Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria

verfasst von: Katharina Marten, Florian Auer, Stefan Schmidt, Gerhard Kohl, Ernst J. Rummeny, Christoph Engelke

Erschienen in: European Radiology | Ausgabe 4/2006

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to compare relative values of manual unidimensional measurements (MD) and automated volumetry (AV) for longitudinal treatment response assessment in patients with pulmonary metastases. Fifty consecutive patients with pulmonary metastases and repeat chest multidetector-row CT (median interval=2 months) were independently assessed by two radiologists for treatment response using Response Evaluation Criteria In Solid Tumours (RECIST). Statistics included relative measurement errors (RME), intra-/interobserver correlations, limits of agreement (95% LoA), and kappa. A total of 202 metastases (median volume=182.22 mm3; range=3.16–5,195.13 mm3) were evaluated. RMEs were significantly higher for MD than for AV (intraobserver RME=2.34–3.73% and 0.15–0.22% for MD and AV respectively; P<0.05. Interobserver RME=3.53–3.76% and 0.22–0.29% for MD and AV respectively; P<0.05). Overall correlation was significantly better for AV than for MD (P<0.05). Intraobserver 95% LoAs were −1.85 to 1.75 mm for MD and −11.28 to 9.84 mm3 for AV. The interobserver 95% LoA were −1.46 to 1.92 mm for MD and −11.17 to 9.33 mm3 for AV. There was total intra-/interobserver agreement on response using AV (κ=1). MD intra- and interobserver agreements were 0.73–0.84 and 0.77–0.80 respectively. Of the 200 MD response ratings, 28 (14/50 patients) were discordant. Agreement using MD dropped significantly from total remission to progressive disease (P<0.05). We therefore conclude that AV allows for better reproducibility of response evaluation in pulmonary metastases and should be preferred to MD in these patients.
Literatur
1.
Zurück zum Zitat Miller AB, Hogestraeten B, Staquet M, Winkler A (1981) Reporting results of cancer treatment. Cancer 47:207–214 Miller AB, Hogestraeten B, Staquet M, Winkler A (1981) Reporting results of cancer treatment. Cancer 47:207–214
2.
Zurück zum Zitat Warr D, McKinney S, Tannock I (1984) Influence of measurement error on assessment of response to anticancer chemotherapy: proposal for new criteria of tumour response. J Clin Oncol 2:1040–1046 Warr D, McKinney S, Tannock I (1984) Influence of measurement error on assessment of response to anticancer chemotherapy: proposal for new criteria of tumour response. J Clin Oncol 2:1040–1046
3.
Zurück zum Zitat Therasse P, Arbuck SG, Eisenhauer EA, Wanders J, Kaplan RS et al. (2000) New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst 92:205–216 Therasse P, Arbuck SG, Eisenhauer EA, Wanders J, Kaplan RS et al. (2000) New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst 92:205–216
4.
Zurück zum Zitat Ratain M (2004) Phase II studies of modern drugs directed against new targets: if you are fazed, too, then resist RECIST. J Clin Oncol 22:4442–4444 Ratain M (2004) Phase II studies of modern drugs directed against new targets: if you are fazed, too, then resist RECIST. J Clin Oncol 22:4442–4444
5.
Zurück zum Zitat Revel MP, Bissery A, Bienvenu M, Aycard L, Lefort C, Frija G (2004) Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology 231:453–458 Revel MP, Bissery A, Bienvenu M, Aycard L, Lefort C, Frija G (2004) Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology 231:453–458
6.
Zurück zum Zitat Kostis WJ, Yankelevitz DF, Reeves AP, Fluture SC, Henschke CI (2004) Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 231:446–452 Kostis WJ, Yankelevitz DF, Reeves AP, Fluture SC, Henschke CI (2004) Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 231:446–452
7.
Zurück zum Zitat Wormanns D, Kohl G, Klotz E et al. (2004) Volumetric measurement of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 14:86–92 Wormanns D, Kohl G, Klotz E et al. (2004) Volumetric measurement of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 14:86–92
8.
Zurück zum Zitat Fan L, Qian J, Odry BL et al. (2002) Automatic segmentation of pulmonary nodules by using dynamic cross-correlation for interactive CAD systems. In: Sonka M, Fitzpatrick JM (eds) Medical imaging: image processing. Proc SPIE 4684:1362–1396 Fan L, Qian J, Odry BL et al. (2002) Automatic segmentation of pulmonary nodules by using dynamic cross-correlation for interactive CAD systems. In: Sonka M, Fitzpatrick JM (eds) Medical imaging: image processing. Proc SPIE 4684:1362–1396
9.
Zurück zum Zitat Bland M, Altman DG (1986) Statistical methods for assessing the difference between two methods of measurement. Lancet i:307–310 Bland M, Altman DG (1986) Statistical methods for assessing the difference between two methods of measurement. Lancet i:307–310
10.
Zurück zum Zitat Fleiss JL, Nee CM, Landis JR (1979) Large sample variance of kappa in the case of different sets of raters. Psychol Bull 86:974–977 Fleiss JL, Nee CM, Landis JR (1979) Large sample variance of kappa in the case of different sets of raters. Psychol Bull 86:974–977
11.
Zurück zum Zitat Fleiss JL (1981) Statistical methods for rates and proportions, 2nd edition. Wiley, New York Fleiss JL (1981) Statistical methods for rates and proportions, 2nd edition. Wiley, New York
12.
Zurück zum Zitat Altman DG (1991) Practical statistics for medical research. Chapman and Hall, London Altman DG (1991) Practical statistics for medical research. Chapman and Hall, London
13.
Zurück zum Zitat Thiesse P, Ollivier L, Di Stefano-Louineau D et al. (1997) Response rate accuracy in oncology trials: reasons for interobserver variability. J Clin Oncol 15:3507–3514 Thiesse P, Ollivier L, Di Stefano-Louineau D et al. (1997) Response rate accuracy in oncology trials: reasons for interobserver variability. J Clin Oncol 15:3507–3514
14.
Zurück zum Zitat Gwyther SJ, Aapro MS, Hatty SR, Postmus PE, Smith IE (1999) Results of an independent oncology review board of pivotal clinical trials of gemcitabine in nonsmall cell lung cancer. Anticancer Drugs 10:693–698 Gwyther SJ, Aapro MS, Hatty SR, Postmus PE, Smith IE (1999) Results of an independent oncology review board of pivotal clinical trials of gemcitabine in nonsmall cell lung cancer. Anticancer Drugs 10:693–698
15.
Zurück zum Zitat Biganzoli L, Lohrisch C, Paridaens R, Therasse P, Piccart M (2002) Analysis of two EORTC trials in metastatic breast cancer (MBC) support the recommendation of external response review (ERR) in trials with response rate (RR) as primary endpoint. Eur J Cancer 36(Suppl 5):S90 Biganzoli L, Lohrisch C, Paridaens R, Therasse P, Piccart M (2002) Analysis of two EORTC trials in metastatic breast cancer (MBC) support the recommendation of external response review (ERR) in trials with response rate (RR) as primary endpoint. Eur J Cancer 36(Suppl 5):S90
16.
Zurück zum Zitat Marten K, Grillhösl A, Seyfarth T, Obenauer S, Rummeny EJ, Engelke C (2005) Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings. Eur Radiol 15:203–212 Marten K, Grillhösl A, Seyfarth T, Obenauer S, Rummeny EJ, Engelke C (2005) Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings. Eur Radiol 15:203–212
17.
Zurück zum Zitat Marten K, Seyfarth T, Auer F, Wiener E, Grillhösl A, Obenauer S, Rummeny EJ, Engelke C (2004) Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists. Eur Radiol 14:1930–1938 Marten K, Seyfarth T, Auer F, Wiener E, Grillhösl A, Obenauer S, Rummeny EJ, Engelke C (2004) Computer-assisted detection of pulmonary nodules: performance evaluation of an expert knowledge-based detection system in consensus reading with experienced and inexperienced chest radiologists. Eur Radiol 14:1930–1938
18.
Zurück zum Zitat Sohaib SA, Turner B, Hanson JA, Farquharson M, Oliver RTD, Reznek RH (2000) CT assessment of tumour response to treatment: comparison of linear, cross-sectional and volumetric measures of tumour size. Brit J Radiol 73:1178–1184 Sohaib SA, Turner B, Hanson JA, Farquharson M, Oliver RTD, Reznek RH (2000) CT assessment of tumour response to treatment: comparison of linear, cross-sectional and volumetric measures of tumour size. Brit J Radiol 73:1178–1184
19.
Zurück zum Zitat Prasad SR, Jhaveri KS, Saini S, Hahn PF, Halpern EF, Sumner JE (2002) CT tumour measurement for therapeutic response assessment: comparison of unidimensional, bidimensional and volumetric techniques—initial observations. Radiology 225:416–419 Prasad SR, Jhaveri KS, Saini S, Hahn PF, Halpern EF, Sumner JE (2002) CT tumour measurement for therapeutic response assessment: comparison of unidimensional, bidimensional and volumetric techniques—initial observations. Radiology 225:416–419
20.
Zurück zum Zitat Yankelevitz DF, Gupta R, Zhao B, Henschke CI (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256 Yankelevitz DF, Gupta R, Zhao B, Henschke CI (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256
21.
Zurück zum Zitat Erasmus JJ, Gladish GW, Broemeling L, Sabloff BS, Truong MT, Herbst RS, Munden RF (2003) Interobserver and intraobserver variability in measurement of nonsmall-cell carcinoma of the lung lesions: implications for assessment of tumour response. J Clin Oncol 21:2574–2582 Erasmus JJ, Gladish GW, Broemeling L, Sabloff BS, Truong MT, Herbst RS, Munden RF (2003) Interobserver and intraobserver variability in measurement of nonsmall-cell carcinoma of the lung lesions: implications for assessment of tumour response. J Clin Oncol 21:2574–2582
22.
Zurück zum Zitat Schwartz M (1961) A biomathematical approach to clinical tumour growth. Cancer 14:1272–1294 Schwartz M (1961) A biomathematical approach to clinical tumour growth. Cancer 14:1272–1294
23.
Zurück zum Zitat Tran LN, Brown MS, Goldin JG et al. (2004) Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography. Acad Radiol 11:1355–1360 Tran LN, Brown MS, Goldin JG et al. (2004) Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography. Acad Radiol 11:1355–1360
24.
Zurück zum Zitat Werner-Wasik M, Xiao Y, Pequignot E, Curran WJ, Hauck W (2001) Assessment of lung cancer response after nonoperative therapy: tumour diameter, bidimensional product, and volume. A serial CT scan-based study. Int J Radiat Oncol Biol Phys 51:56–61 Werner-Wasik M, Xiao Y, Pequignot E, Curran WJ, Hauck W (2001) Assessment of lung cancer response after nonoperative therapy: tumour diameter, bidimensional product, and volume. A serial CT scan-based study. Int J Radiat Oncol Biol Phys 51:56–61
Metadaten
Titel
Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
verfasst von
Katharina Marten
Florian Auer
Stefan Schmidt
Gerhard Kohl
Ernst J. Rummeny
Christoph Engelke
Publikationsdatum
01.04.2006
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2006
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0036-x

Weitere Artikel der Ausgabe 4/2006

European Radiology 4/2006 Zur Ausgabe

Book Reviews

Recent literature

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.