Skip to main content
Erschienen in: Journal of Digital Imaging 3/2013

01.06.2013

Evaluation of Irreversible Compression Ratios for Medical Images Thin Slice CT and Update of Canadian Association of Radiologists (CAR) Guidelines

verfasst von: David Koff, Peter Bak, André Matos, Geoff Norman

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 3/2013

Einloggen, um Zugang zu erhalten

Abstract

In June 2008, the Canadian Association of Radiologists published its Standards for Irreversible Compression in Digital Diagnostic Imaging within Radiology (Canadian Association of Radiologists 2012). The study suggested that at low levels of compression there was no difference in diagnostic accuracy between uncompressed JPEG and JPEG 2000. There were two exceptions; CT neurological and CT body images resulted in lower rating of image quality (Koff et al., J Digit Imaging 22(6):569–78, 2009). The slice thicknesses used in the previous study were greater than 5 mm. However, other studies (Ringl et al., Radiology 240:869–87, 2006) suggest that thin CT slices might modify image tolerance to irreversible compression. Therefore, a new clinical evaluation using CT slices less than 3 mm was initiated. We examined CT images in four body regions (chest, body, musculoskeletal, and neurological). Twenty-five radiologists from across Canada participated. Each read a total of 70 CTs in his specialty; 10 at each of seven levels of compression (uncompressed, JPEG and JPEG 2000 at low, medium, and high compression (varying by region)). Each reader diagnosed the case, rated his confidence, and compared the compressed to the uncompressed image and rated the degree of degradation. Data were analyzed for sensitivity, specificity, accuracy, confidence, and degradation at three levels and two types of compression as well as the original image. There were no overall differences in sensitivity, specificity, accuracy, or confidence. JPEG images, at all levels of compression, were rated lower in terms of perceived difference (4.16/5 vs. 4.53/5 for JPEG 2000 and 4.68/5 for uncompressed). However, the rating of perceived difference was not significantly correlated with accuracy. Analysis of individual body regions did not reveal any systematic effects of compression in any region.
Literatur
2.
Zurück zum Zitat Koff D, Bak P, Brownrigg P,Hosseinzadeh D, Khademi A, Kiss A, Lepanto L, Michalak T, Shulman H, and Volkening A: Pan-Canadian Evaluation of Irreversible Compression Ratios (“Lossy”Compression) for Development of National Guidelines - J Digit Imaging. 2009 Dec;22(6):569–78. Epub 2008 Oct 18CrossRef Koff D, Bak P, Brownrigg P,Hosseinzadeh D, Khademi A, Kiss A, Lepanto L, Michalak T, Shulman H, and Volkening A: Pan-Canadian Evaluation of Irreversible Compression Ratios (“Lossy”Compression) for Development of National Guidelines - J Digit Imaging. 2009 Dec;22(6):569–78. Epub 2008 Oct 18CrossRef
3.
Zurück zum Zitat Ringl H, Schernthaner RE, Bankier AA, Weber M, Prokop M, Herold CJ, Schaefer-Prokop C: JPEG2000 compression of thin-section ct images of the lung: effect of compression ratio on image quality. Radiology 240:869–87, 2006PubMedCrossRef Ringl H, Schernthaner RE, Bankier AA, Weber M, Prokop M, Herold CJ, Schaefer-Prokop C: JPEG2000 compression of thin-section ct images of the lung: effect of compression ratio on image quality. Radiology 240:869–87, 2006PubMedCrossRef
4.
Zurück zum Zitat Bak P: Will the use of irreversible compression become a standard of practice? SCAR News 18:10, 2006 Bak P: Will the use of irreversible compression become a standard of practice? SCAR News 18:10, 2006
5.
Zurück zum Zitat McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT. Radiation dose in CT, RadioGraphics 2002; 22:1541–1553PubMedCrossRef McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT. Radiation dose in CT, RadioGraphics 2002; 22:1541–1553PubMedCrossRef
6.
Zurück zum Zitat Woo HS, Kim KJ, Kim TJ Hahn S Kim B Lee KH. JPEG 2000 compression of abdominal CT: difference in tolerance between thin- and thick-section images AJR Am J Roentgenol. 2007;189:535–41PubMedCrossRef Woo HS, Kim KJ, Kim TJ Hahn S Kim B Lee KH. JPEG 2000 compression of abdominal CT: difference in tolerance between thin- and thick-section images AJR Am J Roentgenol. 2007;189:535–41PubMedCrossRef
7.
Zurück zum Zitat Yamamoto S, Johkoh T, Mihara N, et al. Evaluation of compressed lung CT image quality using quantitative analysis. Radiat Med 2001; 19:321–329PubMed Yamamoto S, Johkoh T, Mihara N, et al. Evaluation of compressed lung CT image quality using quantitative analysis. Radiat Med 2001; 19:321–329PubMed
8.
Zurück zum Zitat Siddiqui KM, Siegel EL, Reiner BI, Johnson JP, Crave O, Nadar M.: Improved image compression at various slice thickness for multi-slice CT using 3D JPEG 2000 (part 2) in comparison with conventional 2D compression. (abstr) Society for Computer Applications in Radiology Scientific Abstracts. Leesburg, VA: Society for Computer Applications in Radiology, 87–88, 2004 Siddiqui KM, Siegel EL, Reiner BI, Johnson JP, Crave O, Nadar M.: Improved image compression at various slice thickness for multi-slice CT using 3D JPEG 2000 (part 2) in comparison with conventional 2D compression. (abstr) Society for Computer Applications in Radiology Scientific Abstracts. Leesburg, VA: Society for Computer Applications in Radiology, 87–88, 2004
9.
Zurück zum Zitat Siegel EL, Siddiqui KM, Johnson JP, et al.: Compression of multislice CT: 2D vs. 3D JPEG2000 and effects of slice thickness. SPIE Proceedings. Bellingham,WA: SPIE,162–170, 2005 Siegel EL, Siddiqui KM, Johnson JP, et al.: Compression of multislice CT: 2D vs. 3D JPEG2000 and effects of slice thickness. SPIE Proceedings. Bellingham,WA: SPIE,162–170, 2005
10.
Zurück zum Zitat Lubin J. The use of psychophysical data and models in the analysis of display system performance. In: Watson AB, ed. Digital images and human vision. Cambridge, MA: MIT Press, 1993:163–178 Lubin J. The use of psychophysical data and models in the analysis of display system performance. In: Watson AB, ed. Digital images and human vision. Cambridge, MA: MIT Press, 1993:163–178
11.
Zurück zum Zitat Driggers, RG: The Encyclopedia of optical engineering, volume 12, New York: Dekker, 2003 Driggers, RG: The Encyclopedia of optical engineering, volume 12, New York: Dekker, 2003
Metadaten
Titel
Evaluation of Irreversible Compression Ratios for Medical Images Thin Slice CT and Update of Canadian Association of Radiologists (CAR) Guidelines
verfasst von
David Koff
Peter Bak
André Matos
Geoff Norman
Publikationsdatum
01.06.2013
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2013
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9542-y

Weitere Artikel der Ausgabe 3/2013

Journal of Digital Imaging 3/2013 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie