Skip to main content
Erschienen in: European Radiology 5/2007

01.05.2007 | Cardiac

Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

verfasst von: Marc Dewey, Bernd Hamm

Erschienen in: European Radiology | Ausgabe 5/2007

Einloggen, um Zugang zu erhalten

Abstract

We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of €4,435 (10% likelihood) to €1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society.
Literatur
1.
Zurück zum Zitat Drummond MF, Jefferson TO (1996) Guidelines for authors and peer reviewers of economic submissions to the BMJ. The BMJ economic evaluation working party. BMJ 313:275–283PubMed Drummond MF, Jefferson TO (1996) Guidelines for authors and peer reviewers of economic submissions to the BMJ. The BMJ economic evaluation working party. BMJ 313:275–283PubMed
2.
Zurück zum Zitat Lipton MJ, Metz CE (2000) Cost effectiveness in radiology. Eur Radiol 10 [Suppl 3]:S390–S392PubMedCrossRef Lipton MJ, Metz CE (2000) Cost effectiveness in radiology. Eur Radiol 10 [Suppl 3]:S390–S392PubMedCrossRef
3.
Zurück zum Zitat McNeil BJ (2000) Changing roles of decision analysis and cost effectiveness analyses in medicine and radiology. Eur Radiol 10 [Suppl 3]:S340–S343PubMedCrossRef McNeil BJ (2000) Changing roles of decision analysis and cost effectiveness analyses in medicine and radiology. Eur Radiol 10 [Suppl 3]:S340–S343PubMedCrossRef
4.
Zurück zum Zitat Garber AM, Solomon NA (1999) Cost effectiveness of alternative test strategies for the diagnosis of coronary artery disease. Ann Intern Med 130:719–728PubMed Garber AM, Solomon NA (1999) Cost effectiveness of alternative test strategies for the diagnosis of coronary artery disease. Ann Intern Med 130:719–728PubMed
5.
Zurück zum Zitat Kuntz KM, Fleischmann KE, Hunink MG, Douglas PS (1999) Cost effectiveness of diagnostic strategies for patients with chest pain. Ann Intern Med 130:709–718PubMed Kuntz KM, Fleischmann KE, Hunink MG, Douglas PS (1999) Cost effectiveness of diagnostic strategies for patients with chest pain. Ann Intern Med 130:709–718PubMed
6.
Zurück zum Zitat Patterson RE, Eng C, Horowitz SF, Gorlin R, Goldstein SR (1984) Bayesian comparison of cost effectiveness of different clinical approaches to diagnose coronary artery disease. J Am Coll Cardiol 4:278–289PubMedCrossRef Patterson RE, Eng C, Horowitz SF, Gorlin R, Goldstein SR (1984) Bayesian comparison of cost effectiveness of different clinical approaches to diagnose coronary artery disease. J Am Coll Cardiol 4:278–289PubMedCrossRef
7.
Zurück zum Zitat Patterson RE, Eisner RL, Horowitz SF (1995) Comparison of cost effectiveness and utility of exercise ECG, single photon emission computed tomography, positron emission tomography, and coronary angiography for diagnosis of coronary artery disease. Circulation 91:54–65PubMed Patterson RE, Eisner RL, Horowitz SF (1995) Comparison of cost effectiveness and utility of exercise ECG, single photon emission computed tomography, positron emission tomography, and coronary angiography for diagnosis of coronary artery disease. Circulation 91:54–65PubMed
8.
Zurück zum Zitat Dewey M, Hamm B (2003) Cost effectiveness in diagnosis of coronary artery disease. Fortschr Rontgenstr 175:749–751CrossRef Dewey M, Hamm B (2003) Cost effectiveness in diagnosis of coronary artery disease. Fortschr Rontgenstr 175:749–751CrossRef
9.
Zurück zum Zitat Rumberger JA, Behrenbeck T, Breen JF, Sheedy PF 2nd (1999) Coronary calcification by electron beam computed tomography and obstructive coronary artery disease: a model for costs and effectiveness of diagnosis as compared with conventional cardiac testing methods. J Am Coll Cardiol 33:453–462PubMedCrossRef Rumberger JA, Behrenbeck T, Breen JF, Sheedy PF 2nd (1999) Coronary calcification by electron beam computed tomography and obstructive coronary artery disease: a model for costs and effectiveness of diagnosis as compared with conventional cardiac testing methods. J Am Coll Cardiol 33:453–462PubMedCrossRef
10.
Zurück zum Zitat Alanen J, Keski-Nisula L, Blanco-Sequeiros R, Tervonen O (2004) Cost comparison analysis of low-field (0.23 T) MRI- and CT-guided bone biopsies. Eur Radiol 14:123–128PubMedCrossRef Alanen J, Keski-Nisula L, Blanco-Sequeiros R, Tervonen O (2004) Cost comparison analysis of low-field (0.23 T) MRI- and CT-guided bone biopsies. Eur Radiol 14:123–128PubMedCrossRef
11.
Zurück zum Zitat Heller D, Hricak H (2000) Cost effectiveness of new technologies for staging endometrial cancer. Eur Radiol 10 [Suppl 3]:S381–S385PubMedCrossRef Heller D, Hricak H (2000) Cost effectiveness of new technologies for staging endometrial cancer. Eur Radiol 10 [Suppl 3]:S381–S385PubMedCrossRef
12.
Zurück zum Zitat Hövels AM, Heesakkers RA, Adang EM, Jager GJ, Barentsz JO (2004) Cost-analysis of staging methods for lymph nodes in patients with prostate cancer: MRI with a lymph node-specific contrast agent compared to pelvic lymph node dissection or CT. Eur Radiol 14:1707–1712PubMedCrossRef Hövels AM, Heesakkers RA, Adang EM, Jager GJ, Barentsz JO (2004) Cost-analysis of staging methods for lymph nodes in patients with prostate cancer: MRI with a lymph node-specific contrast agent compared to pelvic lymph node dissection or CT. Eur Radiol 14:1707–1712PubMedCrossRef
13.
Zurück zum Zitat Becker CR (2005) Coronary CT angiography in symptomatic patients. Eur Radiol 15 [Suppl 2]:B33–B41PubMed Becker CR (2005) Coronary CT angiography in symptomatic patients. Eur Radiol 15 [Suppl 2]:B33–B41PubMed
14.
Zurück zum Zitat Bogaert J, Dymarkowski S (2005) Delayed contrast-enhanced MRI: use in myocardial viability assessment and other cardiac pathology. Eur Radiol 15 [Suppl 2]:B52–B58PubMed Bogaert J, Dymarkowski S (2005) Delayed contrast-enhanced MRI: use in myocardial viability assessment and other cardiac pathology. Eur Radiol 15 [Suppl 2]:B52–B58PubMed
15.
Zurück zum Zitat Dewey M, Borges AC, Kivelitz D et al (2004) Coronary artery disease: new insights and their implications for radiology. Eur Radiol 14:1048–1054PubMedCrossRef Dewey M, Borges AC, Kivelitz D et al (2004) Coronary artery disease: new insights and their implications for radiology. Eur Radiol 14:1048–1054PubMedCrossRef
16.
Zurück zum Zitat Lipton MJ, Bogaert J, Boxt LM, Reba RC (2002) Imaging of ischemic heart disease. Eur Radiol 12:1061–1080PubMedCrossRef Lipton MJ, Bogaert J, Boxt LM, Reba RC (2002) Imaging of ischemic heart disease. Eur Radiol 12:1061–1080PubMedCrossRef
17.
Zurück zum Zitat Pugliese F, Mollet NR, Runza G et al (2005) Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol:1–8 Pugliese F, Mollet NR, Runza G et al (2005) Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol:1–8
18.
Zurück zum Zitat Klever-Deichert G, Hinzpeter B, Hunsche E, Lauterbach KW (1999) Costs of coronary heart diseases over the remaining life time in coronary heart disease cases—an analysis of the current status of coronary heart disease cases in Germany from the social perspective. Z Kardiol 88:991–1000PubMedCrossRef Klever-Deichert G, Hinzpeter B, Hunsche E, Lauterbach KW (1999) Costs of coronary heart diseases over the remaining life time in coronary heart disease cases—an analysis of the current status of coronary heart disease cases in Germany from the social perspective. Z Kardiol 88:991–1000PubMedCrossRef
19.
Zurück zum Zitat Dewey M, Hamm B (2004) Comparison of the cost effectiveness of the most common diagnostic methods for coronary artery disease. Dtsch Med Wochenschr 129:1415–1419PubMedCrossRef Dewey M, Hamm B (2004) Comparison of the cost effectiveness of the most common diagnostic methods for coronary artery disease. Dtsch Med Wochenschr 129:1415–1419PubMedCrossRef
20.
Zurück zum Zitat Diamond GA, Forrester JS (1979) Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 300:1350–1358PubMedCrossRef Diamond GA, Forrester JS (1979) Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 300:1350–1358PubMedCrossRef
21.
Zurück zum Zitat Pryor DB, Shaw L, McCants CB et al (1993) Value of the history and physical in identifying patients at increased risk for coronary artery disease. Ann Intern Med 118:81–90PubMed Pryor DB, Shaw L, McCants CB et al (1993) Value of the history and physical in identifying patients at increased risk for coronary artery disease. Ann Intern Med 118:81–90PubMed
22.
Zurück zum Zitat Horiguchi J, Fukuda H, Yamamoto H et al (2006) The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements. Eur Radiol. DOI 10.1007/s00330-006-0278-2 Horiguchi J, Fukuda H, Yamamoto H et al (2006) The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurements. Eur Radiol. DOI 10.​1007/​s00330-006-0278-2
23.
Zurück zum Zitat Mahnken AH, Muhlenbruch G, Koos R et al (2006) Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study. Eur Radiol 16:358–364PubMedCrossRef Mahnken AH, Muhlenbruch G, Koos R et al (2006) Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study. Eur Radiol 16:358–364PubMedCrossRef
24.
Zurück zum Zitat Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15 [Suppl 2]:B2–B9PubMed Wintersperger BJ, Nikolaou K (2005) Basics of cardiac MDCT: techniques and contrast application. Eur Radiol 15 [Suppl 2]:B2–B9PubMed
25.
Zurück zum Zitat Nallamothu BK, Saint S, Bielak LF et al (2001) Electron-beam computed tomography in the diagnosis of coronary artery disease: a meta-analysis. Arch Intern Med 161:833–838PubMedCrossRef Nallamothu BK, Saint S, Bielak LF et al (2001) Electron-beam computed tomography in the diagnosis of coronary artery disease: a meta-analysis. Arch Intern Med 161:833–838PubMedCrossRef
26.
Zurück zum Zitat Nagel E, Lehmkuhl HB, Bocksch W et al (1999) Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography. Circulation 99:763–770PubMed Nagel E, Lehmkuhl HB, Bocksch W et al (1999) Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography. Circulation 99:763–770PubMed
27.
Zurück zum Zitat Sommer T, Hofer U, Omran H, Schild H (2002) Stress cine MRI for detection of coronary artery disease. Fortschr Roentgenstr 174:605–613CrossRef Sommer T, Hofer U, Omran H, Schild H (2002) Stress cine MRI for detection of coronary artery disease. Fortschr Roentgenstr 174:605–613CrossRef
28.
Zurück zum Zitat Kwok Y, Kim C, Grady D, Segal M, Redberg R (1999) Meta-analysis of exercise testing to detect coronary artery disease in women. Am J Cardiol 83:660–666PubMedCrossRef Kwok Y, Kim C, Grady D, Segal M, Redberg R (1999) Meta-analysis of exercise testing to detect coronary artery disease in women. Am J Cardiol 83:660–666PubMedCrossRef
29.
Zurück zum Zitat Gibbons RJ, Balady GJ, Beasley JW et al (1997) ACC/AHA Guidelines for exercise testing. A report of the American college of cardiology/American heart association task force on practice guidelines (Committee on Exercise Testing). J Am Coll Cardiol 30:260–311PubMedCrossRef Gibbons RJ, Balady GJ, Beasley JW et al (1997) ACC/AHA Guidelines for exercise testing. A report of the American college of cardiology/American heart association task force on practice guidelines (Committee on Exercise Testing). J Am Coll Cardiol 30:260–311PubMedCrossRef
30.
Zurück zum Zitat Fleischmann KE, Hunink MG, Kuntz KM, Douglas PS (1998) Exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance. JAMA 280:913–920PubMedCrossRef Fleischmann KE, Hunink MG, Kuntz KM, Douglas PS (1998) Exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance. JAMA 280:913–920PubMedCrossRef
31.
Zurück zum Zitat Geleijnse ML, Fioretti PM, Roelandt JR (1997) Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 30:595–606PubMedCrossRef Geleijnse ML, Fioretti PM, Roelandt JR (1997) Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 30:595–606PubMedCrossRef
32.
Zurück zum Zitat Katayama H, Yamaguchi K, Kozuka T, Takashima T, Seez P, Matsuura K (1990) Adverse reactions to ionic and nonionic contrast media. A report from the Japanese committee on the safety of contrast media. Radiology 175:621–628PubMed Katayama H, Yamaguchi K, Kozuka T, Takashima T, Seez P, Matsuura K (1990) Adverse reactions to ionic and nonionic contrast media. A report from the Japanese committee on the safety of contrast media. Radiology 175:621–628PubMed
33.
Zurück zum Zitat Hiro J, Hiro T, Reid CL, Ebrahimi R, Matsuzaki M, Gardin JM (1997) Safety and results of dobutamine stress echocardiography in women versus men and in patients older and younger than 75 years of age. Am J Cardiol 80:1014–1020PubMedCrossRef Hiro J, Hiro T, Reid CL, Ebrahimi R, Matsuzaki M, Gardin JM (1997) Safety and results of dobutamine stress echocardiography in women versus men and in patients older and younger than 75 years of age. Am J Cardiol 80:1014–1020PubMedCrossRef
34.
Zurück zum Zitat Mertes H, Sawada SG, Ryan T et al (1993) Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients. Circulation 88:15–19PubMed Mertes H, Sawada SG, Ryan T et al (1993) Symptoms, adverse effects, and complications associated with dobutamine stress echocardiography. Experience in 1118 patients. Circulation 88:15–19PubMed
35.
Zurück zum Zitat Picano E, Mathias W Jr, Pingitore A, Bigi R, Previtali M (1994) Safety and tolerability of dobutamine–atropine stress echocardiography: a prospective, multicentre study. Echo Dobutamine International Cooperative Study Group. Lancet 344:1190–1192PubMedCrossRef Picano E, Mathias W Jr, Pingitore A, Bigi R, Previtali M (1994) Safety and tolerability of dobutamine–atropine stress echocardiography: a prospective, multicentre study. Echo Dobutamine International Cooperative Study Group. Lancet 344:1190–1192PubMedCrossRef
36.
Zurück zum Zitat Secknus MA, Marwick TH (1997) Evolution of dobutamine echocardiography protocols and indications: safety and side effects in 3011 studies over 5 years. J Am Coll Cardiol 29:1234–1240PubMedCrossRef Secknus MA, Marwick TH (1997) Evolution of dobutamine echocardiography protocols and indications: safety and side effects in 3011 studies over 5 years. J Am Coll Cardiol 29:1234–1240PubMedCrossRef
38.
Zurück zum Zitat Noto TJ Jr, Johnson LW, Krone R et al (1991) Cardiac catheterization 1990: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Catheter Cardiovasc Diagn 24:75–83CrossRef Noto TJ Jr, Johnson LW, Krone R et al (1991) Cardiac catheterization 1990: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Catheter Cardiovasc Diagn 24:75–83CrossRef
39.
Zurück zum Zitat Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054PubMedCrossRef Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ (2002) Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 106:2051–2054PubMedCrossRef
40.
Zurück zum Zitat Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666PubMedCrossRef Ropers D, Baum U, Pohle K et al (2003) Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664–666PubMedCrossRef
41.
Zurück zum Zitat Mollet NR, Cademartiri F, Nieman K et al (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43:2265–2270PubMedCrossRef Mollet NR, Cademartiri F, Nieman K et al (2004) Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 43:2265–2270PubMedCrossRef
42.
Zurück zum Zitat Hoffmann U, Moselewski F, Cury RC et al (2004) Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation 110:2638–2643PubMedCrossRef Hoffmann U, Moselewski F, Cury RC et al (2004) Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis. Circulation 110:2638–2643PubMedCrossRef
43.
Zurück zum Zitat Mollet NR, Cademartiri F, Krestin GP et al (2005) Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J Am Coll Cardiol 45:128–132PubMedCrossRef Mollet NR, Cademartiri F, Krestin GP et al (2005) Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. J Am Coll Cardiol 45:128–132PubMedCrossRef
44.
Zurück zum Zitat Hoffmann MH, Shi H, Schmitz BL et al (2005) Noninvasive coronary angiography with multislice computed tomography. JAMA 293:2471–2478PubMedCrossRef Hoffmann MH, Shi H, Schmitz BL et al (2005) Noninvasive coronary angiography with multislice computed tomography. JAMA 293:2471–2478PubMedCrossRef
45.
Zurück zum Zitat Dewey M, Teige F, Schnapauff D et al (2006) Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging. Ann Intern Med (in press) Dewey M, Teige F, Schnapauff D et al (2006) Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging. Ann Intern Med (in press)
46.
Zurück zum Zitat Achenbach S, Ropers D, Pohle FK et al (2005) Detection of coronary artery stenoses using multi-detector CT with 16×0.75 collimation and 375 ms rotation. Eur Heart J (Epub) Achenbach S, Ropers D, Pohle FK et al (2005) Detection of coronary artery stenoses using multi-detector CT with 16×0.75 collimation and 375 ms rotation. Eur Heart J (Epub)
47.
Zurück zum Zitat Kefer J, Coche E, Legros G et al (2005) Head-to-head comparison of three-dimensional navigator-gated magnetic resonance imaging and 16-slice computed tomography to detect coronary artery stenosis in patients. J Am Coll Cardiol 46:92–100PubMedCrossRef Kefer J, Coche E, Legros G et al (2005) Head-to-head comparison of three-dimensional navigator-gated magnetic resonance imaging and 16-slice computed tomography to detect coronary artery stenosis in patients. J Am Coll Cardiol 46:92–100PubMedCrossRef
48.
Zurück zum Zitat Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef
49.
Zurück zum Zitat Martuscelli E, Romagnoli A, D’Eliseo A et al (2004) Accuracy of thin-slice computed tomography in the detection of coronary stenoses. Eur Heart J 25:1043–1048PubMedCrossRef Martuscelli E, Romagnoli A, D’Eliseo A et al (2004) Accuracy of thin-slice computed tomography in the detection of coronary stenoses. Eur Heart J 25:1043–1048PubMedCrossRef
50.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef
52.
Zurück zum Zitat Tegtbur U, Machold H, Brinkmeier U, Busse M (2001) Ambulante kardiale Langzeitrehabilitation: 1-Jahres-Ergebnisse. Gesundheitswesen 63 [Suppl 1]:S39–S42PubMedCrossRef Tegtbur U, Machold H, Brinkmeier U, Busse M (2001) Ambulante kardiale Langzeitrehabilitation: 1-Jahres-Ergebnisse. Gesundheitswesen 63 [Suppl 1]:S39–S42PubMedCrossRef
53.
Zurück zum Zitat OECD. GDP per capita, 2001. In: OECD, 2003 OECD. GDP per capita, 2001. In: OECD, 2003
54.
Zurück zum Zitat Gandjour A, Lauterbach KW (2002) Cost effectiveness of quality improvement measures in health care. Med Klin 97:499–502CrossRef Gandjour A, Lauterbach KW (2002) Cost effectiveness of quality improvement measures in health care. Med Klin 97:499–502CrossRef
55.
Zurück zum Zitat Elkin M (1982) President’s address. Issues in radiology related to the new technologies. Radiology 143:1–6PubMed Elkin M (1982) President’s address. Issues in radiology related to the new technologies. Radiology 143:1–6PubMed
Metadaten
Titel
Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease
verfasst von
Marc Dewey
Bernd Hamm
Publikationsdatum
01.05.2007
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 5/2007
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0439-3

Weitere Artikel der Ausgabe 5/2007

European Radiology 5/2007 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.