Skip to main content
Erschienen in: European Radiology 5/2014

01.05.2014 | Interventional

Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

verfasst von: Takuji Yamagami, Rika Yoshimatsu, Kenji Kajiwara, Masaki Ishikawa, Tomohiro Matsumoto, Hideaki Kakizawa, Naoyuki Toyoda, Terumitsu Hasebe, Kazuo Awai

Erschienen in: European Radiology | Ausgabe 5/2014

Einloggen, um Zugang zu erhalten

Abstract

Objectives

This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance.

Methods

Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples’ sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up.

Results

Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations.

Conclusions

Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy.

Key points

CT-guided needle biopsy is a well-established diagnostic technique.
Touch imprint cytological evaluation on site is helpful in improving quality of CT-guided biopsy.
The rate of diagnosing malignant lymphoma specifically with cytological examination is relatively low.
The rate of specific diagnosis of benign lesion in musculoskeletal regions is low.
Literatur
1.
Zurück zum Zitat Westcott JL (1998) Percutaneous transthoracic needle biopsy. Radiology 169:593–601 Westcott JL (1998) Percutaneous transthoracic needle biopsy. Radiology 169:593–601
2.
Zurück zum Zitat Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: results in 422 patients. Radiology 137:31–35PubMed Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: results in 422 patients. Radiology 137:31–35PubMed
3.
Zurück zum Zitat Laurent F, Latrabe V, Vergier B et al (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needle using a coaxial technique. Cardiovasc Intervent Radiol 23:266–272PubMedCrossRef Laurent F, Latrabe V, Vergier B et al (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needle using a coaxial technique. Cardiovasc Intervent Radiol 23:266–272PubMedCrossRef
4.
Zurück zum Zitat Kattapuram SV, Rosenthal DI (1991) Percutaneous biopsy of skeletal lesions. AJR Am J Roentgenol 157:935–942PubMedCrossRef Kattapuram SV, Rosenthal DI (1991) Percutaneous biopsy of skeletal lesions. AJR Am J Roentgenol 157:935–942PubMedCrossRef
5.
Zurück zum Zitat Sano A, Taniguchi T, Hashimoto T et al (2008) Imaging guided bone biopsy in a clinical general hospital. Jpn Intervent Radiol 23:5–13 Sano A, Taniguchi T, Hashimoto T et al (2008) Imaging guided bone biopsy in a clinical general hospital. Jpn Intervent Radiol 23:5–13
6.
Zurück zum Zitat Yueh N, Halvorsen RJ, Letoumeau JG, Crass JR (1989) Gantry tilt technique for CT-guided biopsy and drainage. J Comput Assist Tomogr 13:182–184PubMedCrossRef Yueh N, Halvorsen RJ, Letoumeau JG, Crass JR (1989) Gantry tilt technique for CT-guided biopsy and drainage. J Comput Assist Tomogr 13:182–184PubMedCrossRef
7.
Zurück zum Zitat Levine ML, Hall FM (1989) Gantry angulation for CT-guided or aspiration. AJR Am J Roentgenol 152:1345–1346PubMedCrossRef Levine ML, Hall FM (1989) Gantry angulation for CT-guided or aspiration. AJR Am J Roentgenol 152:1345–1346PubMedCrossRef
8.
Zurück zum Zitat Daly B, Templeton PA (1999) Real-time CT fluoroscopy: evolution of an interventional tool. Radiology 211:309–315PubMedCrossRef Daly B, Templeton PA (1999) Real-time CT fluoroscopy: evolution of an interventional tool. Radiology 211:309–315PubMedCrossRef
9.
Zurück zum Zitat Gianfelice D, Lepanto L, Perreault P, Chartrand-Lefebvre C, Milette PC (2000) Value of CT fluoroscopy for percutaneous biopsy procedures. J Vasc Interv Radiol 11:879–884PubMedCrossRef Gianfelice D, Lepanto L, Perreault P, Chartrand-Lefebvre C, Milette PC (2000) Value of CT fluoroscopy for percutaneous biopsy procedures. J Vasc Interv Radiol 11:879–884PubMedCrossRef
10.
Zurück zum Zitat Hayashi N, Sakai T, Kitagawa M et al (1998) CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis. AJR Am J Roentgenol 170:329–331PubMedCrossRef Hayashi N, Sakai T, Kitagawa M et al (1998) CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis. AJR Am J Roentgenol 170:329–331PubMedCrossRef
11.
Zurück zum Zitat Sakai T, Hayashi N, Kimoto T et al (1994) CT-guided biopsy of the chest: usefulness of fine-needle core biopsy combined with frozen-section pathologic diagnosis. Radiology 190:243–246PubMed Sakai T, Hayashi N, Kimoto T et al (1994) CT-guided biopsy of the chest: usefulness of fine-needle core biopsy combined with frozen-section pathologic diagnosis. Radiology 190:243–246PubMed
12.
Zurück zum Zitat Yamagami T, Iida S, Kato T, Tanaka O, Nishimura T (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules? AJR Am J Roentgenol 180:811–815PubMedCrossRef Yamagami T, Iida S, Kato T, Tanaka O, Nishimura T (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules? AJR Am J Roentgenol 180:811–815PubMedCrossRef
13.
Zurück zum Zitat Chang YC, Yu CJ, Lee WJ, Kuo SH, Hsiao CH, Jan IS, Hu FC, Liu HM, Chan WK, Yang PC (2008) Imprint cytology improves accuracy of computed tomography-guided percutaneous transthoracic needle biopsy. Eur Respir J 31:54–61PubMedCrossRef Chang YC, Yu CJ, Lee WJ, Kuo SH, Hsiao CH, Jan IS, Hu FC, Liu HM, Chan WK, Yang PC (2008) Imprint cytology improves accuracy of computed tomography-guided percutaneous transthoracic needle biopsy. Eur Respir J 31:54–61PubMedCrossRef
14.
Zurück zum Zitat Katada K, Kato R, Anno H et al (1996) Guidance with real-time CT fluoroscopy: early clinical experience. Radiology 200:851–856PubMed Katada K, Kato R, Anno H et al (1996) Guidance with real-time CT fluoroscopy: early clinical experience. Radiology 200:851–856PubMed
15.
Zurück zum Zitat Greene R, Szyfelbein WM, Isler RJ, Stark P, Jantsch H (1985) Supplementary tissue-core histology from fine-needle transthoracic aspiration biopsy. AJR Am J Roentgenol 144:787–792PubMedCrossRef Greene R, Szyfelbein WM, Isler RJ, Stark P, Jantsch H (1985) Supplementary tissue-core histology from fine-needle transthoracic aspiration biopsy. AJR Am J Roentgenol 144:787–792PubMedCrossRef
16.
Zurück zum Zitat Haramati LB (1995) CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol 165:53–55PubMedCrossRef Haramati LB (1995) CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol 165:53–55PubMedCrossRef
17.
Zurück zum Zitat Lucidarme O, Howarth N, Finet JF et al (1998) Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18 gauge, coaxial cutting needle. Radiology 207:759–765PubMed Lucidarme O, Howarth N, Finet JF et al (1998) Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18 gauge, coaxial cutting needle. Radiology 207:759–765PubMed
18.
Zurück zum Zitat Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20 gauge automated cutting needle: results in 122 patients. Radiology 198:715–720PubMed Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20 gauge automated cutting needle: results in 122 patients. Radiology 198:715–720PubMed
19.
Zurück zum Zitat Tsukada H, Satou T, Iwashima A et al (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175:239–243PubMedCrossRef Tsukada H, Satou T, Iwashima A et al (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 175:239–243PubMedCrossRef
20.
Zurück zum Zitat Boiselle PM, Shepard JO, Mark EJ et al (1997) Routine addition of an automated biopsy device to fine needle biopsy of the lung: a prospective assessment. AJR Am J Roentgenol 169:661–666PubMedCrossRef Boiselle PM, Shepard JO, Mark EJ et al (1997) Routine addition of an automated biopsy device to fine needle biopsy of the lung: a prospective assessment. AJR Am J Roentgenol 169:661–666PubMedCrossRef
21.
Zurück zum Zitat Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T (1996) CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 51:503–506PubMedCrossRef Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T (1996) CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 51:503–506PubMedCrossRef
22.
Zurück zum Zitat van Sonnenberg E, Casola G, Ho M et al (1988) Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 167:457–461 van Sonnenberg E, Casola G, Ho M et al (1988) Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 167:457–461
23.
Zurück zum Zitat Kazerooni EA, Lim FT, Mikhail A et al (1996) Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 198:371–375PubMed Kazerooni EA, Lim FT, Mikhail A et al (1996) Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 198:371–375PubMed
24.
Zurück zum Zitat Yamagami T, Iida S, Kato T, Tanaka O, Toda S, Kato D et al (2003) Usefulness of new automated cutting needle for tissue-core biopsy of lung nodules under CT fluoroscopic guidance. Chest 124:147–154PubMedCrossRef Yamagami T, Iida S, Kato T, Tanaka O, Toda S, Kato D et al (2003) Usefulness of new automated cutting needle for tissue-core biopsy of lung nodules under CT fluoroscopic guidance. Chest 124:147–154PubMedCrossRef
25.
Zurück zum Zitat Haramati LB (1995) CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol 165:53–55PubMedCrossRef Haramati LB (1995) CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol 165:53–55PubMedCrossRef
26.
Zurück zum Zitat Kellogg JA, Seiple JW, Klinedinst JL, Stroll E (1996) Diff-Quik stain as a simplified alternative to Papanicolaou stain for determination of quality of endocervical specimens submitted for PCR detection of Chlamydia trachomatis. J Clin Microbiol 34:2590–2592PubMedCentralPubMed Kellogg JA, Seiple JW, Klinedinst JL, Stroll E (1996) Diff-Quik stain as a simplified alternative to Papanicolaou stain for determination of quality of endocervical specimens submitted for PCR detection of Chlamydia trachomatis. J Clin Microbiol 34:2590–2592PubMedCentralPubMed
27.
Zurück zum Zitat Prosch H, Hoffmann E, Bernhardt K, Schalleschak J, Schober E, Rowhani M, Weber M, Mostbeck G (2011) Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: a feasibility study. Eur Radiol 21:1922–1927PubMedCrossRef Prosch H, Hoffmann E, Bernhardt K, Schalleschak J, Schober E, Rowhani M, Weber M, Mostbeck G (2011) Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: a feasibility study. Eur Radiol 21:1922–1927PubMedCrossRef
Metadaten
Titel
Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy
verfasst von
Takuji Yamagami
Rika Yoshimatsu
Kenji Kajiwara
Masaki Ishikawa
Tomohiro Matsumoto
Hideaki Kakizawa
Naoyuki Toyoda
Terumitsu Hasebe
Kazuo Awai
Publikationsdatum
01.05.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 5/2014
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3104-2

Weitere Artikel der Ausgabe 5/2014

European Radiology 5/2014 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.