Skip to main content
Erschienen in: Digestive Diseases and Sciences 1/2016

01.01.2016 | Original Article

Correlation Between Capillary and Venous Blood Glucose in the Lactose Tolerance Test

verfasst von: José Luis Domínguez Jiménez, Antonio Fernández Suárez

Erschienen in: Digestive Diseases and Sciences | Ausgabe 1/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

The lactose tolerance test is a classic method for the study of lactose malabsorption. However, the methodology used has not been standardized, and this leads to differences in results.

Aim

The aim of this report was to analyze whether capillary blood glucose measurement is in agreement with venous blood glucose when performing lactose tolerance test.

Methods

This is a prospective study of consecutive patients with suspected lactose malabsorption who had lactose tolerance test performed in venous and capillary blood simultaneously, using a load of 50 g lactose. Agreement was measured using the concordance correlation coefficient of Lin (95 % CI) and Bland–Altman plots. The degree of agreement was measured using the Kappa index. A value of p < 0.05 was considered statistically significant.

Results

Eighty-four patients (68 % women) were included. The concordance correlation coefficient showed very poor agreement between the two techniques: 0.68 (0.58–0.77), 0.72 (0.62–0.8), and 0.77 (0.69–0.83) for baseline, 30, and 60 min, respectively. The Bland–Altman plots showed that capillary blood glucose measurements result in higher levels than venous blood glucose measurements, with mean differences of 0.39, 0.77, and 1.1 mmol/L at baseline, 30, and 60 min, respectively. The degree of agreement was low, with a Kappa index of 0.59 (p < 0.001).

Conclusions

The test measured in venous blood is not in agreement with the measurement obtained from capillary blood. It is likely that the diagnostic accuracy attributed without distinction to lactose tolerance test in different studies for lactose malabsorption is incorrect, making it necessary to specify the analysis method.
Literatur
1.
Zurück zum Zitat Usai-Satta P, Scarpa M, Oppia F, Cabras F. Lactose malabsorption and intolerance: what should be the best clinical management? World J Gastrointest Pharmacol Ther. 2012;3:29–33.PubMedCentralCrossRefPubMed Usai-Satta P, Scarpa M, Oppia F, Cabras F. Lactose malabsorption and intolerance: what should be the best clinical management? World J Gastrointest Pharmacol Ther. 2012;3:29–33.PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Scrimshaw NS, Murray EB. The acceptability of milk and milk products in populations with a high prevalence of lactose intolerance. Am J Clin Nutr. 1988;48:1079–1159.PubMed Scrimshaw NS, Murray EB. The acceptability of milk and milk products in populations with a high prevalence of lactose intolerance. Am J Clin Nutr. 1988;48:1079–1159.PubMed
3.
Zurück zum Zitat Suarez FL, Savaiano DA, Levitt MD. A comparison of symptoms after the consumption of milk or lactose-hydrolyzed milk by people with self-reported severe lactose intolerance. N Engl J Med. 1995;333:1–4.CrossRefPubMed Suarez FL, Savaiano DA, Levitt MD. A comparison of symptoms after the consumption of milk or lactose-hydrolyzed milk by people with self-reported severe lactose intolerance. N Engl J Med. 1995;333:1–4.CrossRefPubMed
4.
Zurück zum Zitat Johnson AO, Semenya JG, Buchowski MS, Enwonwu CO, Scrimshaw NS. Correlation of lactose maldigestion, lactose intolerance, and milk intolerance. Am J Clin Nutr. 1993;57:399–401.PubMed Johnson AO, Semenya JG, Buchowski MS, Enwonwu CO, Scrimshaw NS. Correlation of lactose maldigestion, lactose intolerance, and milk intolerance. Am J Clin Nutr. 1993;57:399–401.PubMed
5.
Zurück zum Zitat Schirru E, Corona V, Usai-Satta P, et al. Genetic testing improves the diagnosis of adult type hypolactasia in the Mediterranean population of Sardinia. Eur J Clin Nutr. 2007;61:1220–1225.CrossRefPubMed Schirru E, Corona V, Usai-Satta P, et al. Genetic testing improves the diagnosis of adult type hypolactasia in the Mediterranean population of Sardinia. Eur J Clin Nutr. 2007;61:1220–1225.CrossRefPubMed
6.
Zurück zum Zitat Hermida C, Guerra P, Martínez-Costa OH, et al. Phase I and phase IB clinical trials for the noninvasive evaluation of intestinal lactase with 4-galactosylxylose (gaxilose). J Clin Gastroenterol. 2013;47:501–508.CrossRefPubMed Hermida C, Guerra P, Martínez-Costa OH, et al. Phase I and phase IB clinical trials for the noninvasive evaluation of intestinal lactase with 4-galactosylxylose (gaxilose). J Clin Gastroenterol. 2013;47:501–508.CrossRefPubMed
7.
Zurück zum Zitat Shaw A, Davies G. Lactose intolerance: problems in diagnosis and treatment. J Clin Gastroenterol. 1999;28:208–216.CrossRefPubMed Shaw A, Davies G. Lactose intolerance: problems in diagnosis and treatment. J Clin Gastroenterol. 1999;28:208–216.CrossRefPubMed
8.
Zurück zum Zitat Domínguez Jiménez JL, Fernández Suárez A. Can we shorten the lactose tolerance test? Eur J Clin Nutr. 2014;68:106–108.CrossRefPubMed Domínguez Jiménez JL, Fernández Suárez A. Can we shorten the lactose tolerance test? Eur J Clin Nutr. 2014;68:106–108.CrossRefPubMed
9.
Zurück zum Zitat Alexandre V, Davila AM, Bouchoucha M, et al. Agreement between indirect calorimetry and traditional tests of lactose malabsorption. Dig Liver Dis. 2013;45:727–732.CrossRefPubMed Alexandre V, Davila AM, Bouchoucha M, et al. Agreement between indirect calorimetry and traditional tests of lactose malabsorption. Dig Liver Dis. 2013;45:727–732.CrossRefPubMed
10.
Zurück zum Zitat Babu J, Kumar S, Babu P, Prasad JH, Ghoshal UC. Frequency of lactose malabsorption among healthy southern and northern Indian populations by genetic analysis and lactose hydrogen breath and tolerance tests. Am J Clin Nutr. 2010;91:140–146.CrossRefPubMed Babu J, Kumar S, Babu P, Prasad JH, Ghoshal UC. Frequency of lactose malabsorption among healthy southern and northern Indian populations by genetic analysis and lactose hydrogen breath and tolerance tests. Am J Clin Nutr. 2010;91:140–146.CrossRefPubMed
11.
Zurück zum Zitat Ghoshal UC, Kumar S, Misra A, Mittal B. Lactose malabsorption diagnosed by 50 g dose is inferior to assess clinical intolerance and to predict response to milk withdrawal than 25 g dose in an endemic area. J Gastroenterol Hepatol. 2013;28:1462–1468.CrossRefPubMed Ghoshal UC, Kumar S, Misra A, Mittal B. Lactose malabsorption diagnosed by 50 g dose is inferior to assess clinical intolerance and to predict response to milk withdrawal than 25 g dose in an endemic area. J Gastroenterol Hepatol. 2013;28:1462–1468.CrossRefPubMed
12.
Zurück zum Zitat Plebani M. Does POCT reduce the risk of error in laboratory testing? Clin Chim Acta. 2009;404:59–64.CrossRefPubMed Plebani M. Does POCT reduce the risk of error in laboratory testing? Clin Chim Acta. 2009;404:59–64.CrossRefPubMed
15.
Zurück zum Zitat Gambino R, Bruns DE. Stabilization of glucose in blood samples: out with the old, in with the new. Clin Chem Lab Med. 2013;51:1883–1885.CrossRefPubMed Gambino R, Bruns DE. Stabilization of glucose in blood samples: out with the old, in with the new. Clin Chem Lab Med. 2013;51:1883–1885.CrossRefPubMed
16.
Zurück zum Zitat Lyon ME, Dubois JA, Fick GH, Lyon AW. Estimates of total analytical error in consumer and hospital glucometers contributed by hematocrit, maltose and ascorbate. J Diabetes Sci Technol. 2010;4:1479–1494.PubMedCentralCrossRefPubMed Lyon ME, Dubois JA, Fick GH, Lyon AW. Estimates of total analytical error in consumer and hospital glucometers contributed by hematocrit, maltose and ascorbate. J Diabetes Sci Technol. 2010;4:1479–1494.PubMedCentralCrossRefPubMed
17.
Zurück zum Zitat Lin LI. A note on the concordance correlation coefficient. Biometrics. 2000;56:324–325.CrossRef Lin LI. A note on the concordance correlation coefficient. Biometrics. 2000;56:324–325.CrossRef
18.
Zurück zum Zitat Corstjens AM, Ligtenberg JJ, van der Horst IC, et al. Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients. Crit Care. 2006;10:R135.PubMedCentralCrossRefPubMed Corstjens AM, Ligtenberg JJ, van der Horst IC, et al. Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients. Crit Care. 2006;10:R135.PubMedCentralCrossRefPubMed
19.
Zurück zum Zitat Savoca R, Jaworek B, Huber AR. New “plasma referenced” POCT glucose monitoring systems-are they suitable for glucose monitoring and diagnosis of diabetes? Clin Chim Acta. 2006;372:199–201.CrossRefPubMed Savoca R, Jaworek B, Huber AR. New “plasma referenced” POCT glucose monitoring systems-are they suitable for glucose monitoring and diagnosis of diabetes? Clin Chim Acta. 2006;372:199–201.CrossRefPubMed
20.
Zurück zum Zitat Akinbami F, Segal S, Schnipper JL, Stopfkuchen-Evans M, Mills J, Rogers SO. Tale of two sites: capillary versus arterial blood glucose testing in the operating room. Am J Surg. 2012;203:423–427.CrossRefPubMed Akinbami F, Segal S, Schnipper JL, Stopfkuchen-Evans M, Mills J, Rogers SO. Tale of two sites: capillary versus arterial blood glucose testing in the operating room. Am J Surg. 2012;203:423–427.CrossRefPubMed
21.
Zurück zum Zitat Izquierdo F, Fatela D, Chueca MP. Detección de interferencias y otros errores en la medición de la glucemia en glucómetros portátiles. Recomendaciones 2012. Documentos de la SEQC. Comisión de Interferencias y Efectos de los Medicamentos. http://www.seqc.es. Accessed December 2012. Izquierdo F, Fatela D, Chueca MP. Detección de interferencias y otros errores en la medición de la glucemia en glucómetros portátiles. Recomendaciones 2012. Documentos de la SEQC. Comisión de Interferencias y Efectos de los Medicamentos. http://​www.​seqc.​es. Accessed December 2012.
23.
Zurück zum Zitat Newcomer AD, McGill DB, Thomas PJ, Hofmann AF. Prospective comparison of indirect methods for detecting lactase deficiency. N Engl J Med. 1975;11:1232–1236.CrossRef Newcomer AD, McGill DB, Thomas PJ, Hofmann AF. Prospective comparison of indirect methods for detecting lactase deficiency. N Engl J Med. 1975;11:1232–1236.CrossRef
24.
Zurück zum Zitat Hermans M, Brummer R, Ruijgers A, Stockbrügger RW. The relationship between lactose tolerance test results and symptoms of lactose intolerance. Am J Gastroenterol. 1997;92:981–984.PubMed Hermans M, Brummer R, Ruijgers A, Stockbrügger RW. The relationship between lactose tolerance test results and symptoms of lactose intolerance. Am J Gastroenterol. 1997;92:981–984.PubMed
25.
Zurück zum Zitat Marton A, Xue X, Szilagyi A. Meta-analysis: the diagnostic accuracy of lactose breath hydrogen or lactose tolerance test for predicting the North European lactase polymorphism C/T-13910. Aliment Pharmacol Ther. 2012;35:429–440.CrossRefPubMed Marton A, Xue X, Szilagyi A. Meta-analysis: the diagnostic accuracy of lactose breath hydrogen or lactose tolerance test for predicting the North European lactase polymorphism C/T-13910. Aliment Pharmacol Ther. 2012;35:429–440.CrossRefPubMed
Metadaten
Titel
Correlation Between Capillary and Venous Blood Glucose in the Lactose Tolerance Test
verfasst von
José Luis Domínguez Jiménez
Antonio Fernández Suárez
Publikationsdatum
01.01.2016
Verlag
Springer US
Erschienen in
Digestive Diseases and Sciences / Ausgabe 1/2016
Print ISSN: 0163-2116
Elektronische ISSN: 1573-2568
DOI
https://doi.org/10.1007/s10620-015-3851-1

Weitere Artikel der Ausgabe 1/2016

Digestive Diseases and Sciences 1/2016 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

RAS-Blocker bei Hyperkaliämie möglichst nicht sofort absetzen

14.05.2024 Hyperkaliämie Nachrichten

Bei ausgeprägter Nierenfunktionsstörung steigen unter der Einnahme von Renin-Angiotensin-System(RAS)-Hemmstoffen nicht selten die Serumkaliumspiegel. Was in diesem Fall zu tun ist, erklärte Prof. Jürgen Floege beim diesjährigen Allgemeinmedizin-Update-Seminar.

Gestationsdiabetes: In der zweiten Schwangerschaft folgenreicher als in der ersten

13.05.2024 Gestationsdiabetes Nachrichten

Das Risiko, nach einem Gestationsdiabetes einen Typ-2-Diabetes zu entwickeln, hängt nicht nur von der Zahl, sondern auch von der Reihenfolge der betroffenen Schwangerschaften ab.

Labor, CT-Anthropometrie zeigen Risiko für Pankreaskrebs

13.05.2024 Pankreaskarzinom Nachrichten

Gerade bei aggressiven Malignomen wie dem duktalen Adenokarzinom des Pankreas könnte Früherkennung die Therapiechancen verbessern. Noch jedoch klafft hier eine Lücke. Ein Studienteam hat einen Weg gesucht, sie zu schließen.

Battle of Experts: Sport vs. Spritze bei Adipositas und Typ-2-Diabetes

11.05.2024 DDG-Jahrestagung 2024 Kongressbericht

Im Battle of Experts traten zwei Experten auf dem Diabeteskongress gegeneinander an: Die eine vertrat die Auffassung „Sport statt Spritze“ bei Adipositas und Typ-2-Diabetes, der andere forderte „Spritze statt Sport!“ Am Ende waren sie sich aber einig: Die Kombination aus beidem erzielt die besten Ergebnisse.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.