology of pregnancy. Circulation. 2014;130(12):1003–8.CrossRef Sanghavi M, Rutherford JD. Cardiovascular physiology of pregnancy. Circulation. 2014;130(12):1003–8.CrossRef
4.
Zurück zum Zitat Langesaeter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology. 2008;109(5):856–63.CrossRef Langesaeter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology. 2008;109(5):856–63.CrossRef
5.
Zurück zum Zitat Liu Y, Pian-Smith MC, Leffert LR, Minehart RD, Torri A, Coté C, Kacmarek RM, Jiang Y. Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery. J Clin Monit Comput. 2015;29(5):627–34.CrossRef Liu Y, Pian-Smith MC, Leffert LR, Minehart RD, Torri A, Coté C, Kacmarek RM, Jiang Y. Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery. J Clin Monit Comput. 2015;29(5):627–34.CrossRef
6.
Zurück zum Zitat Tihtonen K, Kööbi T, Yli-Hankala A, Uotila J. Maternal hemodynamics during cesarean delivery assessed by whole-body impedance cardiography. Acta Obstet Gynecol Scand. 2005;84(4):355–61.CrossRef Tihtonen K, Kööbi T, Yli-Hankala A, Uotila J. Maternal hemodynamics during cesarean delivery assessed by whole-body impedance cardiography. Acta Obstet Gynecol Scand. 2005;84(4):355–61.CrossRef
7.
Zurück zum Zitat Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg. 2010;111(5):1230–7.CrossRef Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg. 2010;111(5):1230–7.CrossRef
8.
Zurück zum Zitat Ram M, Lavie A, Lev S, Blecher Y, Amikam U, Shulman Y, Avnon T, Weiner E, Many A. Cardiac hemodynamics before, during and after elective cesarean section under spinal anesthesia in low-risk women. J Perinatol. 2017;37(7):793–9.CrossRef Ram M, Lavie A, Lev S, Blecher Y, Amikam U, Shulman Y, Avnon T, Weiner E, Many A. Cardiac hemodynamics before, during and after elective cesarean section under spinal anesthesia in low-risk women. J Perinatol. 2017;37(7):793–9.CrossRef
9.
Zurück zum Zitat Mon W, Stewart A, Fernando R, Ashpole K, El-Wahab N, MacDonald S, Tamilselvan P, Columb M, Liu YM. Cardiac output changes with phenylephrine and ephedrine infusions during spinal anesthesia for cesarean section: a randomized, double-blind trial. J Clin Anesth. 2017;37:43–8.CrossRef Mon W, Stewart A, Fernando R, Ashpole K, El-Wahab N, MacDonald S, Tamilselvan P, Columb M, Liu YM. Cardiac output changes with phenylephrine and ephedrine infusions during spinal anesthesia for cesarean section: a randomized, double-blind trial. J Clin Anesth. 2017;37:43–8.CrossRef
10.
Zurück zum Zitat Dyer RA, Reed AR, van Dyk D, Arcache MJ, Hodges O, Lombard CJ, Greenwood J, James MF. Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery. Anesthesiology. 2009;111(4):753–65.CrossRef Dyer RA, Reed AR, van Dyk D, Arcache MJ, Hodges O, Lombard CJ, Greenwood J, James MF. Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery. Anesthesiology. 2009;111(4):753–65.CrossRef
11.
Zurück zum Zitat Tanaka H, Tanaka K, Tsuji M, Magawa S, Hatano F, Nii M, Ikeda T. Non-invasive monitoring of the cardiac effects of continuous intravenous oxytocin infusion during cesarean delivery. Int J Gynaecol Obstet. 2017;139:251–2.CrossRef Tanaka H, Tanaka K, Tsuji M, Magawa S, Hatano F, Nii M, Ikeda T. Non-invasive monitoring of the cardiac effects of continuous intravenous oxytocin infusion during cesarean delivery. Int J Gynaecol Obstet. 2017;139:251–2.CrossRef
12.
Zurück zum Zitat Rosseland LA, Hauge TH, Grindheim G, Stubhaug A, Langesæter E. Changes in blood pressure and cardiac output during cesarean delivery: the effects of oxytocin and carbetocin compared with placebo. Anesthesiology. 2013;119(3):541–51.CrossRef Rosseland LA, Hauge TH, Grindheim G, Stubhaug A, Langesæter E. Changes in blood pressure and cardiac output during cesarean delivery: the effects of oxytocin and carbetocin compared with placebo. Anesthesiology. 2013;119(3):541–51.CrossRef
13.
Zurück zum Zitat Rabow S, Olofsson P. Pulse wave analysis by digital photoplethysmography to record maternal hemodynamic effects of spinal anesthesia, delivethry of the baby, and intravenous oxytocin during cesarean section. J Matern Fetal Neonatal Med. 2017;30(7):759–66.CrossRef Rabow S, Olofsson P. Pulse wave analysis by digital photoplethysmography to record maternal hemodynamic effects of spinal anesthesia, delivethry of the baby, and intravenous oxytocin during cesarean section. J Matern Fetal Neonatal Med. 2017;30(7):759–66.CrossRef
14.
Zurück zum Zitat Thomas JS, Koh SH, Cooper GM. Haemodynamic effects of oxytocin given as i.v. bolus or infusion on women undergoing Caesarean section. Br J Anaesth. 2007;98(1):116–9.CrossRef Thomas JS, Koh SH, Cooper GM. Haemodynamic effects of oxytocin given as i.v. bolus or infusion on women undergoing Caesarean section. Br J Anaesth. 2007;98(1):116–9.CrossRef
15.
Zurück zum Zitat Zieleskiewicz L, Noel A, Duclos G, Haddam M, Delmas A, Bechis C, Loundou A, Blanc J, Mignon A, Bouvet L, Einav S, Bourgoin A, Leone M. Can point-of-care ultrasound predict spinal hypotension during caesarean section? A prospective observational study. Anaesthesia. 2018;73(1):15–22.CrossRef Zieleskiewicz L, Noel A, Duclos G, Haddam M, Delmas A, Bechis C, Loundou A, Blanc J, Mignon A, Bouvet L, Einav S, Bourgoin A, Leone M. Can point-of-care ultrasound predict spinal hypotension during caesarean section? A prospective observational study. Anaesthesia. 2018;73(1):15–22.CrossRef
16.
Zurück zum Zitat Zieleskiewicz L, Bouvet L, Einav S, Duclos G, Leone M. Diagnostic point-of-care ultrasound: applications in obstetric anaesthetic management. Anaesthesia. 2018;73(10):1265–79.CrossRef Zieleskiewicz L, Bouvet L, Einav S, Duclos G, Leone M. Diagnostic point-of-care ultrasound: applications in obstetric anaesthetic management. Anaesthesia. 2018;73(10):1265–79.CrossRef
17.
Zurück zum Zitat Easterling TR, Watts DH, Schmucker BC, Benedetti TJ. Measurement of cardiac output during pregnancy: validation of Doppler technique and clinical observations in preeclampsia. Obstet Gynecol. 1987;69(6):845–50.PubMed Easterling TR, Watts DH, Schmucker BC, Benedetti TJ. Measurement of cardiac output during pregnancy: validation of Doppler technique and clinical observations in preeclampsia. Obstet Gynecol. 1987;69(6):845–50.PubMed
18.
Zurück zum Zitat Robson SC, Dunlop W, Moore M, Hunter S. Combined Doppler and echocardiographic measurement of cardiac output: theory and application in pregnancy. Br J Obstet Gynaecol. 1987;94(11):1014–27.CrossRef Robson SC, Dunlop W, Moore M, Hunter S. Combined Doppler and echocardiographic measurement of cardiac output: theory and application in pregnancy. Br J Obstet Gynaecol. 1987;94(11):1014–27.CrossRef
19.
Zurück zum Zitat Song H, Tsai SK, Liu J. Tailored holder for continuous echocardiographic monitoring. Anesth Analg. 2018;126(2):435–7.CrossRef Song H, Tsai SK, Liu J. Tailored holder for continuous echocardiographic monitoring. Anesth Analg. 2018;126(2):435–7.CrossRef
20.
Zurück zum Zitat Ramsingh D, Rinehart J, Kain Z, Strom S, Canales C, Alexander B, Capatina A, Ma M, Le KV, Cannesson M. Impact assessment of perioperative point-of-care ultrasound training on anesthesiology residents. Anesthesiology. 2015;123(3):670–82.CrossRef Ramsingh D, Rinehart J, Kain Z, Strom S, Canales C, Alexander B, Capatina A, Ma M, Le KV, Cannesson M. Impact assessment of perioperative point-of-care ultrasound training on anesthesiology residents. Anesthesiology. 2015;123(3):670–82.CrossRef
21.
Zurück zum Zitat Royse CF. Ultrasound-guided haemodynamic state assessment. Best Pract Res Clin Anaesthesiol. 2009;23(3):273–83.CrossRef Royse CF. Ultrasound-guided haemodynamic state assessment. Best Pract Res Clin Anaesthesiol. 2009;23(3):273–83.CrossRef
22.
Zurück zum Zitat Robson SC, Boys RJ, Hunter S, Dunlop W. Maternal hemodynamics after normal delivery and delivery complicated by postpartum hemorrhage. Obstet Gynecol. 1989;74(2):234–9.PubMed Robson SC, Boys RJ, Hunter S, Dunlop W. Maternal hemodynamics after normal delivery and delivery complicated by postpartum hemorrhage. Obstet Gynecol. 1989;74(2):234–9.PubMed
23.
Zurück zum Zitat Lee W, Rokey R, Miller J, Cotton DB. Maternal hemodynamic effects of uterine contractions by M-mode and pulsed-Doppler echocardiography. Am J Obstet Gynecol. 1989;161(4):974–7.CrossRef Lee W, Rokey R, Miller J, Cotton DB. Maternal hemodynamic effects of uterine contractions by M-mode and pulsed-Doppler echocardiography. Am J Obstet Gynecol. 1989;161(4):974–7.CrossRef
24.
Zurück zum Zitat Li Y, Dong Y. Preoperative music intervention for patients undergoing cesarean delivery. Int J Gynaecol Obstet. 2012;119(1):81–3.CrossRef Li Y, Dong Y. Preoperative music intervention for patients undergoing cesarean delivery. Int J Gynaecol Obstet. 2012;119(1):81–3.CrossRef
25.
Zurück zum Zitat Zdanowicz JA, Utz AC, Bernasconi I, Geier S, Corti R, Beinder E. “Broken heart” after cesarean delivery. Case report and review of literature. Arch Gynecol Obstet. 2011;283(4):687–94.CrossRef Zdanowicz JA, Utz AC, Bernasconi I, Geier S, Corti R, Beinder E. “Broken heart” after cesarean delivery. Case report and review of literature. Arch Gynecol Obstet. 2011;283(4):687–94.CrossRef
26.
Zurück zum Zitat Crimi E, Baggish A, Leffert L, Pian-Smith MC, Januzzi JL, Jiang Y. Images in cardiovascular medicine. Acute reversible stress-induced cardiomyopathy associated with cesarean delivery under spinal anesthesia. Circulation. 2008;117(23):3052–3.CrossRef Crimi E, Baggish A, Leffert L, Pian-Smith MC, Januzzi JL, Jiang Y. Images in cardiovascular medicine. Acute reversible stress-induced cardiomyopathy associated with cesarean delivery under spinal anesthesia. Circulation. 2008;117(23):3052–3.CrossRef
27.
Zurück zum Zitat Cornette J, Laker S, Jeffery B, Lombaard H, Alberts A, Rizopoulos D, Roos-Hesselink JW, Pattinson RC. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review. Ultrasound Obstet Gynecol. 2017;49(1):25–31.CrossRef Cornette J, Laker S, Jeffery B, Lombaard H, Alberts A, Rizopoulos D, Roos-Hesselink JW, Pattinson RC. Validation of maternal cardiac output assessed by transthoracic echocardiography against pulmonary artery catheterization in severely ill pregnant women: prospective comparative study and systematic review. Ultrasound Obstet Gynecol. 2017;49(1):25–31.CrossRef
29.
Zurück zum Zitat Dennis AT, Stenson A. The use of transthoracic echocardiography in postpartum hypotension. Anesth Analg. 2012;115(5):1033–7.CrossRef Dennis AT, Stenson A. The use of transthoracic echocardiography in postpartum hypotension. Anesth Analg. 2012;115(5):1033–7.CrossRef
30.
Zurück zum Zitat Dennis AT. Transthoracic echocardiography in obstetric anaesthesia and obstetric critical illness. Int J Obstet Anesth. 2011;20(2):160–8.CrossRef Dennis AT. Transthoracic echocardiography in obstetric anaesthesia and obstetric critical illness. Int J Obstet Anesth. 2011;20(2):160–8.CrossRef
31.
Zurück zum Zitat Dennis AT, Castro J, Carr C, Simmons S, Permezel M, Royse C. Haemodynamics in women with untreated pre-eclampsia. Anaesthesia. 2012;67(10):1105–18.CrossRef Dennis AT, Castro J, Carr C, Simmons S, Permezel M, Royse C. Haemodynamics in women with untreated pre-eclampsia. Anaesthesia. 2012;67(10):1105–18.CrossRef
32.
Zurück zum Zitat Arora G, Morss AM, Piazza G, Ryan JW, Diwoodey DL, Rofsky NM, Manning WJ, Chuang ML. Differences in left ventricular ejection fraction using teichholz formula and volumetric methods by cmr: implications for patient stratification and selection of therapy. J Cardiovasc Magn Reson. 2010;12:202. https://doi.org/10.1186/1532-429X-12-S1-P202.CrossRef Arora G, Morss AM, Piazza G, Ryan JW, Diwoodey DL, Rofsky NM, Manning WJ, Chuang ML. Differences in left ventricular ejection fraction using teichholz formula and volumetric methods by cmr: implications for patient stratification and selection of therapy. J Cardiovasc Magn Reson. 2010;12:202. https://​doi.​org/​10.​1186/​1532-429X-12-S1-P202.CrossRef
33.
Zurück zum Zitat Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, Flachskampf FA, Foster E, Goldstein SA, Kuznetsova T, Lancellotti P, Muraru D, Picard MH, Rietzschel ER, Rudski L, Spencer KT, Tsang W, Voigt JU. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American society of echocardiography and the European association of cardiovascular imaging. Eur Heart J Cardiovasc Imaging. 2015;16(3):233–70.CrossRef Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, Flachskampf FA, Foster E, Goldstein SA, Kuznetsova T, Lancellotti P, Muraru D, Picard MH, Rietzschel ER, Rudski L, Spencer KT, Tsang W, Voigt JU. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American society of echocardiography and the European association of cardiovascular imaging. Eur Heart J Cardiovasc Imaging. 2015;16(3):233–70.CrossRef
34.
Zurück zum Zitat Petersen JW, Liu J, Chi YY, Lingis M, Williams RS, Rhoton-Vlasak A, Segal MS, Conrad KP. Comparison of multiple non-invasive methods of measuring cardiac output during pregnancy reveals marked heterogeneity in the magnitude of cardiac output change between women. Physiol Rep. 2017;5(8):e13223.CrossRef Petersen JW, Liu J, Chi YY, Lingis M, Williams RS, Rhoton-Vlasak A, Segal MS, Conrad KP. Comparison of multiple non-invasive methods of measuring cardiac output during pregnancy reveals marked heterogeneity in the magnitude of cardiac output change between women. Physiol Rep. 2017;5(8):e13223.CrossRef
Metadaten
Titel
Continuous transthoracic echocardiographic monitoring for changes in maternal cardiac hemodynamics during cesarean section under combined epidural–spinal anesthesia: a prospective, observational study
verfasst von
Zhimin Liao
Shimiao Feng
Haibo Song
Han Huang
Publikationsdatum
07.11.2021
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 5/2022
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-021-00777-y

Weitere Artikel der Ausgabe 5/2022

Journal of Clinical Monitoring and Computing 5/2022 Zur Ausgabe

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Beutel versus Maschine: Beste Beatmungstechnik bei Herzstillstand gesucht

02.05.2024 Kardiopulmonale Reanimation Nachrichten

Stehen die Chancen auf eine Rückkehr der Spontanzirkulation nach Herz-Kreislauf-Stillstand bei manueller oder maschineller Beatmung besser? Und unterscheidet sich das neurologische Outcome nach der Reanimation? Das belgische Herzstillstand-Register liefert die Daten für einen direkten Vergleich zwischen Beutel und Beatmungsgerät.

Tipps für den Umgang mit Behandlungsfehlern

01.05.2024 DGIM 2024 Kongressbericht

Es ist nur eine Frage der Zeit, bis es zu einem Zwischenfall kommt und ein Behandlungsfehler passiert. Doch wenn Ärztinnen und Ärzte gut vorbereitet sind, schaffen es alle Beteiligten den Umständen entsprechend gut durch diese Krise. 

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.