Abstract

Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4°; volar tilt, 10.3°; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures.
Literatur
1.
Zurück zum Zitat Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12:1684–1692CrossRefPubMed Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12:1684–1692CrossRefPubMed
2.
Zurück zum Zitat Luboldt W, Mann C, Tryon CL et al (2002) Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast. Eur Radiol 12:2236–2241PubMed Luboldt W, Mann C, Tryon CL et al (2002) Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast. Eur Radiol 12:2236–2241PubMed
3.
Zurück zum Zitat Bernhardt TM, Schmidl H, Philipp C, Allhoff EP, Rapp-Bernhardt (2003) Diagnostic potential of virtual cyctoscopy of the bladder: MRI vs CT. Preliminary report. Eur Radiol 13:305–312PubMed Bernhardt TM, Schmidl H, Philipp C, Allhoff EP, Rapp-Bernhardt (2003) Diagnostic potential of virtual cyctoscopy of the bladder: MRI vs CT. Preliminary report. Eur Radiol 13:305–312PubMed
4.
Zurück zum Zitat Hsieh MS, Tsai MD, Chang WC (2002) Virtual reality simulator for osteotomy and fusion involving the musculoskeletal system. Comput Med Imaging Graph 26:91–101CrossRefPubMed Hsieh MS, Tsai MD, Chang WC (2002) Virtual reality simulator for osteotomy and fusion involving the musculoskeletal system. Comput Med Imaging Graph 26:91–101CrossRefPubMed
5.
Zurück zum Zitat Montgomery K, Stephanides M, Schendel S (2000) Development and application of a virtual environment for reconstructive surgery. Comput Aided Surg 5:90–97CrossRefPubMed Montgomery K, Stephanides M, Schendel S (2000) Development and application of a virtual environment for reconstructive surgery. Comput Aided Surg 5:90–97CrossRefPubMed
6.
Zurück zum Zitat Handels H, Ehrhardt J, Plötz W, Pöppl SJ (2001) Three-dimensional planning and simulation of hip operations and computer assisted construction of endoprostheses in bone tumor surgery. Comput Aided Surg 6:65–76CrossRefPubMed Handels H, Ehrhardt J, Plötz W, Pöppl SJ (2001) Three-dimensional planning and simulation of hip operations and computer assisted construction of endoprostheses in bone tumor surgery. Comput Aided Surg 6:65–76CrossRefPubMed
7.
Zurück zum Zitat McGrory BJ, Amadio PC (1998) Malunion of the distal radius: In: Cooney WP, Linscheid RL, Dobyns JH (eds) The wrist: diagnosis and oparative treatment. Mosby, St Louis, pp 356–384 McGrory BJ, Amadio PC (1998) Malunion of the distal radius: In: Cooney WP, Linscheid RL, Dobyns JH (eds) The wrist: diagnosis and oparative treatment. Mosby, St Louis, pp 356–384
8.
Zurück zum Zitat Hunt TR, Hastings H II, Graham TJ (1998) A systematic approach to handling the distal radio-ulnar joint in cases of malunited distal radius fractures. Hand Clin 14:239–249PubMed Hunt TR, Hastings H II, Graham TJ (1998) A systematic approach to handling the distal radio-ulnar joint in cases of malunited distal radius fractures. Hand Clin 14:239–249PubMed
9.
Zurück zum Zitat Bronstein AJ, Trumble TE, Tencer AF (1997) The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study. J Hand Surg 22:258–262PubMed Bronstein AJ, Trumble TE, Tencer AF (1997) The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study. J Hand Surg 22:258–262PubMed
10.
Zurück zum Zitat Melendez EM (1997) Opening-wedge osteotomy, bone graft, and external fixation for correction of radius malunion. J Hand Surg 22:785–791 Melendez EM (1997) Opening-wedge osteotomy, bone graft, and external fixation for correction of radius malunion. J Hand Surg 22:785–791
11.
Zurück zum Zitat Prommersberger KJ, Van Schoonhoven J, Lanz UB (2002) Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg 27:55–65CrossRef Prommersberger KJ, Van Schoonhoven J, Lanz UB (2002) Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg 27:55–65CrossRef
12.
Zurück zum Zitat Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg 28:951–958CrossRef Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg 28:951–958CrossRef
Metadaten
Titel
CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results
verfasst von
Michael Rieger
Markus Gabl
Hannes Gruber
Werner R. Jaschke
Ammar Mallouhi
Publikationsdatum
01.04.2005
Erschienen in
European Radiology / Ausgabe 4/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2353-x

Weitere Artikel der Ausgabe 4/2005

European Radiology 4/2005 Zur Ausgabe

Calendar of Events

April 2005

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.