Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 4/2016

20.11.2015 | Original Article

Experimental determination of the elbow’s center of rotation using the VICON™ optoelectronic motion capture system

verfasst von: Elvire Guerre, Pascale Laronde, Jérôme Cussonneau, Christian Fontaine, Guillaume Wavreille

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Knowledge of elbow kinematics is essential to better understand this joint. There is currently no reliable dynamic method to accurately study the elbow joint in a non-invasive manner. The goal of this study was to implement an accurate protocol to study in vivo elbow kinematics using a VICON™ optoelectronic motion analysis system.

Méthods

The elbow’s centers of rotation (CR) were calculated for 10 anatomical specimens. The effect of skin movement was determined by comparing measurements taken using skin surface markers and bone-fixed markers. The validated protocol was then used in 30 healthy subjects who underwent passive elbow joint movements.

Results

The elbow’s CR was found to be distal (7 ± 14 mm), lateral (4 ± 9 mm) and anterior (4 ± 10 mm) to the medial epicondyle in vitro. Mean CR values for anatomical specimens did not differ whether calculated using the skin-based or bone-fixed markers.

Conclusion

This study has validated a dynamic, non-invasive, and accurate method for locating the elbow’s center of rotation. This preliminary study thus found a different center of rotation of the one in the middle of the trochlea previously thought. This could lead us to reflect on the designs of our prostheses to reduce the mechanical stresses and the risk of loosening.
Literatur
1.
Zurück zum Zitat Anglin C, Wyss UP (2000) Review of arm motion analyses. Proc Inst Mech Eng H 55:214–541 Anglin C, Wyss UP (2000) Review of arm motion analyses. Proc Inst Mech Eng H 55:214–541
2.
4.
Zurück zum Zitat Bottlang M, Madey SM, Steyers CM, Marsh JL, Brown TD (2000) Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking. J Orthop Res 18:195–202CrossRefPubMed Bottlang M, Madey SM, Steyers CM, Marsh JL, Brown TD (2000) Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking. J Orthop Res 18:195–202CrossRefPubMed
5.
Zurück zum Zitat Chantelot C, Wavreille G, Dos Remedios C, Landejerit B, Fontaine C, Hildebrand H (2008) Intra-articular compressive stress of the elbow joint in extension: an experimental study using Fuji films. Surg Radiol Anat 11:30–103. doi:10.1007/s00276-007-0297-y Chantelot C, Wavreille G, Dos Remedios C, Landejerit B, Fontaine C, Hildebrand H (2008) Intra-articular compressive stress of the elbow joint in extension: an experimental study using Fuji films. Surg Radiol Anat 11:30–103. doi:10.​1007/​s00276-007-0297-y
6.
Zurück zum Zitat Deland JT, Garg A, Walker PS (1987) Biomechanical basis for elbow hinge-distractor design. Clin Orthop Relat Res 12:215–303 Deland JT, Garg A, Walker PS (1987) Biomechanical basis for elbow hinge-distractor design. Clin Orthop Relat Res 12:215–303
8.
9.
Zurück zum Zitat Ericson A, Arndt A, Stark A, Noz ME, Maguire GQ Jr, Zeleznik MP et al (2007) Fusion of radiostereometric analysis data into computed tomography space: application to the elbow joint. J Biomech 40:296–304. doi:10.1016/j.jbiomech.2006.01.019 Ericson A, Arndt A, Stark A, Noz ME, Maguire GQ Jr, Zeleznik MP et al (2007) Fusion of radiostereometric analysis data into computed tomography space: application to the elbow joint. J Biomech 40:296–304. doi:10.​1016/​j.​jbiomech.​2006.​01.​019
10.
11.
Zurück zum Zitat Goto A, Moritomo H, Murase T, Oka K, Sugamoto K, Arimura T et al (2004) In vivo elbow biomechanical analysis during flexion: three-dimensional motion analysis using magnetic resonance imaging. J Shoulder Elbow Surg 7:13–441. doi:10.1016/j.jse.2004.01.022 Goto A, Moritomo H, Murase T, Oka K, Sugamoto K, Arimura T et al (2004) In vivo elbow biomechanical analysis during flexion: three-dimensional motion analysis using magnetic resonance imaging. J Shoulder Elbow Surg 7:13–441. doi:10.​1016/​j.​jse.​2004.​01.​022
12.
Zurück zum Zitat Gschwend N, Simmen BR, Matejovsky Z (1996) Late complications in elbow arthroplasty. J Shoulder Elbow Surg 5:86–96CrossRefPubMed Gschwend N, Simmen BR, Matejovsky Z (1996) Late complications in elbow arthroplasty. J Shoulder Elbow Surg 5:86–96CrossRefPubMed
14.
Zurück zum Zitat London JT (1981) Kinematics of the elbow. J Bone Joint Surg Am 35:63–529 London JT (1981) Kinematics of the elbow. J Bone Joint Surg Am 35:63–529
15.
Zurück zum Zitat Mino DE, Palmer AK, Levinsohn EM (1983) The role of radiography and computerized tomography in the diagnosis of subluxation and dislocation of the distal radioulnar joint. J Hand Surg Am 8:23–31CrossRefPubMed Mino DE, Palmer AK, Levinsohn EM (1983) The role of radiography and computerized tomography in the diagnosis of subluxation and dislocation of the distal radioulnar joint. J Hand Surg Am 8:23–31CrossRefPubMed
16.
Zurück zum Zitat Miyake J, Shimada K, Moritomo H, Kataoka T, Murase T, Sugamoto K (2013) Kinematic Changes in elbow osteoarthritis: in vivo and 3-dimensional analysis using computed tomographic data. J Hand Surg Am 64:38–957. doi:10.1016/j.jhsa.2013.02.006 Miyake J, Shimada K, Moritomo H, Kataoka T, Murase T, Sugamoto K (2013) Kinematic Changes in elbow osteoarthritis: in vivo and 3-dimensional analysis using computed tomographic data. J Hand Surg Am 64:38–957. doi:10.​1016/​j.​jhsa.​2013.​02.​006
17.
Zurück zum Zitat Morrey BF, Chao EY (1976) Passive motion of the elbow joint. J Bone Joint Surg Am 8:58–501 Morrey BF, Chao EY (1976) Passive motion of the elbow joint. J Bone Joint Surg Am 8:58–501
18.
Zurück zum Zitat Nakamura T, Yabe Y, Horiuchi Y, Yamazaki N (1999) In vivo motion analysis of forearm rotation utilizing magnetic resonance imaging. Clin Biomech 20:14–315 Nakamura T, Yabe Y, Horiuchi Y, Yamazaki N (1999) In vivo motion analysis of forearm rotation utilizing magnetic resonance imaging. Clin Biomech 20:14–315
19.
Zurück zum Zitat O’Driscoll SW, An KN, Korinek S, Morrey BF (1992) Kinematics of semi-constrained total elbow arthroplasty. J Bone Joint Surg Br 9:74–297 O’Driscoll SW, An KN, Korinek S, Morrey BF (1992) Kinematics of semi-constrained total elbow arthroplasty. J Bone Joint Surg Br 9:74–297
20.
Zurück zum Zitat Piazza SJ, Okita N, Cavanagh PR (2001) Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation. J Biomech 73:34–967 Piazza SJ, Okita N, Cavanagh PR (2001) Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation. J Biomech 73:34–967
21.
Zurück zum Zitat Ray RD, Johnson RJ, Jameson RM (1951) Rotation of the forearm; an experimental study of pronation and supination. J Bone Joint Surg Am 6:33–993 Ray RD, Johnson RJ, Jameson RM (1951) Rotation of the forearm; an experimental study of pronation and supination. J Bone Joint Surg Am 6:33–993
22.
Zurück zum Zitat Schmidt R, Disselhorst-Klug C, Silny J, Rau G (1999) A marker-based measurement procedure for unconstrained wrist and elbow motions. J Biomech 21:32–6151 Schmidt R, Disselhorst-Klug C, Silny J, Rau G (1999) A marker-based measurement procedure for unconstrained wrist and elbow motions. J Biomech 21:32–6151
23.
Zurück zum Zitat Stanley D (1994) Prevalence and etiology of symptomatic elbow osteoarthritis. J Shoulder Elbow Surg 9:3–386 Stanley D (1994) Prevalence and etiology of symptomatic elbow osteoarthritis. J Shoulder Elbow Surg 9:3–386
24.
Zurück zum Zitat Stokdijk M, Biegstraaten M, Ormel W, de Boer YA, Veeger HE, Rozing PM (2000) Determining the optimal flexion-extension axis of the elbow in vivo: a study of interobserver and intraobserver reliability. J Biomech 45:33–1139 Stokdijk M, Biegstraaten M, Ormel W, de Boer YA, Veeger HE, Rozing PM (2000) Determining the optimal flexion-extension axis of the elbow in vivo: a study of interobserver and intraobserver reliability. J Biomech 45:33–1139
25.
Zurück zum Zitat Tay SC, Berger RA, Tomita K, Tan ET, Amrami KK, An K-N (2007) In vivo three-dimensional displacement of the distal radioulnar joint during resisted forearm rotation. J Hand Surg Am 8:32–450. doi:10.1016/j.jhsa.2007.01.007 Tay SC, Berger RA, Tomita K, Tan ET, Amrami KK, An K-N (2007) In vivo three-dimensional displacement of the distal radioulnar joint during resisted forearm rotation. J Hand Surg Am 8:32–450. doi:10.​1016/​j.​jhsa.​2007.​01.​007
26.
Zurück zum Zitat Tay SC, Primak AN, Fletcher JG, Schmidt B, Amrami KK, Berger RA et al (2007) Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model. Skeletal Radiol 9:36–1163. doi:10.1007/s00256-007-0374-7 Tay SC, Primak AN, Fletcher JG, Schmidt B, Amrami KK, Berger RA et al (2007) Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model. Skeletal Radiol 9:36–1163. doi:10.​1007/​s00256-007-0374-7
28.
Zurück zum Zitat Vieilledent S (2002) Comparaison de systèmes d’analyse du mouvement 3D. Rapport de l’INSEP, Projet subventionné par le ministère de la Jeunesse et des Sports, p 54 Vieilledent S (2002) Comparaison de systèmes d’analyse du mouvement 3D. Rapport de l’INSEP, Projet subventionné par le ministère de la Jeunesse et des Sports, p 54
30.
Zurück zum Zitat Weinberg AM, Pietsch IT, Krefft M, Pape HC, van Griensven M, Helm MB et al (2001) Pronation and supination of the forearm. With special reference to the humero-ulnar articulation. Unfallchirurg 9:104–404 Weinberg AM, Pietsch IT, Krefft M, Pape HC, van Griensven M, Helm MB et al (2001) Pronation and supination of the forearm. With special reference to the humero-ulnar articulation. Unfallchirurg 9:104–404
Metadaten
Titel
Experimental determination of the elbow’s center of rotation using the VICON™ optoelectronic motion capture system
verfasst von
Elvire Guerre
Pascale Laronde
Jérôme Cussonneau
Christian Fontaine
Guillaume Wavreille
Publikationsdatum
20.11.2015
Verlag
Springer Paris
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 4/2016
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-015-1589-2

Weitere Artikel der Ausgabe 4/2016

Surgical and Radiologic Anatomy 4/2016 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.