Background

The aim of this study is to examine operative flow disruption that occurs inside the surgical field, (internal operative flow disruption (OFD)), during urological laparoscopies, and to relate those events to external ergonomics environment in terms of monitor location, level of instruments’ handles, and location of surgical team members. According to the our best knowledge, this is the first study of its kind.

Methods

A combination of real and video-aided observational study was conducted in the operating rooms at hospitals in Australia and China. Brain storming sessions were first conducted to identify the main internal OFD events, and the observable reasons, potential external, and latent ergonomic factors were listed. A prospective observational study was then conducted. The observer’s records and the related video records of internal surgical fields were analysed. Procedures were categorised into groups based on similarity in ergonomics environment.

Results

The mapping process revealed 39 types of internal OFD events resulted from six reasons. A total of 24 procedures were selected and arranged into two groups, each with twelve procedures. Group A was carried out under satisfactory ergonomics environment, while Group B was conducted under unsatisfactory ergonomics environment. A total of 1178 OFD events were detected delaying the total observed operative times (2966 min) by 220 min (7.43%). Average OFD/h in group A was less than 15, while in group B about 29 OFD/h.

Conclusion

There are two main latent ergonomics factors affecting the surgeon’s performance; non-physiological posture and long-period static posture. The delays and number of internal OFD were nearly doubled where procedures were conducted under unsatisfactory external ergonomics environment. Some events such as stopping operation and irrelevant conversations during long procedures may have a positive influence on the surgeon’s performance.
Literatur
1.
Zurück zum Zitat Undre S, Arora S, Sevdalis N (2009) Surgical performance, human error and patient safety in urological surgery. Br J Med Surg Urol 2:2–10CrossRef Undre S, Arora S, Sevdalis N (2009) Surgical performance, human error and patient safety in urological surgery. Br J Med Surg Urol 2:2–10CrossRef
2.
Zurück zum Zitat Sevdalis N, Forrest D, Undre S, Darzi A, Vincent C (2008) Annoyances, disruptions, and interruptions in surgery: the disruptions in surgery index (DiSI). World J Surg 32:1643–1650CrossRefPubMed Sevdalis N, Forrest D, Undre S, Darzi A, Vincent C (2008) Annoyances, disruptions, and interruptions in surgery: the disruptions in surgery index (DiSI). World J Surg 32:1643–1650CrossRefPubMed
3.
Zurück zum Zitat Wiegmann DA, ElBardissi AW, Dearani JA, Daly RC, Sundt TM (2007) Disruptions in surgical flow and their relationship to surgical errors: an exploratory investigation. Surgery 142:658–665CrossRefPubMed Wiegmann DA, ElBardissi AW, Dearani JA, Daly RC, Sundt TM (2007) Disruptions in surgical flow and their relationship to surgical errors: an exploratory investigation. Surgery 142:658–665CrossRefPubMed
4.
Zurück zum Zitat Al-Hakim L (2008) Surgical disruption: information quality perspective. Int J Inf Qual 2:192–204CrossRef Al-Hakim L (2008) Surgical disruption: information quality perspective. Int J Inf Qual 2:192–204CrossRef
5.
Zurück zum Zitat Etchells E, O’Neill C, Bernstein M (2003) Patient safety in surgery: error detection and prevention. World J Surg 27:936–941CrossRefPubMed Etchells E, O’Neill C, Bernstein M (2003) Patient safety in surgery: error detection and prevention. World J Surg 27:936–941CrossRefPubMed
6.
Zurück zum Zitat Kohn LT, Corrigan JM, Donaldson MS (2000) To err is human: building a safer health system. A report of the Committee on Quality of Health Care in America, Institute of Medicine. National Academy Press, Washington, DC Kohn LT, Corrigan JM, Donaldson MS (2000) To err is human: building a safer health system. A report of the Committee on Quality of Health Care in America, Institute of Medicine. National Academy Press, Washington, DC
7.
Zurück zum Zitat Fumo MJ, Hemal AK, Menon M (2007) Robotic assisted laparoscopic radical prostatectomy. In: Naito S, Hirao Y, Terachi T (eds) Endourological management of urogenital carcinoma. Springer, Tokyo, pp 175–190 Fumo MJ, Hemal AK, Menon M (2007) Robotic assisted laparoscopic radical prostatectomy. In: Naito S, Hirao Y, Terachi T (eds) Endourological management of urogenital carcinoma. Springer, Tokyo, pp 175–190
8.
Zurück zum Zitat Gjeraa K, Spanager L, Konge L, Petersen RH (2016) Non-technical skills in minimally invasive surgery teams: a systematic review. Surgical Endoscopy, Online version Gjeraa K, Spanager L, Konge L, Petersen RH (2016) Non-technical skills in minimally invasive surgery teams: a systematic review. Surgical Endoscopy, Online version
9.
Zurück zum Zitat Zeng B, Martinec DV, Cassera MA, Swanström LL (2008) A qantitative study of disruption in the operating room during laparoscopic antireflux surgeru. Surg Endosc 22:2171–2177CrossRef Zeng B, Martinec DV, Cassera MA, Swanström LL (2008) A qantitative study of disruption in the operating room during laparoscopic antireflux surgeru. Surg Endosc 22:2171–2177CrossRef
10.
Zurück zum Zitat Arora S, Hull L, Sevdalis N, Tierney T, Nestel D, Woloshynowych M, Darzi A, Kneebone R (2010) Factors compromising safety in surgery: stressful events in the operating room. Am J Surg 199:60–65CrossRefPubMed Arora S, Hull L, Sevdalis N, Tierney T, Nestel D, Woloshynowych M, Darzi A, Kneebone R (2010) Factors compromising safety in surgery: stressful events in the operating room. Am J Surg 199:60–65CrossRefPubMed
11.
Zurück zum Zitat Arora S, Sevdalis E (2011) A systemic analysis of disruption in operating room: reply. World J Surg 35:931–932CrossRef Arora S, Sevdalis E (2011) A systemic analysis of disruption in operating room: reply. World J Surg 35:931–932CrossRef
12.
Zurück zum Zitat Mishra A, Catchpole KR, Dale T, McCulloch P (2008) The influence of non-technical performance on technical outcome in laparoscopic cholecystectomy. Surg Endosc 22:68–73CrossRefPubMed Mishra A, Catchpole KR, Dale T, McCulloch P (2008) The influence of non-technical performance on technical outcome in laparoscopic cholecystectomy. Surg Endosc 22:68–73CrossRefPubMed
13.
Zurück zum Zitat Joice P, Hanna GB, Cuschieri A (1998) Error enacted during endoscopic surgery: a human reliability analysis. Appl Ergon 29:409–414CrossRefPubMed Joice P, Hanna GB, Cuschieri A (1998) Error enacted during endoscopic surgery: a human reliability analysis. Appl Ergon 29:409–414CrossRefPubMed
14.
Zurück zum Zitat Al-Hakim L (2011) The impact of preventable disruption on the operative time for minimally invasive surgery. Surg Endosc 25:3385–3392CrossRefPubMed Al-Hakim L (2011) The impact of preventable disruption on the operative time for minimally invasive surgery. Surg Endosc 25:3385–3392CrossRefPubMed
15.
Zurück zum Zitat Vereczkei A, Feussner H, Negele T, Fritzsche F, Seitz T, Bubb H, Horvath OP (2004) Ergonomic assessment of the static stress confronted by surgeons during laparoscopic cholechstectomy. Surg Endosc 18:1118–1122CrossRefPubMed Vereczkei A, Feussner H, Negele T, Fritzsche F, Seitz T, Bubb H, Horvath OP (2004) Ergonomic assessment of the static stress confronted by surgeons during laparoscopic cholechstectomy. Surg Endosc 18:1118–1122CrossRefPubMed
16.
Zurück zum Zitat Jaschinski W, Heuer H, Kylian H (1998) Preferred position of visual displays relative to the eyes: a field study of visual strain and individual differences. Ergonomics 41:1034–1049CrossRefPubMed Jaschinski W, Heuer H, Kylian H (1998) Preferred position of visual displays relative to the eyes: a field study of visual strain and individual differences. Ergonomics 41:1034–1049CrossRefPubMed
17.
Zurück zum Zitat van Det MJ, Meijerink WJ, Hoff C, Totte ER, Pierie JP (2009) Optimal ergonomics for laparoscopic surgery in minimally inasive surgery suites: a review and guidelines. Surg Endosc 23:1279–1285CrossRefPubMed van Det MJ, Meijerink WJ, Hoff C, Totte ER, Pierie JP (2009) Optimal ergonomics for laparoscopic surgery in minimally inasive surgery suites: a review and guidelines. Surg Endosc 23:1279–1285CrossRefPubMed
19.
Zurück zum Zitat Wong H, Forrest D, Healey A, Shirafkan H, Hanna G, Vincent C, Sevdalis N (2011) Information needs in operating room teams: what is right, what is wrong and wat is needed? Surg Endosc 25:1913–1920CrossRefPubMed Wong H, Forrest D, Healey A, Shirafkan H, Hanna G, Vincent C, Sevdalis N (2011) Information needs in operating room teams: what is right, what is wrong and wat is needed? Surg Endosc 25:1913–1920CrossRefPubMed
20.
Zurück zum Zitat Al-Hakim L, Gong XY (2011) On the day of surgery: how long does preventable desruption prolong the patient journey? Int J Health Care Qual Assur Appear 25(4):322–342CrossRef Al-Hakim L, Gong XY (2011) On the day of surgery: how long does preventable desruption prolong the patient journey? Int J Health Care Qual Assur Appear 25(4):322–342CrossRef
21.
Zurück zum Zitat Sevdalis N, Healey AN, Vincent CA (2007) Distracting communications in the operating theatre. J Eval Clin Pract 13:390–394CrossRefPubMed Sevdalis N, Healey AN, Vincent CA (2007) Distracting communications in the operating theatre. J Eval Clin Pract 13:390–394CrossRefPubMed
22.
Zurück zum Zitat Al-Hakim L, Arora S, Sevdalis N (2016) Impact of disruptions on anaesthetic workflow during anaesthesia induction and patient positioning. Eur J Anaesthesiol 33:1–7CrossRef Al-Hakim L, Arora S, Sevdalis N (2016) Impact of disruptions on anaesthetic workflow during anaesthesia induction and patient positioning. Eur J Anaesthesiol 33:1–7CrossRef
23.
Zurück zum Zitat Zheng B, Swanström LL, MacKenzie CL (2007) A laboratory study on anticipatory movement in laparoscopic surgery: a behavioral indicator for team collaboration. Surg Endosc 21:935–940CrossRefPubMed Zheng B, Swanström LL, MacKenzie CL (2007) A laboratory study on anticipatory movement in laparoscopic surgery: a behavioral indicator for team collaboration. Surg Endosc 21:935–940CrossRefPubMed
24.
Zurück zum Zitat Moorthy K, Munz Y, Adams S, Pandey V, Darzi A (2005) A human factors analysis of technical and team skills among surgical trainees during procedural simulations in a simulated operating theatre. Ann Surg 242:631–639CrossRefPubMedPubMedCentral Moorthy K, Munz Y, Adams S, Pandey V, Darzi A (2005) A human factors analysis of technical and team skills among surgical trainees during procedural simulations in a simulated operating theatre. Ann Surg 242:631–639CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat He W, Ni S, Chen G, Jiang X, Zheng B (2013) The composition of surgical teams in the operating room and its impact on surgical team performance in China. Surg Endos 28:1473–1478CrossRef He W, Ni S, Chen G, Jiang X, Zheng B (2013) The composition of surgical teams in the operating room and its impact on surgical team performance in China. Surg Endos 28:1473–1478CrossRef
26.
Zurück zum Zitat Shorrock S, Kirwan B (2002) Development and application of a human error identification tool for air traffic control. Appl Ergon 33:319–336CrossRefPubMed Shorrock S, Kirwan B (2002) Development and application of a human error identification tool for air traffic control. Appl Ergon 33:319–336CrossRefPubMed
27.
Zurück zum Zitat Catchpole KR, Anthony EB, Giddings MD, Wilkinson M, Hirst G, Dale T, Marc R, de Leval MD (2007) Improving patient safety by identifying latent failures in successful operations. Surgery 142:102–110CrossRefPubMed Catchpole KR, Anthony EB, Giddings MD, Wilkinson M, Hirst G, Dale T, Marc R, de Leval MD (2007) Improving patient safety by identifying latent failures in successful operations. Surgery 142:102–110CrossRefPubMed
28.
Zurück zum Zitat Catchpole KR, Giddings AE, de Leval MR, Peek GJ, Godden PJ, Utley M, Gallivan S, Hirst G, Dale T (2006) Identification of systems failures in successful paediatric cardiac surgery. Ergonomics 49:567–588CrossRefPubMed Catchpole KR, Giddings AE, de Leval MR, Peek GJ, Godden PJ, Utley M, Gallivan S, Hirst G, Dale T (2006) Identification of systems failures in successful paediatric cardiac surgery. Ergonomics 49:567–588CrossRefPubMed
29.
Zurück zum Zitat Al-Hakim L, Maiping T, Watanachote MD, Sengupta S (2015) Human error identification tool for laparoscopic surgery: motion economy perspective. Appl Ergon 50:113–125CrossRefPubMed Al-Hakim L, Maiping T, Watanachote MD, Sengupta S (2015) Human error identification tool for laparoscopic surgery: motion economy perspective. Appl Ergon 50:113–125CrossRefPubMed
30.
Zurück zum Zitat Adams R, Warner P, Hubbard B, Goulding T (2004) Decreasing turnaround time between general surgery cases: a six sigma initiative. JONA 34:140–148CrossRef Adams R, Warner P, Hubbard B, Goulding T (2004) Decreasing turnaround time between general surgery cases: a six sigma initiative. JONA 34:140–148CrossRef
31.
Zurück zum Zitat van Veelen MA, Kazemier G, Koopman J, Goossens RH, Meijer DW (2002) Assessment of the ergonomically optimal operating surface height for laparoscopic surgery. J Laparoendosc Adv Surg Tech 12:47–52CrossRef van Veelen MA, Kazemier G, Koopman J, Goossens RH, Meijer DW (2002) Assessment of the ergonomically optimal operating surface height for laparoscopic surgery. J Laparoendosc Adv Surg Tech 12:47–52CrossRef
32.
Zurück zum Zitat Manasnayakorn S, Cuschieri A, Hanna GB (2009) Ergonomic assessment of optimum operating table height for hand-assisted laparoscopic surgery. Surg Endosc 23:783–789CrossRefPubMed Manasnayakorn S, Cuschieri A, Hanna GB (2009) Ergonomic assessment of optimum operating table height for hand-assisted laparoscopic surgery. Surg Endosc 23:783–789CrossRefPubMed
33.
Zurück zum Zitat Jaschinski W, Heuer H, Kylian H (1999) A procedure to determine the individually comfortable position of visual displays relative to the eyes. Ergonomics 42:535–549CrossRefPubMed Jaschinski W, Heuer H, Kylian H (1999) A procedure to determine the individually comfortable position of visual displays relative to the eyes. Ergonomics 42:535–549CrossRefPubMed
34.
Zurück zum Zitat van den Hombergh P, Künzi B, Elwyn G, Doremalen J, Akkermans R, Grol R, Wensing M (2009) High workload and job stress are associated with lower practice performance in general practice: an observational study in 239 general practices in the Netherlands. BMC Health Serv Res 9:1–8CrossRef van den Hombergh P, Künzi B, Elwyn G, Doremalen J, Akkermans R, Grol R, Wensing M (2009) High workload and job stress are associated with lower practice performance in general practice: an observational study in 239 general practices in the Netherlands. BMC Health Serv Res 9:1–8CrossRef
35.
Zurück zum Zitat Weigl M, Antoniadis S, Chiapponi C, Bruns C, Sevdalis N (2014) The impact of intra-operative interruptions on surgeons’ perceived workload: an observational study in elective general and orthopedic surgery. World J Surg 29:145–153 Weigl M, Antoniadis S, Chiapponi C, Bruns C, Sevdalis N (2014) The impact of intra-operative interruptions on surgeons’ perceived workload: an observational study in elective general and orthopedic surgery. World J Surg 29:145–153
36.
Zurück zum Zitat Kao L, Thomas E (2008) Navigating towards improved surgical safety using aviation-based strategies. J Surg Res 145:327–335CrossRefPubMed Kao L, Thomas E (2008) Navigating towards improved surgical safety using aviation-based strategies. J Surg Res 145:327–335CrossRefPubMed
37.
Zurück zum Zitat Al-Hakim L, Sevdalis N, Arora S (2012) On surgical disruption rating, expected operation time or actual wasted time - some comments on Gillepsie et al (2012). BMJ Qual Saf 21:532CrossRefPubMed Al-Hakim L, Sevdalis N, Arora S (2012) On surgical disruption rating, expected operation time or actual wasted time - some comments on Gillepsie et al (2012). BMJ Qual Saf 21:532CrossRefPubMed
Metadaten
Titel
Ergonomics perspective for identifying and reducing internal operative flow disruption for laparoscopic urological surgery
verfasst von
Latif Al-Hakim
Jiaquan Xiao
Shomik Sengupta
Publikationsdatum
28.04.2017
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 12/2017
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-017-5568-z

Weitere Artikel der Ausgabe 12/2017

Surgical Endoscopy 12/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.