Abstract

Objectives

The objectives are To to compare the diagnostic performance of combined digital breast tomosynthesis (DBT) and digital mammography (DM) with that of DM alone, as a function of radiologists’ experience with DBT.

Methods

Ethical committee approval was obtained. Fifty cases (27 cancer, 23 normal), each containing both digital mammography (DM) and digital breast tomosynthesis (DBT) images, were reviewed by 26 radiologists, divided into three groups according to level of experience with DBT (none, workshop experience, and clinical experience). The radiologists’ diagnostic performance using DM was compared with that using DM + DBT, and evaluated by area under receiver-operating characteristic curve (AUC), jackknife free-response receiver-operator characteristics figure of metric (JAFROC FOM), sensitivity, location sensitivity, and specificity.

Results

For all readers combined, performance using DM + DBT was significantly higher than for DM alone by both AUC (0.788 vs 0.681, p < 0.001) and JAFROC FOM (0.745 vs 0.621, p < 0.001). Similar results were obtained for readers with no DBT experience (AUC 0.775 vs 0.682, p = 0.004; JAFROC FOM 0.695 vs 0.603, p = 0.016) and with clinical DBT experience (AUC 0.789 vs 0.681, p = 0.042; and JAFROC FOM 0.764 vs 0.632, p = 0.031).

Conclusions

Addition of DBT to DM significantly improves radiologists’ diagnostic performance whether or not they have prior DBT experience.

Key points

Adding DBT to DM increased the number of detected cancers
DBT + DM led to more accurate localization of breast cancers than DM
Addition of DBT improved radiologistsperformance regardless of prior DBT experience
High-volume radiologists with different DBT experience levels performed similarly on DM + DBT
Literatur
1.
Zurück zum Zitat Parkin DM, Bray F, Ferlay J, Pisani P (2005) Global cancer statistics, 2002. Ca-a Cancer J Clin 55:74–108CrossRef Parkin DM, Bray F, Ferlay J, Pisani P (2005) Global cancer statistics, 2002. Ca-a Cancer J Clin 55:74–108CrossRef
2.
Zurück zum Zitat Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D (2011) Global cancer statistics. CA: A Cancer J Clin 61:69–90 Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D (2011) Global cancer statistics. CA: A Cancer J Clin 61:69–90
4.
Zurück zum Zitat Duffy SW, Tabár L, Chen H-H et al (2002) The impact of organized mammography service screening on breast carcinoma mortality in seven Swedish counties. Cancer 95:458–469PubMedCrossRef Duffy SW, Tabár L, Chen H-H et al (2002) The impact of organized mammography service screening on breast carcinoma mortality in seven Swedish counties. Cancer 95:458–469PubMedCrossRef
5.
Zurück zum Zitat Pisano ED (2006) Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 355:1773–1783 Pisano ED (2006) Diagnostic performance of digital versus film mammography for breast-cancer screening. N Engl J Med 355:1773–1783
6.
Zurück zum Zitat Vernacchia FS, Pena ZG (2009) Digital Mammography: Its Impact on Recall Rates and Cancer Detection Rates in a Small Community-Based Radiology Practice. Am J Roentgenol 193:582–585CrossRef Vernacchia FS, Pena ZG (2009) Digital Mammography: Its Impact on Recall Rates and Cancer Detection Rates in a Small Community-Based Radiology Practice. Am J Roentgenol 193:582–585CrossRef
7.
Zurück zum Zitat David G (2011) Tomosynthesis-Based Imaging of the Breast. Acad Radiol 18:1203–1204CrossRef David G (2011) Tomosynthesis-Based Imaging of the Breast. Acad Radiol 18:1203–1204CrossRef
8.
Zurück zum Zitat Niklason LT, Christian BT, Niklason LE et al (1997) Digital Tomosynthesis in breast imaging. Radiology 205:399–406PubMedCrossRef Niklason LT, Christian BT, Niklason LE et al (1997) Digital Tomosynthesis in breast imaging. Radiology 205:399–406PubMedCrossRef
9.
Zurück zum Zitat Rafferty EA, Park JM, Philpotts LE et al (2013) Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial. Radiology 266:104–13PubMedCrossRef Rafferty EA, Park JM, Philpotts LE et al (2013) Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial. Radiology 266:104–13PubMedCrossRef
10.
Zurück zum Zitat Fornvik D, Zackrisson S, Ljungberg O et al (2010) Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography. Acta Radiol 51:240–247PubMedCrossRef Fornvik D, Zackrisson S, Ljungberg O et al (2010) Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography. Acta Radiol 51:240–247PubMedCrossRef
11.
Zurück zum Zitat Teertstra HJ, Loo CE, van den Bosch M et al (2010) Breast tomosynthesis in clinical practice: initial results. Eur Radiol 20:16–24PubMedCrossRef Teertstra HJ, Loo CE, van den Bosch M et al (2010) Breast tomosynthesis in clinical practice: initial results. Eur Radiol 20:16–24PubMedCrossRef
12.
Zurück zum Zitat Spangler ML, Zuley ML, Sumkin JH et al (2011) Detection and Classification of Calcifications on Digital Breast Tomosynthesis and 2D Digital Mammography: A Comparison. Am J Roentgenol 196:320–324CrossRef Spangler ML, Zuley ML, Sumkin JH et al (2011) Detection and Classification of Calcifications on Digital Breast Tomosynthesis and 2D Digital Mammography: A Comparison. Am J Roentgenol 196:320–324CrossRef
13.
Zurück zum Zitat Gennaro G, Baldan E, Bezzon E, La Grassa M, Pescarini L, di Maggio C (2008) Clinical performance of digital breast tomosynthesis versus full-field digital mammography: Preliminary results. Digit Mammogr Proc 5116:477–482CrossRef Gennaro G, Baldan E, Bezzon E, La Grassa M, Pescarini L, di Maggio C (2008) Clinical performance of digital breast tomosynthesis versus full-field digital mammography: Preliminary results. Digit Mammogr Proc 5116:477–482CrossRef
14.
Zurück zum Zitat Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545–1553PubMedCrossRef Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545–1553PubMedCrossRef
15.
Zurück zum Zitat Svane G, Azavedo E, Lindman K et al (2011) Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography. Acta Radiol 52:134–142PubMedCrossRef Svane G, Azavedo E, Lindman K et al (2011) Clinical experience of photon counting breast tomosynthesis: comparison with traditional mammography. Acta Radiol 52:134–142PubMedCrossRef
16.
Zurück zum Zitat Gur D, Abrams GS, Chough DM et al (2009) Digital Breast Tomosynthesis: Observer Performance Study. Am J Roentgenol 193:586–591CrossRef Gur D, Abrams GS, Chough DM et al (2009) Digital Breast Tomosynthesis: Observer Performance Study. Am J Roentgenol 193:586–591CrossRef
17.
Zurück zum Zitat Smith AP, Rafferty EA, Niklason L (2008) Clinical performance of breast tomosynthesis as a function of radiologist experience level. Digit Mammogr Proc 5116:61–66CrossRef Smith AP, Rafferty EA, Niklason L (2008) Clinical performance of breast tomosynthesis as a function of radiologist experience level. Digit Mammogr Proc 5116:61–66CrossRef
18.
Zurück zum Zitat Svahn TM, Chakraborty DP, Ikeda D et al (2012) Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy. Br J Radiol 85:1074–1082CrossRef Svahn TM, Chakraborty DP, Ikeda D et al (2012) Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy. Br J Radiol 85:1074–1082CrossRef
19.
Zurück zum Zitat Teertstra HJ, Loo CE, Muller SH, Rutgers EJT, Gilhuijs KGA (2008) The sensitivity of breast tomosynthesis compared to digital mammography in the detection of breast cancer in patients referred to an outpatient breast clinic, a prospective analysis. Ejc Suppl 6:98–99CrossRef Teertstra HJ, Loo CE, Muller SH, Rutgers EJT, Gilhuijs KGA (2008) The sensitivity of breast tomosynthesis compared to digital mammography in the detection of breast cancer in patients referred to an outpatient breast clinic, a prospective analysis. Ejc Suppl 6:98–99CrossRef
20.
Zurück zum Zitat Brandt KR, Craig DA, Hoskins TL et al (2013) Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting. AJR Am J Roentgenol 200:291–298PubMedCrossRef Brandt KR, Craig DA, Hoskins TL et al (2013) Can digital breast tomosynthesis replace conventional diagnostic mammography views for screening recalls without calcifications? A comparison study in a simulated clinical setting. AJR Am J Roentgenol 200:291–298PubMedCrossRef
21.
Zurück zum Zitat Waldherr C, Cerny P, Altermatt HJ et al (2013) Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening. AJR Am J Roentgenol 200:226–231PubMedCrossRef Waldherr C, Cerny P, Altermatt HJ et al (2013) Value of one-view breast tomosynthesis versus two-view mammography in diagnostic workup of women with clinical signs and symptoms and in women recalled from screening. AJR Am J Roentgenol 200:226–231PubMedCrossRef
22.
Zurück zum Zitat Ciatto S, Houssami N, Bernardi D et al (2013) Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. Lancet Oncol 14:583–589PubMedCrossRef Ciatto S, Houssami N, Bernardi D et al (2013) Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. Lancet Oncol 14:583–589PubMedCrossRef
23.
Zurück zum Zitat Skaane P, Bandos AI, Gullien R et al (2013) Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program. Radiology 267:47–56PubMedCrossRef Skaane P, Bandos AI, Gullien R et al (2013) Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program. Radiology 267:47–56PubMedCrossRef
24.
Zurück zum Zitat Rose SL, Tidwell AL, Bujnoch LJ, Kushwaha AC, Nordmann AS, Sexton R Jr (2013) Implementation of breast tomosynthesis in a routine screening practice: an observational study. AJR Am J Roentgenol 200:1401–1408PubMedCrossRef Rose SL, Tidwell AL, Bujnoch LJ, Kushwaha AC, Nordmann AS, Sexton R Jr (2013) Implementation of breast tomosynthesis in a routine screening practice: an observational study. AJR Am J Roentgenol 200:1401–1408PubMedCrossRef
25.
Zurück zum Zitat Wallis MG, Moa E, Zanca F, Leifland K, Danielsson M (2012) Two-View and Single-View Tomosynthesis versus Full-Field Digital Mammography: High-Resolution X-Ray Imaging Observer Study. Radiology 262:788–796PubMedCrossRef Wallis MG, Moa E, Zanca F, Leifland K, Danielsson M (2012) Two-View and Single-View Tomosynthesis versus Full-Field Digital Mammography: High-Resolution X-Ray Imaging Observer Study. Radiology 262:788–796PubMedCrossRef
26.
Zurück zum Zitat Svahn T, Andersson I, Chakraborty D et al (2010) The diagnostic accuracy of dual-view digital mammography, single-view breast tomosynthesis and a dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study. Radiat Prot Dosim 139:113–117CrossRef Svahn T, Andersson I, Chakraborty D et al (2010) The diagnostic accuracy of dual-view digital mammography, single-view breast tomosynthesis and a dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study. Radiat Prot Dosim 139:113–117CrossRef
27.
Zurück zum Zitat Good WF, Abrams GS, Catullo VJ et al (2008) Digital breast tomosynthesis: A pilot observer study. Am J Roentgenol 190:865–869CrossRef Good WF, Abrams GS, Catullo VJ et al (2008) Digital breast tomosynthesis: A pilot observer study. Am J Roentgenol 190:865–869CrossRef
28.
Zurück zum Zitat Maxwell AJ, Ridley NT, Rubin G, Wallis MG, Gilbert FJ, Michell MJ The Royal College of Radiologists Breast Group breast imaging classification. Clinical Radiology 64:624-627 Maxwell AJ, Ridley NT, Rubin G, Wallis MG, Gilbert FJ, Michell MJ The Royal College of Radiologists Breast Group breast imaging classification. Clinical Radiology 64:624-627
29.
Zurück zum Zitat American College of Radiology (2003) American College of Radiology Breast Imaging Reporting and Data System (BI-RADS). 4th ed. Reston, Va:American College of Radiology American College of Radiology (2003) American College of Radiology Breast Imaging Reporting and Data System (BI-RADS). 4th ed. Reston, Va:American College of Radiology
30.
Zurück zum Zitat Digital Imaging and Communication in Medicine (DICOM) (2011) Part 14: Grayscale Standard Display Function. National Electrical Manufacturer's Association Digital Imaging and Communication in Medicine (DICOM) (2011) Part 14: Grayscale Standard Display Function. National Electrical Manufacturer's Association
32.
33.
Zurück zum Zitat Skaane P, Young K, Skjennald A (2003) Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading–Oslo I study. Radiology 229:877–884PubMedCrossRef Skaane P, Young K, Skjennald A (2003) Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading–Oslo I study. Radiology 229:877–884PubMedCrossRef
Metadaten
Titel
Effect of radiologists’ experience on breast cancer detection and localization using digital breast tomosynthesis
verfasst von
Maram M. Alakhras
Patrick C. Brennan
Mary Rickard
Roger Bourne
Claudia Mello-Thoms
Publikationsdatum
01.02.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 2/2015
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3409-1

Weitere Artikel der Ausgabe 2/2015

European Radiology 2/2015 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.