Skip to main content
Erschienen in: European Spine Journal 9/2012

01.09.2012 | Original Article

Parameters of lengthened sacroiliac screw fixation: a radiological anatomy study

verfasst von: Yong Zhao, Jianmin Li, Dan Wang, Wei Lian

Erschienen in: European Spine Journal | Ausgabe 9/2012

Einloggen, um Zugang zu erhalten

Abstract

Objective

To provide the anatomical basis for the feasibility and clinical practice of lengthened sacroiliac screw fixation, by measuring various related indicators of the safe insertion regions of S1 and S2 lengthened sacroiliac screws.

Methods

A total of 66 healthy pelvises of adults were scanned by 64-slice spiral CT and the length, width and height of the safe insertion regions for S1 and S2 lengthened sacroiliac screw were measured. The safe screw entrance point locations were described with a quantitative method. The indicators were recorded by descriptive statistics and the statistics of left and right sides, segments of S1 and S2, and different layers (including top, middle and bottom parts) of S1 and S2 were compared.

Results

The lengths of ilium within the safe insertion regions for lengthened screws are more than 16 mm. The width and height of the safe insertion region of S1 and S2 are almost all more than 7.3 mm. Generally, the width and height of S1 are larger than those of S2. The reference ranges of the best/safest entrance point locations of lengthened sacroiliac screws are as follows—S1: 42.21–63.69 mm in front of posterior superior iliac spine, 32.77–53.75 mm above the highest point of the greater sciatic notch; S2: 22.68–54.28 mm in front of posterior superior iliac spine, 14.06–33.70 mm above the highest point of the greater sciatic notch.

Conclusion

(1) There is anatomical feasibility for the placements of S1 and S2 lengthened sacroiliac screws. (2) φ 7.3-mm partial thread cannulated screw (thread length 16 mm) and φ 6.5-mm partial thread cancellous screw(thread length 16 mm) can be used as lengthened sacroiliac lag screw. (3) The safe insertion space of S1 is larger than that of S2. (4) There is safe space for placement of at least one piece of lengthened sacroiliac screw in both S1 and S2. (5) The best/safest entrance points of S1 and S2 can be approximately located with anatomical landmarks.
Literatur
1.
Zurück zum Zitat Beaule′ PE, Antoniades J, Matta JM (2006) Trans-sacral fixation for failed posterior fixation of the pelvic ring. Arch Orthop Trauma Surg 126:49–52CrossRef Beaule′ PE, Antoniades J, Matta JM (2006) Trans-sacral fixation for failed posterior fixation of the pelvic ring. Arch Orthop Trauma Surg 126:49–52CrossRef
2.
Zurück zum Zitat Conflitti JM, Graves ML, Chip Routt ML (2010) Radiographic quantification and analysis of dysmorphic upper sacral osseous anatomy and associated iliosacral screw insertions. J Orthop Trauma 24:630–636PubMedCrossRef Conflitti JM, Graves ML, Chip Routt ML (2010) Radiographic quantification and analysis of dysmorphic upper sacral osseous anatomy and associated iliosacral screw insertions. J Orthop Trauma 24:630–636PubMedCrossRef
3.
Zurück zum Zitat Gardner MJ, Chip Routt ML (2011) Transiliac–transsacral screws for posterior pelvic stabilization. J Orthop Trauma 25:378–384PubMedCrossRef Gardner MJ, Chip Routt ML (2011) Transiliac–transsacral screws for posterior pelvic stabilization. J Orthop Trauma 25:378–384PubMedCrossRef
4.
Zurück zum Zitat Duwelius PJ, Van Allen M, Bray TJ et al (1992) Computed tomography-guided fixation of unstable posterior pelvic ring disruptions. J Orthop Trauma 6(4):420–426PubMedCrossRef Duwelius PJ, Van Allen M, Bray TJ et al (1992) Computed tomography-guided fixation of unstable posterior pelvic ring disruptions. J Orthop Trauma 6(4):420–426PubMedCrossRef
5.
Zurück zum Zitat Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop 242:83–97PubMed Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop 242:83–97PubMed
6.
Zurück zum Zitat Van Zwienen CM, Van den Bosch EW, Snijders CJ et al (2004) Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J Orthop Trauma 18(9):589–595PubMedCrossRef Van Zwienen CM, Van den Bosch EW, Snijders CJ et al (2004) Biomechanical comparison of sacroiliac screw techniques for unstable pelvic ring fractures. J Orthop Trauma 18(9):589–595PubMedCrossRef
Metadaten
Titel
Parameters of lengthened sacroiliac screw fixation: a radiological anatomy study
verfasst von
Yong Zhao
Jianmin Li
Dan Wang
Wei Lian
Publikationsdatum
01.09.2012
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 9/2012
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-012-2367-z

Weitere Artikel der Ausgabe 9/2012

European Spine Journal 9/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.