Purpose

Incisional hernia is the most common complication following abdominal surgery. While mesh repair is common, none of the current meshes mimic the physiology of the abdominal wall. This study compares suture only repair with polypropylene mesh and a prototype of a novel implant (poly-epsilon-caprolactone nanofibers) and their influence on the physiology of an abdominal wall in an animal model.

Methods

27 Chinchilla rabbits were divided into six groups based on the type of the implant. Midline abdominal incision was repaired using one of the compared materials with suture alone serving as the control. 6 weeks post-surgery animals were killed and their explanted abdominal wall subjected to biomechanical testing.

Results

Both—hysteresis and maximum strength curves showed high elasticity and strength in groups where the novel implant was used. Polypropylene mesh proved as stiff and fragile compared to other groups.

Conclusion

Poly-epsilon-caprolactone nanofiber scaffold is able to improve the dynamic properties of healing fascia with no loss of maximum tensile strength when compared to polypropylene mesh in an animal model.
Literatur
1.
Zurück zum Zitat Meijer EJ, Timmermans L et al. The principles of abdominal wound closure. Acta Chir Belg. 2013;113(4):239–44.CrossRefPubMed Meijer EJ, Timmermans L et al. The principles of abdominal wound closure. Acta Chir Belg. 2013;113(4):239–44.CrossRefPubMed
2.
Zurück zum Zitat Luijendijk RW, Hop WC et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398CrossRefPubMed Luijendijk RW, Hop WC et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398CrossRefPubMed
3.
Zurück zum Zitat Muysoms FE, Antoniou SA et al (2015) European Hernia Society guidelines on the closure of abdominal wall incisions. Hernia 19(1):1–24CrossRefPubMed Muysoms FE, Antoniou SA et al (2015) European Hernia Society guidelines on the closure of abdominal wall incisions. Hernia 19(1):1–24CrossRefPubMed
4.
Zurück zum Zitat Azimi B, Nourpanah P et al (2014) Poly (ε-caprolactone) fiber: an overview. J Eng Fibers Fabr 9(3):74–90 Azimi B, Nourpanah P et al (2014) Poly (ε-caprolactone) fiber: an overview. J Eng Fibers Fabr 9(3):74–90
5.
Zurück zum Zitat Weyhe D, Belyaev O et al (2007) Improving outcomes in hernia repair by the use of light meshes—a comparison of different implant constructions based on a critical appraisal of the literature. World J Surg 31:234–244CrossRefPubMed Weyhe D, Belyaev O et al (2007) Improving outcomes in hernia repair by the use of light meshes—a comparison of different implant constructions based on a critical appraisal of the literature. World J Surg 31:234–244CrossRefPubMed
6.
Zurück zum Zitat Bringman S, Conze J et al (2010) Hernia repair: the search for ideal meshes. Hernia 14:81–87CrossRefPubMed Bringman S, Conze J et al (2010) Hernia repair: the search for ideal meshes. Hernia 14:81–87CrossRefPubMed
7.
Zurück zum Zitat Venugopal J, Low S et al (2008) Interaction of cells and nanofiber scaffolds in tissue engineering. J Biomed Mater Res B Appl Biomater 84:34–48CrossRefPubMed Venugopal J, Low S et al (2008) Interaction of cells and nanofiber scaffolds in tissue engineering. J Biomed Mater Res B Appl Biomater 84:34–48CrossRefPubMed
8.
Zurück zum Zitat Rampichova M, Chvojka J et al (2012) Elastic three-dimensional poly (ε-caprolactone) nanofibre scaffold enhances migration, proliferation and osteogenic differentiation of mesenchymal stem cells. Cell Prolif 46:23–37CrossRefPubMedPubMedCentral Rampichova M, Chvojka J et al (2012) Elastic three-dimensional poly (ε-caprolactone) nanofibre scaffold enhances migration, proliferation and osteogenic differentiation of mesenchymal stem cells. Cell Prolif 46:23–37CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Velayudhan S, Martin D et al (2009) Evaluation of dynamic creep properties of surgical mesh prostheses—uniaxial fatigue. J Biomed Mater Res B Appl Biomater 5:287–296CrossRef Velayudhan S, Martin D et al (2009) Evaluation of dynamic creep properties of surgical mesh prostheses—uniaxial fatigue. J Biomed Mater Res B Appl Biomater 5:287–296CrossRef
10.
Zurück zum Zitat El Fray M, Prowans P et al (2006) Biocompatibility and fatigue properties of polystyrene-polyisobutylene–polystyrene, an emerging thermoplastic elastomeric biomaterial. Biomacromolecules 7:844–850CrossRefPubMed El Fray M, Prowans P et al (2006) Biocompatibility and fatigue properties of polystyrene-polyisobutylene–polystyrene, an emerging thermoplastic elastomeric biomaterial. Biomacromolecules 7:844–850CrossRefPubMed
11.
Zurück zum Zitat El Fray M, Altstadt V. Fatigue behaviour of multiblock thermoplastic elastomers. II. Dynamic creep of poly(aliphatic/aromatic-ester) copolymers. Polymer 2003;44:4643–50.CrossRef El Fray M, Altstadt V. Fatigue behaviour of multiblock thermoplastic elastomers. II. Dynamic creep of poly(aliphatic/aromatic-ester) copolymers. Polymer 2003;44:4643–50.CrossRef
12.
Zurück zum Zitat Lukas D, Sarkar A et al (2009) Physical principles of electrospinning (electrospinning as a nano-scale technology of the twenty-first century). Textile Progress 41:1–83CrossRef Lukas D, Sarkar A et al (2009) Physical principles of electrospinning (electrospinning as a nano-scale technology of the twenty-first century). Textile Progress 41:1–83CrossRef
13.
Zurück zum Zitat Klinge U, Conze J et al (1996) Pathophysiology of the abdominal wall. Chirurg 67(3):229–233PubMed Klinge U, Conze J et al (1996) Pathophysiology of the abdominal wall. Chirurg 67(3):229–233PubMed
14.
Zurück zum Zitat Eliason BJ, Frisella MM et al. Effect of repetitive loading on the mechanical properties of synthetic hernia repair materials. J Am Coll Surg. 2011;213(3):430–35.CrossRefPubMed Eliason BJ, Frisella MM et al. Effect of repetitive loading on the mechanical properties of synthetic hernia repair materials. J Am Coll Surg. 2011;213(3):430–35.CrossRefPubMed
15.
Zurück zum Zitat Bhardway N, Kundu SC (2010) Electrospinning: a fascinating fiber fabrication technique. Biotechnol Adv 28:325–347CrossRef Bhardway N, Kundu SC (2010) Electrospinning: a fascinating fiber fabrication technique. Biotechnol Adv 28:325–347CrossRef
16.
Zurück zum Zitat Place ES, George JH et al (2009) Synthetic polymer scaffolds for tissue engineering. Chem Soc Rev 38:1139–1151CrossRefPubMed Place ES, George JH et al (2009) Synthetic polymer scaffolds for tissue engineering. Chem Soc Rev 38:1139–1151CrossRefPubMed
17.
Zurück zum Zitat Li WJ, Danielson KG et al (2003) Biological response of chondrocytes cultured in three-dimensional nanofibrous poly(e-caprolactone) scaffolds. J Biomed Mater Res A. 67:1105–1114CrossRefPubMed Li WJ, Danielson KG et al (2003) Biological response of chondrocytes cultured in three-dimensional nanofibrous poly(e-caprolactone) scaffolds. J Biomed Mater Res A. 67:1105–1114CrossRefPubMed
18.
Zurück zum Zitat Li WJ, Jiang YJ, Tuan RS (2006) Chondrocyte phenotype in engineered fibrous matrix is regulated by fiber size. Tissue Eng. 12:1775–1785CrossRefPubMed Li WJ, Jiang YJ, Tuan RS (2006) Chondrocyte phenotype in engineered fibrous matrix is regulated by fiber size. Tissue Eng. 12:1775–1785CrossRefPubMed
19.
Zurück zum Zitat Ma Z, Kotaki M et al (2005) Potential of nanofiber matrix as tissue-engineering scaffolds. Tissue Eng 11:101–109CrossRefPubMed Ma Z, Kotaki M et al (2005) Potential of nanofiber matrix as tissue-engineering scaffolds. Tissue Eng 11:101–109CrossRefPubMed
20.
Zurück zum Zitat Agarwal S, Wendorff JH et al (2008) Use of electrospinning technique for biomedical applications. Polymer 49:5603–5621CrossRef Agarwal S, Wendorff JH et al (2008) Use of electrospinning technique for biomedical applications. Polymer 49:5603–5621CrossRef
21.
Zurück zum Zitat Plencner M, East B et al. Abdominal closure reinforcement by using polypropylene mesh functionalized with poly-ε-caprolactone nanofibers and growth factors for prevention of incisional hernia formation. Int J Nanomed. 2014;9:3263–77 Plencner M, East B et al. Abdominal closure reinforcement by using polypropylene mesh functionalized with poly-ε-caprolactone nanofibers and growth factors for prevention of incisional hernia formation. Int J Nanomed. 2014;9:3263–77
22.
Zurück zum Zitat Chen M, Patra PK et al (2007) Role of fiber diameter in adhesion and proliferation of NIH 3T3 fibroblast on electrospun polycaprolactone scaffolds. Tissue Eng 13:579–587CrossRefPubMed Chen M, Patra PK et al (2007) Role of fiber diameter in adhesion and proliferation of NIH 3T3 fibroblast on electrospun polycaprolactone scaffolds. Tissue Eng 13:579–587CrossRefPubMed
23.
Zurück zum Zitat Sanders JE, Stiles CE et al (2000) Tissue response to single-polymer fibers of varying diameters: evaluation of fibrous encapsulation and macrophage density. J Biomed Mater Res 52:231–237CrossRefPubMed Sanders JE, Stiles CE et al (2000) Tissue response to single-polymer fibers of varying diameters: evaluation of fibrous encapsulation and macrophage density. J Biomed Mater Res 52:231–237CrossRefPubMed
24.
Zurück zum Zitat Marimuthu M, Kim S (2009) Survey of the state of the art in biomaterials, cells, genes and proteins integrated into micro- and nanoscaffolds for tissue regeneration. Curr Nanosci. 5:189–203CrossRef Marimuthu M, Kim S (2009) Survey of the state of the art in biomaterials, cells, genes and proteins integrated into micro- and nanoscaffolds for tissue regeneration. Curr Nanosci. 5:189–203CrossRef
25.
Zurück zum Zitat Burger JWA, Luijendijk RW et al (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240(4):578–585PubMedPubMedCentral Burger JWA, Luijendijk RW et al (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240(4):578–585PubMedPubMedCentral
Metadaten
Titel
Dynamic creep properties of a novel nanofiber hernia mesh in abdominal wall repair
verfasst von
B. East
M. Plencner
M. Otahal
E. Amler
A. C. de Beaux
Publikationsdatum
05.04.2019
Verlag
Springer Paris
Erschienen in
Hernia / Ausgabe 5/2019
Print ISSN: 1265-4906
Elektronische ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-019-01940-w

Weitere Artikel der Ausgabe 5/2019

Hernia 5/2019 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.