Abstract

Purpose

The aim of this study was (1) to survey the orthopaedic companies about the volume of patient-specific instruments (PSI) used in Europe and worldwide; (2) to survey a group of knee arthroplasty surgeons on their acceptance of PSI and finally; (3) to survey a medico-legal expert on PSI-related issues.

Methods

Seven orthopaedic implant manufacturers were contacted to obtain their sales figures (in volume) of PSI in Europe and worldwide for the 2011 and 2012 period. During the Open Meeting of the Belgian Knee Society, a survey by a direct voting system was submitted to a selection of knee surgeons. Finally, a number of medico-legal ‘PSI-related’ questions were submitted to an adult reconstruction surgeon/legal expert.

Results

The total volume, for all contacted companies, of PSI in Europe for 2012 was 17,515 total knee arthroplasty (TKA) and 82,556 TKA worldwide. Biomet (Warsaw, USA) was the number one in volume, both in Europe as worldwide with their Signature system. Biomet represented 27 % of the market share in PSI worldwide. Stryker preferred not to reply to the survey because of the FDA class 1 recall on ShapeMatch cutting guides. Eighty per cent of the Belgian knee surgeons expressed a great interest in PSI and especially, for 58 % of them, if it would increase their surgical accuracy. They valued it even more in unicompartmental arthroplasty, and 55 % was ready to use single-use instruments. Surprisingly, 47 % of surgeons thought it was the company’s responsibility if something goes wrong with a PSI-assisted case. The medico-legal expert concluded that PSI is a complex process that exposes surgeons to new risks in case of failure and stated that companies should not produce surgical guides without validation of the planning by the surgeon.

Conclusion

Patient-specific instruments is of great interest if it can proof to increase the surgical accuracy in knee arthroplasty to the level surgeons are expecting and if in the same time it would make the surgical process more efficient.

Level of evidence

V.
Literatur
1.
Zurück zum Zitat Arnout N, Victor J, Cleppe H, Soenen M, Van Damme G, Bellemans J (2009) Avoidance of patellar eversion improves range of motion after total knee replacement: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc 17:1206–1210PubMedCrossRef Arnout N, Victor J, Cleppe H, Soenen M, Van Damme G, Bellemans J (2009) Avoidance of patellar eversion improves range of motion after total knee replacement: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc 17:1206–1210PubMedCrossRef
2.
Zurück zum Zitat Badlani N, Boden S, Philips F (2012) Orthopedic speciality hospitals: centers of excellence or greed machines? Orthopedics 35:e420–e425PubMed Badlani N, Boden S, Philips F (2012) Orthopedic speciality hospitals: centers of excellence or greed machines? Orthopedics 35:e420–e425PubMed
3.
Zurück zum Zitat Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27:1149–1154PubMedCrossRef Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27:1149–1154PubMedCrossRef
4.
Zurück zum Zitat Barrack RL, Ruh EL, Williams BM, Ford AD, Foreman K, Nunley RM (2012) Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br 94:95–99PubMed Barrack RL, Ruh EL, Williams BM, Ford AD, Foreman K, Nunley RM (2012) Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br 94:95–99PubMed
5.
Zurück zum Zitat Boonen B, Schotanus MG, Kort NP (2012) Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthop 83:387–393PubMedCrossRef Boonen B, Schotanus MG, Kort NP (2012) Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthop 83:387–393PubMedCrossRef
6.
Zurück zum Zitat Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomized controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95:354–359PubMedCrossRef Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomized controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95:354–359PubMedCrossRef
7.
Zurück zum Zitat Chatellard R, Sauleau V, Colmar M, Robert H, Raynaud G, Brilhault J (2013) Medial unicompartmental knee arthroplasty: does tibial component position influence clinical outcomes and arthroplasty survival? Orthop Traumatol Surg Res 99:219–225CrossRef Chatellard R, Sauleau V, Colmar M, Robert H, Raynaud G, Brilhault J (2013) Medial unicompartmental knee arthroplasty: does tibial component position influence clinical outcomes and arthroplasty survival? Orthop Traumatol Surg Res 99:219–225CrossRef
8.
Zurück zum Zitat Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2012) Are MRI-based, patient matched cutting jigs as accurate as the tibial guides? Int Orthop 36:1589–1593PubMedCrossRef Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2012) Are MRI-based, patient matched cutting jigs as accurate as the tibial guides? Int Orthop 36:1589–1593PubMedCrossRef
9.
Zurück zum Zitat Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2012) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-012-2098-z Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2012) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-012-2098-z
10.
Zurück zum Zitat Daniilidis K, Tibesku CO (2013) Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Int Orthop 37:45–50PubMedCrossRef Daniilidis K, Tibesku CO (2013) Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Int Orthop 37:45–50PubMedCrossRef
11.
Zurück zum Zitat Duffy GP (2011) Maximizing surgeon and hospital total knee arthroplasty volume using customized patient instrumentation and swing operating rooms. Am J Orthop (Belle Mead NJ) 40:13–16 Duffy GP (2011) Maximizing surgeon and hospital total knee arthroplasty volume using customized patient instrumentation and swing operating rooms. Am J Orthop (Belle Mead NJ) 40:13–16
12.
Zurück zum Zitat Fitz W (2009) Unicompartmental knee arthroplasty with use of novel patient-specific resurfacing implants and personalized jigs. J Bone Joint Surg Am 91:69–76PubMedCrossRef Fitz W (2009) Unicompartmental knee arthroplasty with use of novel patient-specific resurfacing implants and personalized jigs. J Bone Joint Surg Am 91:69–76PubMedCrossRef
13.
Zurück zum Zitat Hansen E, Bozic KJ (2009) The impact of disruptive innovations in orthopaedics. Clin Orthop Relat Res 467:2512–2520PubMedCrossRef Hansen E, Bozic KJ (2009) The impact of disruptive innovations in orthopaedics. Clin Orthop Relat Res 467:2512–2520PubMedCrossRef
14.
Zurück zum Zitat Hernigou P, Deschamps G (2004) Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty. J Bone Joint Surg Am 86:506–511PubMed Hernigou P, Deschamps G (2004) Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty. J Bone Joint Surg Am 86:506–511PubMed
16.
Zurück zum Zitat Hofbauer M, Muller B, Murawski CD, Karlsson J, Fu FH (2013) Innovation in orthopaedic surgery as it relates to evidence-based practice. Knee Surg Sports Traumatol Arthrosc 21:511–514PubMedCrossRef Hofbauer M, Muller B, Murawski CD, Karlsson J, Fu FH (2013) Innovation in orthopaedic surgery as it relates to evidence-based practice. Knee Surg Sports Traumatol Arthrosc 21:511–514PubMedCrossRef
17.
Zurück zum Zitat Hoshino Y, Araujo P, Ahiden M, Samuelsson K, Muller B, Hofbauer M, Wolf MR, Irrgang JJ, Fu FH, Musahl V (2013) Quantitative evaluation of the pivot shift by image analysis using the iPad. Knee Surg Sports Traumatol Arthrosc 21:975–980PubMedCrossRef Hoshino Y, Araujo P, Ahiden M, Samuelsson K, Muller B, Hofbauer M, Wolf MR, Irrgang JJ, Fu FH, Musahl V (2013) Quantitative evaluation of the pivot shift by image analysis using the iPad. Knee Surg Sports Traumatol Arthrosc 21:975–980PubMedCrossRef
18.
Zurück zum Zitat Howell SM, Kuznik K, Hull ML, Siston RA (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857–863PubMedCrossRef Howell SM, Kuznik K, Hull ML, Siston RA (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857–863PubMedCrossRef
19.
Zurück zum Zitat Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007PubMedCrossRef Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007PubMedCrossRef
20.
Zurück zum Zitat Johnson DR (2011) The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: results from practice. Am J Orthop (Belle Mead NJ) 40:13–16 Johnson DR (2011) The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: results from practice. Am J Orthop (Belle Mead NJ) 40:13–16
21.
Zurück zum Zitat Karia M, Masjedi M, Andrews B, Jaffry Z, Cobb J (2013) Robotic assistance enables inexperienced surgeons to perform unicompartmental knee arthroplasties on dry bone models with accuracy superior to conventional methods. Adv Orthop. doi:10.1155/2013/481039 PubMed Karia M, Masjedi M, Andrews B, Jaffry Z, Cobb J (2013) Robotic assistance enables inexperienced surgeons to perform unicompartmental knee arthroplasties on dry bone models with accuracy superior to conventional methods. Adv Orthop. doi:10.​1155/​2013/​481039 PubMed
22.
Zurück zum Zitat Kim SJ, Bae JH, Lim HC (2012) Factors affecting the postoperative limb alignment and clinical outcome after Oxford unicompartmental knee arthroplasty. J Arthroplasty 27:1210–1215PubMedCrossRef Kim SJ, Bae JH, Lim HC (2012) Factors affecting the postoperative limb alignment and clinical outcome after Oxford unicompartmental knee arthroplasty. J Arthroplasty 27:1210–1215PubMedCrossRef
23.
Zurück zum Zitat Koeck FX, Beckmann J, Luring C, Rath B, Grifka J, Basad E (2011) Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty. Knee 18:294–299PubMedCrossRef Koeck FX, Beckmann J, Luring C, Rath B, Grifka J, Basad E (2011) Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty. Knee 18:294–299PubMedCrossRef
24.
Zurück zum Zitat Krishnan SP, Dawood A, Richards R, Henckel J, Hart AJ (2012) A review of rapid prototyped surgical guides for patient-specific total knee replacement. J Bone Joint Surg Br 94:1457–1461PubMed Krishnan SP, Dawood A, Richards R, Henckel J, Hart AJ (2012) A review of rapid prototyped surgical guides for patient-specific total knee replacement. J Bone Joint Surg Br 94:1457–1461PubMed
25.
Zurück zum Zitat Lombardi AVJ, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31:927–930PubMedCrossRef Lombardi AVJ, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31:927–930PubMedCrossRef
26.
Zurück zum Zitat Lombardi AV Jr, Frye BM (2012) Customization of cutting blocks: can this address the problem? Curr Rev Musculoskelet Med 5:309–314PubMedCrossRef Lombardi AV Jr, Frye BM (2012) Customization of cutting blocks: can this address the problem? Curr Rev Musculoskelet Med 5:309–314PubMedCrossRef
27.
Zurück zum Zitat Lonner JH, John TK, Conditt MA (2010) Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 468:141–146PubMedCrossRef Lonner JH, John TK, Conditt MA (2010) Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 468:141–146PubMedCrossRef
28.
Zurück zum Zitat Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of Visionaire patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28:469–473PubMedCrossRef Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of Visionaire patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28:469–473PubMedCrossRef
29.
Zurück zum Zitat Malchau H, Bragdon CR, Muratoglu OK (2011) The stepwise introduction of innovation into orthopedic surgery: the next level of dilemmas. J Arthroplasty 26:825–831PubMedCrossRef Malchau H, Bragdon CR, Muratoglu OK (2011) The stepwise introduction of innovation into orthopedic surgery: the next level of dilemmas. J Arthroplasty 26:825–831PubMedCrossRef
30.
Zurück zum Zitat Mont MA, McElroy MJ, Johnson AJ, Pivec R (2013) Single-use instruments, cutting blocks, and trials increase efficiency in the operating room during total knee arthroplasty. A prospective comparison of navigated and non-navigated cases. J Arthroplasty 28:1135–1140PubMedCrossRef Mont MA, McElroy MJ, Johnson AJ, Pivec R (2013) Single-use instruments, cutting blocks, and trials increase efficiency in the operating room during total knee arthroplasty. A prospective comparison of navigated and non-navigated cases. J Arthroplasty 28:1135–1140PubMedCrossRef
31.
Zurück zum Zitat Nam D, McArthur BA, Cross MB, Pearle AD, Mayman DJ, Haas SB (2012) Patient-specific instrumentation in total knee arthroplasty: a review. J Knee Surg 25:213–219PubMedCrossRef Nam D, McArthur BA, Cross MB, Pearle AD, Mayman DJ, Haas SB (2012) Patient-specific instrumentation in total knee arthroplasty: a review. J Knee Surg 25:213–219PubMedCrossRef
32.
Zurück zum Zitat Nam D, Weeks KD, Reinhardt KR, Nawabi DH, Cross MB, Mayman DJ (2013) Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results. J Arthroplasty 28:255–261PubMedCrossRef Nam D, Weeks KD, Reinhardt KR, Nawabi DH, Cross MB, Mayman DJ (2013) Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results. J Arthroplasty 28:255–261PubMedCrossRef
33.
Zurück zum Zitat Nam D, Maher PA, Rebolledo BJ, Nawabi DH, McLawhorn AS, Pearle AD (2013) Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee 20:263–267PubMedCrossRef Nam D, Maher PA, Rebolledo BJ, Nawabi DH, McLawhorn AS, Pearle AD (2013) Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee 20:263–267PubMedCrossRef
34.
Zurück zum Zitat Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107PubMedCrossRef Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99–107PubMedCrossRef
35.
Zurück zum Zitat Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894PubMedCrossRef Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894PubMedCrossRef
36.
Zurück zum Zitat Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895–902PubMedCrossRef Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895–902PubMedCrossRef
37.
Zurück zum Zitat Noble JWJ, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27:153–155PubMedCrossRef Noble JWJ, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27:153–155PubMedCrossRef
38.
Zurück zum Zitat Pietsch M, Djahani O, Zweiger C, Plattner F, Radi R, Tschauner C, Hofmann S (2012) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-012-2284-z Pietsch M, Djahani O, Zweiger C, Plattner F, Radi R, Tschauner C, Hofmann S (2012) Custom-fit minimally invasive total knee arthroplasty: effect on blood loss and early clinical outcomes. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-012-2284-z
39.
Zurück zum Zitat Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140PubMedCrossRef Rosenberger RE, Fink C, Quirbach S, Attal R, Tecklenburg K, Hoser C (2008) The immediate effect of navigation on implant accuracy in primary mini-invasive unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 16:1133–1140PubMedCrossRef
40.
Zurück zum Zitat Ross JS, Mocanu M, Lampropulos JF, Tse T, Krumholz HM (2013) Time to publication among completed clinical trials. JAMA Intern Med 173:825–828PubMed Ross JS, Mocanu M, Lampropulos JF, Tse T, Krumholz HM (2013) Time to publication among completed clinical trials. JAMA Intern Med 173:825–828PubMed
41.
Zurück zum Zitat Slover JD, Rubash HE, Malchau H, Bosco JA (2012) Cost-effectiveness analysis of custom total knee cutting blocks. J Arthroplasty 27:180–185PubMedCrossRef Slover JD, Rubash HE, Malchau H, Bosco JA (2012) Cost-effectiveness analysis of custom total knee cutting blocks. J Arthroplasty 27:180–185PubMedCrossRef
42.
Zurück zum Zitat Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571–1575PubMedCrossRef Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571–1575PubMedCrossRef
43.
Zurück zum Zitat Stronach BM, Pelt CE, Erickson J, Peters CL (2013) Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 471:169–174PubMedCrossRef Stronach BM, Pelt CE, Erickson J, Peters CL (2013) Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 471:169–174PubMedCrossRef
44.
Zurück zum Zitat Suter LG, Paltiel AD, Rome BN, Solomon DH, Thornhill TS, Abrams SK, Katz JN, Losina E (2013) Placing a price on medical device innovation: the example of total knee arthroplasty. PLoS One 8:e62709PubMedCrossRef Suter LG, Paltiel AD, Rome BN, Solomon DH, Thornhill TS, Abrams SK, Katz JN, Losina E (2013) Placing a price on medical device innovation: the example of total knee arthroplasty. PLoS One 8:e62709PubMedCrossRef
46.
Zurück zum Zitat Thienpont E (2012) Faster quadriceps recovery with the far medial subvastus approach in minimally invasive total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-012-2215-z Thienpont E (2012) Faster quadriceps recovery with the far medial subvastus approach in minimally invasive total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-012-2215-z
47.
Zurück zum Zitat Thienpont E (2013) Letter to the Editor to Lustig et al. ‘Unsatisfactory accuracy as determined by computer navigation of Visionaire patient-specific instrumentation for total knee arthroplasty’. J Arthroplasty. doi:10.1016/j.arth.2013.05.019 Thienpont E (2013) Letter to the Editor to Lustig et al. ‘Unsatisfactory accuracy as determined by computer navigation of Visionaire patient-specific instrumentation for total knee arthroplasty’. J Arthroplasty. doi:10.​1016/​j.​arth.​2013.​05.​019
48.
Zurück zum Zitat Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2013) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res. doi:10.1007/s11999-013-2997-4 Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2013) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res. doi:10.​1007/​s11999-013-2997-4
49.
Zurück zum Zitat Victor J, Van Doninck D, Labey L, Van Glabbeek F, Parizel P, Bellemans J (2009) A common reference frame for describing rotation of the distal femur: a ct-based kinematic study using cadavers. J Bone Joint Surg Br 91:683–690PubMedCrossRef Victor J, Van Doninck D, Labey L, Van Glabbeek F, Parizel P, Bellemans J (2009) A common reference frame for describing rotation of the distal femur: a ct-based kinematic study using cadavers. J Bone Joint Surg Br 91:683–690PubMedCrossRef
50.
Zurück zum Zitat Vundelinckx BJ, Bruckers L, De Mulder K, De Schepper J, Van Esbroeck G (2013) Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty. doi:10.1016/j.arth.2012.09.010 Vundelinckx BJ, Bruckers L, De Mulder K, De Schepper J, Van Esbroeck G (2013) Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty. doi:10.​1016/​j.​arth.​2012.​09.​010
51.
Zurück zum Zitat Watters TS, Mather RC 3rd, Browne JA, Berend KR, Lombardi AV, Bolognesi MP (2011) Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty. J Surg Orthop Adv 20:112–116PubMed Watters TS, Mather RC 3rd, Browne JA, Berend KR, Lombardi AV, Bolognesi MP (2011) Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty. J Surg Orthop Adv 20:112–116PubMed
52.
Zurück zum Zitat Weber P, Crispin A, Schmidutz F, Utzschneider S, Pietschmann MF, Jansson V, Müller PE (2013) Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-013-2370-x Weber P, Crispin A, Schmidutz F, Utzschneider S, Pietschmann MF, Jansson V, Müller PE (2013) Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-013-2370-x
Metadaten
Titel
Patient-specific instruments: industry’s innovation with a surgeon’s interest
verfasst von
Emmanuel Thienpont
Johan Bellemans
Hendrik Delport
Philippe Van Overschelde
Bart Stuyts
Karl Brabants
Jan Victor
Publikationsdatum
01.10.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 10/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2626-5

Weitere Artikel der Ausgabe 10/2013

Knee Surgery, Sports Traumatology, Arthroscopy 10/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.