The double intramedullary cortical button fixation for distal biceps tendon repair

verfasst von: Sebastian Siebenlist, Florian Elser, Gunther H. Sandmann, Arne Buchholz, Frank Martetschläger, Ulrich Stöckle, Andreas Lenich

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 11/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study was designed to present the novel technique of intramedullary cortical button fixation for distal biceps tendon repair via a single-limited anterior portal.

Methods

To reattach the ruptured biceps tendon at the radial tuberosity, two Bicepsbutton (Arthrex, Naples, FL, USA) were intramedullary positioned to the anterior cortex. The surgical procedure is described in detail. This technique has been performed in a first series of 3 patients with acute distal biceps tendon ruptures.

Results

All patients were very satisfied after surgery and would undergo the same surgical procedure again. All patients regained full range of elbow motion with comparable strength of forearm supination and elbow flexion measured against the uninjured arm at 6 months of follow-up. No neurovascular complications have been occured.

Conclusion

Double intramedullary cortical button repair has shown to be a safe and reliable fixation method for distal biceps tendon rupture in a small series of patients. Preliminary results are encouraging.

Level of evidence

Technical description, case series, Level IV.
Literatur
1.
Zurück zum Zitat Agrawal V, Stinson MJ (2005) Case report: heterotopic ossification after repair of distal biceps tendon rupture utilizing a single-incision Endobutton technique. J Shoulder Elbow Surg 14:107–109PubMedCrossRef Agrawal V, Stinson MJ (2005) Case report: heterotopic ossification after repair of distal biceps tendon rupture utilizing a single-incision Endobutton technique. J Shoulder Elbow Surg 14:107–109PubMedCrossRef
2.
Zurück zum Zitat Athwal GS, Steinmann SP, Rispoli DM (2007) The distal biceps tendon: footprint and relevant clinical anatomy. J Hand Surg Am 32:1225–1229PubMedCrossRef Athwal GS, Steinmann SP, Rispoli DM (2007) The distal biceps tendon: footprint and relevant clinical anatomy. J Hand Surg Am 32:1225–1229PubMedCrossRef
3.
Zurück zum Zitat Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using the Endobutton. J Shoulder Elbow Surg 9:120–126PubMedCrossRef Bain GI, Prem H, Heptinstall RJ, Verhellen R, Paix D (2000) Repair of distal biceps tendon rupture: a new technique using the Endobutton. J Shoulder Elbow Surg 9:120–126PubMedCrossRef
4.
Zurück zum Zitat Baker BE, Bierwagen D (1985) Rupture of the distal biceps brachii. Operative versus non- operative treatment. J Bone Joint Surg Am 67:414–417PubMed Baker BE, Bierwagen D (1985) Rupture of the distal biceps brachii. Operative versus non- operative treatment. J Bone Joint Surg Am 67:414–417PubMed
5.
Zurück zum Zitat Cohen MS (2008) Complications of distal biceps tendon repairs. Sports Med Arthrosc 16:148–153PubMedCrossRef Cohen MS (2008) Complications of distal biceps tendon repairs. Sports Med Arthrosc 16:148–153PubMedCrossRef
6.
Zurück zum Zitat Eames MH, Bain GI, Fogg QA, van Riet RP (2007) Distal biceps tendon anatomy: a cadaveric study. J Bone Joint Surg Am 89:1044–1049PubMedCrossRef Eames MH, Bain GI, Fogg QA, van Riet RP (2007) Distal biceps tendon anatomy: a cadaveric study. J Bone Joint Surg Am 89:1044–1049PubMedCrossRef
7.
Zurück zum Zitat Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12:484–490PubMedCrossRef Greenberg JA, Fernandez JJ, Wang T, Turner C (2003) EndoButton-assisted repair of distal biceps tendon ruptures. J Shoulder Elbow Surg 12:484–490PubMedCrossRef
8.
Zurück zum Zitat Heinzelmann AD, Savoie FH 3rd, Ramsey JR, Field LD, Mazzocca AD (2009) A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw. Am J Sports Med 37:989–994PubMedCrossRef Heinzelmann AD, Savoie FH 3rd, Ramsey JR, Field LD, Mazzocca AD (2009) A combined technique for distal biceps repair using a soft tissue button and biotenodesis interference screw. Am J Sports Med 37:989–994PubMedCrossRef
9.
Zurück zum Zitat Hetsroni I, Pilz-Burstein R, Nyska M et al (2008) Avulsion of the distal biceps brachii tendon in middle-aged population: is surgical repair advisable? A comparative study of 22 patients treated with either nonoperative management or early anatomical repair. Injury 39:753–760PubMedCrossRef Hetsroni I, Pilz-Burstein R, Nyska M et al (2008) Avulsion of the distal biceps brachii tendon in middle-aged population: is surgical repair advisable? A comparative study of 22 patients treated with either nonoperative management or early anatomical repair. Injury 39:753–760PubMedCrossRef
10.
Zurück zum Zitat Hutchinson HL, Gloystein D, Gillespie M (2008) Distal biceps tendon insertion: an anatomic study. J Shoulder Elbow Surg 17:342–346PubMedCrossRef Hutchinson HL, Gloystein D, Gillespie M (2008) Distal biceps tendon insertion: an anatomic study. J Shoulder Elbow Surg 17:342–346PubMedCrossRef
11.
Zurück zum Zitat John CK, Field LD, Weiss KS, Savoie FH 3rd (2007) Single-incision repair of acute distal biceps ruptures by use of suture anchors. J Shoulder Elbow Surg 16:78–83PubMedCrossRef John CK, Field LD, Weiss KS, Savoie FH 3rd (2007) Single-incision repair of acute distal biceps ruptures by use of suture anchors. J Shoulder Elbow Surg 16:78–83PubMedCrossRef
12.
Zurück zum Zitat Kahn W, Agarwal M, Funk L (2004) Repair of distal biceps tendon rupture with the Biotenodesis screw. Arch Orthop Trauma Surg 124:206–208CrossRef Kahn W, Agarwal M, Funk L (2004) Repair of distal biceps tendon rupture with the Biotenodesis screw. Arch Orthop Trauma Surg 124:206–208CrossRef
13.
Zurück zum Zitat Kulshreshtha R, Singh R, Sinha J, Hall S (2007) Anatomy of the distal biceps brachii tendon and ist clinical relevance. Clin Orthop Relat Res 456:117–120PubMedCrossRef Kulshreshtha R, Singh R, Sinha J, Hall S (2007) Anatomy of the distal biceps brachii tendon and ist clinical relevance. Clin Orthop Relat Res 456:117–120PubMedCrossRef
14.
Zurück zum Zitat Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adam D (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258PubMedCrossRef Mazzocca AD, Burton KJ, Romeo AA, Santangelo S, Adam D (2007) Biomechanical evaluation of 4 techniques of distal biceps brachii tendon repair. Am J Sports Med 35:252–258PubMedCrossRef
15.
Zurück zum Zitat Mazzocca AD, Cohen M, Berkson E et al (2007) The anatomy of the bicipital tuberosity and distal biceps tendon. J Shoulder Elbow Surg 16:122–127PubMedCrossRef Mazzocca AD, Cohen M, Berkson E et al (2007) The anatomy of the bicipital tuberosity and distal biceps tendon. J Shoulder Elbow Surg 16:122–127PubMedCrossRef
16.
Zurück zum Zitat Mazurek MT, Shin AY (2001) Upper extremity peripheral nerve anatomy: current concepts and applications. Clin Orthop Relat Res 383:7–20PubMedCrossRef Mazurek MT, Shin AY (2001) Upper extremity peripheral nerve anatomy: current concepts and applications. Clin Orthop Relat Res 383:7–20PubMedCrossRef
17.
Zurück zum Zitat McKee MD, Hirji R, Schemitsch EH, Wild LM, Waddell JP (2005) Patient-oriented functional outcome after repair of distal biceps tendon ruptures using a single-incision technique. J Shoulder Elbow Surg 14:302–306PubMedCrossRef McKee MD, Hirji R, Schemitsch EH, Wild LM, Waddell JP (2005) Patient-oriented functional outcome after repair of distal biceps tendon ruptures using a single-incision technique. J Shoulder Elbow Surg 14:302–306PubMedCrossRef
18.
Zurück zum Zitat Miyamoto RG, Elser F, Millett PJ (2010) Distal biceps tendon injuries. J Bone Joint Surg Am 92:2128–2138PubMedCrossRef Miyamoto RG, Elser F, Millett PJ (2010) Distal biceps tendon injuries. J Bone Joint Surg Am 92:2128–2138PubMedCrossRef
19.
Zurück zum Zitat Morrey BF, Askew LJ, An KN, Dobyns JH (1985) Rupture of the distal biceps tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 67:418–421PubMed Morrey BF, Askew LJ, An KN, Dobyns JH (1985) Rupture of the distal biceps tendon of the biceps brachii. A biomechanical study. J Bone Joint Surg Am 67:418–421PubMed
20.
Zurück zum Zitat O′Driscoll SW, Goncalves LB, Dietz P (2007) The hook test for distal biceps tendon avulsion. Am J Sports Med 35:1865–1869PubMedCrossRef O′Driscoll SW, Goncalves LB, Dietz P (2007) The hook test for distal biceps tendon avulsion. Am J Sports Med 35:1865–1869PubMedCrossRef
21.
Zurück zum Zitat Peeters T, Soon C, Jansen N et al (2009) Functional outcome after repair of distal biceps tendon ruptures using the Endobutton technique. J Shoulder Elbow Surg 18:283–287PubMedCrossRef Peeters T, Soon C, Jansen N et al (2009) Functional outcome after repair of distal biceps tendon ruptures using the Endobutton technique. J Shoulder Elbow Surg 18:283–287PubMedCrossRef
22.
Zurück zum Zitat Safran MR, Graham SM (2004) Distal biceps tendon ruptures: incidence, demographics, and the effect of smoking. Clin Orthop Relat Res 404:275–283CrossRef Safran MR, Graham SM (2004) Distal biceps tendon ruptures: incidence, demographics, and the effect of smoking. Clin Orthop Relat Res 404:275–283CrossRef
23.
Zurück zum Zitat Saldua N, Carney J, Dewing C, Thompson M (2008) The effect of drilling angle on posterior interosseous nerve safety during open and endoscopic anterior single-incision repair of the distal biceps tendon. Arthroscopy 24:305–310PubMedCrossRef Saldua N, Carney J, Dewing C, Thompson M (2008) The effect of drilling angle on posterior interosseous nerve safety during open and endoscopic anterior single-incision repair of the distal biceps tendon. Arthroscopy 24:305–310PubMedCrossRef
24.
Zurück zum Zitat Standring S (2008) In: Gray’s Anatomy, 40th Ed. London: Churchill Livingstone. pp 825–826 Standring S (2008) In: Gray’s Anatomy, 40th Ed. London: Churchill Livingstone. pp 825–826
25.
Zurück zum Zitat Siebenlist S, Lenich A, Buchholz A et al. (2011) Biomechanical in vitro validation of intramedullary cortical button fixation for distal biceps tendon repair–a new technique. Am J Sports Med. PMID: 21444761 Siebenlist S, Lenich A, Buchholz A et al. (2011) Biomechanical in vitro validation of intramedullary cortical button fixation for distal biceps tendon repair–a new technique. Am J Sports Med. PMID: 21444761
26.
Zurück zum Zitat Young C, Hudson A, Richards R (1990) Operative treatment of palsy of the posterior interosseous nerve of the forearm. J Bone Joint Surg Am 72:1215–1219PubMed Young C, Hudson A, Richards R (1990) Operative treatment of palsy of the posterior interosseous nerve of the forearm. J Bone Joint Surg Am 72:1215–1219PubMed
Metadaten
Titel
The double intramedullary cortical button fixation for distal biceps tendon repair
verfasst von
Sebastian Siebenlist
Florian Elser
Gunther H. Sandmann
Arne Buchholz
Frank Martetschläger
Ulrich Stöckle
Andreas Lenich
Publikationsdatum
01.11.2011
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2011
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1569-y

Weitere Artikel der Ausgabe 11/2011

Knee Surgery, Sports Traumatology, Arthroscopy 11/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.