Skip to main content
Erschienen in: European Radiology 4/2008

01.04.2008 | Urogenital

Diffusion tensor imaging of the normal prostate at 3 Tesla

verfasst von: Bengi Gürses, Neslihan Kabakci, Arzu Kovanlikaya, Zeynep Firat, Ali Bayram, Aziz Müfit Uluð, İlhami Kovanlikaya

Erschienen in: European Radiology | Ausgabe 4/2008

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to assess the feasibility of diffusion tensor imaging (DTI) of the prostate and to determine normative fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of healthy prostate with a 3-Tesla magnetic resonance imaging (MRI) system. Thirty volunteers with a mean age of 28 (25–35) years were scanned with a 3-Tesla MRI (Intera Achieva; Philips, The Netherlands) system using a six-channel phased array coil. Initially, T2-weighted turbo spin-echo (TSE) axial images of the prostate were obtained. In two subjects, a millimetric hypointense signal change was detected in the peripheral zones on T2-weighted TSE images. These two subjects were excluded from the study. DTI with single-shot echo-planar imaging (ssEPI) was performed in the remaining 28 subjects. ADC and FA values were measured using the manufacturer supplied software by positioning 9-pixel ROIs on each zone. Differences between parameters of the central and peripheral zones were assessed. Mean ADC value of the central (1.220 ± 0.271 × 10−3 mm2/s) was found to be significantly lower when compared with the peripheral gland (1.610 ± 0.347 × 10−3 mm2/s) (P < 0.01). Mean FA of the central gland was significantly higher (0.26), compared with the peripheral gland (0.16) (P < 0.01). This study shows the feasibility of prostate DTI with a 3-Tesla MR system and the normative FA and ADC values of peripheral and central zones of the normal prostate. The results are compatible with the microstructural organization of the gland.
Literatur
1.
2.
Zurück zum Zitat Rouviere O, Hartman RP, Lyonnet D (2006) Prostate MR imaging at high-field strength: evolution or revolution? Eur Radiol 16:276–284PubMedCrossRef Rouviere O, Hartman RP, Lyonnet D (2006) Prostate MR imaging at high-field strength: evolution or revolution? Eur Radiol 16:276–284PubMedCrossRef
3.
Zurück zum Zitat Ikonen S, Kärkkäinen P, Kivisaari L, Salo JO, Taari K, Vehmas T, Tervahartiala P, Rannikko S (2001) Endorectal magnetic resonance imaging of prostatic cancer: comparison between fat-suppressed T2-weighted fast spin echo and three-dimensional dual-echo, steady-state sequences. Eur Radiol 11:236–241PubMedCrossRef Ikonen S, Kärkkäinen P, Kivisaari L, Salo JO, Taari K, Vehmas T, Tervahartiala P, Rannikko S (2001) Endorectal magnetic resonance imaging of prostatic cancer: comparison between fat-suppressed T2-weighted fast spin echo and three-dimensional dual-echo, steady-state sequences. Eur Radiol 11:236–241PubMedCrossRef
4.
Zurück zum Zitat Ikonen S, Kivisaari L, Tervahartiala P, Vehmas T, Taari K, Rannikko S (2001) Prostatic MR imaging. Accuracy in differentiating cancer from other prostatic disorders. Acta Radiol 42:348–354PubMed Ikonen S, Kivisaari L, Tervahartiala P, Vehmas T, Taari K, Rannikko S (2001) Prostatic MR imaging. Accuracy in differentiating cancer from other prostatic disorders. Acta Radiol 42:348–354PubMed
5.
6.
Zurück zum Zitat Shimofusa R, Fujimoto H, Akamata H, Motoori K, Yamamoto S, Ueda T, Ito H (2005) Diffusion-weighted imaging of prostate cancer. J Comput Assist Tomogr 29:149–153PubMedCrossRef Shimofusa R, Fujimoto H, Akamata H, Motoori K, Yamamoto S, Ueda T, Ito H (2005) Diffusion-weighted imaging of prostate cancer. J Comput Assist Tomogr 29:149–153PubMedCrossRef
7.
Zurück zum Zitat Reinsberg SA, Payne GS, Riches SF, Ashley S, Brewster JM, Morgan VA, deSouza NM (2007) Combined use of diffusion-weighted MRI and 1H MR spectroscopy to increase accuracy in prostate cancer detection. AJR Am J Roentgenol 188:91–98PubMedCrossRef Reinsberg SA, Payne GS, Riches SF, Ashley S, Brewster JM, Morgan VA, deSouza NM (2007) Combined use of diffusion-weighted MRI and 1H MR spectroscopy to increase accuracy in prostate cancer detection. AJR Am J Roentgenol 188:91–98PubMedCrossRef
8.
Zurück zum Zitat Issa B (2002) In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging. J Magn Reson Imaging 16:196–200PubMedCrossRef Issa B (2002) In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissues using echo-planar imaging. J Magn Reson Imaging 16:196–200PubMedCrossRef
9.
Zurück zum Zitat Sinha S, Sinha U (2004) In vivo diffusion tensor imaging of the human prostate. Magn Reson Med 52:530–537PubMedCrossRef Sinha S, Sinha U (2004) In vivo diffusion tensor imaging of the human prostate. Magn Reson Med 52:530–537PubMedCrossRef
10.
Zurück zum Zitat Gibbs P, Pickles MD, Turnbull LW (2006) Diffusion imaging of the prostate at 3.0 Tesla. Invest Radiol 41:185–188PubMedCrossRef Gibbs P, Pickles MD, Turnbull LW (2006) Diffusion imaging of the prostate at 3.0 Tesla. Invest Radiol 41:185–188PubMedCrossRef
11.
Zurück zum Zitat Mukherjee P (2005) Diffusion tensor imaging and fiber tractography in acute stroke. Neuroimaging Clin N Am 15:655–665, xiiPubMedCrossRef Mukherjee P (2005) Diffusion tensor imaging and fiber tractography in acute stroke. Neuroimaging Clin N Am 15:655–665, xiiPubMedCrossRef
12.
Zurück zum Zitat Sinha S, Sinha U, Edgerton VR (2006) In vivo diffusion tensor imaging of the human calf muscle. J Magn Reson Imaging 24:182–190PubMedCrossRef Sinha S, Sinha U, Edgerton VR (2006) In vivo diffusion tensor imaging of the human calf muscle. J Magn Reson Imaging 24:182–190PubMedCrossRef
13.
Zurück zum Zitat Cova M, Squillaci E, Stacul F, Manenti G, Gava S, Simonetti G, Pozzi-Mucelli R (2004) Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results. Br J Radiol 77:851–857PubMedCrossRef Cova M, Squillaci E, Stacul F, Manenti G, Gava S, Simonetti G, Pozzi-Mucelli R (2004) Diffusion-weighted MRI in the evaluation of renal lesions: preliminary results. Br J Radiol 77:851–857PubMedCrossRef
14.
Zurück zum Zitat Thoeny HC, De Keyzer F (2007) Extracranial applications of diffusion-weighted magnetic resonance imaging. Eur Radiol 17:1385–1393PubMedCrossRef Thoeny HC, De Keyzer F (2007) Extracranial applications of diffusion-weighted magnetic resonance imaging. Eur Radiol 17:1385–1393PubMedCrossRef
15.
Zurück zum Zitat Padhani AR, Gapinski CJ, Macvicar DA, Parker GJ, Suckling J, Revell PB, Leach MO, Dearnaley DP, Husband JE (2000) Dynamic contrast enhanced MRI of prostate cancer: correlation with morphology and tumour stage, histological grade and PSA. Clin Radiol 55:99–109PubMedCrossRef Padhani AR, Gapinski CJ, Macvicar DA, Parker GJ, Suckling J, Revell PB, Leach MO, Dearnaley DP, Husband JE (2000) Dynamic contrast enhanced MRI of prostate cancer: correlation with morphology and tumour stage, histological grade and PSA. Clin Radiol 55:99–109PubMedCrossRef
16.
Zurück zum Zitat Sato C, Naganawa S, Nakamura T, Kumada H, Miura S, Takizawa O, Ishigaki T (2005) Differentiation of noncancerous tissue and cancer lesions by apparent diffusion coefficient values in transition and peripheral zones of the prostate. J Magn Reson Imaging 21:258–262PubMedCrossRef Sato C, Naganawa S, Nakamura T, Kumada H, Miura S, Takizawa O, Ishigaki T (2005) Differentiation of noncancerous tissue and cancer lesions by apparent diffusion coefficient values in transition and peripheral zones of the prostate. J Magn Reson Imaging 21:258–262PubMedCrossRef
17.
Zurück zum Zitat Pickles MD, Gibbs P, Sreenivas M, Turnbull LW (2006) Diffusion-weighted imaging of normal and malignant prostate tissue at 3.0T. J Magn Reson Imaging 23:130–134PubMedCrossRef Pickles MD, Gibbs P, Sreenivas M, Turnbull LW (2006) Diffusion-weighted imaging of normal and malignant prostate tissue at 3.0T. J Magn Reson Imaging 23:130–134PubMedCrossRef
18.
Zurück zum Zitat Desouza NM, Reinsberg SA, Scurr ED, Brewster JM, Payne GS (2007) Magnetic resonance imaging in prostate cancer: the value of apparent diffusion coefficients for identifying malignant nodules. Br J Radiol 80:90–95PubMedCrossRef Desouza NM, Reinsberg SA, Scurr ED, Brewster JM, Payne GS (2007) Magnetic resonance imaging in prostate cancer: the value of apparent diffusion coefficients for identifying malignant nodules. Br J Radiol 80:90–95PubMedCrossRef
19.
Zurück zum Zitat Haker SJ, Barnes AS, Maier SE et al (2005) Diffusion tensor imaging for prostate cancer detection. In: Proc 13th Annual Meeting ISMRM, Miami Haker SJ, Barnes AS, Maier SE et al (2005) Diffusion tensor imaging for prostate cancer detection. In: Proc 13th Annual Meeting ISMRM, Miami
20.
Zurück zum Zitat Chen AP, Xu D, Henry R et al (2003) Diffusion tensor imaging of the prostate following therapy. In: Proc 11th Annual Meeting ISMRM, Toronto Chen AP, Xu D, Henry R et al (2003) Diffusion tensor imaging of the prostate following therapy. In: Proc 11th Annual Meeting ISMRM, Toronto
21.
Zurück zum Zitat Manenti G, Squillaci E, Di Roma M, Carlani M, Mancino S, Simonetti G (2006) In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissue using thin-slice echo-planar imaging. Radiol Med (Torino) 111:1124–1133CrossRef Manenti G, Squillaci E, Di Roma M, Carlani M, Mancino S, Simonetti G (2006) In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissue using thin-slice echo-planar imaging. Radiol Med (Torino) 111:1124–1133CrossRef
22.
Zurück zum Zitat Miao H, Fukatsu H, Ishigaki T (2007) Prostate cancer detection with 3-T MRI: comparison of diffusion-weighted and T2-weighted imaging. Eur J Radiol 61:297–302PubMedCrossRef Miao H, Fukatsu H, Ishigaki T (2007) Prostate cancer detection with 3-T MRI: comparison of diffusion-weighted and T2-weighted imaging. Eur J Radiol 61:297–302PubMedCrossRef
Metadaten
Titel
Diffusion tensor imaging of the normal prostate at 3 Tesla
verfasst von
Bengi Gürses
Neslihan Kabakci
Arzu Kovanlikaya
Zeynep Firat
Ali Bayram
Aziz Müfit Uluð
İlhami Kovanlikaya
Publikationsdatum
01.04.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-007-0795-7

Weitere Artikel der Ausgabe 4/2008

European Radiology 4/2008 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.