Effect of corneal marking features on toric intraocular lens alignment

verfasst von: Hasan Aytogan

Erschienen in: International Ophthalmology | Ausgabe 7/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to investigate the relation of the corneal ink mark size, shape, and location with the corneal perimeter in terms of the corresponding corneal axis.

Material and methods

This study was designed both prospective experimental and literature search. Contact lenses were used to demonstrate the spreading effect of the surgical ink mark. Open-access published corneal images with corneal ink marks were reviewed. Mark size and perimeter of both contact lenses and corneal images were performed in Image J software.

Results

Twenty contact lenses and 15 corneal images with 32 corneal marks, which were obtained from the literature, were included in the study. Mean degree corresponding to the ink size for the group 1 was 8.3° ± 1.2° (range 5.5–10.3), for group 2 was 11° ± 1.1° (range 8–12), for group 3 was 4.2° ± 0.7° (range 3.2–5.5), for group 4 was 4.2° ± 0.7° (range 3.2–5.5), and for group 5 was 6.3° ± 2.5° (range 2–11.5).

Discussion

Theoretically, it is wise to target further located ink mark from central cornea based on the 360/2π × (r2 − r1)/(r1 × r2) × M formula. It has been experimentally shown that the smaller corneal perimeter and closer mark to the central cornea may lead the more significant deviation from the targeted axis. Preoperative manual corneal marking may be more responsible for residual astigmatism than it is thought.
Literatur
1.
Zurück zum Zitat Hoffmann PC, Hütz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485CrossRef Hoffmann PC, Hütz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485CrossRef
3.
Zurück zum Zitat Mohammadi M, Naderan M, Pahlevani R, Jahanrad A (2016) Prevalence of corneal astigmatism before cataract surgery. Int Ophthalmol 36:807–817CrossRef Mohammadi M, Naderan M, Pahlevani R, Jahanrad A (2016) Prevalence of corneal astigmatism before cataract surgery. Int Ophthalmol 36:807–817CrossRef
4.
Zurück zum Zitat Lane SS, Ernest P, Miller KM, Hileman KS, Harris B, Waycaster CR (2009) Comparison of clinical and patient-reported outcomes with bilateral AcrySof toric or spherical control intraocular lenses. J Refract Surg 25:899–901CrossRef Lane SS, Ernest P, Miller KM, Hileman KS, Harris B, Waycaster CR (2009) Comparison of clinical and patient-reported outcomes with bilateral AcrySof toric or spherical control intraocular lenses. J Refract Surg 25:899–901CrossRef
6.
Zurück zum Zitat Carey PJ, Leccisotti A, McGilligan VE, Goodall EA, Moore CBT (2010) Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation. J Cataract Refract Surg 36:222–229CrossRef Carey PJ, Leccisotti A, McGilligan VE, Goodall EA, Moore CBT (2010) Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation. J Cataract Refract Surg 36:222–229CrossRef
7.
Zurück zum Zitat Visser N, Berendschot TTJM, Bauer NJC, Jurich J, Kersting O, Nuijts RMMA (2011) Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J Cataract Refract Surg 37:1394–1402CrossRef Visser N, Berendschot TTJM, Bauer NJC, Jurich J, Kersting O, Nuijts RMMA (2011) Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J Cataract Refract Surg 37:1394–1402CrossRef
8.
Zurück zum Zitat Grohlich M, Miháltz K, Lasta M et al (2017) Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric intraocular lenses. Klin Monbl Augenheilkd 234:796–804CrossRef Grohlich M, Miháltz K, Lasta M et al (2017) Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric intraocular lenses. Klin Monbl Augenheilkd 234:796–804CrossRef
12.
Zurück zum Zitat Roumeliotis G, Hutnik C (2012) A simple reproducible and cost effective axis marking system for toric lens implantation. J Refract Surg 28:12–13CrossRef Roumeliotis G, Hutnik C (2012) A simple reproducible and cost effective axis marking system for toric lens implantation. J Refract Surg 28:12–13CrossRef
13.
Zurück zum Zitat Popp N, Hirnschall N, Maedel S et al (2012) Evaluation of 4 corneal astigmatic marking methods. J Cataract Refract Surg 38:2094–2099CrossRef Popp N, Hirnschall N, Maedel S et al (2012) Evaluation of 4 corneal astigmatic marking methods. J Cataract Refract Surg 38:2094–2099CrossRef
14.
Zurück zum Zitat Igarashi A, Kamiya K, Shimizu K (2013) Clinical evaluation of accuracy of horizontal meridian limbal marking. Optom Vis Sci 90:540–545CrossRef Igarashi A, Kamiya K, Shimizu K (2013) Clinical evaluation of accuracy of horizontal meridian limbal marking. Optom Vis Sci 90:540–545CrossRef
15.
Zurück zum Zitat Lin HY, Fang YT, Chuang YJ, Karlin JN, Chen HY, Lin SY, Lin PJ, Chen M (2017) A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian. Clin Ophthalmol 11:311–315CrossRef Lin HY, Fang YT, Chuang YJ, Karlin JN, Chen HY, Lin SY, Lin PJ, Chen M (2017) A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian. Clin Ophthalmol 11:311–315CrossRef
16.
Zurück zum Zitat Farooqui JH, Koul A, Dutta R, Shroff NM (2016) Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker. Int J Ophthalmol 9:703–706PubMedPubMedCentral Farooqui JH, Koul A, Dutta R, Shroff NM (2016) Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker. Int J Ophthalmol 9:703–706PubMedPubMedCentral
17.
Zurück zum Zitat Hill W, Potvin R (2008) Monte Carlo simulation of expected outcomes with the Acrysof toric intraocular lens. BMC Ophthalmol 8:22CrossRef Hill W, Potvin R (2008) Monte Carlo simulation of expected outcomes with the Acrysof toric intraocular lens. BMC Ophthalmol 8:22CrossRef
18.
Zurück zum Zitat Jordan A, Baum J (1980) Basic tear flow. Does it exist? Ophthalmology 87:920CrossRef Jordan A, Baum J (1980) Basic tear flow. Does it exist? Ophthalmology 87:920CrossRef
19.
Zurück zum Zitat The definition and classification of dry eye disease: report of the definition and classification subcommittee of the international dry eye workshop (2007), vol 5, no 2, pp 75–92 The definition and classification of dry eye disease: report of the definition and classification subcommittee of the international dry eye workshop (2007), vol 5, no 2, pp 75–92
Metadaten
Titel
Effect of corneal marking features on toric intraocular lens alignment
verfasst von
Hasan Aytogan
Publikationsdatum
19.03.2020
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 7/2020
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-020-01333-4

Weitere Artikel der Ausgabe 7/2020

International Ophthalmology 7/2020 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.