Abstract

The aim of this article is to provide Radiologists and Nuclear Medicine physicians the basic information required to understand how PET/MR scanners work, what are their limitations and how to evaluate their performance. It will cover the operational principles of standalone PET and MR imaging, as well as the technical challenges of creating a hybrid system and how they have been solved in the now commercially available scanners. Guidelines will be provided to interpret the main performance figures of hybrid PET/MR systems.
Literatur
1.
Zurück zum Zitat Ratib O, Beyer T (2011) Whole-body hybrid PET/MRI: ready for clinical use? Eur J Nucl Med Mol Imaging 38:992–995PubMedCrossRef Ratib O, Beyer T (2011) Whole-body hybrid PET/MRI: ready for clinical use? Eur J Nucl Med Mol Imaging 38:992–995PubMedCrossRef
2.
Zurück zum Zitat Schwenzer NF, Schmidt H, Claussen CD (2012) Whole-body MR/PET: applications in abdominal imaging. Abdom Imaging 37:20–28PubMedCrossRef Schwenzer NF, Schmidt H, Claussen CD (2012) Whole-body MR/PET: applications in abdominal imaging. Abdom Imaging 37:20–28PubMedCrossRef
3.
Zurück zum Zitat Catana C, Drzezga A, Heiss WD, Rosen BR (2012) PET/MRI for neurologic applications. J Nucl Med 53:1916–1925PubMedCrossRef Catana C, Drzezga A, Heiss WD, Rosen BR (2012) PET/MRI for neurologic applications. J Nucl Med 53:1916–1925PubMedCrossRef
4.
Zurück zum Zitat U.S. Department of Energy TOoBaER (2010) A vital legacy—biological and environmental research in the atomic age. Berkeley: Lawrence Berkeley National Laboratory U.S. Department of Energy TOoBaER (2010) A vital legacy—biological and environmental research in the atomic age. Berkeley: Lawrence Berkeley National Laboratory
5.
Zurück zum Zitat Cho ZH, Chan JK, Eriksson L (1976) Circular ring transverse axial positron camera for 3-dimensional reconstruction of radionuclides distribution. IEEE Trans Nucl Sci 23:613–622CrossRef Cho ZH, Chan JK, Eriksson L (1976) Circular ring transverse axial positron camera for 3-dimensional reconstruction of radionuclides distribution. IEEE Trans Nucl Sci 23:613–622CrossRef
6.
Zurück zum Zitat Carr HY (1953) Free precession techniques in nuclear magnetic resonance. Cambridge: Harvard University Carr HY (1953) Free precession techniques in nuclear magnetic resonance. Cambridge: Harvard University
7.
Zurück zum Zitat Damadian R, Goldsmith M, Minkoff L (1977) NMR in cancer: XVI. FONAR image of the live human body. Physiol Chem Phys 9:97–100, 108 Damadian R, Goldsmith M, Minkoff L (1977) NMR in cancer: XVI. FONAR image of the live human body. Physiol Chem Phys 9:97–100, 108
8.
Zurück zum Zitat Hamamatsu T (2006) Photomultiplier tubes—basics and applications, 3rd edn. Hamamatsy: Hamamatsu photonics K.K. Electron Tube Division Hamamatsu T (2006) Photomultiplier tubes—basics and applications, 3rd edn. Hamamatsy: Hamamatsu photonics K.K. Electron Tube Division
9.
Zurück zum Zitat Spanoudaki VC, McElroy DP, Torres-Espallardo I, Ziegler SI (2008) Effect of temperature on the performance of proportional APD-based modules for gamma ray detection in positron emission tomography. IEEE Trans Nucl Sci 55:469–480CrossRef Spanoudaki VC, McElroy DP, Torres-Espallardo I, Ziegler SI (2008) Effect of temperature on the performance of proportional APD-based modules for gamma ray detection in positron emission tomography. IEEE Trans Nucl Sci 55:469–480CrossRef
10.
Zurück zum Zitat Del Guerra A, Belcari N, Giuseppina Bisogni M, et al. (2010) Advantages and pitfalls of the silicon photomultiplier (SiPM) as photodetector for the next generation of PET scanners. Nucl Instrum Methods Phys Res A 617:223–226CrossRef Del Guerra A, Belcari N, Giuseppina Bisogni M, et al. (2010) Advantages and pitfalls of the silicon photomultiplier (SiPM) as photodetector for the next generation of PET scanners. Nucl Instrum Methods Phys Res A 617:223–226CrossRef
11.
Zurück zum Zitat España S, Fraile LM, Herraiz JL, et al. (2010) Performance evaluation of SiPM photodetectors for PET imaging in the presence of magnetic fields. Nucl Instrum Methods Phys Res A 613:308–316CrossRef España S, Fraile LM, Herraiz JL, et al. (2010) Performance evaluation of SiPM photodetectors for PET imaging in the presence of magnetic fields. Nucl Instrum Methods Phys Res A 613:308–316CrossRef
13.
Zurück zum Zitat Veit-Haibach P, Kuhn FP, Wiesinger F, Delso G, von Schulthess G (2013) PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine. Magn Reson Mater Phys 26:25–35CrossRef Veit-Haibach P, Kuhn FP, Wiesinger F, Delso G, von Schulthess G (2013) PET-MR imaging using a tri-modality PET/CT-MR system with a dedicated shuttle in clinical routine. Magn Reson Mater Phys 26:25–35CrossRef
14.
Zurück zum Zitat Shao Y, Cherry SR, Farahani K, et al. (1997) Development of a PET detector system compatible with MRI/NMR systems. IEEE Trans Nucl Sci 44:1167–1171CrossRef Shao Y, Cherry SR, Farahani K, et al. (1997) Development of a PET detector system compatible with MRI/NMR systems. IEEE Trans Nucl Sci 44:1167–1171CrossRef
15.
Zurück zum Zitat Shao Y, Cherry SR, Farahani K, et al. (1997) Simultaneous PET and MR imaging. Phys Med Biol 42:1965–1970PubMedCrossRef Shao Y, Cherry SR, Farahani K, et al. (1997) Simultaneous PET and MR imaging. Phys Med Biol 42:1965–1970PubMedCrossRef
16.
Zurück zum Zitat Slates RB, Farahani K, Shao Y, et al. (1999) A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner. Phys Med Biol 44:2015–2027PubMedCrossRef Slates RB, Farahani K, Shao Y, et al. (1999) A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner. Phys Med Biol 44:2015–2027PubMedCrossRef
17.
Zurück zum Zitat Carson R, Herscovitch P, Daube-Witherspoon M (1998) Quantitative functional brain imaging with positron emission tomography. San Diego: Academic Press Carson R, Herscovitch P, Daube-Witherspoon M (1998) Quantitative functional brain imaging with positron emission tomography. San Diego: Academic Press
18.
Zurück zum Zitat Raylman RR, Majewski S, Lemieux SK, et al. (2006) Simultaneous MRI and PET imaging of a rat brain. Phys Med Biol 51:6371–6379PubMedCrossRef Raylman RR, Majewski S, Lemieux SK, et al. (2006) Simultaneous MRI and PET imaging of a rat brain. Phys Med Biol 51:6371–6379PubMedCrossRef
19.
Zurück zum Zitat Schlyer D, Vaska P, Tomasi D, et al. (2007) A simultaneous PET/MRI scanner based on RatCAP in small animals. In: IEEE nuclear science symposium conference record, pp 3256–3259 Schlyer D, Vaska P, Tomasi D, et al. (2007) A simultaneous PET/MRI scanner based on RatCAP in small animals. In: IEEE nuclear science symposium conference record, pp 3256–3259
20.
Zurück zum Zitat Ravindranath B, Maramraju SH, Junnarkar SS, et al. (2008) A simultaneous PET/MRI breast scanner based on the RatCAP. In: IEEE nuclear science symposium conference record, pp 4650–4655 Ravindranath B, Maramraju SH, Junnarkar SS, et al. (2008) A simultaneous PET/MRI breast scanner based on the RatCAP. In: IEEE nuclear science symposium conference record, pp 4650–4655
21.
Zurück zum Zitat Catana C, Wu Y, Judenhofer MS, et al. (2006) Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med 47:1968–1976PubMed Catana C, Wu Y, Judenhofer MS, et al. (2006) Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med 47:1968–1976PubMed
22.
Zurück zum Zitat Judenhofer MS, Wehrl HF, Newport DF, et al. (2008) Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med 14:459–465PubMedCrossRef Judenhofer MS, Wehrl HF, Newport DF, et al. (2008) Simultaneous PET-MRI: a new approach for functional and morphological imaging. Nat Med 14:459–465PubMedCrossRef
23.
Zurück zum Zitat Schlemmer H-P, Pichler B, Wienhard K, et al. (2007) Simultaneous MR/PET for brain imaging: first patient scans. J Nucl Med 48:45 Schlemmer H-P, Pichler B, Wienhard K, et al. (2007) Simultaneous MR/PET for brain imaging: first patient scans. J Nucl Med 48:45
24.
Zurück zum Zitat Schlemmer H-PW, Pichler BJ, Schmand M, et al. (2008) Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology 248:1028–1035PubMedCrossRef Schlemmer H-PW, Pichler BJ, Schmand M, et al. (2008) Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology 248:1028–1035PubMedCrossRef
25.
Zurück zum Zitat Delso G, Furst S, Jakoby B, et al. (2011) Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med 52:1914–1922PubMedCrossRef Delso G, Furst S, Jakoby B, et al. (2011) Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med 52:1914–1922PubMedCrossRef
26.
Zurück zum Zitat Levin C, Glover G, Deller T, et al. (2013) Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging. J Nucl Med 54:148 Levin C, Glover G, Deller T, et al. (2013) Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging. J Nucl Med 54:148
27.
Zurück zum Zitat Wagenknecht G, Kaiser HJ, Mottaghy FM, Herzog H (2013) MRI for attenuation correction in PET: methods and challenges. Magn Reson Mater Phys 26:99–113CrossRef Wagenknecht G, Kaiser HJ, Mottaghy FM, Herzog H (2013) MRI for attenuation correction in PET: methods and challenges. Magn Reson Mater Phys 26:99–113CrossRef
28.
Zurück zum Zitat Qian H, Shanbhag D, Kaushik S, et al. (2012) Whole-body PET/MR attenuation correction combining image segmentation, truncation completion and atlas-based skull segmentation. In: PET/MR and SPECT/MR: new paradigms for combined modalities in molecular imaging conference, Elba Qian H, Shanbhag D, Kaushik S, et al. (2012) Whole-body PET/MR attenuation correction combining image segmentation, truncation completion and atlas-based skull segmentation. In: PET/MR and SPECT/MR: new paradigms for combined modalities in molecular imaging conference, Elba
29.
Zurück zum Zitat Nuyts J, Bal G, Kehren F, et al. (2013) Completion of a truncated attenuation image from the attenuated PET emission data. IEEE Trans Med Imaging 32:237–246PubMedCrossRef Nuyts J, Bal G, Kehren F, et al. (2013) Completion of a truncated attenuation image from the attenuated PET emission data. IEEE Trans Med Imaging 32:237–246PubMedCrossRef
30.
Zurück zum Zitat Teuho J, Johansson J, Linden J, Saunavaara V, Tolvanen T, Teras M (2013) Quantitative bias in PET/MR from attenuation correction and reconstruction: a comparison with PET and PET/CT with an anatomical brain phantom and Hoffman brain phantom. In: 2013 IEEE nuclear science symposium and medical imaging conference (NSS/MIC), pp 1–8 Teuho J, Johansson J, Linden J, Saunavaara V, Tolvanen T, Teras M (2013) Quantitative bias in PET/MR from attenuation correction and reconstruction: a comparison with PET and PET/CT with an anatomical brain phantom and Hoffman brain phantom. In: 2013 IEEE nuclear science symposium and medical imaging conference (NSS/MIC), pp 1–8
31.
Zurück zum Zitat Izquierdo-Garcia D, Sawiak S, Knesaurek K, et al. (2014) Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging. Eur J Nucl Med Mol Imaging 41:1574–1584PubMedCentralPubMedCrossRef Izquierdo-Garcia D, Sawiak S, Knesaurek K, et al. (2014) Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging. Eur J Nucl Med Mol Imaging 41:1574–1584PubMedCentralPubMedCrossRef
32.
Zurück zum Zitat Aznar MC, Sersar R, Saabye J, et al. (2014) Whole-body PET/MRI: the effect of bone attenuation during MR-based attenuation correction in oncology imaging. Eur J Radiol 83:1177–1183PubMedCrossRef Aznar MC, Sersar R, Saabye J, et al. (2014) Whole-body PET/MRI: the effect of bone attenuation during MR-based attenuation correction in oncology imaging. Eur J Radiol 83:1177–1183PubMedCrossRef
33.
Zurück zum Zitat Delso G, Carl M, Wiesinger F, et al. (2014) Anatomic evaluation of 3-dimensional ultrashort-echo-time bone maps for PET/MR attenuation correction. J Nucl Med 55:780–785PubMedCrossRef Delso G, Carl M, Wiesinger F, et al. (2014) Anatomic evaluation of 3-dimensional ultrashort-echo-time bone maps for PET/MR attenuation correction. J Nucl Med 55:780–785PubMedCrossRef
34.
Zurück zum Zitat NEMA NU 2-2012 (2012) Performance measurements of positron emission tomographs. Rosslyn: National Electrical Manufacturers Association NEMA NU 2-2012 (2012) Performance measurements of positron emission tomographs. Rosslyn: National Electrical Manufacturers Association
35.
Zurück zum Zitat Boellaard R, O’Doherty MJ, Weber WA, et al. (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37:181–200PubMedCentralPubMedCrossRef Boellaard R, O’Doherty MJ, Weber WA, et al. (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37:181–200PubMedCentralPubMedCrossRef
36.
Zurück zum Zitat Kraus R, Delso G, Ziegler SI (2012) Simulation study of tissue-specific positron range correction for the new biograph mMR whole-body PET/MR system. IEEE Trans Nucl Sci 59:1900–1909CrossRef Kraus R, Delso G, Ziegler SI (2012) Simulation study of tissue-specific positron range correction for the new biograph mMR whole-body PET/MR system. IEEE Trans Nucl Sci 59:1900–1909CrossRef
Metadaten
Titel
How does PET/MR work? Basic physics for physicians
verfasst von
Gaspar Delso
Edwin ter Voert
Patrick Veit-Haibach
Publikationsdatum
01.08.2015
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 6/2015
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-015-0437-5

Weitere Artikel der Ausgabe 6/2015

Abdominal Radiology 6/2015 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.