Abstract

Providing functionally effective sensory feedback to users of prosthetics is a largely unsolved challenge. Traditional solutions require high band-widths for providing feedback for the control of manipulation and yet have been largely unsuccessful. In this study, we have explored a strategy that relies on temporally discrete sensory feedback that is technically simple to provide. According to the Discrete Event-driven Sensory feedback Control (DESC) policy, motor tasks in humans are organized in phases delimited by means of sensory encoded discrete mechanical events. To explore the applicability of DESC for control, we designed a paradigm in which healthy humans operated an artificial robot hand to lift and replace an instrumented object, a task that can readily be learned and mastered under visual control. Assuming that the central nervous system of humans naturally organizes motor tasks based on a strategy akin to DESC, we delivered short-lasting vibrotactile feedback related to events that are known to forcefully affect progression of the grasp-lift-and-hold task. After training, we determined whether the artificial feedback had been integrated with the sensorimotor control by introducing short delays and we indeed observed that the participants significantly delayed subsequent phases of the task. This study thus gives support to the DESC policy hypothesis. Moreover, it demonstrates that humans can integrate temporally discrete sensory feedback while controlling an artificial hand and invites further studies in which inexpensive, noninvasive technology could be used in clever ways to provide physiologically appropriate sensory feedback in upper limb prosthetics with much lower band-width requirements than with traditional solutions.
Literatur
Zurück zum Zitat Antfolk C, Bjorkman A, Frank SO, Sebelius F, Lundborg G, Rosen B (2012) Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. J Rehabil Med 44(8):702–707PubMedCrossRef Antfolk C, Bjorkman A, Frank SO, Sebelius F, Lundborg G, Rosen B (2012) Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin. J Rehabil Med 44(8):702–707PubMedCrossRef
Zurück zum Zitat Antfolk C, D’Alonzo M, Rosén B, Lundborg G, Sebelius F, Cipriani C (2013) Sensory feedback in upper limb prosthetics. Expert Rev Med Devices 10(1):45–54PubMedCrossRef Antfolk C, D’Alonzo M, Rosén B, Lundborg G, Sebelius F, Cipriani C (2013) Sensory feedback in upper limb prosthetics. Expert Rev Med Devices 10(1):45–54PubMedCrossRef
Zurück zum Zitat Chatterjee A, Chaubey P, Martin J, Thakor N (2008) Testing a prosthetic haptic feedback simulator with an interactive force matching task. J Prosthet Orthot 20(2):27–34CrossRef Chatterjee A, Chaubey P, Martin J, Thakor N (2008) Testing a prosthetic haptic feedback simulator with an interactive force matching task. J Prosthet Orthot 20(2):27–34CrossRef
Zurück zum Zitat Childress DS (1980) Closed-loop control in prosthetic systems: historical perspective. Ann Biomed Eng 8(4–6):293–303PubMedCrossRef Childress DS (1980) Closed-loop control in prosthetic systems: historical perspective. Ann Biomed Eng 8(4–6):293–303PubMedCrossRef
Zurück zum Zitat Cipriani C, Zaccone F, Micera S, Carrozza MC (2008) On the shared control of an EMG-controlled prosthetic hand: analysis of user–prosthesis interaction. IEEE Trans Robot 24(1):170–184CrossRef Cipriani C, Zaccone F, Micera S, Carrozza MC (2008) On the shared control of an EMG-controlled prosthetic hand: analysis of user–prosthesis interaction. IEEE Trans Robot 24(1):170–184CrossRef
Zurück zum Zitat Cipriani C, Controzzi M, Carrozza MC (2011) The SmartHand transradial prosthesis. J Neuroeng Rehabil 8(29):1–13 Cipriani C, Controzzi M, Carrozza MC (2011) The SmartHand transradial prosthesis. J Neuroeng Rehabil 8(29):1–13
Zurück zum Zitat Cipriani C, D’Alonzo M, Carrozza MC (2012) A miniature vibrotactile sensory substitution device for multifingered hand prosthetics. IEEE Trans Biomed Eng 59(2):400–408PubMedCrossRef Cipriani C, D’Alonzo M, Carrozza MC (2012) A miniature vibrotactile sensory substitution device for multifingered hand prosthetics. IEEE Trans Biomed Eng 59(2):400–408PubMedCrossRef
Zurück zum Zitat Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13(4):468–472PubMedCrossRef Dhillon GS, Horch KW (2005) Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans Neural Syst Rehabil Eng 13(4):468–472PubMedCrossRef
Zurück zum Zitat Flanagan JR, Bowman MC, Johansson RS (2006) Control strategies in object manipulation tasks. Curr Opin Neurobiol 16:650–659PubMedCrossRef Flanagan JR, Bowman MC, Johansson RS (2006) Control strategies in object manipulation tasks. Curr Opin Neurobiol 16:650–659PubMedCrossRef
Zurück zum Zitat Gordon AM, Westling G, Cole KJ, Johansson RS (1993) Memory representations underlying motor commands used during manipulation of common and novel objects. J Neurophysiol 69:1789–1796PubMed Gordon AM, Westling G, Cole KJ, Johansson RS (1993) Memory representations underlying motor commands used during manipulation of common and novel objects. J Neurophysiol 69:1789–1796PubMed
Zurück zum Zitat Hogan N, Bizzi E, Mussa-Ivaldi FA, Flash T (1987) Controlling multijoint motor behavior. Exerc Sport Sci Rev 15:153–190PubMed Hogan N, Bizzi E, Mussa-Ivaldi FA, Flash T (1987) Controlling multijoint motor behavior. Exerc Sport Sci Rev 15:153–190PubMed
Zurück zum Zitat Horch K, Meek S, Taylor TG, Hutchinson DT (2011) Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans Neural Syst Rehabil Eng 19(5):483–489PubMedCrossRef Horch K, Meek S, Taylor TG, Hutchinson DT (2011) Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans Neural Syst Rehabil Eng 19(5):483–489PubMedCrossRef
Zurück zum Zitat Johansson RS, Edin BB (1993) Predictive feed-forward sensory control during grasping and manipulation in man. Biomed Res 14(4):95–106 Johansson RS, Edin BB (1993) Predictive feed-forward sensory control during grasping and manipulation in man. Biomed Res 14(4):95–106
Zurück zum Zitat Johansson RS, Westling G (1984) Roles of glabrous skin receptors and sensorimotor memory in automatic control of precision grip when lifting rougher or more slippery objects. Exp Brain Res 56:550–564PubMedCrossRef Johansson RS, Westling G (1984) Roles of glabrous skin receptors and sensorimotor memory in automatic control of precision grip when lifting rougher or more slippery objects. Exp Brain Res 56:550–564PubMedCrossRef
Zurück zum Zitat Johansson RS, Westling G (1991) Afferent signals during manipulative tasks in man. In: Franzen O, Westman J (eds) Somatosensory mechanisms. Macmillan Press, London, pp 25–48 Johansson RS, Westling G (1991) Afferent signals during manipulative tasks in man. In: Franzen O, Westman J (eds) Somatosensory mechanisms. Macmillan Press, London, pp 25–48
Zurück zum Zitat Lundborg G (2003) Richard P. Bunge memorial lecture. Nerve injury and repair—a challenge to the plastic brain. J Peripher Nerv Syst 8:209–226PubMedCrossRef Lundborg G (2003) Richard P. Bunge memorial lecture. Nerve injury and repair—a challenge to the plastic brain. J Peripher Nerv Syst 8:209–226PubMedCrossRef
Zurück zum Zitat Mann RW, Reimers SD (1970) Kinesthetic sensing for the EMG controlled Boston Arm. IEEE Trans Man–Mach Syst 11(1):110–115CrossRef Mann RW, Reimers SD (1970) Kinesthetic sensing for the EMG controlled Boston Arm. IEEE Trans Man–Mach Syst 11(1):110–115CrossRef
Zurück zum Zitat Meek SG, Jacobsen SC, Goulding PP (1989) Extended physiologic taction: design and evaluation of a proportional force feedback system. J Rehabil Res Dev 26(3):53–62PubMed Meek SG, Jacobsen SC, Goulding PP (1989) Extended physiologic taction: design and evaluation of a proportional force feedback system. J Rehabil Res Dev 26(3):53–62PubMed
Zurück zum Zitat Panarese A, Edin B, Vecchi F, Carrozza MC, Johansson RS (2009) Humans can integrate force feedback to toes in their sensorimotor control of a robotic hand. IEEE Trans Neural Syst Rehabil Eng 17(6):560–567PubMedCrossRef Panarese A, Edin B, Vecchi F, Carrozza MC, Johansson RS (2009) Humans can integrate force feedback to toes in their sensorimotor control of a robotic hand. IEEE Trans Neural Syst Rehabil Eng 17(6):560–567PubMedCrossRef
Zurück zum Zitat Rosén B, Lundborg G, Dahlin LB, Holmberg J, Karlson B (1994) Nerve repair: correlation of restitution of functional sensibility with specific cognitive capacities. J Hand Surg 19:452–458CrossRef Rosén B, Lundborg G, Dahlin LB, Holmberg J, Karlson B (1994) Nerve repair: correlation of restitution of functional sensibility with specific cognitive capacities. J Hand Surg 19:452–458CrossRef
Zurück zum Zitat Rossini PM, Micera S, Benvenuto A et al (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121(5):777–783PubMedCrossRef Rossini PM, Micera S, Benvenuto A et al (2010) Double nerve intraneural interface implant on a human amputee for robotic hand control. Clin Neurophysiol 121(5):777–783PubMedCrossRef
Zurück zum Zitat Sasaki Y, Nakayama Y, Yoshida M (2002) Sensory feedback system using interferential current for EMG prosthetic hand. Eng Med Biol 24th Annu Conf Annu Fall Meet Biomed Eng Soc Proc Second Joint IEEE 3:2402–2403CrossRef Sasaki Y, Nakayama Y, Yoshida M (2002) Sensory feedback system using interferential current for EMG prosthetic hand. Eng Med Biol 24th Annu Conf Annu Fall Meet Biomed Eng Soc Proc Second Joint IEEE 3:2402–2403CrossRef
Zurück zum Zitat Saunders I, Vijayakumar S (2011) The role of feed-forward and feedback processes for closed-loop prosthesis control. J Neuroeng Rehabil 8(60):1–12 Saunders I, Vijayakumar S (2011) The role of feed-forward and feedback processes for closed-loop prosthesis control. J Neuroeng Rehabil 8(60):1–12
Zurück zum Zitat Sensinger JW, Schultz AE, Kuiken TA (2009) Examination of force discrimination in human upper limb amputees with reinnervated limb sensation following peripheral nerve transfer. IEEE Trans Neural Syst Rehabil Eng 17(5):438–444PubMedCrossRefPubMedCentral Sensinger JW, Schultz AE, Kuiken TA (2009) Examination of force discrimination in human upper limb amputees with reinnervated limb sensation following peripheral nerve transfer. IEEE Trans Neural Syst Rehabil Eng 17(5):438–444PubMedCrossRefPubMedCentral
Zurück zum Zitat Szeto AY, Saunders FA (1982) Electrocutaneous stimulation for sensory communication in rehabilitation engineering. IEEE Trans Biomed Eng 4:300–308CrossRef Szeto AY, Saunders FA (1982) Electrocutaneous stimulation for sensory communication in rehabilitation engineering. IEEE Trans Biomed Eng 4:300–308CrossRef
Zurück zum Zitat Tan D, Schiefer M, Keith MW, Anderson R, Tyler DJ (2013) Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in a human amputee. In: International IEEE/EMBS Conference on Neural Engineering (NER), pp 859–862 Tan D, Schiefer M, Keith MW, Anderson R, Tyler DJ (2013) Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in a human amputee. In: International IEEE/EMBS Conference on Neural Engineering (NER), pp 859–862
Zurück zum Zitat Tsakiris M, Haggard P (2005) The rubber hand illusion revisited: visuotactile integration and self-attribution. J Exp Psychol Hum Percept Perform 3:80–91CrossRef Tsakiris M, Haggard P (2005) The rubber hand illusion revisited: visuotactile integration and self-attribution. J Exp Psychol Hum Percept Perform 3:80–91CrossRef
Zurück zum Zitat Westling G, Johansson RS (1987) Responses in glabrous skin mechanoreceptors during precision grip in humans. Exp Brain Res 66:128–140PubMedCrossRef Westling G, Johansson RS (1987) Responses in glabrous skin mechanoreceptors during precision grip in humans. Exp Brain Res 66:128–140PubMedCrossRef
Metadaten
Titel
Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand
verfasst von
Christian Cipriani
Jacob L. Segil
Francesco Clemente
Richard F. ff. Weir
Benoni Edin
Publikationsdatum
01.11.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Experimental Brain Research / Ausgabe 11/2014
Print ISSN: 0014-4819
Elektronische ISSN: 1432-1106
DOI
https://doi.org/10.1007/s00221-014-4024-8

Weitere Artikel der Ausgabe 11/2014

Experimental Brain Research 11/2014 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Sozialer Aufstieg verringert Demenzgefahr

24.05.2024 Demenz Nachrichten

Ein hohes soziales Niveau ist mit die beste Versicherung gegen eine Demenz. Noch geringer ist das Demenzrisiko für Menschen, die sozial aufsteigen: Sie gewinnen fast zwei demenzfreie Lebensjahre. Umgekehrt steigt die Demenzgefahr beim sozialen Abstieg.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Was nützt die Kraniektomie bei schwerer tiefer Hirnblutung?

17.05.2024 Hirnblutung Nachrichten

Eine Studie zum Nutzen der druckentlastenden Kraniektomie nach schwerer tiefer supratentorieller Hirnblutung deutet einen Nutzen der Operation an. Für überlebende Patienten ist das dennoch nur eine bedingt gute Nachricht.

Thrombektomie auch bei großen Infarkten von Vorteil

16.05.2024 Ischämischer Schlaganfall Nachrichten

Auch ein sehr ausgedehnter ischämischer Schlaganfall scheint an sich kein Grund zu sein, von einer mechanischen Thrombektomie abzusehen. Dafür spricht die LASTE-Studie, an der Patienten und Patientinnen mit einem ASPECTS von maximal 5 beteiligt waren.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.