Skip to main content
Erschienen in: European Spine Journal 5/2010

01.05.2010 | Original Article

Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study

verfasst von: Keya Mao, Yan Wang, Songhua Xiao, Zhengsheng Liu, Yonggang Zhang, Xuesong Zhang, Zheng Wang, Ning Lu, Zhu Shourong, Zhang Xifeng, Cui Geng, Liu Baowei

Erschienen in: European Spine Journal | Ausgabe 5/2010

Einloggen, um Zugang zu erhalten

Abstract

Surgical treatment of complex severe spinal deformity, involving a scoliosis Cobb angle of more than 90° and kyphosis or vertebral and rib deformity, is challenging. Preoperative two-dimensional images resulting from plain film radiography, computed tomography (CT) and magnetic resonance imaging provide limited morphometric information. Although the three-dimensional (3D) reconstruction CT with special software can view the stereo and rotate the spinal image on the screen, it cannot show the full-scale spine and cannot directly be used on the operation table. This study was conducted to investigate the application of computer-designed polystyrene models in the treatment of complex severe spinal deformity. The study involved 16 cases of complex severe spinal deformity treated in our hospital between 1 May 2004 and 31 December 2007; the mean ± SD preoperative scoliosis Cobb angle was 118° ± 27°. The CT scanning digital imaging and communication in medicine (DICOM) data sets of the affected spinal segments were collected for 3D digital reconstruction and rapid prototyping to prepare computer-designed polystyrene models, which were applied in the treatment of these cases. The computer-designed polystyrene models allowed 3D observation and measurement of the deformities directly, which helped the surgeon to perform morphological assessment and communicate with the patient and colleagues. Furthermore, the models also guided the choice and placement of pedicle screws. Moreover, the models were used to aid in virtual surgery and guide the actual surgical procedure. The mean ± SD postoperative scoliosis Cobb angle was 42° ± 32°, and no serious complications such as spinal cord or major vascular injury occurred. The use of computer-designed polystyrene models could provide more accurate morphometric information and facilitate surgical correction of complex severe spinal deformity.
Literatur
1.
Zurück zum Zitat Ackerman MJ (1999) The Visible Human Project: a resource for education. Acad Med 74:667–670CrossRefPubMed Ackerman MJ (1999) The Visible Human Project: a resource for education. Acad Med 74:667–670CrossRefPubMed
2.
Zurück zum Zitat Ackerman MJ, Spitzer VM, Scherzinger AL, Whitlock DG (1995) The Visible Human data set: an image resource for anatomical visualization. Medinfo 8 Pt 2:1195–1198PubMed Ackerman MJ, Spitzer VM, Scherzinger AL, Whitlock DG (1995) The Visible Human data set: an image resource for anatomical visualization. Medinfo 8 Pt 2:1195–1198PubMed
3.
Zurück zum Zitat Aliabadi H, Grant G (2008) Congenital thoracolumbar spine deformities. Neurosurgery 63(3 Suppl):78–85CrossRefPubMed Aliabadi H, Grant G (2008) Congenital thoracolumbar spine deformities. Neurosurgery 63(3 Suppl):78–85CrossRefPubMed
4.
Zurück zum Zitat Chang KW (2003) Cantilever bending technique for treatment of large and rigid scoliosis. Spine 28:2452–2458CrossRefPubMed Chang KW (2003) Cantilever bending technique for treatment of large and rigid scoliosis. Spine 28:2452–2458CrossRefPubMed
5.
Zurück zum Zitat D’Urso PS, Williamson OD, Thompson RG (2005) Biomodeling as an aid to spinal instrumentation. Spine 30:2841–2845CrossRefPubMed D’Urso PS, Williamson OD, Thompson RG (2005) Biomodeling as an aid to spinal instrumentation. Spine 30:2841–2845CrossRefPubMed
6.
Zurück zum Zitat Facanha-Filho FA, Winter RB, Lonstein JE et al (2001) Measurement accuracy in congenital scoliosis. J Bone Joint Surg [Am] 83:42–45 Facanha-Filho FA, Winter RB, Lonstein JE et al (2001) Measurement accuracy in congenital scoliosis. J Bone Joint Surg [Am] 83:42–45
7.
Zurück zum Zitat Guarino J, Tennyson S, McCain G, Bond L, Shea K, King H (2007) Rapid prototyping technology for surgeries of the pediatric spine and pelvis: benefits analysis. J Pediatr Orthop 27:955–960PubMed Guarino J, Tennyson S, McCain G, Bond L, Shea K, King H (2007) Rapid prototyping technology for surgeries of the pediatric spine and pelvis: benefits analysis. J Pediatr Orthop 27:955–960PubMed
8.
Zurück zum Zitat Hamzaoglu A, Ozturk C, Tezer M, Aydogan M, Sarier M, Talu U (2007) Simultaneous surgical treatment in congenital scoliosis and/or kyphosis associated with intraspinal abnormalities. Spine 32:2880–2884CrossRefPubMed Hamzaoglu A, Ozturk C, Tezer M, Aydogan M, Sarier M, Talu U (2007) Simultaneous surgical treatment in congenital scoliosis and/or kyphosis associated with intraspinal abnormalities. Spine 32:2880–2884CrossRefPubMed
9.
Zurück zum Zitat Hedequist DJ (2007) Surgical treatment of congenital scoliosis. Orthop Clin North Am 38:497–509CrossRefPubMed Hedequist DJ (2007) Surgical treatment of congenital scoliosis. Orthop Clin North Am 38:497–509CrossRefPubMed
10.
Zurück zum Zitat Hedequist DJ, Emans JB (2003) The correlation of preoperative three-dimensional computed tomography reconstructions with operative findings in congenital scoliosis. Spine 28:2531–2534CrossRefPubMed Hedequist DJ, Emans JB (2003) The correlation of preoperative three-dimensional computed tomography reconstructions with operative findings in congenital scoliosis. Spine 28:2531–2534CrossRefPubMed
11.
Zurück zum Zitat Lermusiaux P, Leroux C, Tasse JC et al (2001) Aortic aneurysm: construction of a life-size model by rapid prototyping. Ann Vasc Surg 15:131–135CrossRefPubMed Lermusiaux P, Leroux C, Tasse JC et al (2001) Aortic aneurysm: construction of a life-size model by rapid prototyping. Ann Vasc Surg 15:131–135CrossRefPubMed
12.
Zurück zum Zitat Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Halm HF (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg [Am] 84:359–368 Liljenqvist UR, Allkemper T, Hackenberg L, Link TM, Steinbeck J, Halm HF (2002) Analysis of vertebral morphology in idiopathic scoliosis with use of magnetic resonance imaging and multiplanar reconstruction. J Bone Joint Surg [Am] 84:359–368
13.
14.
Zurück zum Zitat Mizutani J, Matsubara T, Fukuoka M et al (2008) Application of full-scale three-dimensional models in patients with rheumatoid cervical spine. Eur Spine J 17:644–649CrossRefPubMed Mizutani J, Matsubara T, Fukuoka M et al (2008) Application of full-scale three-dimensional models in patients with rheumatoid cervical spine. Eur Spine J 17:644–649CrossRefPubMed
15.
Zurück zum Zitat Newton PO, Hahn GW, Fricka KB et al (2002) Utility of three-dimensional and multiplanar reformatted computed tomography for evaluation of pediatric congenital spine abnormalities. Spine 27:844–850CrossRefPubMed Newton PO, Hahn GW, Fricka KB et al (2002) Utility of three-dimensional and multiplanar reformatted computed tomography for evaluation of pediatric congenital spine abnormalities. Spine 27:844–850CrossRefPubMed
16.
Zurück zum Zitat Owen BD, Christensen GE, Reinhardt JM, Ryken TC (2007) Rapid prototype patient-specific drill template for cervical pedicle screw placement. Comput Aided Surg 12:303–308CrossRefPubMed Owen BD, Christensen GE, Reinhardt JM, Ryken TC (2007) Rapid prototype patient-specific drill template for cervical pedicle screw placement. Comput Aided Surg 12:303–308CrossRefPubMed
17.
Zurück zum Zitat Polly DW Jr, Potter BK, Kuklo T et al (2004) Volumetric spinal canal intrusion: a comparison between thoracic pedicle screws and thoracic hooks. Spine 29:63–69CrossRefPubMed Polly DW Jr, Potter BK, Kuklo T et al (2004) Volumetric spinal canal intrusion: a comparison between thoracic pedicle screws and thoracic hooks. Spine 29:63–69CrossRefPubMed
18.
Zurück zum Zitat Quadrani P, Pasini A, Mattiolli-Belmonte M et al (2005) High-resolution 3D scaffold model for engineered tissue fabrication using a rapid prototyping technique. Med Biol Eng Comput 43:196–199CrossRefPubMed Quadrani P, Pasini A, Mattiolli-Belmonte M et al (2005) High-resolution 3D scaffold model for engineered tissue fabrication using a rapid prototyping technique. Med Biol Eng Comput 43:196–199CrossRefPubMed
19.
Zurück zum Zitat Ryken TC, Owen BD, Christensen GE, Reinhardt JM (2009) Image-based drill templates for cervical pedicle screw placement. J Neurosurg Spine 10:21–26CrossRefPubMed Ryken TC, Owen BD, Christensen GE, Reinhardt JM (2009) Image-based drill templates for cervical pedicle screw placement. J Neurosurg Spine 10:21–26CrossRefPubMed
20.
Zurück zum Zitat Salako F, Aubin CE, Fortin C et al (2002) Feasibility study of patient-specific surgical templates for the fixation of pedicle screws. Stud Health Technol Inform 88:419–422PubMed Salako F, Aubin CE, Fortin C et al (2002) Feasibility study of patient-specific surgical templates for the fixation of pedicle screws. Stud Health Technol Inform 88:419–422PubMed
21.
Zurück zum Zitat Venuti JM, Imielinska C, Molholt P (2004) New views of male pelvic anatomy: role of computer-generated 3D images. Clin Anat 17:263–271CrossRef Venuti JM, Imielinska C, Molholt P (2004) New views of male pelvic anatomy: role of computer-generated 3D images. Clin Anat 17:263–271CrossRef
22.
Zurück zum Zitat Wang Y, Zhang Y, Zhang X et al (2008) A single posterior approach for multilevel modified vertebral column resection in adults with severe rigid congenital kyphoscoliosis: a retrospective study of 13 cases. Eur Spine J 17:361–372CrossRefPubMed Wang Y, Zhang Y, Zhang X et al (2008) A single posterior approach for multilevel modified vertebral column resection in adults with severe rigid congenital kyphoscoliosis: a retrospective study of 13 cases. Eur Spine J 17:361–372CrossRefPubMed
23.
Zurück zum Zitat Wettergreen MA, Bucklen BS, Sun W, Liebschner MA (2005) Computer-aided tissue engineering of a human vertebral body. Ann Biomed Eng 33:1333–1343CrossRefPubMed Wettergreen MA, Bucklen BS, Sun W, Liebschner MA (2005) Computer-aided tissue engineering of a human vertebral body. Ann Biomed Eng 33:1333–1343CrossRefPubMed
24.
Zurück zum Zitat Wu M, Tinschert J, Augthun M et al (2001) Application of laser measuring, numerical simulation and rapid prototyping to titanium dental castings. Dent Mater 17:102–108CrossRefPubMed Wu M, Tinschert J, Augthun M et al (2001) Application of laser measuring, numerical simulation and rapid prototyping to titanium dental castings. Dent Mater 17:102–108CrossRefPubMed
Metadaten
Titel
Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study
verfasst von
Keya Mao
Yan Wang
Songhua Xiao
Zhengsheng Liu
Yonggang Zhang
Xuesong Zhang
Zheng Wang
Ning Lu
Zhu Shourong
Zhang Xifeng
Cui Geng
Liu Baowei
Publikationsdatum
01.05.2010
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 5/2010
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-010-1359-0

Weitere Artikel der Ausgabe 5/2010

European Spine Journal 5/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.