Between September 2000 and February 2002 we inserted 120 total knee arthroplasties. In 60 patients we used the standard technique, and in 60 patients we used the OrthoPilot navigation system. Postoperatively all patients had standing long radiographs of the lower extremity from the hip joint to the ankle. We considered the ideal value of the anatomic lateral tibiofemoral angle (LTFA) to be 174°. In the standard group the mean value of LTFA was 174.9° and in the navigation group 174.3°. A deviation between 0° and 2° from the ideal value was seen in 42 cases in the standard group and in 53 cases in the navigation group. In the standard group 18 cases had a deviation of more than 2.1°, whereas there were only seven cases in the navigation group with a deviation exceeding 2.1°. There were no complications related to the use of the navigation system. The system affords a possibility to place femoral and tibial components precisely with less axis deviation than with the conventional technique.
Literatur
1.
Zurück zum Zitat Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty. Clin Orthop 173:178–183PubMed Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty. Clin Orthop 173:178–183PubMed
2.
Zurück zum Zitat Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 354:49–56 Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 354:49–56
3.
Zurück zum Zitat Elloy MA, Manning MP, Johnson R (1992) Accuracy of intramedullary alignment in total knee replacement. J Biomed 14:363–370 Elloy MA, Manning MP, Johnson R (1992) Accuracy of intramedullary alignment in total knee replacement. J Biomed 14:363–370
4.
Zurück zum Zitat Gossé F, Brack C, Gotte H, Roth M, Ruhmann O, Schweikard A, Vahldiek M (1997) Roboterunterstützung in der Knieendoprothetik. Orthopäde 26:258–266 Gossé F, Brack C, Gotte H, Roth M, Ruhmann O, Schweikard A, Vahldiek M (1997) Roboterunterstützung in der Knieendoprothetik. Orthopäde 26:258–266
5.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg [Br] 73:709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg [Br] 73:709–714
6.
Zurück zum Zitat Jenny JY, Boeri C (2001) Navigiert implantierte Knietotalendoprothesen—eine Vergleichsstudie zum konvetionellen Instrumentarium. Z Orthop 139:117–119CrossRefPubMed Jenny JY, Boeri C (2001) Navigiert implantierte Knietotalendoprothesen—eine Vergleichsstudie zum konvetionellen Instrumentarium. Z Orthop 139:117–119CrossRefPubMed
7.
Zurück zum Zitat Katz MM, Hungerford DS, Krakow KA, Lennox DW (1987) Results of total knee arthroplasty after failed proximal tibial osteotomy for osteoarthritis. J Bone Joint Surg [Am] 69:225–233 Katz MM, Hungerford DS, Krakow KA, Lennox DW (1987) Results of total knee arthroplasty after failed proximal tibial osteotomy for osteoarthritis. J Bone Joint Surg [Am] 69:225–233
8.
Zurück zum Zitat Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop 331:102–106 Lonner JH, Laird MT, Stuchin SA (1996) Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop 331:102–106
9.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59:77–79 Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 59:77–79
10.
Zurück zum Zitat Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in der Knieendoprothetik—vorläufige klinische Erfahrungen und prospektiv vergleichende Studie gegenüber konventioneller Implantationstechnik. Z Orthop 139:100–116 Mielke RK, Clemens U, Jens JH, Kershally S (2001) Navigation in der Knieendoprothetik—vorläufige klinische Erfahrungen und prospektiv vergleichende Studie gegenüber konventioneller Implantationstechnik. Z Orthop 139:100–116
11.
Zurück zum Zitat Oswald MH, Jakob RP, Schneider E, Hoogewood HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed Oswald MH, Jakob RP, Schneider E, Hoogewood HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed
12.
Zurück zum Zitat Patel DV, Ferris BD, Aichroth PM (1991) Radiological study of alignment after total knee replacement. Int Ortop 15:209–210 Patel DV, Ferris BD, Aichroth PM (1991) Radiological study of alignment after total knee replacement. Int Ortop 15:209–210
13.
Zurück zum Zitat Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 1:67–72 Petersen TL, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 1:67–72
14.
Zurück zum Zitat Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg [Br] 83:819–824 Prakash U, Wigderowitz CA, McGurty DW, Rowley DI (2001) Computerised measurement of tibiofemoral alignment. J Bone Joint Surg [Br] 83:819–824
15.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop 299:153–156PubMed
16.
Zurück zum Zitat Saleh KJ, Sherman P, Katkin P, Windsor R et al (2001) Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg [Am] 83:1144–1148 Saleh KJ, Sherman P, Katkin P, Windsor R et al (2001) Total knee arthroplasty after open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg [Am] 83:1144–1148
17.
Zurück zum Zitat Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84:90–98 Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 84:90–98
18.
Zurück zum Zitat Toksvig-Larsen S et al (1998) Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg [Br] 80:295–297 Toksvig-Larsen S et al (1998) Fixation of the tibial component of total knee arthroplasty after high tibial osteotomy. J Bone Joint Surg [Br] 80:295–297
19.
Zurück zum Zitat Townley ChO (1985) The anatomic total knee resurfacing arthroplasty. Clin Orthop 192:82–96PubMed Townley ChO (1985) The anatomic total knee resurfacing arthroplasty. Clin Orthop 192:82–96PubMed
20.
Zurück zum Zitat Waugh MTW (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg [Br] 67:551–556 Waugh MTW (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Joint Surg [Br] 67:551–556
21.
Zurück zum Zitat Windsor RE, Insall JN, Vince KG (1988) Technical considerations of total knee arthroplasty after proximal tibial osteotomy. J Bone Joint Surg [Am] 70:547–555 Windsor RE, Insall JN, Vince KG (1988) Technical considerations of total knee arthroplasty after proximal tibial osteotomy. J Bone Joint Surg [Am] 70:547–555
Metadaten
Titel
Total knee arthroplasty implanted with and without kinematic navigation
verfasst von
R. Hart
M. Janeček
A. Chaker
P. Buček
Publikationsdatum
01.12.2003
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 6/2003
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-003-0501-6

Weitere Artikel der Ausgabe 6/2003

International Orthopaedics 6/2003 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.