Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 6/2012

01.12.2012

Detection of positional brachial plexus injury by radial arterial line during spinal exposure before neuromonitoring confirmation: a retrospective case study

verfasst von: Zhengyong Chen, Leo Chen, Paul Kwon, Michele Montez, Thomas Voegeli, Hans Bueff

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 6/2012

Einloggen, um Zugang zu erhalten

Abstract

To demonstrate the potential usefulness of radial arterial line monitoring in detection of brachial plexus injury in spinal surgery. Multiple neuromonitoring modalities including SEPs, MEPs and EMG were performed for a posterior thoracicolumbar surgery. Radial arterial line (A-line) was placed on the right wrist for arterial blood pressure monitoring. Reliable ulnar nerve SEPs, hand muscle MEPs and arterial blood pressure readings were obtained after patient was placed in a prone position. A-line malfunction was noted about 15 min after incision. Loss of ulnar nerve SEPs and hand muscle MEPs with a cold hand on the right was noticed when neuromonitoring resumed after spine exposure. SEPs, MEPs, A-line readings and hand temperature returned after modification of the right arm position. Radial arterial line monitoring may help detect positional brachial plexus injury in spinal surgery when continuous neuromonitoring is interrupted during spine exposure in prone position.
Literatur
1.
Zurück zum Zitat Büdinger K. Ueber Lähmungen nach Chloroformnarkosen. Arch Klin Chir. 1894;47:121. Büdinger K. Ueber Lähmungen nach Chloroformnarkosen. Arch Klin Chir. 1894;47:121.
2.
Zurück zum Zitat Britt B. Complications in anesthesiology. Philadelphia: Lippincott; 1983. p. 99–103. Britt B. Complications in anesthesiology. Philadelphia: Lippincott; 1983. p. 99–103.
3.
Zurück zum Zitat Kent CD, Cheney FW. A case of bilateral brachial plexus palsy due to shoulder braces. J Clin Anesth. 2007;19:482–4.PubMedCrossRef Kent CD, Cheney FW. A case of bilateral brachial plexus palsy due to shoulder braces. J Clin Anesth. 2007;19:482–4.PubMedCrossRef
4.
Zurück zum Zitat Balzer JR, Rose RD, Welch WC, Sclabassi RJ. Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompression and instrumentation. Neurosurgery. 1998;42:1318–25.PubMedCrossRef Balzer JR, Rose RD, Welch WC, Sclabassi RJ. Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompression and instrumentation. Neurosurgery. 1998;42:1318–25.PubMedCrossRef
5.
Zurück zum Zitat Labrom RD, Hoskins M, Reilly CW, Tredwell SJ, Wong PK. Clinical usefulness of somatosensory evoked potentials for detection of brachial plexopathy secondary to malpositioning in scoliosis surgery. Spine. 2005;30:2089–93.PubMedCrossRef Labrom RD, Hoskins M, Reilly CW, Tredwell SJ, Wong PK. Clinical usefulness of somatosensory evoked potentials for detection of brachial plexopathy secondary to malpositioning in scoliosis surgery. Spine. 2005;30:2089–93.PubMedCrossRef
6.
Zurück zum Zitat O’Brien MF, Lenke LG, Bridwell KH, Padberg A, Stokes M. Evoked potential monitoring of the upper extremities during thoracic and lumbar spinal deformity surgery: a prospective study. J Spinal Disord. 1994;7:277–84.PubMedCrossRef O’Brien MF, Lenke LG, Bridwell KH, Padberg A, Stokes M. Evoked potential monitoring of the upper extremities during thoracic and lumbar spinal deformity surgery: a prospective study. J Spinal Disord. 1994;7:277–84.PubMedCrossRef
7.
Zurück zum Zitat Schwartz DM, Drummond DS, Hahn M, Ecker ML, Dormans JP. Prevention of positional brachial plexopathy during surgical correction of scoliosis. J Spinal Disord. 2000;13:178–82.PubMedCrossRef Schwartz DM, Drummond DS, Hahn M, Ecker ML, Dormans JP. Prevention of positional brachial plexopathy during surgical correction of scoliosis. J Spinal Disord. 2000;13:178–82.PubMedCrossRef
8.
Zurück zum Zitat Hilibrand AS, Schwartz DM, Sethuraman V, Vaccaro AR, Albert TJ. Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery. J Bone Joint Surg Am. 2004;86:1248–53.PubMed Hilibrand AS, Schwartz DM, Sethuraman V, Vaccaro AR, Albert TJ. Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery. J Bone Joint Surg Am. 2004;86:1248–53.PubMed
9.
Zurück zum Zitat Jahangiri FR, Holmberg A, Vega-Bermudez F, Arlet V. Preventing position-related brachial plexus injury with intraoperative somatosensory evoked potentials and transcranial electrical motor evoked potentials during anterior cervical spine surgery. Am J Electroneurodiagnostic Technol. 2011;51(3):198–205.PubMed Jahangiri FR, Holmberg A, Vega-Bermudez F, Arlet V. Preventing position-related brachial plexus injury with intraoperative somatosensory evoked potentials and transcranial electrical motor evoked potentials during anterior cervical spine surgery. Am J Electroneurodiagnostic Technol. 2011;51(3):198–205.PubMed
10.
Zurück zum Zitat Luginbuhl A, Schwartz DM, Sestokas AK, Cognetti D, Pribitkin E. Detection of evolving injury to the brachial plexus during transaxillary robotic thyroidectomy. Laryngoscope. 2012;122(1):110–5. doi:10.1002/lary.22429.PubMedCrossRef Luginbuhl A, Schwartz DM, Sestokas AK, Cognetti D, Pribitkin E. Detection of evolving injury to the brachial plexus during transaxillary robotic thyroidectomy. Laryngoscope. 2012;122(1):110–5. doi:10.​1002/​lary.​22429.PubMedCrossRef
11.
Zurück zum Zitat Sarnthein J, Bozinov O, Melone AG, Bertalanfy H. Motor-evoked potentials (MEP) during brainstem surgery to preserve corticospinal function. Acta Neurochir (Wien). 2011;153(9):1753–9.CrossRef Sarnthein J, Bozinov O, Melone AG, Bertalanfy H. Motor-evoked potentials (MEP) during brainstem surgery to preserve corticospinal function. Acta Neurochir (Wien). 2011;153(9):1753–9.CrossRef
12.
Zurück zum Zitat Parks BJ. Postoperative peripheral neuropathies. Surgery. 1973;74:348–57.PubMed Parks BJ. Postoperative peripheral neuropathies. Surgery. 1973;74:348–57.PubMed
13.
Zurück zum Zitat Uribe JS, Kolla J, Omar H, Dakwar E, Abel N, Mangar D, Camporesi E. Brachial plexus injury following spinal surgery. J Neurosurg Spine. 2010;13(4):552–8.PubMedCrossRef Uribe JS, Kolla J, Omar H, Dakwar E, Abel N, Mangar D, Camporesi E. Brachial plexus injury following spinal surgery. J Neurosurg Spine. 2010;13(4):552–8.PubMedCrossRef
14.
Zurück zum Zitat Cooper DE, Jenkins RS, Bready L, Rockwood CA. The prevention of injuries of the brachial plexus secondary to malposition of the patient during surgery. Clin Orthop Rel Res. 1998;228:33–41. Cooper DE, Jenkins RS, Bready L, Rockwood CA. The prevention of injuries of the brachial plexus secondary to malposition of the patient during surgery. Clin Orthop Rel Res. 1998;228:33–41.
15.
Zurück zum Zitat Lyon R, Lieberman JA, Feiner J, Burch S. Relative efficacy of transcranial motor evoked potentials, mechanically-elicited electromyography, and evoked EMG to assess nerve root function during sustained retraction in a porcine model. Spine (Phila Pa 1976). 2009;34:E558–64.CrossRef Lyon R, Lieberman JA, Feiner J, Burch S. Relative efficacy of transcranial motor evoked potentials, mechanically-elicited electromyography, and evoked EMG to assess nerve root function during sustained retraction in a porcine model. Spine (Phila Pa 1976). 2009;34:E558–64.CrossRef
16.
Zurück zum Zitat Chen Z, Lerman J. Protection of the remaining spinal cord function with intraoperative neurophysiological monitoring during paraparetic scoliosis surgery: a case report. J Clin Monit Comput. 2012;26(1):13–6. doi:10.1007/s10877-011-9325-x.PubMedCrossRef Chen Z, Lerman J. Protection of the remaining spinal cord function with intraoperative neurophysiological monitoring during paraparetic scoliosis surgery: a case report. J Clin Monit Comput. 2012;26(1):13–6. doi:10.​1007/​s10877-011-9325-x.PubMedCrossRef
Metadaten
Titel
Detection of positional brachial plexus injury by radial arterial line during spinal exposure before neuromonitoring confirmation: a retrospective case study
verfasst von
Zhengyong Chen
Leo Chen
Paul Kwon
Michele Montez
Thomas Voegeli
Hans Bueff
Publikationsdatum
01.12.2012
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2012
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-012-9366-9

Weitere Artikel der Ausgabe 6/2012

Journal of Clinical Monitoring and Computing 6/2012 Zur Ausgabe

Beutel versus Maschine: Beste Beatmungstechnik bei Herzstillstand gesucht

02.05.2024 Kardiopulmonale Reanimation Nachrichten

Stehen die Chancen auf eine Rückkehr der Spontanzirkulation nach Herz-Kreislauf-Stillstand bei manueller oder maschineller Beatmung besser? Und unterscheidet sich das neurologische Outcome nach der Reanimation? Das belgische Herzstillstand-Register liefert die Daten für einen direkten Vergleich zwischen Beutel und Beatmungsgerät.

Tipps für den Umgang mit Behandlungsfehlern

01.05.2024 DGIM 2024 Kongressbericht

Es ist nur eine Frage der Zeit, bis es zu einem Zwischenfall kommt und ein Behandlungsfehler passiert. Doch wenn Ärztinnen und Ärzte gut vorbereitet sind, schaffen es alle Beteiligten den Umständen entsprechend gut durch diese Krise. 

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.