Skip to main content
Erschienen in: European Radiology 6/2005

01.06.2005 | Experimental

Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model

verfasst von: Ji Hoon Shin, Ho-Young Song, Tae-Seok Seo, Soon Hong Yuk, Young-Hwa Kim, Yong-Mee Cho, Gi Bok Choi, Tae-Hyung Kim, Ji-Yeon Suh

Erschienen in: European Radiology | Ausgabe 6/2005

Einloggen, um Zugang zu erhalten

Abstract

This study was designed to evaluate the feasibility and efficacy of a dexamethasone (DXM)-eluting, covered, self-expanding metallic stent to reduce tissue reaction following stent placement in a canine bronchial model. We placed a DXM-eluting, polyurethane-covered, self-expanding metallic stent (drug stent, DS) and a polyurethane-covered, self-expanding metallic stent (control stent, CS) alternately in each left main bronchus and left lower lobe bronchus in 12 dogs. The stents were 20 mm in diameter and length when fully expanded. The dose of DXM was approximately 36.7 mg in each DS, but was absent in the CS. The dogs were euthanased 1 week (n=4), 2 weeks (n=4) or 4 weeks (n=4) after stent placement. Histologic findings, such as epithelial erosion/ulcer or granulation tissue thickness, were obtained from the mid-portion of the bronchus, where the stent had been placed, and evaluated between DS and CS. There were no procedure-related complications or malpositioning of any of the bronchial stents. Stent migration was detected in one dog just before euthanasia 1 week following stent placement. Stent patency was maintained until euthanasia in all dogs. Epithelial erosion/ulcer (%) was significantly less in the DS (mean±standard deviation, 46.88±23.75) than in the CS (73.75±14.08) (P=0.026) for all time-points. There was a decrease in epithelial erosion/ulcer as the follow-up period increased in both DS and CS. The granulation tissue thickness (mm) was less in DS (2.63±2.05) than in CS (3.49±2.95), although the difference was not significant (P=0.751) for all time-points. There was a tendency toward an increase in granulation tissue thickness and chronic lymphocytic infiltration as the follow-up period increased in both DS and CS. In conclusion, DXM-eluting, covered, self-expanding metallic stent seems to be effective in reducing tissue reaction secondary to stent placement in a canine bronchial model.
Literatur
1.
Zurück zum Zitat Miyazawa T, Yamakido M, Ikeda S et al (2000) Implantation of ultraflex nitinol stents in malignant tracheobronchial stenoses. Chest 118:959–965CrossRefPubMed Miyazawa T, Yamakido M, Ikeda S et al (2000) Implantation of ultraflex nitinol stents in malignant tracheobronchial stenoses. Chest 118:959–965CrossRefPubMed
2.
Zurück zum Zitat Shin JH, Kim SW, Shin TS et al (2003) Malignant tracheobronchial strictures: palliation with covered retrievable expandable nitinol stents. J Vasc Interv Radiol 14:1525–1534PubMed Shin JH, Kim SW, Shin TS et al (2003) Malignant tracheobronchial strictures: palliation with covered retrievable expandable nitinol stents. J Vasc Interv Radiol 14:1525–1534PubMed
3.
Zurück zum Zitat Monnier P, Mudry A, Stanzel F et al (1996) The use of the covered Wallstent for the palliative treatment of inoperable tracheobronchial cancers. A prospective, multicenter study. Chest 110:1161–1168PubMed Monnier P, Mudry A, Stanzel F et al (1996) The use of the covered Wallstent for the palliative treatment of inoperable tracheobronchial cancers. A prospective, multicenter study. Chest 110:1161–1168PubMed
4.
Zurück zum Zitat George PJ, Irving JD, Khaghani A, Dick R (1992) Role of the Gianturco expandable metal stent in the management of tracheobronchial obstruction. Cardiovasc Interv Radiol 15:375–381 George PJ, Irving JD, Khaghani A, Dick R (1992) Role of the Gianturco expandable metal stent in the management of tracheobronchial obstruction. Cardiovasc Interv Radiol 15:375–381
5.
Zurück zum Zitat Song HY, Shim TS, Kang SG et al (1999) Tracheobronchial strictures: treatment with a polyurethane-covered retrievable expandable nitinol stent—initial experience. Radiology 213:905—912PubMed Song HY, Shim TS, Kang SG et al (1999) Tracheobronchial strictures: treatment with a polyurethane-covered retrievable expandable nitinol stent—initial experience. Radiology 213:905—912PubMed
6.
Zurück zum Zitat Madden BP, Datta S, Charokopos N (2002) Experience with Ultraflex expandable metallic stents in the management of endobronchial pathology. Ann Thorac Surg 73:938–944CrossRefPubMed Madden BP, Datta S, Charokopos N (2002) Experience with Ultraflex expandable metallic stents in the management of endobronchial pathology. Ann Thorac Surg 73:938–944CrossRefPubMed
7.
Zurück zum Zitat Zakaluzny SA, Lane JD, Mair EA (2003) Complications of tracheobronchial airway stents. Otolaryngol Head Neck Surg 128:478–488CrossRef Zakaluzny SA, Lane JD, Mair EA (2003) Complications of tracheobronchial airway stents. Otolaryngol Head Neck Surg 128:478–488CrossRef
8.
Zurück zum Zitat Filler RM, Forte V, Chait P (1998) Tracheobronchial stenting for the treatment of airway obstruction. J Pediatr Surg 33:304–311CrossRefPubMed Filler RM, Forte V, Chait P (1998) Tracheobronchial stenting for the treatment of airway obstruction. J Pediatr Surg 33:304–311CrossRefPubMed
9.
Zurück zum Zitat Holmes DR Jr, Leon MB, Moses JW et al (2004) Analysis of 1-year clinical outcomes in the SIRIUS trial: a randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis. Circulation 109:634–640 Holmes DR Jr, Leon MB, Moses JW et al (2004) Analysis of 1-year clinical outcomes in the SIRIUS trial: a randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis. Circulation 109:634–640
10.
Zurück zum Zitat Park SJ, Shim WH, Ho DS et al (2003) A paclitaxel-eluting stent for the prevention of coronary restenosis. N Engl J Med 348:1537–1545CrossRefPubMed Park SJ, Shim WH, Ho DS et al (2003) A paclitaxel-eluting stent for the prevention of coronary restenosis. N Engl J Med 348:1537–1545CrossRefPubMed
11.
Zurück zum Zitat Lincoff AM, Furst JG, Ellis SG, Tuch RJ, Topol EJ (1997) Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model. J Am Coll Cardiol 29:808–816CrossRef Lincoff AM, Furst JG, Ellis SG, Tuch RJ, Topol EJ (1997) Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model. J Am Coll Cardiol 29:808–816CrossRef
12.
Zurück zum Zitat Strecker EP, Gabelmann A, Boos I et al (1998) Effect on intimal hyperplasia of dexamethasone released from coated metal stents compared with non-coated stents in canine femoral arteries. Cardiovasc Interv Radiol 21:487–496CrossRef Strecker EP, Gabelmann A, Boos I et al (1998) Effect on intimal hyperplasia of dexamethasone released from coated metal stents compared with non-coated stents in canine femoral arteries. Cardiovasc Interv Radiol 21:487–496CrossRef
13.
Zurück zum Zitat Colburn MD, Moore WS, Gelabert HA, Quinones-Baldrich WJ (1992) Dose responsive suppression of myointimal hyperplasia by dexamethasone. J Vasc Surg. 15:510–518CrossRef Colburn MD, Moore WS, Gelabert HA, Quinones-Baldrich WJ (1992) Dose responsive suppression of myointimal hyperplasia by dexamethasone. J Vasc Surg. 15:510–518CrossRef
14.
Zurück zum Zitat Van Put DJ, Van Hove CE, De Meyer GR, Wuyts F, Herman AG, Bult H (1995) Dexamethasone influences intimal thickening and vascular reactivity in the rabbit collared carotid artery. Eur J Pharmacol 294:753–761CrossRef Van Put DJ, Van Hove CE, De Meyer GR, Wuyts F, Herman AG, Bult H (1995) Dexamethasone influences intimal thickening and vascular reactivity in the rabbit collared carotid artery. Eur J Pharmacol 294:753–761CrossRef
15.
Zurück zum Zitat Chervu A, Moore WS, Quinones-Baldrich WJ, Henderson T (1989) Efficacy of corticosteroids in suppression of intimal hyperplasia. J Vasc Surg. 10:129–134CrossRef Chervu A, Moore WS, Quinones-Baldrich WJ, Henderson T (1989) Efficacy of corticosteroids in suppression of intimal hyperplasia. J Vasc Surg. 10:129–134CrossRef
16.
Zurück zum Zitat Yoon HK, Park KS, Kang SG et al (2001) Influence of dexamethasone-coated nitinol stent on neointimal formation in the canine great vessel model. Korean J Radiol 44:433–440 Yoon HK, Park KS, Kang SG et al (2001) Influence of dexamethasone-coated nitinol stent on neointimal formation in the canine great vessel model. Korean J Radiol 44:433–440
17.
Zurück zum Zitat Hwang JC, Song HY, Kang SG et al (2001) Covered retrievable tracheobronchial hinged stent: an experimental study in dogs. J Vasc Interv Radiol. 12:1429–1436 Hwang JC, Song HY, Kang SG et al (2001) Covered retrievable tracheobronchial hinged stent: an experimental study in dogs. J Vasc Interv Radiol. 12:1429–1436
18.
Zurück zum Zitat Coppit G, Perkins J, Munaretto J, Nielsen R, McKinney L, Ulnick K (2000) The effects of mitomycin-C and stenting on airway wound healing after laryngotracheal reconstruction in a pig model. Int J Pediatr Otorhinolaryngol. 53:125–135CrossRef Coppit G, Perkins J, Munaretto J, Nielsen R, McKinney L, Ulnick K (2000) The effects of mitomycin-C and stenting on airway wound healing after laryngotracheal reconstruction in a pig model. Int J Pediatr Otorhinolaryngol. 53:125–135CrossRef
19.
Zurück zum Zitat Guzman LA, Labhasetwar V, Song C et al (1996) Local intraluminal infusion of biodegradable polymeric nanoparticles. A novel approach for prolonged drug delivery after balloon angioplasty. Circulation 94:1441–1448 Guzman LA, Labhasetwar V, Song C et al (1996) Local intraluminal infusion of biodegradable polymeric nanoparticles. A novel approach for prolonged drug delivery after balloon angioplasty. Circulation 94:1441–1448
20.
Zurück zum Zitat Mayoral W, Fleischer D, Salcedo J, Roy P, Al-Kawas F, Benjamin S (2000) Nonmalignant obstruction is a common problem with metal stents in the treatment of esophageal cancer. Gastrointest Endosc 51:556–559CrossRef Mayoral W, Fleischer D, Salcedo J, Roy P, Al-Kawas F, Benjamin S (2000) Nonmalignant obstruction is a common problem with metal stents in the treatment of esophageal cancer. Gastrointest Endosc 51:556–559CrossRef
21.
Zurück zum Zitat Kurkinen M, Vaheri A, Roberts PJ, Stenman S (1980) Sequential appearance of fibronectin and collagen in experimental granulation tissue. Lab Invest 43:47–51 Kurkinen M, Vaheri A, Roberts PJ, Stenman S (1980) Sequential appearance of fibronectin and collagen in experimental granulation tissue. Lab Invest 43:47–51
22.
Zurück zum Zitat Blyth DI, Wharton TF, Pedrick MS, Savage TJ, Sanjar S (2000) Airway subepithelial fibrosis in a murine model of atopic asthma: suppression by dexamethasone or anti-interleukin-5 antibody. Am J Respir Cell Mol Biol. 23:241–246 Blyth DI, Wharton TF, Pedrick MS, Savage TJ, Sanjar S (2000) Airway subepithelial fibrosis in a murine model of atopic asthma: suppression by dexamethasone or anti-interleukin-5 antibody. Am J Respir Cell Mol Biol. 23:241–246
23.
Zurück zum Zitat Dixon ER, Weinberg JA, Lew DB (1999) Effect of dexamethasone on bovine airway smooth muscle cell proliferation. J Asthma 36:519–525 Dixon ER, Weinberg JA, Lew DB (1999) Effect of dexamethasone on bovine airway smooth muscle cell proliferation. J Asthma 36:519–525
24.
Zurück zum Zitat Rechavia E, Litvack F, Fishbien MC, Nakamura M, Eigler N (1998) Biocompatibility of polyurethane-coated stents: tissue and vascular aspects. Catheter Cardiovasc Diagn 45:202–207CrossRef Rechavia E, Litvack F, Fishbien MC, Nakamura M, Eigler N (1998) Biocompatibility of polyurethane-coated stents: tissue and vascular aspects. Catheter Cardiovasc Diagn 45:202–207CrossRef
25.
Zurück zum Zitat Ward WK, Slobodzian EP, Tiekotter KL, Wood MD (2002) The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants. Biomaterials 23:4185–4192CrossRef Ward WK, Slobodzian EP, Tiekotter KL, Wood MD (2002) The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants. Biomaterials 23:4185–4192CrossRef
26.
Zurück zum Zitat De Scheerder IK, Wilczek KL, Verbeken EV et al (1995) Biocompatibility of biodegradable and nonbiodegradable polymer-coated stents implanted in porcine peripheral arteries. Cardiovasc Interv Radiol 18:227–232 De Scheerder IK, Wilczek KL, Verbeken EV et al (1995) Biocompatibility of biodegradable and nonbiodegradable polymer-coated stents implanted in porcine peripheral arteries. Cardiovasc Interv Radiol 18:227–232
27.
Zurück zum Zitat De Scheerder IK, Wilczek KL, Verbeken EV et al (1995) Biocompatibility of polymer-coated oversized metallic stents implanted in normal porcine coronary arteries. Atherosclerosis 114:105–114CrossRef De Scheerder IK, Wilczek KL, Verbeken EV et al (1995) Biocompatibility of polymer-coated oversized metallic stents implanted in normal porcine coronary arteries. Atherosclerosis 114:105–114CrossRef
Metadaten
Titel
Influence of a dexamethasone-eluting covered stent on tissue reaction: an experimental study in a canine bronchial model
verfasst von
Ji Hoon Shin
Ho-Young Song
Tae-Seok Seo
Soon Hong Yuk
Young-Hwa Kim
Yong-Mee Cho
Gi Bok Choi
Tae-Hyung Kim
Ji-Yeon Suh
Publikationsdatum
01.06.2005
Erschienen in
European Radiology / Ausgabe 6/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2564-1

Weitere Artikel der Ausgabe 6/2005

European Radiology 6/2005 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.