Skip to main content
Erschienen in: European Spine Journal 10/2011

Open Access 01.10.2011 | Review Article

Effectiveness of interspinous implant surgery in patients with intermittent neurogenic claudication: a systematic review and meta-analysis

verfasst von: Wouter A. Moojen, Mark P. Arts, Ronald H. M. A. Bartels, Wilco C. H. Jacobs, Wilco C. Peul

Erschienen in: European Spine Journal | Ausgabe 10/2011

Abstract

Introduction

Despite an increasing implantation rate of interspinous process distraction (IPD) devices in the treatment of intermittent neurogenic claudication (INC), definitive evidence on the clinical effectiveness of implants is lacking. The main objective of this review was to perform a meta-analysis of all systematic reviews, randomized clinical trials and prospective cohort series to quantify the effectiveness of IPDs and to evaluate the potential side-effects.

Methods

Data from all studies prospectively describing clinical results based on validated outcome scales and reporting complications of treatment of patients with INC with IPD placement. We searched MEDLINE, EMBASE, Web of Science, Cochrane (CENTRAL), CINAHL, Academic Search Premier, Science Direct up to July 2010. Studies describing patients with INC caused by lumbar stenosis, reporting complication rate and reporting based on validated outcome scores, were eligible. Studies with only instrumented IPD results were excluded.

Results

Eleven studies eligible studies were identified. Two independently RCTs and eight prospective cohorts were available. In total 563 patients were treated with IPDs. All studies showed improvement in validated outcome scores after 6 weeks and 1 year. Pooled data based on the Zurich Claudication Questionnaire of the RCTs were more in favor of IPD treatment compared with conservative treatment (pooled estimate 23.2, SD 18.5–27.8). Statistical heterogeneity after pooled data was low (I-squared 0.0, p = 0.930). Overall complication rate was 7%.

Conclusion

As the evidence is relatively low and the costs are high, more thorough (cost-) effectiveness studies should be performed before worldwide implementation is introduced.

Introduction

Intermittent neurogenic claudication (INC) is a complex of symptoms, the most important being leg pain and numbness (frequently in both legs) with possibly associated back pain [14]. The symptoms can be diminished by flexion of the lumbar spine [58]. Lumbar spinal arthrosis inducing arthrosis of the facet is associated with INC [8, 9]. Traditionally, bony decompression of the canal and the lateral recessus seems to be the golden standard in the treatment of INC [3, 4]. There is some evidence that bony decompression is a proven superior therapy compared with non-surgical therapy, such as steroid injections or physiotherapy [10, 11]. Less invasive strategies have been developed to minimize the perioperative damage, such as unilateral laminotomy or endoscopic procedures [12]. Although surgery is frequently offered, detailed outcome results are not available and spine surgeons try to develop innovative less invasive surgical approaches to gain better outcome than the results observed in daily practice.
Parallel to these developments, interspinous implants for interspinous process distraction devices (IPD) have been developed to achieve indirect decompression [13, 14]. The design of the implants aims at limitation of lumbar extension and increasing the interlaminar space of the affected level [1519]. Nowadays, the technique is widely used. Kyphon Inc. had a worldwide X-STOP net sale, in the first quarter of 2007, of 18.1 million USD. Paradigm Spine Inc. reported in May 2010 a worldwide sale of 13,128 Coflex devices in 2009 [20]. The existing evidence seems to be poor; almost no comparative studies between conventional surgical decompression and surgery with IPD are done [17, 2124]. Some claim, performing IPD placement in day surgery and with local anesthesia will lower the costs. However, a thorough cost-analysis has never been performed.
The main objective of this systematic review was to evaluate if surgery with IPD is more effective compared with bony decompression in the treatment of patients with INC or at least more effective compared with conservative (e.g. steroid injections) treatment.

Methods

This systematic review was performed according to the Cochrane systematic review methodology, up-dated by Furlan and Van Tulder and the Meta-analysis of Observational Studies in Epidemiology (MOOSE) criteria [2527].

Search strategies

On July 1, 2010, a search of relevant systematic reviews on IPD in the Cochrane Library and, in addition, observational cohort studies (with and without control group), systematic reviews and randomized clinical trials was conducted in MEDLINE, EMBASE, Web of Science, Cochrane (CENTRAL), CINAHL, Academic Search Premier, Science Direct. Keywords used for the search were: interspinous implant surgery, interspinous implants, interspinous distraction devices, interspinous decompression device, interspinous process decompression, intermittent neurogenic claudication, neurogenic claudication, lumbar stenosis, or spinal stenosis. The full search strategy is available upon request from the corresponding author. References of retrieved articles and relevant overview articles were checked to identify additional studies.

Inclusion criteria

Prospective cohort studies, systematic reviews and/or RCTs written in English were considered eligible for inclusion if they fulfilled all of the following:
1.
The study population consists of patients with INC caused by lumbar stenosis.
 
2.
Patients with INC without or with degenerative spondylolisthesis to a maximal grade I.
 
3.
One of the treatments consists of non-instrumented IPD for treating symptoms of INC (excluding pedicle screw fixations combined with IPD).
 
4.
A validated outcome score is used to evaluate the outcome after surgery, the Zurich Claudication Questionnaire or the Modified Roland Disability Questionnaire for Sciatica, Oswestry Disability Index, VAS leg and back pain [2839].
 
Studies, in which subgroups met our inclusion criteria, were included in our results if the results for these subpopulations were reported separately.

Study selection

Two reviewers independently applied the inclusion criteria to select potential relevant studies from the titles and abstracts or if necessary the complete publication of the references retrieved by the literature search. Where necessary, a third reviewer was consulted to resolve a disagreement.

Categorization of the relevant literature

Relevant literature was categorized under three different headers: systematic reviews, RCTs, and prospective cohort studies of high quality. The header ‘systematic reviews’ describes all systematic reviews. The header ‘RCTs’ contains all published RCTs on the same intervention comparing IPD with decompression or conservative treatment. Additional prognostic cohort studies were included. The header ‘observational cohort studies’ contains all prospective cohorts with adequate description of the follow-up period and validated outcome measurements. When, due to lack of evidence, pooling data was not possible a descriptive review would be performed based on RCTs and prospective observational cohort studies.

Methodological quality assessment

Systematic reviews were validated using the steps defined by Furlan and Van Tulder [27, 40]. To identify potential risks of bias of the included RCTs two reviewers independently assessed the methodological quality of each RCT according to the Cochrane quality measurements adapted by Furlan and Van Tulder [25, 27, 41, 42]. Each item was scored as “yes”, “no”, or “don’t’ know”. High quality was defined as a score of 50% or more on the methodological quality assessment. The Dutch Cochrane Centre Quality Assessment (DCCQA) scale was used for the validation process for observational studies. According to the Dutch Cochrane Centre Quality Assessment scale, a score below six was defined as low methodological quality on the DCCQA scale. A third reviewer could be consulted to solve disagreement between the reviewers.

Data extraction

Independently, data were extracted by two reviewers. Information was collected on the study population, intervention(s) performed, outcome measures and outcome. The follow-up time was categorized into short-term outcome (6 weeks after intervention) and long-term outcome (at least 1 year). Furthermore, complication rate and device failure (a re-intervention or other surgical technique was necessary) were recorded. Despite the often mentioned spinal process fractures, all other causes for surgical re-interventions were also recorded [4346].

Outcome measurements

There are various classifications to describe neurological and functional outcome of patients with intermittent neurogenic claudication. Articles were filtered on presence of one of the four mostly used outcome scales. Firstly, articles were included on the Zurich Claudication Questionnaire (ZCQ), also known as the Brigham Spinal Stenosis Questionnaire and Swiss Spinal Stenosis Questionnaire [35, 38, 39]. The ZCQ scale consists of three subscales: symptom severity, physical function and patient satisfaction. Domain scores ranges from 1 to 5, 1 to 4, and 1 to 4, respectively. Like in the study of Tuli in 2006, we chose threshold scores for each scale based on prior work [35, 38, 39, 47]. In the symptom severity scale and in the physical function scale the minimal clinically important difference (MCID) is 0.5 [38, 39]. A mean patient satisfaction score of less than 2.5 has been shown previously to represent a satisfied patient [38, 39]. Secondly, articles were used on the Modified Roland Disability Questionnaire for Sciatica (MRDQ). The 23-points MRDQ is the most widely used patient-assessed measure of health for low back pain and leg pain [2934, 36]. This questionnaire consists of 23 questions with higher scores indicating increased disability [48]. The Visual Analog Scale (VAS) is one of the most used follow-up measurement tools for back pain and leg pain [49]. This parameter will measure the experienced back and leg pain intensity in the week before visiting the research nurse. Pain will be assessed on a horizontal 100 mm scale varying from 0 mm, “no pain”, to 100 mm, “the worst pain imaginable” [49]. This parameter has a MCID of two points on a scale of 0 to 10 [50]. Finally, the Oswestry disability index (ODI), where 0 indicates no disability and 100 indicates worst possible disability, was included for our analysis [51]. This parameter has a MCID of 10.0–12.4 points [50, 52, 53].

Data synthesis

A meta-analysis was performed if two or more RCTs were available with clinical homogeneous patient groups and statistical homogeneous results. When not possible, due to small amount of studies or heterogeneity, a best-evidence synthesis was used. Best-evidence synthesis was performed stratified for studies meeting 50% or more opposed to those meeting less than 50% of the quality criteria of the Van Tulder list [27]. The study was only included in the best-evidence synthesis if a comparison was made between the groups (IPD placement vs. conservative treatment or IPD placement vs. surgical decompressive treatment). When meta-analysis or best-evidence synthesis based on RCT is not possible, a data extraction based on observational studies (with or without control group) will be performed. Although a high risk of bias is possible, if possible we performed a data extraction from observational studies based on the “best-of-the-rest” principle.

Results

Study selection

The search revealed 253 references. 222 articles were excluded on the basis of the abstract, title and keywords. 20 articles were excluded after reading the complete articles because of the following reasons: the reports did not consist original patient data (4) [17, 23, 54, 55], articles were not written in English (2) [56, 57], there were no outcome results given (9) [24, 5865], studies with a retrospective study design (5) [43, 6669]. As a result, only three RCTs and eight prospective cohorts were included for methodological quality assessment in this review (Fig. 1, Flowchart) [17, 2123, 7076].

Description of study characteristics

No systematic reviews could be found. Three reports of randomized clinical trials (RCTs) and eight prospective cohorts were found. Three reports described two RCTs comparing non-operative treatment to treatment with IPD; one observational cohort described IPD treatment versus non-operative treatment after bony decompression in both groups; seven cohorts described treatment with IPD only. Two RCTs described the results of the same patient sample. The first study published follow-up data after 1 year and the last published study after 2 years, both are shown in Table 1 [17, 23].
Table 1
RCT validation according to Van Tulder validation scale
  
Adequate randomization
Allocation concealment
Baseline comparability
Blinding of patient
Blinding of care provider
Blinding outcome assessor
Cointerventions were avoided
Acceptable compliance between groups
Drop-out rate is described
Similar timing of outcome assessment
Intention-to-treat analysis
Overall quality (max 11)
1
Anderson PA
No
No
Yes
No
No
Don’t know
Yes
Yes
Yes
Yes
Yes
6
2
Zucherman JF 2004
No
No
Yes
No
No
Don’t know
Yes
Yes
Yes
Yes
Don’t know
5
3
Zucherman JF 2004
No
No
Yes
No
No
Don’t know
Yes
Yes
Yes
Yes
Don’t know
5
Max maximal points available

Methodological quality assessment

The methodological quality of the studies is summarized in Tables 1 and 2. Two reports of one RCT (of the three RCTs) had a methodological quality score of 5 (low quality) and one RCT had a quality of 6 (a high quality study) according to the Furlan and Van Tulder criteria [25, 27]. Only one observational study had a methodological quality of 6 out of 8 (reflecting high quality) [76], thus the remaining 7 observational studies are of low methodological quality and with high risk of bias [22, 7075].
Table 2
Prospective cohort validation according to Dutch Cochrane validation scale
  
Patients defined
Absence of selection bias
Treatment defined
Appropriate outcome measurements
Blinded outcome
Sufficient follow-up time
No selective loss to follow-up
Groups comparable confounding factors
Overall quality (max 8)
1
Bhadra AK
+
+
+
+
+
5
2
Brussee P
+
+
+
+
4
3
Galarza M
+
+
+
3
4
Kuchta J
+
+
+
+
+
5
5
Lee J
+
+
+
+
4
6
Richter
+
+
+
+
4
7
Siddiqui M
+
+
+
+
4
8
Yano S
+
+
+
+
+
+
6
Max maximal points available

Data extraction

In Tables 3, 4 and 5, relevant data on the selected studies is shown with the baseline and postoperative follow-up scores at 6 weeks and 1 year. Two RCTs with different patients samples (the two RCTs of Zucherman were conducted on the same patient sample), Anderson et al. and Zucherman et al. [17, 21], could be used for best evidence synthesis. Both RCTs compared conservative treatment with IPD placement (Fig. 2, meta-analysis). Both studies measured follow-up data on the ZCQ. In the study by Zucherman et al., however, overall success rates and standard deviation (SD) values were not shown. A calculation was made, based on the ZCQ values of symptom severity and physical function ZCQ. SD values were calculated estimated from the SD values of Anderson et al. Both studies favored treatment with IPD placement, pooled ZCQ improvement by 23.2 (SD 18.5–27.8). Statistical heterogeneity after pooled data was low (I-squared 0.0, p = 0.930). According to the statistical heterogeneity, baseline criteria in both studies showed a good clinical homogeneity. Richter et al. [22] compared two surgical decompression cohorts: one group with surgical decompression and no IPD placement, one group with surgical decompression with IPD placement. Both groups showed clinical improvement in the ODI, MRDQ and VAS. At 6 weeks and at 1 year follow-up there were no statistical significantly differences between both groups. The remaining seven prospective cohort studies showed improvement from baseline after treatment with IPD [7076]. However, these groups did not compare other treatment modalities (such as conservative treatment) with IPD follow-up results. Due to the use of multiple follow-up scales, pooling of data was not possible (Tables 4, 5, prospective cohort studies).
Table 3
RCTs—outcome measurements and complications
RCT
Sample size
Control sample size
FU
Age (years)
ZCQ baseline IPD (SD)
ZCQ baseline control (SD)
ZCQ short-term IPD (%)
ZCQ short-term control (%)
ZCQ 1 year term IPD (SD)
ZCQ 1 year term control (SD)
Complications (%)
Device failure (%)
Anderson PA
42
33
99/92
71.4/68.5
50.40 (±2.04)
51.26 (±2.39)
46a
27a
23.05a (±3.14)
47.40a (±3.18)
2
2
Zucherman JF
100
91
88/68
69.9/68.6
SS 3.14
SS 3.12
47
10
45.4%
7.4%
2
6
     
PF 2.48
PF 2.49
50
10
44.3%
−0.4%
  
      
Overall success
52a
10a
48.4%a
4.9%a
  
Age patients’ age in years, FU complete follow-up, ZCQ Zurich Claudication Questionnaire, SS ZCQ symptom severity domain, PF ZCQ physical function domain
aValues of ZCQ overall success domain
Table 4
Prospective cohorts comparing conservative treatment with surgery with IPD—outcome measurements and complications
 
Sample size
Device
FU (%)
Age
Follow-up
VAS baseline
VAS follow-up
ODI baseline
ODI follow-up 1
ODI follow-up 2
ZCQ baseline SS/PF
ZCQ follow-up 1 SS/PF/PS
ZCQ follow-up 2 SS/PF/PS
Complications (%)
Device failure (%)
Bhadra AK
45
X-Stop
100
61.5
 
69
28
42
16
    
4
2
Brussee P
65
X-Stop
95
64.4
         
0
9
Galarza M
40
Aperius
100
72.7
1 year
71
22
    
90%
   
Kuchta J
175
X-Stop
100
69.4
6 weeks/1 year
61
39
33
23
15
   
0
5
Lee J
10
X-Stop
100
71.0
9–18 months
      
50%
 
0
 
Siddiqui M
37
X-Stop
65
71.5
3 months/1 year
  
48
35
37
3.37/2.45
2.42/2.05/1.90
2.83/2.19/2.12
0
11
Yano S
19
Ceramic
95
70.1
Mean 37.4 months
69
30
   
2.94/2.51
1.92/1.73
 
0
11
Age patients’ age in years, FU complete follow-up, Follow-up follow-up periods, ZCQ Zurich Claudication Questionnaire, ODI Oswestry Disability Index, VAS Visual Analog Scale, SS ZCQ symptom severity domain, PF ZCQ physical function domain, PS ZCQ patient satisfaction domain
Table 5
Prospective cohorts comparing decompressive surgery with decompressive surgery combining IPD—Outcome measurements and complications
 
Sample size
Device
Control sample
FU (%)
Age
Follow-up
VAS baseline
VAS follow-up 1
VAS follow-up 2
ODI baseline
ODI follow-up 1
ODI follow-up 2
Complications (%)
Device failure (%)
Richter
30
Coflex
30
100
68.0
3 months/1 year
63
25
22
48
23
18
3
10
Age patients’ age in years, FU complete follow-up, Follow-up follow-up periods, ODI Oswestry Disability Index, VAS Visual Analog Scale
In our search of literature, 563 patients underwent implantation with IPD. Complication rates and device failure rates were available from 513 patients (Table 3, RCT, Tables 4, 5, prospective cohorts). A total of 31 devices failed (6%) and had to be replaced or were re-operated with bony decompression and stabilization. Six (1%) other complications were also reported (infections and postoperative leakages).

Discussion

The literature has been systematically reviewed to evaluate the outcome for patients with intermittent neurogenic claudication treated with IPD versus bony decompression or conservative non-surgical treatment. To our knowledge, this is the first systematic review and meta-analysis on this subject. After a literature search, two independent RCTs and eight prospective cohorts, one with a control group, were eligible for validation and data extraction. The methodological quality of the RCTs were 5 (Zucherman) and 6 (Anderson) [17, 21]. The methodological quality of the remaining prospective cohort studies was relatively low (only one reached 6 out of 8) [22, 7076]. In total 563 patients were treated with IPD. All studies showed improvement in validated outcome scores after 6 weeks and 1 year. Pooled data of the RCTs were more in favor of IPD treatment compared with conservative treatment.
The review of the literature showed that very little is known about treatment with IPD. Only one comparative study with good methodological quality fulfilling our selection criteria was found [21]. Different indications are used for these devices, such as described by Richter who used an IPD in combination with surgical decompression [22]. Some studies show beneficial effect of surgical technique compared to conservative treatment for patients with degenerative lumbar spinal stenosis and neurogenic intermittent claudication [10, 11]. More centers, however, perform complex techniques rather than only a decompression technique. Between 2002 and 2007, complex fusion procedures showed a 15-fold increase in the USA. Furthermore, the overall procedure rate slightly decreased with 1.4% [7779]. Coflex worldwide implants increased from 1,717 in 2005 to 13,128 in 2009. Even without evidence of implantation of an IPD as a treatment strategy for INC, some centers use it in a combination with other techniques [22]. Despite the fact that no arguments exist in the literature about the effectiveness of treatment with IPD versus bony decompression, many centers throughout the world use IPD for the treatment of INC.
Overall complication and failure rate of (7%, including 6% reoperations rate after device failure) tended to be relatively low compared to the complication rate of standard bony decompression. For example, Weinstein and Malmivaara [10, 11] reported a complication rate of 17–24% in the standard bony decompression operation cohorts. The most frequently reported complications in these series are dural tears and wrong level surgery. Due to the use of standard X-rays in the operation theater with IPD treatment, wrong level surgery in interspinous decompression surgery is rare. Most techniques of interspinous decompression are indirect and with some distance from the dura, therefore causing a dural tear is difficult by regular surgical methods. Despite the large numbers of case reports on complications after IPD treatment, complication rates tends to be low [43, 44, 80, 81]. This, however, might be induced by selection bias of published studies. Despite the relatively low complication rate, device failure rate needing reoperation is high (6%). This number can be higher because of the publication bias, but also the lack of long-term follow-up. This conclusion is difficult to confirm due to the fact that no comparative studies are done on this subject. Combined with the 6% device failure rate complication rate, the IPD complication rate is 7%. In the literature, implantation surgery is associated with complication rate of 8% (2–6% failure rate) [79]. The complication rate would be possible higher when complications would be monitored 30 days after discharge. Not all studies included in our review reported complication rate 30 days after hospital stay. Prospective reporting of complication should be made standard in future trials.
The most important limitation of this review concerned the methodological weaknesses and selection biases of the included studies: the vast majority was observational, without independent outcome assessment, and without complications well defined. Additionally, we combined two different RCTs for our meta-analysis [17, 21]. Both studies did not mention a thorough power or sample size design, resulting in a 191 patients in one RCT and 75 in the other. Furthermore, only one study was of relatively high methodological quality. Therefore, possible information bias could be introduced. Furthermore we excluded 242 studies, introducing selection bias. Due to the retrospective design of some of these studies, possible interesting patient data had to be excluded. Studies that were published in abstract or poster format only were excluded. The present study was aimed at identifying published peer-reviewed literature, so that influence of publication bias cannot be ruled out. Due to the small number of studies, possible publication bias (using e.g. funnel plot) could not adequately be assessed. Due to the anticipated low number of RCTs, prospective studies were also included. Most of these studies were of low methodological quality (Table 2, Validation). Due to the inclusion of studies of low methodological quality, information bias is easily introduced. Furthermore, methodological quality assessment does not take into account the author’s disclosure. For example, two studies in our review stated that one of the authors is a consultant and, in one article, stockholder of the company manufacturing the IPD device they were using for their study [21, 70]. The remaining studies did not mention any conflict of interest or disclosure. Seven studies did not even describe the possible conflicts of interest. Assessing possible conflict of interest is not incorporated in both validation scales [25, 27]. Standard adjusting both scales based on possible conflict of interest is advisable.
This review of the literature shows that surgical decompression with interspinous process devices is superior to conservative non-surgical treatment in patients with lumbar degenerative spinal stenosis with INC. However, the level of evidence for this conclusion is debatable due to the low quality of some of the included studies. Furthermore, no data is presently available comparing interspinous process decompression with standard bony decompression. We suggest that more studies will be done on this subject comparing the surgical treatment with IPD versus bony decompression. Despite the fact that we could give a Grade A recommendation, according to the Oxford-Centre for Evidence Based Medicine, we suggest that further studies have to be performed before a thorough recommendation can be given regarding the treatment of INC with IPDs [82]. These studies should also include analysis on complication rate and device failure rate. As the evidence is relatively low and the costs are high, more thorough cost-effectiveness studies should be performed before worldwide implementation is introduced. Because the golden standard for surgical decompression seems to be absent, patients with lumbar spinal stenosis should be guarded against instrumented surgery or the use of IPD on the basis of the current evidence.

Acknowledgments

The authors did not receive any funding.

Conflict of interest

The authors have no conflict of interest.

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://​creativecommons.​org/​licenses/​by-nc/​2.​0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Johnsson KE, Uden A, Rosen I (1991) The effect of decompression on the natural course of spinal stenosis. A comparison of surgically treated and untreated patients. Spine (Phila Pa 1976) 16:615–619CrossRef Johnsson KE, Uden A, Rosen I (1991) The effect of decompression on the natural course of spinal stenosis. A comparison of surgically treated and untreated patients. Spine (Phila Pa 1976) 16:615–619CrossRef
2.
Zurück zum Zitat Amundsen T, Weber H, Lilleas F, Nordal HJ, Abdelnoor M, Magnaes B (1995) Lumbar spinal stenosis. Clinical and radiologic features. Spine (Phila Pa 1976) 20:1178–1186CrossRef Amundsen T, Weber H, Lilleas F, Nordal HJ, Abdelnoor M, Magnaes B (1995) Lumbar spinal stenosis. Clinical and radiologic features. Spine (Phila Pa 1976) 20:1178–1186CrossRef
3.
Zurück zum Zitat Gibson JN, Grant IC, Waddell G (1999) The Cochrane review of surgery for lumbar disc prolapse and degenerative lumbar spondylosis. Spine (Phila Pa 1976) 24:1820–1832CrossRef Gibson JN, Grant IC, Waddell G (1999) The Cochrane review of surgery for lumbar disc prolapse and degenerative lumbar spondylosis. Spine (Phila Pa 1976) 24:1820–1832CrossRef
4.
Zurück zum Zitat Gibson JN, Waddell G (2005) Surgery for degenerative lumbar spondylosis: updated Cochrane review. Spine (Phila Pa 1976) 30:2312–2320CrossRef Gibson JN, Waddell G (2005) Surgery for degenerative lumbar spondylosis: updated Cochrane review. Spine (Phila Pa 1976) 30:2312–2320CrossRef
6.
Zurück zum Zitat Verbiest H (1950) Primary stenosis of the lumbar spinal canal in adults, a new syndrome. Ned Tijdschr Geneeskd 94:2415–2433PubMed Verbiest H (1950) Primary stenosis of the lumbar spinal canal in adults, a new syndrome. Ned Tijdschr Geneeskd 94:2415–2433PubMed
7.
Zurück zum Zitat Verbiest H (1951) Further reports on primary stenosis of the lumbar spinal canal in adults. Ned Tijdschr Geneeskd 95:1965–1970PubMed Verbiest H (1951) Further reports on primary stenosis of the lumbar spinal canal in adults. Ned Tijdschr Geneeskd 95:1965–1970PubMed
8.
Zurück zum Zitat Verbiest H (1954) A radicular syndrome from developmental narrowing of the lumbar vertebral canal. J Bone Joint Surg Br 36-B:230–237PubMed Verbiest H (1954) A radicular syndrome from developmental narrowing of the lumbar vertebral canal. J Bone Joint Surg Br 36-B:230–237PubMed
9.
Zurück zum Zitat Arnoldi CC, Brodsky AE, Cauchoix J et al (1976) Lumbar spinal stenosis and nerve root entrapment syndromes. Definition and classification. Clin Orthop Relat Res 115:4–5PubMed Arnoldi CC, Brodsky AE, Cauchoix J et al (1976) Lumbar spinal stenosis and nerve root entrapment syndromes. Definition and classification. Clin Orthop Relat Res 115:4–5PubMed
10.
Zurück zum Zitat Malmivaara A, Slatis P, Heliovaara M et al (2007) Surgical or nonoperative treatment for lumbar spinal stenosis? A randomized controlled trial. Spine (Phila Pa 1976) 32:1–8CrossRef Malmivaara A, Slatis P, Heliovaara M et al (2007) Surgical or nonoperative treatment for lumbar spinal stenosis? A randomized controlled trial. Spine (Phila Pa 1976) 32:1–8CrossRef
11.
Zurück zum Zitat Weinstein JN, Tosteson TD, Lurie JD et al (2008) Surgical versus nonsurgical therapy for lumbar spinal stenosis. N Engl J Med 358:794–810PubMedCrossRef Weinstein JN, Tosteson TD, Lurie JD et al (2008) Surgical versus nonsurgical therapy for lumbar spinal stenosis. N Engl J Med 358:794–810PubMedCrossRef
12.
Zurück zum Zitat Thome C, Zevgaridis D, Leheta O et al (2005) Outcome after less-invasive decompression of lumbar spinal stenosis: a randomized comparison of unilateral laminotomy, bilateral laminotomy, and laminectomy. J Neurosurg Spine 3:129–141PubMedCrossRef Thome C, Zevgaridis D, Leheta O et al (2005) Outcome after less-invasive decompression of lumbar spinal stenosis: a randomized comparison of unilateral laminotomy, bilateral laminotomy, and laminectomy. J Neurosurg Spine 3:129–141PubMedCrossRef
13.
Zurück zum Zitat Mariottini A, Pieri S, Giachi S et al (2005) Preliminary results of a soft novel lumbar intervertebral prothesis (DIAM) in the degenerative spinal pathology. Acta Neurochir Suppl 92:129–131PubMedCrossRef Mariottini A, Pieri S, Giachi S et al (2005) Preliminary results of a soft novel lumbar intervertebral prothesis (DIAM) in the degenerative spinal pathology. Acta Neurochir Suppl 92:129–131PubMedCrossRef
14.
Zurück zum Zitat Tsai KJ, Murakami H, Lowery GL, Hutton WC (2006) A biomechanical evaluation of an interspinous device (Coflex) used to stabilize the lumbar spine. J Surg Orthop Adv 15:167–172PubMed Tsai KJ, Murakami H, Lowery GL, Hutton WC (2006) A biomechanical evaluation of an interspinous device (Coflex) used to stabilize the lumbar spine. J Surg Orthop Adv 15:167–172PubMed
15.
Zurück zum Zitat Simons P, Werner D, Krause P, Mark P, Godde G, Reinhard A (2006) Treatment of neurogenic intermittent claudication (NIC), secondary to lumbar spinal stenosis (LSS), with the COFLEX® Interspinous Process Decompression (IPD) system. Early ZCQ outcome results from the European registry Simons P, Werner D, Krause P, Mark P, Godde G, Reinhard A (2006) Treatment of neurogenic intermittent claudication (NIC), secondary to lumbar spinal stenosis (LSS), with the COFLEX® Interspinous Process Decompression (IPD) system. Early ZCQ outcome results from the European registry
16.
Zurück zum Zitat Wilke HJ, Drumm J, Haussler K, Mack C, Steudel WI, Kettler A (2008) Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure. Eur Spine J 17:1049–1056PubMedCrossRef Wilke HJ, Drumm J, Haussler K, Mack C, Steudel WI, Kettler A (2008) Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure. Eur Spine J 17:1049–1056PubMedCrossRef
17.
Zurück zum Zitat Zucherman JF, Hsu KY, Hartjen CA et al (2004) A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results. Eur Spine J 13:22–31PubMedCrossRef Zucherman JF, Hsu KY, Hartjen CA et al (2004) A prospective randomized multi-center study for the treatment of lumbar spinal stenosis with the X STOP interspinous implant: 1-year results. Eur Spine J 13:22–31PubMedCrossRef
18.
Zurück zum Zitat Siddiqui M, Karadimas E, Nicol M, Smith FW, Wardlaw D (2006) Influence of X Stop on neural foramina and spinal canal area in spinal stenosis. Spine (Phila Pa 1976) 31:2958–2962CrossRef Siddiqui M, Karadimas E, Nicol M, Smith FW, Wardlaw D (2006) Influence of X Stop on neural foramina and spinal canal area in spinal stenosis. Spine (Phila Pa 1976) 31:2958–2962CrossRef
19.
Zurück zum Zitat Siddiqui M, Karadimas E, Nicol M, Smith FW, Wardlaw D (2006) Effects of X-STOP device on sagittal lumbar spine kinematics in spinal stenosis. J Spinal Disord Tech 19:328–333PubMedCrossRef Siddiqui M, Karadimas E, Nicol M, Smith FW, Wardlaw D (2006) Effects of X-STOP device on sagittal lumbar spine kinematics in spinal stenosis. J Spinal Disord Tech 19:328–333PubMedCrossRef
20.
Zurück zum Zitat Sale numbers directly obtained from Kyphon Inc and Paradigm Spine Inc Sale numbers directly obtained from Kyphon Inc and Paradigm Spine Inc
21.
Zurück zum Zitat Anderson PA, Tribus CB, Kitchel SH (2006) Treatment of neurogenic claudication by interspinous decompression: application of the X STOP device in patients with lumbar degenerative spondylolisthesis. J Neurosurg Spine 4:463–471PubMedCrossRef Anderson PA, Tribus CB, Kitchel SH (2006) Treatment of neurogenic claudication by interspinous decompression: application of the X STOP device in patients with lumbar degenerative spondylolisthesis. J Neurosurg Spine 4:463–471PubMedCrossRef
22.
Zurück zum Zitat Richter A, Schutz C, Hauck M, Halm H (2009) Does an interspinous device (Coflex) improve the outcome of decompressive surgery in lumbar spinal stenosis? One-year follow up of a prospective case control study of 60 patients. Eur Spine J 19(2):283–289PubMedCrossRef Richter A, Schutz C, Hauck M, Halm H (2009) Does an interspinous device (Coflex) improve the outcome of decompressive surgery in lumbar spinal stenosis? One-year follow up of a prospective case control study of 60 patients. Eur Spine J 19(2):283–289PubMedCrossRef
23.
Zurück zum Zitat Zucherman JF, Hsu KY, Hartjen CA et al (2005) A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results. Spine (Phila Pa 1976) 30:1351–1358CrossRef Zucherman JF, Hsu KY, Hartjen CA et al (2005) A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results. Spine (Phila Pa 1976) 30:1351–1358CrossRef
24.
Zurück zum Zitat Stromqvist B, Johnsson R, Sahlstrand T, Tullberg T (2007) Comparison of patients with neurogenic intermittent claudication treated with the X-Stop interspinous process decompression system vs decompressive surgery–early follow-up results. Spine J 5:S168CrossRef Stromqvist B, Johnsson R, Sahlstrand T, Tullberg T (2007) Comparison of patients with neurogenic intermittent claudication treated with the X-Stop interspinous process decompression system vs decompressive surgery–early follow-up results. Spine J 5:S168CrossRef
25.
Zurück zum Zitat Furlan JC, Singh J, Hsieh J, Fehlings MG (2010) Methodology of systematic reviews and recommendations. J Neurotrauma [Epub ahead of print] Furlan JC, Singh J, Hsieh J, Fehlings MG (2010) Methodology of systematic reviews and recommendations. J Neurotrauma [Epub ahead of print]
26.
Zurück zum Zitat Stroup DF, Berlin JA, Morton SC et al (2000) Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA 283:2008–2012PubMedCrossRef Stroup DF, Berlin JA, Morton SC et al (2000) Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA 283:2008–2012PubMedCrossRef
27.
Zurück zum Zitat van Tulder M, Furlan A, Bombardier C, Bouter L (2003) Updated method guidelines for systematic reviews in the cochrane collaboration back review group. Spine (Phila Pa 1976) 28:1290–1299 van Tulder M, Furlan A, Bombardier C, Bouter L (2003) Updated method guidelines for systematic reviews in the cochrane collaboration back review group. Spine (Phila Pa 1976) 28:1290–1299
28.
Zurück zum Zitat Deyo RA (1986) Comparative validity of the sickness impact profile and shorter scales for functional assessment in low-back pain. Spine (Phila Pa 1976) 11:951–954CrossRef Deyo RA (1986) Comparative validity of the sickness impact profile and shorter scales for functional assessment in low-back pain. Spine (Phila Pa 1976) 11:951–954CrossRef
29.
Zurück zum Zitat Deyo RA, Diehl AK (1986) Patient satisfaction with medical care for low-back pain. Spine (Phila Pa 1976) 11:28–30CrossRef Deyo RA, Diehl AK (1986) Patient satisfaction with medical care for low-back pain. Spine (Phila Pa 1976) 11:28–30CrossRef
30.
Zurück zum Zitat Deyo RA, Patrick DL (1995) The significance of treatment effects: the clinical perspective. Med Care 33:AS286–AS291PubMed Deyo RA, Patrick DL (1995) The significance of treatment effects: the clinical perspective. Med Care 33:AS286–AS291PubMed
31.
Zurück zum Zitat Hutchinson PJ, Laing RJ, Waran V, Hutchinson E, Hollingworth W (2000) Assessing outcome in lumbar disc surgery using patient completed measures. Br J Neurosurg 14:195–199PubMedCrossRef Hutchinson PJ, Laing RJ, Waran V, Hutchinson E, Hollingworth W (2000) Assessing outcome in lumbar disc surgery using patient completed measures. Br J Neurosurg 14:195–199PubMedCrossRef
32.
Zurück zum Zitat Koes BW, van Tulder MW, Thomas S (2006) Diagnosis and treatment of low back pain. BMJ 332:1430–1434PubMedCrossRef Koes BW, van Tulder MW, Thomas S (2006) Diagnosis and treatment of low back pain. BMJ 332:1430–1434PubMedCrossRef
33.
Zurück zum Zitat Patrick DL, Deyo RA (1989) Generic and disease-specific measures in assessing health status and quality of life. Med Care 27:S217–S232PubMedCrossRef Patrick DL, Deyo RA (1989) Generic and disease-specific measures in assessing health status and quality of life. Med Care 27:S217–S232PubMedCrossRef
34.
Zurück zum Zitat Patrick DL, Deyo RA, Atlas SJ, DE Singer, Chapin A, Keller RB (1995) Assessing health-related quality of life in patients with sciatica. Spine (Phila Pa 1976) 20:1899–1908CrossRef Patrick DL, Deyo RA, Atlas SJ, DE Singer, Chapin A, Keller RB (1995) Assessing health-related quality of life in patients with sciatica. Spine (Phila Pa 1976) 20:1899–1908CrossRef
35.
Zurück zum Zitat Pratt RK, Fairbank JC, Virr A (2002) The reliability of the Shuttle Walking Test, the Swiss Spinal Stenosis Questionnaire, the Oxford Spinal Stenosis Score, and the Oswestry Disability Index in the assessment of patients with lumbar spinal stenosis. Spine (Phila Pa 1976) 27:84–91CrossRef Pratt RK, Fairbank JC, Virr A (2002) The reliability of the Shuttle Walking Test, the Swiss Spinal Stenosis Questionnaire, the Oxford Spinal Stenosis Score, and the Oswestry Disability Index in the assessment of patients with lumbar spinal stenosis. Spine (Phila Pa 1976) 27:84–91CrossRef
36.
Zurück zum Zitat Roland M, Morris R (1983) A study of the natural history of low-back pain. Part II: development of guidelines for trials of treatment in primary care. Spine (Phila Pa 1976) 8:145–150CrossRef Roland M, Morris R (1983) A study of the natural history of low-back pain. Part II: development of guidelines for trials of treatment in primary care. Spine (Phila Pa 1976) 8:145–150CrossRef
37.
Zurück zum Zitat Roland M, Morris R (1983) A study of the natural history of back pain. Part I: development of a reliable and sensitive measure of disability in low-back pain. Spine (Phila Pa 1976) 8:141–144CrossRef Roland M, Morris R (1983) A study of the natural history of back pain. Part I: development of a reliable and sensitive measure of disability in low-back pain. Spine (Phila Pa 1976) 8:141–144CrossRef
38.
Zurück zum Zitat Stucki G, Liang MH, Fossel AH, Katz JN (1995) Relative responsiveness of condition-specific and generic health status measures in degenerative lumbar spinal stenosis. J Clin Epidemiol 48:1369–1378PubMedCrossRef Stucki G, Liang MH, Fossel AH, Katz JN (1995) Relative responsiveness of condition-specific and generic health status measures in degenerative lumbar spinal stenosis. J Clin Epidemiol 48:1369–1378PubMedCrossRef
39.
Zurück zum Zitat Stucki G, Daltroy L, Liang MH, Lipson SJ, Fossel AH, Katz JN (1996) Measurement properties of a self-administered outcome measure in lumbar spinal stenosis. Spine (Phila Pa 1976) 21:796–803CrossRef Stucki G, Daltroy L, Liang MH, Lipson SJ, Fossel AH, Katz JN (1996) Measurement properties of a self-administered outcome measure in lumbar spinal stenosis. Spine (Phila Pa 1976) 21:796–803CrossRef
40.
Zurück zum Zitat Oxman AD, Guyatt GH (1991) Validation of an index of the quality of review articles. J Clin Epidemiol 44:1271–1278PubMedCrossRef Oxman AD, Guyatt GH (1991) Validation of an index of the quality of review articles. J Clin Epidemiol 44:1271–1278PubMedCrossRef
41.
Zurück zum Zitat Verhagen AP, de Vet HC, de Bie RA, Boers M, van den Brandt PA (2001) The art of quality assessment of RCTs included in systematic reviews. J Clin Epidemiol 54:651–654PubMedCrossRef Verhagen AP, de Vet HC, de Bie RA, Boers M, van den Brandt PA (2001) The art of quality assessment of RCTs included in systematic reviews. J Clin Epidemiol 54:651–654PubMedCrossRef
42.
Zurück zum Zitat Furlan AD, Pennick V, Bombardier C, van TM (2009) Updated method guidelines for systematic reviews in the Cochrane Back Review Group. Spine (Phila Pa 1976) 34:1929–1941 Furlan AD, Pennick V, Bombardier C, van TM (2009) Updated method guidelines for systematic reviews in the Cochrane Back Review Group. Spine (Phila Pa 1976) 34:1929–1941
43.
Zurück zum Zitat Barbagallo GM, Olindo G, Corbino L, Albanese V (2009) Analysis of complications in patients treated with the X-Stop interspinous process decompression system: proposal for a novel anatomic scoring system for patient selection and review of the literature. Neurosurgery 65:111–119PubMedCrossRef Barbagallo GM, Olindo G, Corbino L, Albanese V (2009) Analysis of complications in patients treated with the X-Stop interspinous process decompression system: proposal for a novel anatomic scoring system for patient selection and review of the literature. Neurosurgery 65:111–119PubMedCrossRef
44.
Zurück zum Zitat Bowers C, Amini A, Dailey AT, Schmidt MH (2010) Dynamic interspinous process stabilization: review of complications associated with the X-Stop device. Neurosurg Focus 28(6):E8PubMedCrossRef Bowers C, Amini A, Dailey AT, Schmidt MH (2010) Dynamic interspinous process stabilization: review of complications associated with the X-Stop device. Neurosurg Focus 28(6):E8PubMedCrossRef
45.
Zurück zum Zitat La Marca F (2009) Analysis of complications in patients treated with the X-Stop interspinous process decompression system: Proposal for a novel anatomic scoring system for patient selection and review of the literature - Commentary. Neurosurgery 65:120 La Marca F (2009) Analysis of complications in patients treated with the X-Stop interspinous process decompression system: Proposal for a novel anatomic scoring system for patient selection and review of the literature - Commentary. Neurosurgery 65:120
46.
Zurück zum Zitat Resnick DK (2009) Analysis of complications in patients treated with the X-Stop interspinous process decompression system: proposal for a novel anatomic scoring system for patient selection and review of the literature—commentary. Neurosurgery 65:119 Resnick DK (2009) Analysis of complications in patients treated with the X-Stop interspinous process decompression system: proposal for a novel anatomic scoring system for patient selection and review of the literature—commentary. Neurosurgery 65:119
47.
Zurück zum Zitat Tuli SK, Yerby SA, Katz JN (2006) Methodological approaches to developing criteria for improvement in lumbar spinal stenosis surgery. Spine (Phila Pa 1976) 31:1276–1280CrossRef Tuli SK, Yerby SA, Katz JN (2006) Methodological approaches to developing criteria for improvement in lumbar spinal stenosis surgery. Spine (Phila Pa 1976) 31:1276–1280CrossRef
48.
Zurück zum Zitat Schoppink LE, van Tulder MW, Koes BW, Beurskens SA, de Bie RA (1996) Reliability and validity of the Dutch adaptation of the Quebec Back Pain Disability Scale. Phys Ther 76:268–275PubMed Schoppink LE, van Tulder MW, Koes BW, Beurskens SA, de Bie RA (1996) Reliability and validity of the Dutch adaptation of the Quebec Back Pain Disability Scale. Phys Ther 76:268–275PubMed
49.
Zurück zum Zitat Carlsson AM (1983) Assessment of chronic pain I. Aspects of the reliability and validity of the visual analogue scale. Pain 16:87–101PubMedCrossRef Carlsson AM (1983) Assessment of chronic pain I. Aspects of the reliability and validity of the visual analogue scale. Pain 16:87–101PubMedCrossRef
50.
Zurück zum Zitat Phelan EA, Deyo RA, Cherkin DC et al (2001) Helping patients decide about back surgery: a randomized trial of an interactive video program. Spine (Phila Pa 1976) 26:206–211CrossRef Phelan EA, Deyo RA, Cherkin DC et al (2001) Helping patients decide about back surgery: a randomized trial of an interactive video program. Spine (Phila Pa 1976) 26:206–211CrossRef
51.
Zurück zum Zitat Fairbank JC, Couper J, Davies JB, O’Brien JP (1980) The Oswestry low back pain disability questionnaire. Physiotherapy 66:271–273PubMed Fairbank JC, Couper J, Davies JB, O’Brien JP (1980) The Oswestry low back pain disability questionnaire. Physiotherapy 66:271–273PubMed
52.
Zurück zum Zitat Copay AG, Subach BR, Glassman SD, Polly DW Jr, Schuler TC (2007) Understanding the minimum clinically important difference: a review of concepts and methods. Spine J 7:541–546PubMedCrossRef Copay AG, Subach BR, Glassman SD, Polly DW Jr, Schuler TC (2007) Understanding the minimum clinically important difference: a review of concepts and methods. Spine J 7:541–546PubMedCrossRef
53.
Zurück zum Zitat Copay AG, Glassman SD, Subach BR, Berven S, Schuler TC, Carreon LY (2008) Minimum clinically important difference in lumbar spine surgery patients: a choice of methods using the Oswestry Disability Index, Medical Outcomes Study questionnaire Short Form 36, and pain scales. Spine J 8:968–974PubMedCrossRef Copay AG, Glassman SD, Subach BR, Berven S, Schuler TC, Carreon LY (2008) Minimum clinically important difference in lumbar spine surgery patients: a choice of methods using the Oswestry Disability Index, Medical Outcomes Study questionnaire Short Form 36, and pain scales. Spine J 8:968–974PubMedCrossRef
54.
Zurück zum Zitat Hsu KY, Zucherman JF, Hartjen CA et al (2006) Quality of life of lumbar stenosis-treated patients in whom the X STOP interspinous device was implanted. J Neurosurg Spine 5:500–507PubMedCrossRef Hsu KY, Zucherman JF, Hartjen CA et al (2006) Quality of life of lumbar stenosis-treated patients in whom the X STOP interspinous device was implanted. J Neurosurg Spine 5:500–507PubMedCrossRef
55.
Zurück zum Zitat Kondrashov DG, Hannibal M, Hsu KY, Zucherman JF (2006) Interspinous process decompression with the X-STOP device for lumbar spinal stenosis: a 4-year follow-up study. J Spinal Disord Tech 19:323–327PubMedCrossRef Kondrashov DG, Hannibal M, Hsu KY, Zucherman JF (2006) Interspinous process decompression with the X-STOP device for lumbar spinal stenosis: a 4-year follow-up study. J Spinal Disord Tech 19:323–327PubMedCrossRef
56.
Zurück zum Zitat Collignon F, Fransen P (2010) Treatment of symptomatic degenerative lumbar spinal stenosis by a percutaneous stand-alone lumbar interspinous implant. Preliminary experience with the Aperius device. Neurochirurgie 56:3–7PubMedCrossRef Collignon F, Fransen P (2010) Treatment of symptomatic degenerative lumbar spinal stenosis by a percutaneous stand-alone lumbar interspinous implant. Preliminary experience with the Aperius device. Neurochirurgie 56:3–7PubMedCrossRef
57.
Zurück zum Zitat Hrabalek L, Machac J, Vaverka M (2009) The DIAM spinal stabilisation system to treat degenerative disease of the lumbosacral spine. Acta Chir Orthop Traumatol Cech 76:417–423PubMed Hrabalek L, Machac J, Vaverka M (2009) The DIAM spinal stabilisation system to treat degenerative disease of the lumbosacral spine. Acta Chir Orthop Traumatol Cech 76:417–423PubMed
58.
Zurück zum Zitat Hsu K, Zucherman J, Hartjen C et al (2004) Interspinous process decompression (IPD) significantly improves symptom severity in neurogenic intermittent claudication patients. Spine J 4:S60CrossRef Hsu K, Zucherman J, Hartjen C et al (2004) Interspinous process decompression (IPD) significantly improves symptom severity in neurogenic intermittent claudication patients. Spine J 4:S60CrossRef
59.
Zurück zum Zitat Implicito D, Martin M, Ozuna R (2007) Outcomes of neurogenic intermittent claudication patients treated with interspinous decompression as a function of number of levels treated. Spine J 5:S90CrossRef Implicito D, Martin M, Ozuna R (2007) Outcomes of neurogenic intermittent claudication patients treated with interspinous decompression as a function of number of levels treated. Spine J 5:S90CrossRef
60.
Zurück zum Zitat Kondrashov D, Hannibal M, Hsu K, Zucherman J (2006) The X STOP interspinous process decompression versus laminectomy for treatment of lumbar spinal stenosis: economic analysis. Neurosurgery 59:458CrossRef Kondrashov D, Hannibal M, Hsu K, Zucherman J (2006) The X STOP interspinous process decompression versus laminectomy for treatment of lumbar spinal stenosis: economic analysis. Neurosurgery 59:458CrossRef
61.
Zurück zum Zitat Skidmore G, Ackerman S, Bergin C et al (2009) Cost-effectiveness of interspinous process decompression for lumbar spinal stenosis: a comparison with conservative care and laminectomy. Spine J 7:95SCrossRef Skidmore G, Ackerman S, Bergin C et al (2009) Cost-effectiveness of interspinous process decompression for lumbar spinal stenosis: a comparison with conservative care and laminectomy. Spine J 7:95SCrossRef
62.
Zurück zum Zitat Zucherman J, Hsu K, Hartjen C et al (2004) A prospective randomized multicenter study of lumbar neurogenic intermittent claudication patients treated conservatively with a laminectomy or with interspinous process decompression. The Spine Journal 4:S33–S34CrossRef Zucherman J, Hsu K, Hartjen C et al (2004) A prospective randomized multicenter study of lumbar neurogenic intermittent claudication patients treated conservatively with a laminectomy or with interspinous process decompression. The Spine Journal 4:S33–S34CrossRef
63.
Zurück zum Zitat Zucherman J, Hsu K, Wahlig J, Hartjen C, Shabe P, Tillman J (2009) Five year outcomes in patients treated with the X-STOP interspinous process device for neurogenic intermittent claudication due to lumbar spinal stenosis. Spine J 8:153SCrossRef Zucherman J, Hsu K, Wahlig J, Hartjen C, Shabe P, Tillman J (2009) Five year outcomes in patients treated with the X-STOP interspinous process device for neurogenic intermittent claudication due to lumbar spinal stenosis. Spine J 8:153SCrossRef
64.
Zurück zum Zitat Eichholz KM, Fessler RG (2006) Is the X STOP interspinous implant a safe and effective treatment for neurogenic intermittent claudication? Nat Clin Pract Neurol 2:22–23PubMedCrossRef Eichholz KM, Fessler RG (2006) Is the X STOP interspinous implant a safe and effective treatment for neurogenic intermittent claudication? Nat Clin Pract Neurol 2:22–23PubMedCrossRef
65.
Zurück zum Zitat Weiner BK, Zucherman JF, Hsu KY, Hartjen CA. A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: Two-year follow-up results. Spine 2005; 30:1351–1358, 2846–2847 Weiner BK, Zucherman JF, Hsu KY, Hartjen CA. A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: Two-year follow-up results. Spine 2005; 30:1351–1358, 2846–2847
66.
Zurück zum Zitat Errico TJ, Kamerlink JR, Quirno M, Samani J, Chomiak RJ (2009) Survivorship of coflex Interlaminar-Interspinous Implant. SAS J 3:59–67CrossRef Errico TJ, Kamerlink JR, Quirno M, Samani J, Chomiak RJ (2009) Survivorship of coflex Interlaminar-Interspinous Implant. SAS J 3:59–67CrossRef
67.
Zurück zum Zitat Nardi P, Cabezas D, Rea G, Pettorini BL (2010) Aperius PercLID stand alone interspinous system for the treatment of degenerative lumbar stenosis: experience on 152 cases. J Spinal Disord Tech 23(3):203–207PubMedCrossRef Nardi P, Cabezas D, Rea G, Pettorini BL (2010) Aperius PercLID stand alone interspinous system for the treatment of degenerative lumbar stenosis: experience on 152 cases. J Spinal Disord Tech 23(3):203–207PubMedCrossRef
68.
Zurück zum Zitat Senegas J, Vital JM, Pointillart V, Mangione P (2009) Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis system) with a 13-year mean follow-up. Neurosurg Rev 32:335–341PubMedCrossRef Senegas J, Vital JM, Pointillart V, Mangione P (2009) Clinical evaluation of a lumbar interspinous dynamic stabilization device (the Wallis system) with a 13-year mean follow-up. Neurosurg Rev 32:335–341PubMedCrossRef
69.
Zurück zum Zitat Verhoof OJ, Bron JL, Wapstra FH, van Royen BJ (2008) High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis. Eur Spine J 17:188–192PubMedCrossRef Verhoof OJ, Bron JL, Wapstra FH, van Royen BJ (2008) High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis. Eur Spine J 17:188–192PubMedCrossRef
70.
Zurück zum Zitat Bhadra AK, Raman AS, Tucker S, Noordeen HH (2008) Interspinous implant in lumbar spinal stenosis: a prospective cohort. Eur J Orthop Surg Traumatol 18:489–493CrossRef Bhadra AK, Raman AS, Tucker S, Noordeen HH (2008) Interspinous implant in lumbar spinal stenosis: a prospective cohort. Eur J Orthop Surg Traumatol 18:489–493CrossRef
71.
Zurück zum Zitat Brussee P, Hauth J, Donk RD, Verbeek AL, Bartels RH (2008) Self-rated evaluation of outcome of the implantation of interspinous process distraction (X-Stop) for neurogenic claudication. Eur Spine J 17:200–203PubMedCrossRef Brussee P, Hauth J, Donk RD, Verbeek AL, Bartels RH (2008) Self-rated evaluation of outcome of the implantation of interspinous process distraction (X-Stop) for neurogenic claudication. Eur Spine J 17:200–203PubMedCrossRef
72.
Zurück zum Zitat Galarza M, Fabrizi AP, Maina R, Gazzeri R, Martinez-Lage JF (2010) Degenerative lumbar spinal stenosis with neurogenic intermittent claudication and treatment with the Aperius PercLID System: a preliminary report. Neurosurg Focus 28(6):E3PubMedCrossRef Galarza M, Fabrizi AP, Maina R, Gazzeri R, Martinez-Lage JF (2010) Degenerative lumbar spinal stenosis with neurogenic intermittent claudication and treatment with the Aperius PercLID System: a preliminary report. Neurosurg Focus 28(6):E3PubMedCrossRef
73.
Zurück zum Zitat Kuchta J, Sobottke R, Eysel P, Simons P (2009) Two-year results of interspinous spacer (X-Stop) implantation in 175 patients with neurologic intermittent claudication due to lumbar spinal stenosis. Eur Spine J 18:823–829PubMedCrossRef Kuchta J, Sobottke R, Eysel P, Simons P (2009) Two-year results of interspinous spacer (X-Stop) implantation in 175 patients with neurologic intermittent claudication due to lumbar spinal stenosis. Eur Spine J 18:823–829PubMedCrossRef
74.
Zurück zum Zitat Lee J, Hida K, Seki T, Iwasaki Y, Minoru A (2004) An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients: preliminary experiences in 10 consecutive cases. J Spinal Disord Tech 17:72–77PubMedCrossRef Lee J, Hida K, Seki T, Iwasaki Y, Minoru A (2004) An interspinous process distractor (X STOP) for lumbar spinal stenosis in elderly patients: preliminary experiences in 10 consecutive cases. J Spinal Disord Tech 17:72–77PubMedCrossRef
75.
Zurück zum Zitat Siddiqui M, Smith FW, Wardlaw D (2007) One-year results of X Stop interspinous implant for the treatment of lumbar spinal stenosis. Spine (Phila Pa 1976) 32:1345–1348CrossRef Siddiqui M, Smith FW, Wardlaw D (2007) One-year results of X Stop interspinous implant for the treatment of lumbar spinal stenosis. Spine (Phila Pa 1976) 32:1345–1348CrossRef
76.
Zurück zum Zitat Yano S, Hida K, Seki T, Aoyama T, Akino M, Iwasaki Y (2008) A new ceramic interspinous process spacer for lumbar spinal canal stenosis. Neurosurgery 63:ONS108–ONS113 Yano S, Hida K, Seki T, Aoyama T, Akino M, Iwasaki Y (2008) A new ceramic interspinous process spacer for lumbar spinal canal stenosis. Neurosurgery 63:ONS108–ONS113
77.
Zurück zum Zitat Carragee EJ (2010) The increasing morbidity of elective spinal stenosis surgery: is it necessary? JAMA 303:1309–1310PubMedCrossRef Carragee EJ (2010) The increasing morbidity of elective spinal stenosis surgery: is it necessary? JAMA 303:1309–1310PubMedCrossRef
78.
Zurück zum Zitat Deyo RA, Gray DT, Kreuter W, Mirza S, Martin BI (2005) United States trends in lumbar fusion surgery for degenerative conditions. Spine (Phila Pa 1976) 30:1441–1445CrossRef Deyo RA, Gray DT, Kreuter W, Mirza S, Martin BI (2005) United States trends in lumbar fusion surgery for degenerative conditions. Spine (Phila Pa 1976) 30:1441–1445CrossRef
79.
Zurück zum Zitat Deyo RA, Mirza SK, Martin BI, Kreuter W, Goodman DC, Jarvik JG (2010) Trends, major medical complications, and charges associated with surgery for lumbar spinal stenosis in older adults. JAMA 303:1259–1265PubMedCrossRef Deyo RA, Mirza SK, Martin BI, Kreuter W, Goodman DC, Jarvik JG (2010) Trends, major medical complications, and charges associated with surgery for lumbar spinal stenosis in older adults. JAMA 303:1259–1265PubMedCrossRef
80.
Zurück zum Zitat Barbagallo GM, Corbino LA, Olindo G, Foti P, Albanese V, Signorelli F (2010) The “sandwich phenomenon”: a rare complication in adjacent, double-level X-stop surgery: report of three cases and review of the literature. Spine (Phila Pa 1976) 35:E96–E100CrossRef Barbagallo GM, Corbino LA, Olindo G, Foti P, Albanese V, Signorelli F (2010) The “sandwich phenomenon”: a rare complication in adjacent, double-level X-stop surgery: report of three cases and review of the literature. Spine (Phila Pa 1976) 35:E96–E100CrossRef
82.
Zurück zum Zitat Phillips B, Ball C, Sackett DL et al (1998) Levels of evidence and grades of recommendation. Centre for Evidence-Based Medicine: Oxford-Centre for Evidence Based Medicine Phillips B, Ball C, Sackett DL et al (1998) Levels of evidence and grades of recommendation. Centre for Evidence-Based Medicine: Oxford-Centre for Evidence Based Medicine
Metadaten
Titel
Effectiveness of interspinous implant surgery in patients with intermittent neurogenic claudication: a systematic review and meta-analysis
verfasst von
Wouter A. Moojen
Mark P. Arts
Ronald H. M. A. Bartels
Wilco C. H. Jacobs
Wilco C. Peul
Publikationsdatum
01.10.2011
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 10/2011
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1873-8

Weitere Artikel der Ausgabe 10/2011

European Spine Journal 10/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.