Skip to main content
Erschienen in: International Orthopaedics 2/2007

01.04.2007 | Original Paper

The Adaptiva custom-made stem—our reasons for not using it anymore

verfasst von: Patrik Karl Reize, Nikolaus Wülker

Erschienen in: International Orthopaedics | Ausgabe 2/2007

Einloggen, um Zugang zu erhalten

Abstract

The Adaptiva custom-made stem is a hip stem anchored by fit and fill press-fit into the proximal femur and manufacture is based on computed tomography (CT) scanning. Its concept was developed for primary and revision hip arthroplasty in younger patients in our clinic. We present the advantages and the disadvantages of the system. After 66 months 98.9% of the patients are satisfied with the surgical outcome; 86% attained very good and 9% good results according to the Merle d’Aubigné score. Despite good clinical results and a high satisfaction rate, we stopped using this stem because we do not see any advantages in comparison with standard implants and feel that the price for a custom-made stem for primary hip arthroplasty is too high.
Literatur
1.
Zurück zum Zitat Arabmotlagh M, Hennings T, Rittmeister M (2003) Femoral periprosthetic bone remodeling to the proximal femur after implantation of custom made anatomic and standard straight stem hip prostheses. Z Orthop Ihre Grenzgeb 141(5):519–525PubMedCrossRef Arabmotlagh M, Hennings T, Rittmeister M (2003) Femoral periprosthetic bone remodeling to the proximal femur after implantation of custom made anatomic and standard straight stem hip prostheses. Z Orthop Ihre Grenzgeb 141(5):519–525PubMedCrossRef
2.
Zurück zum Zitat Aldinger G, Weipert A (1991) 3D-based production of hip joints: the Aldinger system. Radiologe 31:474–480PubMed Aldinger G, Weipert A (1991) 3D-based production of hip joints: the Aldinger system. Radiologe 31:474–480PubMed
3.
Zurück zum Zitat Aldinger P, Thomsen M, Mau H, Ewerbeck V, Breusch S (2003) Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand 74(3):253–258PubMedCrossRef Aldinger P, Thomsen M, Mau H, Ewerbeck V, Breusch S (2003) Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients. Acta Orthop Scand 74(3):253–258PubMedCrossRef
4.
Zurück zum Zitat Arcq M (1973) Die periartikuläre Ossifikation—eine Komplikation der Totalendoprothese des Hüftgelenkes. Arch Orthop Trauma Surg 77(2):108–131 Arcq M (1973) Die periartikuläre Ossifikation—eine Komplikation der Totalendoprothese des Hüftgelenkes. Arch Orthop Trauma Surg 77(2):108–131
5.
Zurück zum Zitat Chang PB, Robie BH, Bartel DL (1999) Preclinical cost analysis of orthopaedic implants: a custom versus standard cementless femoral component for revision total hip arthroplasty. J Biomech 32(12):1309–1318PubMedCrossRef Chang PB, Robie BH, Bartel DL (1999) Preclinical cost analysis of orthopaedic implants: a custom versus standard cementless femoral component for revision total hip arthroplasty. J Biomech 32(12):1309–1318PubMedCrossRef
6.
Zurück zum Zitat Collis DK (1988) Long-term results of an individual surgeon. Orthop Clin North Am 19(3):541–550PubMed Collis DK (1988) Long-term results of an individual surgeon. Orthop Clin North Am 19(3):541–550PubMed
7.
Zurück zum Zitat Cuckler J (2005) Limb length and stability in total hip replacement. Orthopedics 28(9):951–953PubMed Cuckler J (2005) Limb length and stability in total hip replacement. Orthopedics 28(9):951–953PubMed
8.
Zurück zum Zitat Eingartner C, Heigele T, Dieter J, Winter E, Weise K (2003) Long-term results with the BiCONTACT system—aspects to investigate and to learn from. Int Orthop 27(Suppl 1):S11–S15PubMed Eingartner C, Heigele T, Dieter J, Winter E, Weise K (2003) Long-term results with the BiCONTACT system—aspects to investigate and to learn from. Int Orthop 27(Suppl 1):S11–S15PubMed
9.
Zurück zum Zitat Götze C, Steens W, Vieth V, Poremba C, Claes L, Steinbeck J (2002) Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech 17(4):267–273CrossRef Götze C, Steens W, Vieth V, Poremba C, Claes L, Steinbeck J (2002) Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesis. Clin Biomech 17(4):267–273CrossRef
10.
Zurück zum Zitat Goldstein W, Gordon A, Branson J (2005) Leg length inequality in total hip arthroplasty. Orthopedics 28(9):1037–1040 Goldstein W, Gordon A, Branson J (2005) Leg length inequality in total hip arthroplasty. Orthopedics 28(9):1037–1040
11.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) Modes of failure of cemented stem-type femoral components. Clin Orthop 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) Modes of failure of cemented stem-type femoral components. Clin Orthop 141:17–27PubMed
12.
Zurück zum Zitat Hua J, Walker PS (1994) Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs. J Bone Joint Surg Am 76(1):95–103PubMed Hua J, Walker PS (1994) Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs. J Bone Joint Surg Am 76(1):95–103PubMed
13.
Zurück zum Zitat Hua J, Walker PS (1995) Closeness of fit of uncemented stems improves the strain distribution in the femur. J Orthop Res 13(3):339–346PubMedCrossRef Hua J, Walker PS (1995) Closeness of fit of uncemented stems improves the strain distribution in the femur. J Orthop Res 13(3):339–346PubMedCrossRef
14.
Zurück zum Zitat Küsswetter W, Sell S (1993) Mittelfristige Ergebnisse mit dem zementfreien individuellen Femurersatz. Z Orthop 131:553–557PubMedCrossRef Küsswetter W, Sell S (1993) Mittelfristige Ergebnisse mit dem zementfreien individuellen Femurersatz. Z Orthop 131:553–557PubMedCrossRef
15.
Zurück zum Zitat Kutschera H-P, Eyb R, Schartelmüller T, Toma C, Zweymüller K (1993) Das zementfreie Zweymüller Hüft-System. Ergebnisse einer 5-Jahres-Nachuntersuchung. Z Orthop 131:513–517PubMed Kutschera H-P, Eyb R, Schartelmüller T, Toma C, Zweymüller K (1993) Das zementfreie Zweymüller Hüft-System. Ergebnisse einer 5-Jahres-Nachuntersuchung. Z Orthop 131:513–517PubMed
16.
Zurück zum Zitat Martini F (2001) Wertigkeit osteodensitometrischer Messungen unter besonderer Berücksichtigung des Verlaufs der periprothetischen Knochendichte der Individualendoprothesen Evolution-K und Adaptiva in Korrelation zur kortikalen Anlagefläche. Habilitationsschrift, Eberhard-Karls-Universität, Tübingen Martini F (2001) Wertigkeit osteodensitometrischer Messungen unter besonderer Berücksichtigung des Verlaufs der periprothetischen Knochendichte der Individualendoprothesen Evolution-K und Adaptiva in Korrelation zur kortikalen Anlagefläche. Habilitationsschrift, Eberhard-Karls-Universität, Tübingen
17.
Zurück zum Zitat Martini F, Lebherz C, Mayer F, Leichtle U, Kremling E, Sell S (2000) Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82(7):1065–1071PubMedCrossRef Martini F, Lebherz C, Mayer F, Leichtle U, Kremling E, Sell S (2000) Precision of the measurements of periprosthetic bone mineral density in hips with a custom-made femoral stem. J Bone Joint Surg Br 82(7):1065–1071PubMedCrossRef
18.
Zurück zum Zitat Reize P, Giehl J, Schanbacher J, Bronner R (2002) Clinical and radiological results of individual hip stems of the type Adaptiva without cement. Z Orthop Ihre Grenzgeb 140(3):304–309PubMedCrossRef Reize P, Giehl J, Schanbacher J, Bronner R (2002) Clinical and radiological results of individual hip stems of the type Adaptiva without cement. Z Orthop Ihre Grenzgeb 140(3):304–309PubMedCrossRef
19.
Zurück zum Zitat Rittmeister M, Eisenbeis K, Hanusek S, Yanik-Karaca Z, Starker M, Arabmotlagh M (2004) Assessment of implant position of CTX-custom-made stems with EBRA-FCA in 107 cases of total joint replacement. Z Orthop Ihre Grenzgeb 142(6):659–665PubMedCrossRef Rittmeister M, Eisenbeis K, Hanusek S, Yanik-Karaca Z, Starker M, Arabmotlagh M (2004) Assessment of implant position of CTX-custom-made stems with EBRA-FCA in 107 cases of total joint replacement. Z Orthop Ihre Grenzgeb 142(6):659–665PubMedCrossRef
20.
Zurück zum Zitat Robertson DD, Walker PS, Granholm JW, Nelson PC, Weiss PJ, Fishman EK, Magid D (1987) Design of custom hip stem prostheses using three-dimensional CT modeling. J Comput Assist Tomogr 11(5):804–809PubMedCrossRef Robertson DD, Walker PS, Granholm JW, Nelson PC, Weiss PJ, Fishman EK, Magid D (1987) Design of custom hip stem prostheses using three-dimensional CT modeling. J Comput Assist Tomogr 11(5):804–809PubMedCrossRef
21.
Zurück zum Zitat Sharp DJ, Porter KM (1985) The Charnley total hip arthroplasty in patients under 40. Clin Orthop 201:51–56PubMed Sharp DJ, Porter KM (1985) The Charnley total hip arthroplasty in patients under 40. Clin Orthop 201:51–56PubMed
22.
Zurück zum Zitat Traulsen F, Hassenpflug J, Hahne H (2001) Long-term results with cement-free total hip prostheses (Zweymüller). Z Orthop Ihre Grenzgeb 139(3):206–211PubMedCrossRef Traulsen F, Hassenpflug J, Hahne H (2001) Long-term results with cement-free total hip prostheses (Zweymüller). Z Orthop Ihre Grenzgeb 139(3):206–211PubMedCrossRef
23.
Zurück zum Zitat Wettstein M, Mouhsine E, Argenson JN, Rubin PJ, Aubaniac JM, Leyvraz PF (2005) Three-dimensional computed cementless custom femoral stems in young patients: midterm follow-up. Clin Orthop Relat Res 437:169–175PubMedCrossRef Wettstein M, Mouhsine E, Argenson JN, Rubin PJ, Aubaniac JM, Leyvraz PF (2005) Three-dimensional computed cementless custom femoral stems in young patients: midterm follow-up. Clin Orthop Relat Res 437:169–175PubMedCrossRef
24.
Zurück zum Zitat Wick M, Lester D (2004) Radiological changes in second- and third-generation Zweymüller stems. J Bone Jt Surg Br 86(8):1108–1114CrossRef Wick M, Lester D (2004) Radiological changes in second- and third-generation Zweymüller stems. J Bone Jt Surg Br 86(8):1108–1114CrossRef
Metadaten
Titel
The Adaptiva custom-made stem—our reasons for not using it anymore
verfasst von
Patrik Karl Reize
Nikolaus Wülker
Publikationsdatum
01.04.2007
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 2/2007
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-006-0160-5

Weitere Artikel der Ausgabe 2/2007

International Orthopaedics 2/2007 Zur Ausgabe

Letter to the Editor

Management of floating knee

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.