Abstract

We implanted 60 posterior stabilized total knee prostheses (P.F.C. Sigma, DePuy, Warsaw, USA). In 30 cases, we used a CT-free navigation system (Vector Vision, Brain LAB, Heimstetten, Germany), and in 30 matched-paired controls, we used a conventional manual implantation. We compared postoperative long-leg radiographs in the two groups. The results revealed a significant difference in favor of navigation. In addition, we compared the preoperative anteroposterior dimension of the femoral condyle with the postoperative value. While there were no significant differences in the preoperative anteroposterior dimension of the femoral condyle between the two groups, the postoperative value in the navigation group was significantly larger than that of the preoperative value. Therefore, surgeons using navigation systems should guard against the possibility of oversizing when determining the size of the femoral component.
Literatur
1.
Zurück zum Zitat Daluga D, Lombardi AV, Mallory TH et al (1991) Knee manipulation following total knee arthroplasty. Analysis of prognostic variables. J Arthroplasty 6:119–128PubMed Daluga D, Lombardi AV, Mallory TH et al (1991) Knee manipulation following total knee arthroplasty. Analysis of prognostic variables. J Arthroplasty 6:119–128PubMed
2.
Zurück zum Zitat Delp SL, Stulberg SD, Davies B et al (1998) Computer assisted knee replacement. Clin Orthop 354:49–56CrossRefPubMed Delp SL, Stulberg SD, Davies B et al (1998) Computer assisted knee replacement. Clin Orthop 354:49–56CrossRefPubMed
3.
Zurück zum Zitat Hart R, Jaenecek M, Chaker A et al (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369CrossRefPubMed Hart R, Jaenecek M, Chaker A et al (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366–369CrossRefPubMed
4.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14PubMed Insall JN, Dorr LD, Scott RD et al (1989) Rationale of the Knee Society clinical rating system. Clin Orthop 248:13–14PubMed
5.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714PubMed
6.
Zurück zum Zitat Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87:645–652PubMed Jenny JY, Boeri C (2001) Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation. Rev Chir Orthop Reparatrice Appar Mot 87:645–652PubMed
7.
Zurück zum Zitat Mielke RK, Clemens U, Jens JH et al (2001) Navigation in knee endoprosthesis implantation-preliminary clinical experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116CrossRefPubMed Mielke RK, Clemens U, Jens JH et al (2001) Navigation in knee endoprosthesis implantation-preliminary clinical experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb 139:109–116CrossRefPubMed
8.
Zurück zum Zitat Nizard R, the GUEPAR group (2002) Computer assisted surgery for total knee arthroplasty. Acta Orthop Belgica 68:215–230 Nizard R, the GUEPAR group (2002) Computer assisted surgery for total knee arthroplasty. Acta Orthop Belgica 68:215–230
9.
Zurück zum Zitat Oswald MH, Jakob RP, Schneider E et al (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed Oswald MH, Jakob RP, Schneider E et al (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMed
10.
Zurück zum Zitat Saragaglia D, Picard F, Chaussard C et al (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed Saragaglia D, Picard F, Chaussard C et al (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed
11.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H et al (2003) Positioning of total knee arthroplasty with and without navigation support. J Bone Joint Surg Br 85:830–835PubMed Sparmann M, Wolke B, Czupalla H et al (2003) Positioning of total knee arthroplasty with and without navigation support. J Bone Joint Surg Br 85:830–835PubMed
12.
Zurück zum Zitat Stindel E, Briard JL, Merloz P et al (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg 7:156–168CrossRefPubMed Stindel E, Briard JL, Merloz P et al (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg 7:156–168CrossRefPubMed
13.
Zurück zum Zitat Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop 416:177–189PubMed Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop 416:177–189PubMed
14.
Zurück zum Zitat Stulberg SD, Picard F, Saragaglia D (2000) Computer-assisted total knee replacement arthroplasty. Op Tech Orthop 10:25–39 Stulberg SD, Picard F, Saragaglia D (2000) Computer-assisted total knee replacement arthroplasty. Op Tech Orthop 10:25–39
15.
Zurück zum Zitat Stulberg SD, Beng PL, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am Suppl 84:90–98 Stulberg SD, Beng PL, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am Suppl 84:90–98
16.
Zurück zum Zitat Tillet E, Engh G, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop 230:176–181PubMed Tillet E, Engh G, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop 230:176–181PubMed
Metadaten
Titel
Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
verfasst von
Tomoyuki Matsumoto
Nobuhiro Tsumura
Masahiro Kurosaka
Hirotsugu Muratsu
Ryosuke Kuroda
Katsuhiko Ishimoto
Kazuo Tsujimoto
Ryoichi Shiba
Shinichi Yoshiya
Publikationsdatum
01.10.2004
Erschienen in
International Orthopaedics / Ausgabe 5/2004
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-004-0562-1

Weitere Artikel der Ausgabe 5/2004

International Orthopaedics 5/2004 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.