Skip to main content
Erschienen in: European Radiology 8/2010

01.08.2010 | Contrast Media

Evaluation of contrast-enhanced magnetic resonance angiography (MRA) using Gd-DOTA compared with time-of-flight MRA in the diagnosis of clinically significant non-coronary arterial disease

verfasst von: Joon-Won Kang, Tae-Hwan Lim, Choong-Gon Choi, Gi-Young Ko, Jeong-Kon Kim, Tae-Won Kwon

Erschienen in: European Radiology | Ausgabe 8/2010

Einloggen, um Zugang zu erhalten

Abstract

Objectives

This trial assessed diagnostic accuracy of contrast-enhanced magnetic resonance angiography (MRA) with meglumine gadoterate (Gd-DOTA) at 3 Tesla (T) over unenhanced MRA at 3 T in non-coronary arterial diseases by comparing their accuracy with that of the gold standard, x-ray angiography.

Methods

Ninety-two patients with suspected non-coronary arterial disease underwent in fixed sequence unenhanced time-of flight (TOF) MRA, contrast-enhanced MRA using a Gd-DOTA bolus (intravenous bolus 0.1 mmol/kg) and x-ray angiography.

Results

Eighty-four patients (71 male, 13 female; median age 64.5 years) were included in an intent-to-treat efficacy analysis. Targeted vascular areas were aorto-iliac, calf, carotid, femoral, popliteal and renal. Within-patient accuracy was significantly higher with contrast-enhanced MRA using Gd-DOTA than with unenhanced MRA (p = 0.0003). There was 84.4 ± 17.5% agreement between contrast-enhanced MRA (Gd-DOTA) and x-ray angiography, compared with 76.8 ± 20.4% between non-enhanced MRA and x-ray angiography. Sensitivity and specificity were also better with Gd-DOTA compared with non-enhanced MRA at the segment level. Duration of the MRA procedure was 3.5 times shorter with Gd-DOTA compared with non-enhanced MRA. Six patients reported six mild or moderate adverse events. No serious adverse events occurred.

Conclusions

Contrast-enhanced MRA using Gd-DOTA at 3 T was superior to unenhanced TOF MRA in the vascular territories investigated.
Literatur
1.
Zurück zum Zitat Prince MR, Narasimham DL, Stanley JC, Chenevert TL, Williams DM, Marx MV, Cho KJ (1995) Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology 197:785–792PubMed Prince MR, Narasimham DL, Stanley JC, Chenevert TL, Williams DM, Marx MV, Cho KJ (1995) Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. Radiology 197:785–792PubMed
2.
Zurück zum Zitat Allard M, Doucet D, Kien P, Bonnemain B, Caille JM (1988) Experimental study of DOTA-gadolinium. Invest Radiol 23(Suppl 1):S271–S274PubMed Allard M, Doucet D, Kien P, Bonnemain B, Caille JM (1988) Experimental study of DOTA-gadolinium. Invest Radiol 23(Suppl 1):S271–S274PubMed
3.
Zurück zum Zitat Herborn CU, Honold E, Wolf M, Kemper J, Kinner S, Adam G, Barkhausen J (2007) Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA). Invest Radiol 42:58–62CrossRefPubMed Herborn CU, Honold E, Wolf M, Kemper J, Kinner S, Adam G, Barkhausen J (2007) Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA). Invest Radiol 42:58–62CrossRefPubMed
4.
Zurück zum Zitat Brichaux JC, Grenier N, Douws C (1991) MR angiography of renal and pancreatic transplants arteries. 10th Annual Meeting of the Society of Magnetic Resonance in Medicine, San Francisco, p 140 Brichaux JC, Grenier N, Douws C (1991) MR angiography of renal and pancreatic transplants arteries. 10th Annual Meeting of the Society of Magnetic Resonance in Medicine, San Francisco, p 140
5.
Zurück zum Zitat Loubeyre P, Revel D, Douek P, Delignette A, Baldy C, Genin G, Amiel M (1994) Dynamic contrast-enhanced MR angiography of pulmonary embolism: comparison with pulmonary angiography. AJR Am J Roentgenol 162:1035–1039PubMed Loubeyre P, Revel D, Douek P, Delignette A, Baldy C, Genin G, Amiel M (1994) Dynamic contrast-enhanced MR angiography of pulmonary embolism: comparison with pulmonary angiography. AJR Am J Roentgenol 162:1035–1039PubMed
6.
Zurück zum Zitat Revel D, Loubeyre P, Delignette A, Douek P, Amiel M (1993) Contrast-enhanced magnetic resonance tomoangiography: a new imaging technique for studying thoracic great vessels. Magn Reson Imaging 11:1101–1105CrossRefPubMed Revel D, Loubeyre P, Delignette A, Douek P, Amiel M (1993) Contrast-enhanced magnetic resonance tomoangiography: a new imaging technique for studying thoracic great vessels. Magn Reson Imaging 11:1101–1105CrossRefPubMed
7.
Zurück zum Zitat Kelle S, Nagel E (2007) Cardiovascular MRI at 3 T. Eur Radiol 17(Suppl 6):F42–F47PubMed Kelle S, Nagel E (2007) Cardiovascular MRI at 3 T. Eur Radiol 17(Suppl 6):F42–F47PubMed
8.
Zurück zum Zitat Habibi R, Krishnam MS, Lohan DG, Barkhordarian F, Jalili M, Saleh RS, Ruehm SG, Finn JP (2008) High-spatial-resolution lower extremity MR angiography at 3.0 T: contrast agent dose comparison study. Radiology 248:680–692CrossRefPubMed Habibi R, Krishnam MS, Lohan DG, Barkhordarian F, Jalili M, Saleh RS, Ruehm SG, Finn JP (2008) High-spatial-resolution lower extremity MR angiography at 3.0 T: contrast agent dose comparison study. Radiology 248:680–692CrossRefPubMed
9.
Zurück zum Zitat Kuhl CK, Träber F, Schild HH (2008) Whole-body high-field-strength (3.0-T) MR Imaging in Clinical Practice. Part I. Technical considerations and clinical applications. Radiology 246:675–696CrossRefPubMed Kuhl CK, Träber F, Schild HH (2008) Whole-body high-field-strength (3.0-T) MR Imaging in Clinical Practice. Part I. Technical considerations and clinical applications. Radiology 246:675–696CrossRefPubMed
10.
Zurück zum Zitat Willinek WA, Schild HH (2008) Clinical advantages of 3.0 T MRI over 1.5 T. Eur J Radiol 65:2–14CrossRefPubMed Willinek WA, Schild HH (2008) Clinical advantages of 3.0 T MRI over 1.5 T. Eur J Radiol 65:2–14CrossRefPubMed
11.
Zurück zum Zitat Fleiss JL (1973) Statistical methods for rates and proportions. John Wiley & Sons, New York Fleiss JL (1973) Statistical methods for rates and proportions. John Wiley & Sons, New York
12.
Zurück zum Zitat Thurnher S, Miller S, Schneider G, Ballarati C, Bongartz G, Herborn CU, Schoenberg S, Cova MA, Morana G, Niazi K, Iezzi R, Taupitz M, Bluemke DA, Kreitner KF, Kirchin MA, Pirovano G (2007) Diagnostic performance of gadobenate dimeglumine-enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicentre trial. AJR Am J Roentgenol 189:1223–1237CrossRefPubMed Thurnher S, Miller S, Schneider G, Ballarati C, Bongartz G, Herborn CU, Schoenberg S, Cova MA, Morana G, Niazi K, Iezzi R, Taupitz M, Bluemke DA, Kreitner KF, Kirchin MA, Pirovano G (2007) Diagnostic performance of gadobenate dimeglumine-enhanced MR angiography of the iliofemoral and calf arteries: a large-scale multicentre trial. AJR Am J Roentgenol 189:1223–1237CrossRefPubMed
13.
Zurück zum Zitat Pereles FS, Collins JD, Carr JC, Francois C, Morasch MD, McCarthy RM, Krupinski EA, Butler GM, Finn JP (2006) Accuracy of stepping-table lower extremity MR angiography with dual-level bolus timing and separate calf acquisition: hybrid peripheral MR angiography. Radiology 240:283–290CrossRefPubMed Pereles FS, Collins JD, Carr JC, Francois C, Morasch MD, McCarthy RM, Krupinski EA, Butler GM, Finn JP (2006) Accuracy of stepping-table lower extremity MR angiography with dual-level bolus timing and separate calf acquisition: hybrid peripheral MR angiography. Radiology 240:283–290CrossRefPubMed
14.
Zurück zum Zitat D’Onofrio M, Mansueto G, Faccioli N, Guarise A, Tamellini P, Bogina G, Pozzi Mucelli R (2006) Doppler ultrasound and contrast-enhanced magnetic resonance angiography in assessing carotid artery stenosis. Radiol Med (Torino) 111:93–103CrossRef D’Onofrio M, Mansueto G, Faccioli N, Guarise A, Tamellini P, Bogina G, Pozzi Mucelli R (2006) Doppler ultrasound and contrast-enhanced magnetic resonance angiography in assessing carotid artery stenosis. Radiol Med (Torino) 111:93–103CrossRef
15.
Zurück zum Zitat Yin D, Baum RA, Carpenter JP, Langlotz CP, Pentecost MJ (1995) Cost-effectiveness of MR angiography in cases of limb-threatening peripheral vascular disease. Radiology 194:757–764PubMed Yin D, Baum RA, Carpenter JP, Langlotz CP, Pentecost MJ (1995) Cost-effectiveness of MR angiography in cases of limb-threatening peripheral vascular disease. Radiology 194:757–764PubMed
16.
Zurück zum Zitat Nelemans PJ, Leiner T, de Vet HCW, van Engelshoven JM (2000) Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography. Radiology 217:105–114PubMed Nelemans PJ, Leiner T, de Vet HCW, van Engelshoven JM (2000) Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography. Radiology 217:105–114PubMed
17.
Zurück zum Zitat Wardlaw JM, Chappell FM, Best JJ, Wartolowska K, Berry E, NHS Research and Development Health Technology Assessment Carotid Stenosis Imaging Group (2006) Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis. Lancet 367:1503–1512CrossRefPubMed Wardlaw JM, Chappell FM, Best JJ, Wartolowska K, Berry E, NHS Research and Development Health Technology Assessment Carotid Stenosis Imaging Group (2006) Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis. Lancet 367:1503–1512CrossRefPubMed
18.
Zurück zum Zitat Kwee TC, Kwee RM (2007) MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: a systematic review and meta-analysis. Neuroradiology. 49:703–713CrossRefPubMed Kwee TC, Kwee RM (2007) MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: a systematic review and meta-analysis. Neuroradiology. 49:703–713CrossRefPubMed
19.
Zurück zum Zitat Lin W, An H, Chen Y, Nicholas P, Zhai G, Gerig G, Gilmore J, Bullitt E (2003) Practical consideration for 3T imaging. Magn Reson Imaging Clin N Am 11:615–639CrossRefPubMed Lin W, An H, Chen Y, Nicholas P, Zhai G, Gerig G, Gilmore J, Bullitt E (2003) Practical consideration for 3T imaging. Magn Reson Imaging Clin N Am 11:615–639CrossRefPubMed
20.
Zurück zum Zitat Ganguli S, Pedrosa I, Smith MP, Niendorf ER, Fredericks S, Rofsky NM (2008) Low dose pedal magnetic resonance angiography at 3 Tesla with time-resolved imaging of contrast kinetics. A feasibility study. Invest Radiol 43:650–655 Ganguli S, Pedrosa I, Smith MP, Niendorf ER, Fredericks S, Rofsky NM (2008) Low dose pedal magnetic resonance angiography at 3 Tesla with time-resolved imaging of contrast kinetics. A feasibility study. Invest Radiol 43:650–655
21.
Zurück zum Zitat Collins R, Cranny G, Burch J, Aguiar-Ibanez R, Craig D, Wright K, Berry E, Gough M, Kleijnen J, Westwood M (2007) A systematic review of duplex ultrasound, magnetic resonance angiography and computed tomography angiography for the diagnosis and assessment of symptomatic lower limb peripheral arterial disease. Health Technol Assess 11(20):1–184 iii–iv, xi–xiii Collins R, Cranny G, Burch J, Aguiar-Ibanez R, Craig D, Wright K, Berry E, Gough M, Kleijnen J, Westwood M (2007) A systematic review of duplex ultrasound, magnetic resonance angiography and computed tomography angiography for the diagnosis and assessment of symptomatic lower limb peripheral arterial disease. Health Technol Assess 11(20):1–184 iii–iv, xi–xiii
22.
Zurück zum Zitat Michaely HJ, Kramer H, Attenberger U, Sourbron SP, Weckbach S, Reiser MF, Schoenberg SO (2007) Renal magnetic resonance angiography at 3.0 T: technical feasibility and clinical perspectives. Top Magn Reson Imaging 18:117–125CrossRefPubMed Michaely HJ, Kramer H, Attenberger U, Sourbron SP, Weckbach S, Reiser MF, Schoenberg SO (2007) Renal magnetic resonance angiography at 3.0 T: technical feasibility and clinical perspectives. Top Magn Reson Imaging 18:117–125CrossRefPubMed
23.
Zurück zum Zitat Michaely HJ, Attenberger UI, Kramer H, Nael K, Reiser MF, Schoenberg SO (2007) Abdominal and pelvic MR angiography. Magn Reson Imaging Clin N Am 15:301–314CrossRefPubMed Michaely HJ, Attenberger UI, Kramer H, Nael K, Reiser MF, Schoenberg SO (2007) Abdominal and pelvic MR angiography. Magn Reson Imaging Clin N Am 15:301–314CrossRefPubMed
24.
Zurück zum Zitat Hansen T, Ahlström H, Wikström J, Lind K, Johansson L (2008) A total atherosclerotic score for whole-body MRA and its relation to traditional cardiovascular risk factors. Eur Radiol 18:1174–1180CrossRefPubMed Hansen T, Ahlström H, Wikström J, Lind K, Johansson L (2008) A total atherosclerotic score for whole-body MRA and its relation to traditional cardiovascular risk factors. Eur Radiol 18:1174–1180CrossRefPubMed
25.
Zurück zum Zitat Tombach B, Bohndorf K, Brodtrager W, Claussen CD, Düber C, Galanski M, Grabbe E, Gortenuti G, Kuhn M, Gross-Fengels W, Hammerstingl R, Happel B, Heinz-Peer G, Jung G, Kittner T, Lagalla R, Lengsfeld P, Loose R, Oyen RHG, Pavlici P, Pering C, Pozzi-Mucelli R, Persigehl T, Reimer P, Renken NS, Richter GM, Rummeny EJ, Schäfer F, Szczerbo-Trojanowska M, Urbanik A, Vogl TJ, Hajek P (2008) Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions: results of a multicenter, single-blind, interindividual, randomized clinical phase III trial. Eur Radiol 18:2610–2619CrossRefPubMed Tombach B, Bohndorf K, Brodtrager W, Claussen CD, Düber C, Galanski M, Grabbe E, Gortenuti G, Kuhn M, Gross-Fengels W, Hammerstingl R, Happel B, Heinz-Peer G, Jung G, Kittner T, Lagalla R, Lengsfeld P, Loose R, Oyen RHG, Pavlici P, Pering C, Pozzi-Mucelli R, Persigehl T, Reimer P, Renken NS, Richter GM, Rummeny EJ, Schäfer F, Szczerbo-Trojanowska M, Urbanik A, Vogl TJ, Hajek P (2008) Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions: results of a multicenter, single-blind, interindividual, randomized clinical phase III trial. Eur Radiol 18:2610–2619CrossRefPubMed
Metadaten
Titel
Evaluation of contrast-enhanced magnetic resonance angiography (MRA) using Gd-DOTA compared with time-of-flight MRA in the diagnosis of clinically significant non-coronary arterial disease
verfasst von
Joon-Won Kang
Tae-Hwan Lim
Choong-Gon Choi
Gi-Young Ko
Jeong-Kon Kim
Tae-Won Kwon
Publikationsdatum
01.08.2010
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 8/2010
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1764-0

Weitere Artikel der Ausgabe 8/2010

European Radiology 8/2010 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.