Skip to main content
Erschienen in: Intensive Care Medicine 12/2003

01.12.2003 | Original

Factors determining the appearance of glucose in upper and lower respiratory tract secretions

verfasst von: Barbara J. Philips, Jean-Xavier Meguer, Jonathan Redman, Emma H. Baker

Erschienen in: Intensive Care Medicine | Ausgabe 12/2003

Einloggen, um Zugang zu erhalten

Abstract

Objectives

(a) To describe the glucose content of normal human airways secretions; (b) to observe the effects of hyperglycemia and airways inflammation on airways glucose.

Design

Observational studies.

Settings

(a) St George's Hospital Medical School; (b) diabetes mellitus outpatient clinics; (c) adult general intensive care unit.

Patients

Nineteen healthy volunteers, 24 volunteers with acute rhinitis, 20 patients with diabetes mellitus, and 60 patients admitted to a general adult intensive care unit.

Measurements

(a) Non-ventilated patients: simultaneous measurement of blood and nasal glucose concentrations; (b) ICU patients: simultaneous blood, nasal, and endotracheal (ET) glucose concentrations.

Results

Nasal glucose was undetectable in all healthy volunteers. Glucose was detected in 12/24 volunteers with acute viral rhinitis [1 (1–2) mmol l−1] and 18/20 people with diabetes [4 (2–7) mmol l−1]. Glucose was detected in the ET secretions of 31/60 ventilated patients on ICU. Patients with ET glucose had significantly higher blood glucose (9.8±0.4 mmol l−1) than patients without ET glucose (7.2±0.3 mmol l−1, P<0.001), and all patients with blood glucose >10.1 mmol l−1 had glucose in ET secretions. Enteral nutrition did not affect the presence or concentration of glucose in ET secretions.

Conclusions

Glucose is not normally present in airways secretions, but appears where hyperglycaemia or epithelial inflammation occur. The detection of glucose cannot reliably be used to detect enteral feed aspiration.
Literatur
1.
Zurück zum Zitat Barker PM, Boyd CA, Ramsden CA, Strang LB, Walters DV (1989) Pulmonary glucose transport in the fetal sheep. J Physiol 409:15–27CrossRef Barker PM, Boyd CA, Ramsden CA, Strang LB, Walters DV (1989) Pulmonary glucose transport in the fetal sheep. J Physiol 409:15–27CrossRef
2.
Zurück zum Zitat Basset G, Saumon G, Bouchonnet F, Crone C (1988) Apical sodium-sugar transport in pulmonary epithelium in situ. Biochim Biophys Acta 942:11–18CrossRef Basset G, Saumon G, Bouchonnet F, Crone C (1988) Apical sodium-sugar transport in pulmonary epithelium in situ. Biochim Biophys Acta 942:11–18CrossRef
3.
Zurück zum Zitat Saumon G, Seigne E, Clerici C (1990) Evidence for a sodium-dependent sugar transport in rat tracheal epithelium. Biochim Biophys Acta 1023:313–318CrossRef Saumon G, Seigne E, Clerici C (1990) Evidence for a sodium-dependent sugar transport in rat tracheal epithelium. Biochim Biophys Acta 1023:313–318CrossRef
4.
Zurück zum Zitat Hull HF, Morrow G (1975) Glucorrhea revisited. Prolonged promulgation of another plastic pearl. Jama 234:1052–1053CrossRef Hull HF, Morrow G (1975) Glucorrhea revisited. Prolonged promulgation of another plastic pearl. Jama 234:1052–1053CrossRef
5.
Zurück zum Zitat Metheny NA, St John RE, Clouse RE (1998) Measurement of glucose in tracheobronchial secretions to detect aspiration of enteral feedings. Heart Lung 27:285–292CrossRef Metheny NA, St John RE, Clouse RE (1998) Measurement of glucose in tracheobronchial secretions to detect aspiration of enteral feedings. Heart Lung 27:285–292CrossRef
6.
Zurück zum Zitat Kinsey GC, Murray MJ, Swensen SJ, Miles JM (1994) Glucose content of tracheal aspirates: implications for the detection of tube feeding aspiration. Crit Care Med 22:1557–1562CrossRef Kinsey GC, Murray MJ, Swensen SJ, Miles JM (1994) Glucose content of tracheal aspirates: implications for the detection of tube feeding aspiration. Crit Care Med 22:1557–1562CrossRef
7.
Zurück zum Zitat Winterbauer RH, Durning RB Jr, Barron E, McFadden MC (1981) Aspirated nasogastric feeding solution detected by glucose strips. Ann Intern Med 95:67–68CrossRef Winterbauer RH, Durning RB Jr, Barron E, McFadden MC (1981) Aspirated nasogastric feeding solution detected by glucose strips. Ann Intern Med 95:67–68CrossRef
8.
Zurück zum Zitat Van Crombrugge P, Rottiers R, Vermeulen A (1985) Self blood glucose monitoring: evaluation of Haemo-Glukotest 20–800R, Visidex I and Reflolux. Diabete Metab 11:210–215 Van Crombrugge P, Rottiers R, Vermeulen A (1985) Self blood glucose monitoring: evaluation of Haemo-Glukotest 20–800R, Visidex I and Reflolux. Diabete Metab 11:210–215
9.
Zurück zum Zitat Ishikawa N, Oguri T, Isobe T, Fujitaka K, Kohno N (2001) SGLT gene expression in primary lung cancers and their metastatic lesions. Jpn J Cancer Res 92:874–879CrossRef Ishikawa N, Oguri T, Isobe T, Fujitaka K, Kohno N (2001) SGLT gene expression in primary lung cancers and their metastatic lesions. Jpn J Cancer Res 92:874–879CrossRef
10.
Zurück zum Zitat Johansen K, Svendsen PA, Lorup B (1984) Variations in renal threshold for glucose in Type 1 (insulin-dependent) diabetes mellitus. Diabetologia 26:180–182CrossRef Johansen K, Svendsen PA, Lorup B (1984) Variations in renal threshold for glucose in Type 1 (insulin-dependent) diabetes mellitus. Diabetologia 26:180–182CrossRef
11.
Zurück zum Zitat Ruhnau B, Faber OK, Borch-Johnsen K, Thorsteinsson B (1997) Renal threshold for glucose in non-insulin-dependent diabetic patients. Diabetes Res Clin Pract 36:27–33CrossRef Ruhnau B, Faber OK, Borch-Johnsen K, Thorsteinsson B (1997) Renal threshold for glucose in non-insulin-dependent diabetic patients. Diabetes Res Clin Pract 36:27–33CrossRef
12.
Zurück zum Zitat Reuterving CO, Reuterving G, Hagg E, Ericson T (1987) Salivary flow rate and salivary glucose concentration in patients with diabetes mellitus influence of severity of diabetes. Diabete Metab 13:457–462PubMed Reuterving CO, Reuterving G, Hagg E, Ericson T (1987) Salivary flow rate and salivary glucose concentration in patients with diabetes mellitus influence of severity of diabetes. Diabete Metab 13:457–462PubMed
13.
Zurück zum Zitat Grenby TH, Mistry M (2000) Properties of maltodextrins and glucose syrups in experiments in vitro and in the diets of laboratory animals, relating to dental health. Br J Nutr 84:565–574CrossRef Grenby TH, Mistry M (2000) Properties of maltodextrins and glucose syrups in experiments in vitro and in the diets of laboratory animals, relating to dental health. Br J Nutr 84:565–574CrossRef
14.
Zurück zum Zitat Knowles MR, Robinson JM, Wood RE, Pue CA, Mentz WM, Wager GC, Gatzy JT, Boucher RC (1997) Ion composition of airway surface liquid of patients with cystic fibrosis as compared with normal and disease-control subjects. J Clin Invest 100:2588–2595CrossRef Knowles MR, Robinson JM, Wood RE, Pue CA, Mentz WM, Wager GC, Gatzy JT, Boucher RC (1997) Ion composition of airway surface liquid of patients with cystic fibrosis as compared with normal and disease-control subjects. J Clin Invest 100:2588–2595CrossRef
Metadaten
Titel
Factors determining the appearance of glucose in upper and lower respiratory tract secretions
verfasst von
Barbara J. Philips
Jean-Xavier Meguer
Jonathan Redman
Emma H. Baker
Publikationsdatum
01.12.2003
Verlag
Springer Berlin Heidelberg
Erschienen in
Intensive Care Medicine / Ausgabe 12/2003
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-003-1961-2

Weitere Artikel der Ausgabe 12/2003

Intensive Care Medicine 12/2003 Zur Ausgabe

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Beutel versus Maschine: Beste Beatmungstechnik bei Herzstillstand gesucht

02.05.2024 Kardiopulmonale Reanimation Nachrichten

Stehen die Chancen auf eine Rückkehr der Spontanzirkulation nach Herz-Kreislauf-Stillstand bei manueller oder maschineller Beatmung besser? Und unterscheidet sich das neurologische Outcome nach der Reanimation? Das belgische Herzstillstand-Register liefert die Daten für einen direkten Vergleich zwischen Beutel und Beatmungsgerät.

Tipps für den Umgang mit Behandlungsfehlern

01.05.2024 DGIM 2024 Kongressbericht

Es ist nur eine Frage der Zeit, bis es zu einem Zwischenfall kommt und ein Behandlungsfehler passiert. Doch wenn Ärztinnen und Ärzte gut vorbereitet sind, schaffen es alle Beteiligten den Umständen entsprechend gut durch diese Krise. 

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.