Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 6/2014

01.12.2014 | Original Research

Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch

verfasst von: Geoffrey G. Lockwood, Nick L. S. Fung, J. Gareth Jones

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 6/2014

Einloggen, um Zugang zu erhalten

Abstract

We describe a three-compartment model (shunt and two perfused compartments) to analyse the relationship between inspired oxygen (FIO2) and arterial oxygen saturation (SaO2) in terms of pulmonary shunt and ventilation-perfusion ratio (VA/Q). The program was tested using 24 exact datasets, each with six pairs of FIO2 and SaO2 data points with known VA/Q and shunt, generated by a complex calculator of gas exchange. Additional datasets were created by adding noise and rounding the exact sets, and by reducing the number of data points per dataset. The importance of the oxyhaemoglobin dissociation curve and the arterio-venous difference in oxygen content (avDO2) were also tested. Analysis using the three compartment model was more accurate than the two compartment model and less affected by data degradation. The absolute error in shunt estimation was never more than 2.2 % for the exact and rounded datasets, but the error in VA/Q estimation was −29 to 19 % of the true value (10th–90th centiles). The characteristics of the well-ventilated compartment were not determined accurately. At extremes of cardiac output, an assumed value of avDO2 resulted in significant errors. It is probably advantageous to correct for foetal haemoglobin in neonatal datasets. Analysis of FIO2 versus SaO2 datasets using a three compartment model provides accurate estimates of shunt and VA/Q when arterio-venous difference in oxygen content is known. The estimates may have value as objective measures of gas exchange, and as a visual guide for oxygen therapy.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Karbing DS, Kjærgaard S, Smith BW, Espersen K, Allerød C, Andreassen S, Rees SE. Variation in the PaO2/FIO2 ratio with FIO2: mathematical and experimental description, and clinical relevance. Crit Care. 2007;11:R118.CrossRefPubMedPubMedCentral Karbing DS, Kjærgaard S, Smith BW, Espersen K, Allerød C, Andreassen S, Rees SE. Variation in the PaO2/FIO2 ratio with FIO2: mathematical and experimental description, and clinical relevance. Crit Care. 2007;11:R118.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Sapsford DJ, Jones JG. The PIO2 vs SpO2 diagram: a non-invasive measurement of pulmonary oxygen exchange. Eur J Anaesth. 1995;12:375–86. Sapsford DJ, Jones JG. The PIO2 vs SpO2 diagram: a non-invasive measurement of pulmonary oxygen exchange. Eur J Anaesth. 1995;12:375–86.
3.
Zurück zum Zitat Vidal Melo MF, Loeppky JA, Caprihan A, Luft UC. Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange. Comp Biomed Res. 1993;26:103–20.CrossRef Vidal Melo MF, Loeppky JA, Caprihan A, Luft UC. Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange. Comp Biomed Res. 1993;26:103–20.CrossRef
4.
Zurück zum Zitat Karbing DS, Kjærgaard S, Andreassen S, Espersen K, Rees SE. Minimal model quantification of pulmonary gas exchange in intensive care patients. Med Eng Phys. 2011;33:240–8.CrossRefPubMed Karbing DS, Kjærgaard S, Andreassen S, Espersen K, Rees SE. Minimal model quantification of pulmonary gas exchange in intensive care patients. Med Eng Phys. 2011;33:240–8.CrossRefPubMed
5.
Zurück zum Zitat Olszowka AJ, Wagner PD. Numerical analysis of gas exchange. In: West JB, editor. Pulmonary gas exchange. New York: Academic Press; 1980. p. 263–306. Olszowka AJ, Wagner PD. Numerical analysis of gas exchange. In: West JB, editor. Pulmonary gas exchange. New York: Academic Press; 1980. p. 263–306.
6.
Zurück zum Zitat Severinghaus JW. Simple, accurate equations for human blood O2 dissociation computations. J Appl Physiol. 1979;46:599–602.PubMed Severinghaus JW. Simple, accurate equations for human blood O2 dissociation computations. J Appl Physiol. 1979;46:599–602.PubMed
7.
Zurück zum Zitat Cormack RS, Lockwood GG. Exact model for the oxyhaemoglobin dissociation curve. Br J Anaesth. 2011;106:430P. Cormack RS, Lockwood GG. Exact model for the oxyhaemoglobin dissociation curve. Br J Anaesth. 2011;106:430P.
8.
Zurück zum Zitat Kasinger W, Huch R, Huch A. In vivo oxygen dissociation curve for whole fetal blood: fitting the Adair equation and blood gas nomogram. Scand J Clin Lab Invest. 1981;41:701–7.CrossRefPubMed Kasinger W, Huch R, Huch A. In vivo oxygen dissociation curve for whole fetal blood: fitting the Adair equation and blood gas nomogram. Scand J Clin Lab Invest. 1981;41:701–7.CrossRefPubMed
9.
Zurück zum Zitat Covelli HD, Nessan VJ, Tuttle WK. Oxygen derived variables in acute respiratory failure. Crit Care Med. 1983;11:646–9.CrossRefPubMed Covelli HD, Nessan VJ, Tuttle WK. Oxygen derived variables in acute respiratory failure. Crit Care Med. 1983;11:646–9.CrossRefPubMed
10.
Zurück zum Zitat Boxenbaum HG, Riegeiman S, Elashoff RM. Statistical estimations in pharmacokinetics. J Pharmacokinet Biopharm. 1974;2:123–48.CrossRefPubMed Boxenbaum HG, Riegeiman S, Elashoff RM. Statistical estimations in pharmacokinetics. J Pharmacokinet Biopharm. 1974;2:123–48.CrossRefPubMed
11.
Zurück zum Zitat Peyton PJ, Poustie SJ, Robinson GJB, Penny DJ, Thompson B. Non-invasive measurement of intrapulmonary shunt during inert gas rebreathing. Physiol Meas. 2005;26:309–16.CrossRefPubMed Peyton PJ, Poustie SJ, Robinson GJB, Penny DJ, Thompson B. Non-invasive measurement of intrapulmonary shunt during inert gas rebreathing. Physiol Meas. 2005;26:309–16.CrossRefPubMed
12.
Zurück zum Zitat Steinhart CM, Burch KD, Brudno S, Parker DH. Noninvasive determination of effective (non shunted) pulmonary blood flow in normal and injured lungs. Crit Care Med. 1989;17:349–53.CrossRefPubMed Steinhart CM, Burch KD, Brudno S, Parker DH. Noninvasive determination of effective (non shunted) pulmonary blood flow in normal and injured lungs. Crit Care Med. 1989;17:349–53.CrossRefPubMed
13.
Zurück zum Zitat Reutershan J, Ressel M, Wagner T, Schröder T, Dietz K, Fretschner R. Non-invasive determination of effective pulmonary blood flow: evaluation of a simplified rebreathing method. J Med Eng. 2003;27:194–9. Reutershan J, Ressel M, Wagner T, Schröder T, Dietz K, Fretschner R. Non-invasive determination of effective pulmonary blood flow: evaluation of a simplified rebreathing method. J Med Eng. 2003;27:194–9.
14.
Zurück zum Zitat Hope DA, Jenkins BJ, Willis N, Maddock H, Mapleson WW. Non-invasive estimation of venous admixture: validation of a new formula. Brit J Anaesth. 1995;74:538–43.CrossRefPubMed Hope DA, Jenkins BJ, Willis N, Maddock H, Mapleson WW. Non-invasive estimation of venous admixture: validation of a new formula. Brit J Anaesth. 1995;74:538–43.CrossRefPubMed
15.
Zurück zum Zitat de Gray L, Rush EM, Jones JG. A non-invasive method for evaluating the effect of thoracotomy on shunt and ventilation perfusion inequality. Anaesthesia. 1997;52:630–5.CrossRefPubMed de Gray L, Rush EM, Jones JG. A non-invasive method for evaluating the effect of thoracotomy on shunt and ventilation perfusion inequality. Anaesthesia. 1997;52:630–5.CrossRefPubMed
16.
Zurück zum Zitat Quine D, Wong CM, Boyle EM, Jones JG, Stenson BJ. Non-invasive measurement of reduced ventilation perfusion ratio and shunt in infants with bronchopulmonary dysplasia: a physiological definition of the disease. Arch Dis Child Fetal Neonatal Ed. 2006;9:F409–14.CrossRef Quine D, Wong CM, Boyle EM, Jones JG, Stenson BJ. Non-invasive measurement of reduced ventilation perfusion ratio and shunt in infants with bronchopulmonary dysplasia: a physiological definition of the disease. Arch Dis Child Fetal Neonatal Ed. 2006;9:F409–14.CrossRef
17.
Zurück zum Zitat Kjærgaard S, Rees S, Malczynski J, Nielsen JA, Thorgaard P, Toft E, Andreassen S. Non-invasive estimation of shunt and ventilation-perfusion mismatch. Int Care Med. 2003;29:727–34.CrossRef Kjærgaard S, Rees S, Malczynski J, Nielsen JA, Thorgaard P, Toft E, Andreassen S. Non-invasive estimation of shunt and ventilation-perfusion mismatch. Int Care Med. 2003;29:727–34.CrossRef
18.
Zurück zum Zitat Rees SE, Kjærgaard S, Thorgaard P, Malczynski J, Toft E, Andreassen S. The automatic lung parameter estimator (ALPE) system: non-invasive estimation of pulmonary gas exchange parameters in 10–15 minutes. J Clin Monit Comput. 2002;17:43–52.CrossRefPubMed Rees SE, Kjærgaard S, Thorgaard P, Malczynski J, Toft E, Andreassen S. The automatic lung parameter estimator (ALPE) system: non-invasive estimation of pulmonary gas exchange parameters in 10–15 minutes. J Clin Monit Comput. 2002;17:43–52.CrossRefPubMed
19.
Zurück zum Zitat Thomsen LP, Karbing DS, Smith BW, Murley D, Weinreich UM, Kjærgaard S, Toft E, Thorgaard P, Andreassen S, Rees SE. Clinical refinement of the automatic lung parameter estimator (ALPE). J Clin Monit Comput. 2013;27:341–50.CrossRefPubMed Thomsen LP, Karbing DS, Smith BW, Murley D, Weinreich UM, Kjærgaard S, Toft E, Thorgaard P, Andreassen S, Rees SE. Clinical refinement of the automatic lung parameter estimator (ALPE). J Clin Monit Comput. 2013;27:341–50.CrossRefPubMed
20.
Zurück zum Zitat Rees SE, Kjærgaard S, Andreassen S, Hedenstierna G. Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid. J Appl Physiol. 2006;101:826–32.CrossRefPubMed Rees SE, Kjærgaard S, Andreassen S, Hedenstierna G. Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid. J Appl Physiol. 2006;101:826–32.CrossRefPubMed
21.
Zurück zum Zitat Tahvanainen J, Meretoja O, Nikki P. Can central venous blood replace mixed venous blood samples? Crit Care Med. 1982;10:758–61.CrossRefPubMed Tahvanainen J, Meretoja O, Nikki P. Can central venous blood replace mixed venous blood samples? Crit Care Med. 1982;10:758–61.CrossRefPubMed
22.
Zurück zum Zitat Ladakis C, Myrianthefs P, Karabinis A, Karatzas G, Dosios T, Fildissis G, Gogas J, Baltopoulos G. Central venous and mixed venous oxygen saturation in critically ill patients. Respiration. 2001;68:279–85.CrossRefPubMed Ladakis C, Myrianthefs P, Karabinis A, Karatzas G, Dosios T, Fildissis G, Gogas J, Baltopoulos G. Central venous and mixed venous oxygen saturation in critically ill patients. Respiration. 2001;68:279–85.CrossRefPubMed
23.
Zurück zum Zitat Edwards JD, Mayall RM. Importance of the sampling site for measurement of mixed venous oxgen saturation in shock. Crit Care Med. 1998;26:1356–60.CrossRefPubMed Edwards JD, Mayall RM. Importance of the sampling site for measurement of mixed venous oxgen saturation in shock. Crit Care Med. 1998;26:1356–60.CrossRefPubMed
24.
Zurück zum Zitat Chawla LS, Hasan Z, Gutierrez G, Katz NM, Seneff MG, Shah M. Lack of equivalence between central and mixed venous oxygen saturation. Chest. 2004;126:1891–6.CrossRefPubMed Chawla LS, Hasan Z, Gutierrez G, Katz NM, Seneff MG, Shah M. Lack of equivalence between central and mixed venous oxygen saturation. Chest. 2004;126:1891–6.CrossRefPubMed
25.
Zurück zum Zitat Van Beest PA, van Ingen J, Boerma EC, Holman ND, Groen H, Koopmans M, Spronk PE, Kuiper MA. No agreement of mixed venous and central venous saturation in sepsis, independent of sepsis origin. Crit Care. 2010;14:R219.CrossRefPubMedPubMedCentral Van Beest PA, van Ingen J, Boerma EC, Holman ND, Groen H, Koopmans M, Spronk PE, Kuiper MA. No agreement of mixed venous and central venous saturation in sepsis, independent of sepsis origin. Crit Care. 2010;14:R219.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Van der Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, Brochard L. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med. 2001;27:1606–13.CrossRefPubMed Van der Louw A, Cracco C, Cerf C, Harf A, Duvaldestin P, Lemaire F, Brochard L. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med. 2001;27:1606–13.CrossRefPubMed
27.
Zurück zum Zitat Press WH, Flannery BP, Teukolsky SA, Vetterling WT. Numerical recipes in Pascal. Cambridge: Cambridge University Press; 1989. Press WH, Flannery BP, Teukolsky SA, Vetterling WT. Numerical recipes in Pascal. Cambridge: Cambridge University Press; 1989.
28.
Zurück zum Zitat Fung N, Lasenby J, Jones JG, Ross-Russell R. Model-fitting for automated and robust determination of pulmonary oxygen exchange. In: Aghajan H, Augusto TG, Callaghan V, editors. Workshop proceedings of the 7th international conference on intelligent environments. IOS Press; 2011, pp 775–786. Fung N, Lasenby J, Jones JG, Ross-Russell R. Model-fitting for automated and robust determination of pulmonary oxygen exchange. In: Aghajan H, Augusto TG, Callaghan V, editors. Workshop proceedings of the 7th international conference on intelligent environments. IOS Press; 2011, pp 775–786.
Metadaten
Titel
Evaluation of a computer program for non-invasive determination of pulmonary shunt and ventilation-perfusion mismatch
verfasst von
Geoffrey G. Lockwood
Nick L. S. Fung
J. Gareth Jones
Publikationsdatum
01.12.2014
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2014
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9554-x

Weitere Artikel der Ausgabe 6/2014

Journal of Clinical Monitoring and Computing 6/2014 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.