Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 3/2020

16.12.2019 | Original Paper

Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography

verfasst von: Alicia Gonzalez-Represas, Laurent Mourot

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 3/2020

Einloggen, um Zugang zu erhalten

Abstract

Given the increasing use of noninvasive techniques for the assessment of cardiac function in clinical practice, the aim of this study was to evaluate if stroke volume (SV) and cardiac output (CO) measurements obtained by PhysioFlow impedance cardiography or HDI CR-2000 pulse wave analysis (Pulse) are interchangeable with measurements obtained by echocardiography in patients with coronary artery disease (CAD) or heart failure (HF). The study involved 48 men with heart disease (CAD or HF). We compared SV and CO measurements with the three devices at rest, as well as relative changes in SV and CO derived from a rehabilitation program. SV and CO measurements were carried out first by echocardiography and immediately after using tonometry and impedancemetry techniques simultaneously. The Bland–Altman analysis showed a significant bias in the measurement of absolute SV and CO values with Pulse and PhysioFlow. Four quadrant plot and polar plot analysis of relative change SV between Pulse and echocardiography show a rate of concordance of 77% (95% CI 60–88%) and 79% (95% CI 63–89%) respectively. The polar plot analysis showed a mean polar angle of 34° ± 22°, and a 30° radial sector containing 52% of the data points. Both Pulse and PhysioFlow devices overestimate absolute SV and CO values compared to values recorded using echocardiography. Similarly, neither Pulse nor PhysioFlow reliably track SV or CO changes after a rehabilitation program compared with echocardiography.
Literatur
2.
Zurück zum Zitat Tan KH, Lai FO, Hwang NC (2006) Measurement of cardiac output using Physio Flow with different positions of electrode placement. Singap Med J 47:967–970 Tan KH, Lai FO, Hwang NC (2006) Measurement of cardiac output using Physio Flow with different positions of electrode placement. Singap Med J 47:967–970
4.
Zurück zum Zitat De Maria AN, Raisinghani A (2000) Comparative overview of cardiac output measurement methods: has impedance cardiography come of age? Congestive Heart Fail 6:60–73CrossRef De Maria AN, Raisinghani A (2000) Comparative overview of cardiac output measurement methods: has impedance cardiography come of age? Congestive Heart Fail 6:60–73CrossRef
5.
Zurück zum Zitat Min M, Annus P, Kõiv H, et al (2017) Bioimpedance sensing - a viable alternative for tonometry in non-invasive assessment of central aortic pressure. In: 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA). pp 373–378 Min M, Annus P, Kõiv H, et al (2017) Bioimpedance sensing - a viable alternative for tonometry in non-invasive assessment of central aortic pressure. In: 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA). pp 373–378
11.
Zurück zum Zitat Charloux A, Lonsdorfer-Wolf E, Richard R et al (2000) A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol 82:313–320CrossRefPubMed Charloux A, Lonsdorfer-Wolf E, Richard R et al (2000) A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol 82:313–320CrossRefPubMed
12.
Zurück zum Zitat Boussuges A (2006) Immersion in thermoneutral water: effects on arterial compliance. Aviat Space Environ Med 77:1183–1187PubMed Boussuges A (2006) Immersion in thermoneutral water: effects on arterial compliance. Aviat Space Environ Med 77:1183–1187PubMed
14.
Zurück zum Zitat McVeigh GE, Bratteli CW, Morgan DJ et al (1999) Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis aging and arterial compliance. Hypertension 33:1392–1398CrossRefPubMed McVeigh GE, Bratteli CW, Morgan DJ et al (1999) Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis aging and arterial compliance. Hypertension 33:1392–1398CrossRefPubMed
15.
Zurück zum Zitat Belardinelli R, Ciampani N, Costantini C et al (1996) Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy. Am J Cardiol 77:1293–1301CrossRefPubMed Belardinelli R, Ciampani N, Costantini C et al (1996) Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy. Am J Cardiol 77:1293–1301CrossRefPubMed
16.
Zurück zum Zitat Leslie SJ, McKee S, Newby DE et al (2004) Non-invasive measurement of cardiac output in patients with chronic heart failure. Blood Press Monit 9:277–280CrossRefPubMed Leslie SJ, McKee S, Newby DE et al (2004) Non-invasive measurement of cardiac output in patients with chronic heart failure. Blood Press Monit 9:277–280CrossRefPubMed
20.
Zurück zum Zitat Rietzschel ER, Boeykens E, De Buyzere ML et al (2001) A comparison between systolic and diastolic pulse contour analysis in the evaluation of arterial stiffness. Hypertens Dallas Tex 1979 37:E15–E22 Rietzschel ER, Boeykens E, De Buyzere ML et al (2001) A comparison between systolic and diastolic pulse contour analysis in the evaluation of arterial stiffness. Hypertens Dallas Tex 1979 37:E15–E22
22.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet Lond Engl 1:307–310CrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet Lond Engl 1:307–310CrossRef
23.
Zurück zum Zitat Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85–91CrossRefPubMed Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85–91CrossRefPubMed
27.
Zurück zum Zitat Yajima T, Nitta M, Nakamura S et al (1992) Reliability of Doppler echocardiographic stroke volume measurement. Bull Tokyo Med Dent Univ 39:55–62PubMed Yajima T, Nitta M, Nakamura S et al (1992) Reliability of Doppler echocardiographic stroke volume measurement. Bull Tokyo Med Dent Univ 39:55–62PubMed
29.
Zurück zum Zitat Cybulski G, Strasz A, Niewiadomski W, Gąsiorowska A (2012) Impedance cardiography: recent advancements. Cardiol J 19:550–556CrossRefPubMed Cybulski G, Strasz A, Niewiadomski W, Gąsiorowska A (2012) Impedance cardiography: recent advancements. Cardiol J 19:550–556CrossRefPubMed
38.
Zurück zum Zitat Kouchoukos NT, Sheppard LC, McDonald DA (1970) Estimation of stroke volume in the dog by a pulse contour method. Circ Res 26:611–623CrossRefPubMed Kouchoukos NT, Sheppard LC, McDonald DA (1970) Estimation of stroke volume in the dog by a pulse contour method. Circ Res 26:611–623CrossRefPubMed
40.
Zurück zum Zitat Romagnoli S, Bevilacqua S, Lazzeri C et al (2009) Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM). HSR Proc Intensive Care Cardiovasc Anesth 1:20–27PubMedPubMedCentral Romagnoli S, Bevilacqua S, Lazzeri C et al (2009) Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM). HSR Proc Intensive Care Cardiovasc Anesth 1:20–27PubMedPubMedCentral
41.
Zurück zum Zitat Cecconi M, Rhodes A, Poloniecki J et al (2009) Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies–with specific reference to the measurement of cardiac output. Crit Care Lond Engl 13:201. https://doi.org/10.1186/cc7129 CrossRef Cecconi M, Rhodes A, Poloniecki J et al (2009) Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies–with specific reference to the measurement of cardiac output. Crit Care Lond Engl 13:201. https://​doi.​org/​10.​1186/​cc7129 CrossRef
Metadaten
Titel
Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography
verfasst von
Alicia Gonzalez-Represas
Laurent Mourot
Publikationsdatum
16.12.2019
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 3/2020
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-019-01738-y

Weitere Artikel der Ausgabe 3/2020

The International Journal of Cardiovascular Imaging 3/2020 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.