Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 7/2020

20.05.2020 | Original Article

Dynamic path planning for percutaneous procedures in the abdomen during free breathing

verfasst von: Danial Pour Arab, Sandrine Voros, Caroline Essert

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 7/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Percutaneous procedures are increasingly used for the treatment of tumors in abdominal structures. Most of the time, these procedures are planned based on static preoperative images and do not take into account any motions, while breathing control is not always applicable. In this paper, we present a method to automatically adjust the planned path in real time according to the breathing.

Methods

First, an estimation of the organs motions during breathing is performed during an observation phase. Then we propose an approach named Real Time Intelligent Trajectory (RTIT) that consists in finding the most appropriate moments to push the needle along the initially planned path, based on the motions and the distance to surrounding organs. We also propose a second approach called Real Time Straight Trajectory (RTST) that examines sixteen scenarios of needle insertion at constant speed, starting at eight different moments of the breathing cycle with two different speeds.

Results

We evaluated our methods on six 3D models of abdominal structures built using image datasets and a real-time simulation of breathing movements. We measured the deviation from the initial path, the target positioning error, and the distance of the actual path to risky structures. The path proposed by RTIT approach is compared to the best path proposed by RTST.

Conclusions

We show that the RTIT approach is relevant and adapted to breathing movements. The modification of the path remains minimal while collisions with obstacles are avoided. This study on simulations constitutes a first step towards intelligent robotic insertion under real-time image guidance.
Literatur
1.
Zurück zum Zitat Liang P, Wang Y (2007) Microwave ablation of hepatocellular carcinoma. Oncology 72(Suppl. 1):124–131CrossRef Liang P, Wang Y (2007) Microwave ablation of hepatocellular carcinoma. Oncology 72(Suppl. 1):124–131CrossRef
2.
Zurück zum Zitat Maybody M, Solomon SB (2007) Image-guided percutaneous cryoablation of renal tumors. Tech Vasc Interv Radiol 10(2):140–148CrossRef Maybody M, Solomon SB (2007) Image-guided percutaneous cryoablation of renal tumors. Tech Vasc Interv Radiol 10(2):140–148CrossRef
3.
Zurück zum Zitat Georgiades CS, Hong K, Bizzell C, Geschwind JF, Rodriguez R (2008) Safety and efficacy of CT-guided percutaneous cryoablation for renal cell carcinoma. J Vasc Interv Radiol 19(9):1302–1310CrossRef Georgiades CS, Hong K, Bizzell C, Geschwind JF, Rodriguez R (2008) Safety and efficacy of CT-guided percutaneous cryoablation for renal cell carcinoma. J Vasc Interv Radiol 19(9):1302–1310CrossRef
4.
Zurück zum Zitat Maeda M, Saeki I, Sakaida I, Aikata H, Araki Y, Ogawa C, Kariyama K, Nouso K, Kitamoto M, Kobashi H, Sato S, Shibata H, Joko K, Takaki S, Takabatake H, Tsutsui A, Takaguchi K, Tomonari T, Nakamura S, Nagahara T, Hiraoka A, Matono T, Koda M, Mandai M, Mannami T, Mitsuda A, Moriya T, Yabushita K, Tani J, Yagi T, Yamasaki T (2020) Complications after radiofrequency ablation for hepatocellular carcinoma: a multicenter study involving 9,411 japanese patients. Liver Cancer 9(1):50–62CrossRef Maeda M, Saeki I, Sakaida I, Aikata H, Araki Y, Ogawa C, Kariyama K, Nouso K, Kitamoto M, Kobashi H, Sato S, Shibata H, Joko K, Takaki S, Takabatake H, Tsutsui A, Takaguchi K, Tomonari T, Nakamura S, Nagahara T, Hiraoka A, Matono T, Koda M, Mandai M, Mannami T, Mitsuda A, Moriya T, Yabushita K, Tani J, Yagi T, Yamasaki T (2020) Complications after radiofrequency ablation for hepatocellular carcinoma: a multicenter study involving 9,411 japanese patients. Liver Cancer 9(1):50–62CrossRef
5.
Zurück zum Zitat Bale R, Schullian P, Eberle G, Putzer D, Zoller H, Schneeberger S, Manzl C, Moser P, Oberhuber G (2019) Stereotactic radiofrequency ablation of hepatocellular carcinoma: a histopathological study in explanted livers. Hepatology 70(3):840–850CrossRef Bale R, Schullian P, Eberle G, Putzer D, Zoller H, Schneeberger S, Manzl C, Moser P, Oberhuber G (2019) Stereotactic radiofrequency ablation of hepatocellular carcinoma: a histopathological study in explanted livers. Hepatology 70(3):840–850CrossRef
6.
Zurück zum Zitat Engstrand J, Toporek G, Harbut P, Jonas E, Nilsson H, Freedman J (2017) Stereotactic CT-guided percutaneous microwave ablation of liver tumors with the use of high-frequency jet ventilation: an accuracy and procedural safety study. Am J Roentgenol 208(1):193–200CrossRef Engstrand J, Toporek G, Harbut P, Jonas E, Nilsson H, Freedman J (2017) Stereotactic CT-guided percutaneous microwave ablation of liver tumors with the use of high-frequency jet ventilation: an accuracy and procedural safety study. Am J Roentgenol 208(1):193–200CrossRef
7.
Zurück zum Zitat Mulier S, Ni Y, Jamart J, Ruers T, Marchal G, Michel L (2005) Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors. Ann Surg 242(2):158CrossRef Mulier S, Ni Y, Jamart J, Ruers T, Marchal G, Michel L (2005) Local recurrence after hepatic radiofrequency coagulation: multivariate meta-analysis and review of contributing factors. Ann Surg 242(2):158CrossRef
8.
Zurück zum Zitat Baegert C, Villard C, Schreck P, Soler L (2007) Multi-criteria trajectory planning for hepatic radiofrequency ablation. In: Proceedings of MICCAI’07, Springer LNCS, vol 4791, pp 584–592 Baegert C, Villard C, Schreck P, Soler L (2007) Multi-criteria trajectory planning for hepatic radiofrequency ablation. In: Proceedings of MICCAI’07, Springer LNCS, vol 4791, pp 584–592
9.
Zurück zum Zitat Baegert C, Villard C, Schreck P, Soler L, Gangi A (2007) Trajectory optimization for the planning of percutaneous radiofrequency ablation of hepatic tumors. Comput Aided Surg 12(2):82–90CrossRef Baegert C, Villard C, Schreck P, Soler L, Gangi A (2007) Trajectory optimization for the planning of percutaneous radiofrequency ablation of hepatic tumors. Comput Aided Surg 12(2):82–90CrossRef
10.
Zurück zum Zitat Seitel A, Engel M, Sommer C, Redeleff B, Essert-Villard C, Baegert C, Fangerau M, Fritzsche K, Yung K, Meinzer HP, Maier-Hein L (2011) Computer-assisted trajectory planning for percutaneous needle insertions. Med Phys 38(6):3246–3260CrossRef Seitel A, Engel M, Sommer C, Redeleff B, Essert-Villard C, Baegert C, Fangerau M, Fritzsche K, Yung K, Meinzer HP, Maier-Hein L (2011) Computer-assisted trajectory planning for percutaneous needle insertions. Med Phys 38(6):3246–3260CrossRef
11.
Zurück zum Zitat Schumann C, Bieberstein J, Trumm C, Schmidt D, Bruners P, Niethammer M, Hoffmann R, Mahnken A, Pereira P, Peitgen H (2010) Fast automatic path proposal computation for hepatic needle placement. In: SPIE medical imaging, vol 7625, p 76251J Schumann C, Bieberstein J, Trumm C, Schmidt D, Bruners P, Niethammer M, Hoffmann R, Mahnken A, Pereira P, Peitgen H (2010) Fast automatic path proposal computation for hepatic needle placement. In: SPIE medical imaging, vol 7625, p 76251J
12.
Zurück zum Zitat März K, Franz AM, Stieltjes B, Iszatt J, Seitel A, Radeleff B, Meinzer HP, Maier-Hein L (2013) Mobile EM field generator for ultrasound guided navigated needle insertions. In: Proceedings of the 4th international conference on information processing in computer-assisted interventions, IPCAI’13, pp 71–80 März K, Franz AM, Stieltjes B, Iszatt J, Seitel A, Radeleff B, Meinzer HP, Maier-Hein L (2013) Mobile EM field generator for ultrasound guided navigated needle insertions. In: Proceedings of the 4th international conference on information processing in computer-assisted interventions, IPCAI’13, pp 71–80
13.
Zurück zum Zitat Stoll M, Boettger M, Schulze C, Hastenteufel M (2012) Transfer of methods from radiotherapy planning to ablation planning with focus on uncertainties and robustness. Biomed Eng Biomed Tech 57(SI–1 Track–C):901–904 Stoll M, Boettger M, Schulze C, Hastenteufel M (2012) Transfer of methods from radiotherapy planning to ablation planning with focus on uncertainties and robustness. Biomed Eng Biomed Tech 57(SI–1 Track–C):901–904
14.
Zurück zum Zitat Villard C, Soler L, Papier N, Agnus V, Gangi A, Mutter D, Marescaux J (2003) RF-Sim: a treatment planning tool for radiofrequency ablation of hepatic tumors. In: Proceedings of information visualization. IEEE Computer Society Press, pp 561–566 Villard C, Soler L, Papier N, Agnus V, Gangi A, Mutter D, Marescaux J (2003) RF-Sim: a treatment planning tool for radiofrequency ablation of hepatic tumors. In: Proceedings of information visualization. IEEE Computer Society Press, pp 561–566
15.
Zurück zum Zitat Hamzé N, Peterlík I, Cotin S, Essert C (2016) Preoperative trajectory planning for percutaneous procedures in deformable environments. Comput Med Imaging Graph 47:16–28CrossRef Hamzé N, Peterlík I, Cotin S, Essert C (2016) Preoperative trajectory planning for percutaneous procedures in deformable environments. Comput Med Imaging Graph 47:16–28CrossRef
16.
Zurück zum Zitat Li P, Jiang S, Liang D, Yang Z, Yu Y, Wang W (2017) Modeling of path planning and needle steering with path tracking in anatomical soft tissues for minimally invasive surgery. Med Eng Phys 41:35–45CrossRef Li P, Jiang S, Liang D, Yang Z, Yu Y, Wang W (2017) Modeling of path planning and needle steering with path tracking in anatomical soft tissues for minimally invasive surgery. Med Eng Phys 41:35–45CrossRef
17.
Zurück zum Zitat Shahriari N, Georgiadis JR, Oudkerk M, Misra S (2018) Hybrid control algorithm for flexible needle steering: demonstration in phantom and human cadaver. PloS One 13(12):e0210052CrossRef Shahriari N, Georgiadis JR, Oudkerk M, Misra S (2018) Hybrid control algorithm for flexible needle steering: demonstration in phantom and human cadaver. PloS One 13(12):e0210052CrossRef
18.
Zurück zum Zitat Vrooijink GJ, Abayazid M, Patil S, Alterovitz R, Misra S (2014) Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images. Int J Robot Res 33(10):1361–1374CrossRef Vrooijink GJ, Abayazid M, Patil S, Alterovitz R, Misra S (2014) Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images. Int J Robot Res 33(10):1361–1374CrossRef
19.
Zurück zum Zitat Patil S, Alterovitz R (2010) Interactive motion planning for steerable needles in 3D environments with obstacles. In: 2010 3rd IEEE RAS & EMBS international conference on biomedical robotics and biomechatronics. IEEE, pp 893–899 Patil S, Alterovitz R (2010) Interactive motion planning for steerable needles in 3D environments with obstacles. In: 2010 3rd IEEE RAS & EMBS international conference on biomedical robotics and biomechatronics. IEEE, pp 893–899
20.
Zurück zum Zitat Bernardes M, Adorno BV, Poignet P, Borges G (2013) Robot-assisted automatic insertion of steerable needles with closed-loop imaging feedback and intraoperative trajectory replanning. Mechatronics 23(6):630–645CrossRef Bernardes M, Adorno BV, Poignet P, Borges G (2013) Robot-assisted automatic insertion of steerable needles with closed-loop imaging feedback and intraoperative trajectory replanning. Mechatronics 23(6):630–645CrossRef
21.
Zurück zum Zitat Lapouge G, Troccaz J, Poignet P (2018) Multi-rate unscented Kalman filtering for pose and curvature estimation in 3D ultrasound-guided needle steering. Control Eng Pract 80:116–124CrossRef Lapouge G, Troccaz J, Poignet P (2018) Multi-rate unscented Kalman filtering for pose and curvature estimation in 3D ultrasound-guided needle steering. Control Eng Pract 80:116–124CrossRef
22.
Zurück zum Zitat Zhou K, Hou Q, Wang R, Guo B (2008) Real-time KD-tree construction on graphics hardware. ACM Trans Graph (TOG) 27(5):1–11CrossRef Zhou K, Hou Q, Wang R, Guo B (2008) Real-time KD-tree construction on graphics hardware. ACM Trans Graph (TOG) 27(5):1–11CrossRef
23.
Zurück zum Zitat Fouard C, Deram A, Keraval Y, Promayon E (2012) CamiTK: a modular framework integrating visualization, image processing and biomechanical modeling. In: Payan Y (ed) Soft tissue biomechanical modeling for computer assisted surgery, pp 323–354. https://doi.org/10.1007/8415_2012_118 Fouard C, Deram A, Keraval Y, Promayon E (2012) CamiTK: a modular framework integrating visualization, image processing and biomechanical modeling. In: Payan Y (ed) Soft tissue biomechanical modeling for computer assisted surgery, pp 323–354. https://​doi.​org/​10.​1007/​8415_​2012_​118
25.
Zurück zum Zitat Lin SM (2009) Recent advances in radiofrequency ablation in the treatment of hepatocellular carcinoma and metastatic liver cancers. Chang Gung Med J 32(1):22–32PubMed Lin SM (2009) Recent advances in radiofrequency ablation in the treatment of hepatocellular carcinoma and metastatic liver cancers. Chang Gung Med J 32(1):22–32PubMed
26.
Zurück zum Zitat Cannon R, Ellis S, Hayes D, Narayanan G, Martin RC (2013) Safety and early efficacy of irreversible electroporation for hepatic tumors in proximity to vital structures. J Surg Oncol 107(5):544–549CrossRef Cannon R, Ellis S, Hayes D, Narayanan G, Martin RC (2013) Safety and early efficacy of irreversible electroporation for hepatic tumors in proximity to vital structures. J Surg Oncol 107(5):544–549CrossRef
Metadaten
Titel
Dynamic path planning for percutaneous procedures in the abdomen during free breathing
verfasst von
Danial Pour Arab
Sandrine Voros
Caroline Essert
Publikationsdatum
20.05.2020
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 7/2020
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-020-02153-8

Weitere Artikel der Ausgabe 7/2020

International Journal of Computer Assisted Radiology and Surgery 7/2020 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.