Skip to main content
Erschienen in: European Radiology 8/2003

01.08.2003 | Physics

Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool?

verfasst von: P. Doherty, D. O'Leary, P. C. Brennan

Erschienen in: European Radiology | Ausgabe 8/2003

Einloggen, um Zugang zu erhalten

Abstract.

Increasing beam energies are well established as a radiation dose-reducing tool in diagnostic radiology. This has led to useful recommendations by the Commission of European Communities (CEC) for appropriate kVp values to be employed for a variety of examinations. The current work tests the hypothesis that kVp levels above those recommended by the CEC will result in reduced patient dose while still producing images of acceptable quality. This study explored the effect of a range of kVp levels within and above CEC recommendations for lumbar spine radiology. A phantom investigation facilitated selection of appropriate kVp levels for a patient study (n=59): 81 kVp (CEC) and 96 kVp (non-CEC) for the AP projection and 90 kVp (CEC) and 102 kVp (non-CEC) for the lateral projection. Entrance surface and effective dose were calculated and image quality quantified using CEC image criteria and images of a detail contrast test tool. Data analysis demonstrated significant reduction in effective radiation dose for AP (29.9%) and lateral (24.6%) when a kVp value above the CEC range was employed compared with a kVp recommended by the CEC. Although significant reductions in total image quality of 18.3% and 10.1% for the antero-posterior and lateral projections, respectively, were noted, all patient images produced with all kVp values were considered acceptable by each member of the evaluative panel with all image criteria receiving a score of 2 (out of 3) or better. The psychophysical tests revealed minor non-significant reductions in visualisation scores. The current study demonstrated that kVp values outside the CEC recommended range offer reductions in dose while producing acceptable images. Practitioners should be guided, rather than constrained, by the CEC recommendations on good radiographic technique. The need for further work exploring the effect of higher energies on visualisation of subtle pathological lesions has been identified.
Literatur
1.
Zurück zum Zitat Brennan PC (1995) A dose-reducing examination of the female pelvis. Radiography Today 61:32–35 Brennan PC (1995) A dose-reducing examination of the female pelvis. Radiography Today 61:32–35
2.
Zurück zum Zitat Warren-Forward HM, Millar JS (1995) Optimisation of radiographic technique for chest radiography. Br J Radiol 68:1221–1229PubMed Warren-Forward HM, Millar JS (1995) Optimisation of radiographic technique for chest radiography. Br J Radiol 68:1221–1229PubMed
3.
Zurück zum Zitat Petrone TJ, Steidly KD, Appleby A, Christman E, Haughey F (1996) X-ray beam energy, scatter and radiation risk in chest radiography. Health Phys 70:488–497PubMed Petrone TJ, Steidly KD, Appleby A, Christman E, Haughey F (1996) X-ray beam energy, scatter and radiation risk in chest radiography. Health Phys 70:488–497PubMed
4.
Zurück zum Zitat Papageorgiou E, Vardalaki E, Hourdakis CJ, Dimitriou P (2001) Estimation of doses received by patients undergoing radiological examinations in Greece. Radiat Prot Dosimetry 93:31–41PubMed Papageorgiou E, Vardalaki E, Hourdakis CJ, Dimitriou P (2001) Estimation of doses received by patients undergoing radiological examinations in Greece. Radiat Prot Dosimetry 93:31–41PubMed
5.
Zurück zum Zitat Fung K (1995) Lowering patient dose on single phase X-ray units. Radiol Technol 66:159–164PubMed Fung K (1995) Lowering patient dose on single phase X-ray units. Radiol Technol 66:159–164PubMed
6.
Zurück zum Zitat Almen A, Tingberg A, Mattsson S, Besjakov J, Kheddache S, Lanhede B, Zankl M (2000) The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria. Br J Radiol 73:1192–1999PubMed Almen A, Tingberg A, Mattsson S, Besjakov J, Kheddache S, Lanhede B, Zankl M (2000) The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria. Br J Radiol 73:1192–1999PubMed
7.
Zurück zum Zitat Vano E, Oliete S, Gonzalez L, Guibelalde E, Velasco A, Fernandez JM (1995) Image quality and dose in lumbar spine examinations: results of a 5-year quality control programme following the European Quality criteria trial. Br J Radiol 68:1332–1335PubMed Vano E, Oliete S, Gonzalez L, Guibelalde E, Velasco A, Fernandez JM (1995) Image quality and dose in lumbar spine examinations: results of a 5-year quality control programme following the European Quality criteria trial. Br J Radiol 68:1332–1335PubMed
8.
Zurück zum Zitat Otriz P, Maccia C, Padovani R, Vano E, Carlsson A, Schibilla H (1995) Results of the IAEA–CEC coordinated research programme on radiation doses in diagnostic radiology and methods for reduction. Radiat Prot Dosimetry 57:95–9 Otriz P, Maccia C, Padovani R, Vano E, Carlsson A, Schibilla H (1995) Results of the IAEA–CEC coordinated research programme on radiation doses in diagnostic radiology and methods for reduction. Radiat Prot Dosimetry 57:95–9
9.
Zurück zum Zitat Nishikawa K, Shibuya H, Wakoh M, Kuroyanagi K (1999) Dependency of dose response of percent charge-coupled device based digital intra-oral radiographic systems on tube voltage. Dentomaxillofac Radiol 28:364–367CrossRefPubMed Nishikawa K, Shibuya H, Wakoh M, Kuroyanagi K (1999) Dependency of dose response of percent charge-coupled device based digital intra-oral radiographic systems on tube voltage. Dentomaxillofac Radiol 28:364–367CrossRefPubMed
10.
Zurück zum Zitat Mooney R, Thomas PS (1998) Dose reduction in a paediatric X-ray department following optimisation of radiographic technique. Br J Radiol 71:852–860PubMed Mooney R, Thomas PS (1998) Dose reduction in a paediatric X-ray department following optimisation of radiographic technique. Br J Radiol 71:852–860PubMed
11.
Zurück zum Zitat McParland BJ, Gorka W, Lee R, Lewall DB, Omojola MF (1996) Radiology in the neonatal intensive care unit: dose reduction and image quality. Br J Radiol 69:929–937PubMed McParland BJ, Gorka W, Lee R, Lewall DB, Omojola MF (1996) Radiology in the neonatal intensive care unit: dose reduction and image quality. Br J Radiol 69:929–937PubMed
12.
Zurück zum Zitat Commission of European Communities (1996. European guidelines on Quality Criteria for Diagnostic Radiographic Images. The European Commission. EUR 16260 EN Commission of European Communities (1996. European guidelines on Quality Criteria for Diagnostic Radiographic Images. The European Commission. EUR 16260 EN
13.
Zurück zum Zitat National Radiation Protection Board (NRPB) (1994) Estimation of effective dose in diagnostic radiology from entrance surface dose and dose area product measurements. Chilton, Didcot and Oxon, NRPB-R262 Document National Radiation Protection Board (NRPB) (1994) Estimation of effective dose in diagnostic radiology from entrance surface dose and dose area product measurements. Chilton, Didcot and Oxon, NRPB-R262 Document
14.
Zurück zum Zitat Brennan PC (1995) The validity of an anthropomorphic phantom for simulating patients in estimating radiation dose in controlled and experimental conditions. Proc 10th European–African Conference of the ISSRT, p 54 Brennan PC (1995) The validity of an anthropomorphic phantom for simulating patients in estimating radiation dose in controlled and experimental conditions. Proc 10th European–African Conference of the ISSRT, p 54
15.
Zurück zum Zitat National Radiation Protection Board (NRPB) (1992) National protocol for patient dose measurements in diagnostic radiology. Chilton, Didcot and Oxon, NRPB Document National Radiation Protection Board (NRPB) (1992) National protocol for patient dose measurements in diagnostic radiology. Chilton, Didcot and Oxon, NRPB Document
16.
Zurück zum Zitat Brennan PC, Madigan E (2000) Lumbar spine radiology: analysis of the posteroanterior projection. Eur Radiol 69:1197–1201CrossRef Brennan PC, Madigan E (2000) Lumbar spine radiology: analysis of the posteroanterior projection. Eur Radiol 69:1197–1201CrossRef
17.
Zurück zum Zitat Sokal RR, Rohlf FJ (1981) Biometry: the principles and practises of statistics in biological research. Butterworth Heinmann, San Francisco Sokal RR, Rohlf FJ (1981) Biometry: the principles and practises of statistics in biological research. Butterworth Heinmann, San Francisco
18.
Zurück zum Zitat Brennan PC, Johnston D (2002) Irish X-ray departments demonstrate varying levels of adherence to European guidelines on good radiographic technique. Br J Radiol 75:243–248PubMed Brennan PC, Johnston D (2002) Irish X-ray departments demonstrate varying levels of adherence to European guidelines on good radiographic technique. Br J Radiol 75:243–248PubMed
19.
Zurück zum Zitat Brennan PC, Nash M (1998) Increasing FFD: an effective dose reducing tool for lateral lumbar spine investigations. Radiography 4:195–203 Brennan PC, Nash M (1998) Increasing FFD: an effective dose reducing tool for lateral lumbar spine investigations. Radiography 4:195–203
20.
Zurück zum Zitat Martin CJ, Darragh CL, McKenzie GA, Bayliss AP (1993) Implementation of a programme for the reduction of radiographic doses and results achieved through increases in tube potential. Br J Radiol 66:228–233PubMed Martin CJ, Darragh CL, McKenzie GA, Bayliss AP (1993) Implementation of a programme for the reduction of radiographic doses and results achieved through increases in tube potential. Br J Radiol 66:228–233PubMed
21.
Zurück zum Zitat Wilks RJ (1987) Principles of radiological physics, 2nd edn. Churchill Livingstone, Edinburgh Wilks RJ (1987) Principles of radiological physics, 2nd edn. Churchill Livingstone, Edinburgh
22.
Zurück zum Zitat National Radiation Protection Board (NRPB) (2002) Radiation exposure of the UK population from medical and dental X-ray examinations. Chilton, Didcot and Oxon, NRPB-W4 Document National Radiation Protection Board (NRPB) (2002) Radiation exposure of the UK population from medical and dental X-ray examinations. Chilton, Didcot and Oxon, NRPB-W4 Document
Metadaten
Titel
Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool?
verfasst von
P. Doherty
D. O'Leary
P. C. Brennan
Publikationsdatum
01.08.2003
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 8/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-002-1810-7

Weitere Artikel der Ausgabe 8/2003

European Radiology 8/2003 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.