Skip to main content
Erschienen in: Journal of Nuclear Cardiology 6/2016

01.12.2016 | Original Article

Comparative accuracy of supine-only and combined supine-prone myocardial perfusion imaging in men

verfasst von: Vicente Taasan, MD, Anita Wokhlu, MD, Michael V. Taasan, MPH, Raman S. Dusaj, MD, Ajay Mehta, MD, Steven Kraft, MD, David Winchester, MD, David Wymer, MD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

Combined supine-prone myocardial perfusion imaging (CSP MPI) has been shown to reduce attenuation artifact in comparison to supine-only (SU) MPI in mixed-gender populations with varying risk for coronary artery disease (CAD), often where patients served as their own controls. However, there is limited direct comparison of these imaging strategies in men.

Methods

934 male patients underwent CSP or SU MPI. Diagnostic certainty of interpretation was compared. Within the cohort, 116 were referred for left heart catheterization (LHC) to assess for CAD. Sensitivity, specificity, and area under the curve (AUC) were compared with additional analysis based on body mass index (BMI).

Results

597 patients completed the SU protocol and 337 patients completed the CSP protocol. Equivocal studies were seen more frequently in the SU group (13%) than in the CSP group (4%, P < .001). At catheterization, the specificity for CSP MPI of 70% was higher than 40% for SU MPI (P = .032). The CSP AUC (0.80 ± 0.06) was significantly larger than SU AUC (0.57 ± 0.05, P = .004). CSP specificity was significantly higher in obese patients.

Conclusions

CSP MPI increases diagnostic certainty and improves test accuracy for CAD detection in men with CAD risk factors, especially obese patients, compared to SU MPI.
Literatur
1.
Zurück zum Zitat Hendel RC. Attenuation correction: Eternal dilemma or real improvement? J Nucl Med Mol Imaging 2005;49:30-42. Hendel RC. Attenuation correction: Eternal dilemma or real improvement? J Nucl Med Mol Imaging 2005;49:30-42.
2.
Zurück zum Zitat Esquerre J-P, Coca FJ, Martinez SJ, Guiraud RF. Prone decubitus: A solution to inferior wall attenuation in thallium-201 myocardial tomography. J Nucl Med 1989;30:398-401.PubMed Esquerre J-P, Coca FJ, Martinez SJ, Guiraud RF. Prone decubitus: A solution to inferior wall attenuation in thallium-201 myocardial tomography. J Nucl Med 1989;30:398-401.PubMed
3.
Zurück zum Zitat Segall GM, Davis M. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior defects. J Nucl Med 1989;30:548-55.PubMed Segall GM, Davis M. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior defects. J Nucl Med 1989;30:548-55.PubMed
4.
Zurück zum Zitat Kiat H, Van Train KF, Friedman JD, Germano G, Silagan G, Wang FP, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: Methodologic development and validation. J Nucl Med 1992;33:1509-15.PubMed Kiat H, Van Train KF, Friedman JD, Germano G, Silagan G, Wang FP, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: Methodologic development and validation. J Nucl Med 1992;33:1509-15.PubMed
5.
Zurück zum Zitat Slomka PJ, Nishina H, Abidov A, Hayes SW, Friedman JD, Berman DS, et al. Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women. J Nucl Cardiol 2007;14:44-52.CrossRefPubMed Slomka PJ, Nishina H, Abidov A, Hayes SW, Friedman JD, Berman DS, et al. Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women. J Nucl Cardiol 2007;14:44-52.CrossRefPubMed
6.
Zurück zum Zitat Berman DS, Kang XP, Nishina H, Slomka PJ, Shaw LJ, Hayes SW, et al. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and non-obese patients. J Nucl Cardiol 2006;13:191-201.CrossRefPubMed Berman DS, Kang XP, Nishina H, Slomka PJ, Shaw LJ, Hayes SW, et al. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and non-obese patients. J Nucl Cardiol 2006;13:191-201.CrossRefPubMed
7.
Zurück zum Zitat Hayes SW, DeLorenzo A, Hachamovich R, Dhar SC, Hsu P, Cohen I, et al. Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed Hayes SW, DeLorenzo A, Hachamovich R, Dhar SC, Hsu P, Cohen I, et al. Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed
8.
Zurück zum Zitat Malkemeker D, Brenner R, Martin WH, Sampson UK, Feurer ID, Kronenberg MW, et al. CT-based attenuation correction versus prone imaging to decrease equivocal interpretation of rest/stress TC-99m tetrofosmin SPECT MPI. J Nucl Cardiol 2007;14:314-23.CrossRef Malkemeker D, Brenner R, Martin WH, Sampson UK, Feurer ID, Kronenberg MW, et al. CT-based attenuation correction versus prone imaging to decrease equivocal interpretation of rest/stress TC-99m tetrofosmin SPECT MPI. J Nucl Cardiol 2007;14:314-23.CrossRef
9.
Zurück zum Zitat Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. CCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. Circulation 2009;119:e561-87.CrossRefPubMed Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. CCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. Circulation 2009;119:e561-87.CrossRefPubMed
10.
Zurück zum Zitat Winchester DE, Kitchen A, Brandt JC, Dusaj RS, Virani SS, Bradley SM, et al. Metrics of quality care in veterans: Correlation between primary-care performance measures and inappropriate myocardial perfusion imaging. Clin Cardiol 2015;38:195-9.CrossRefPubMedPubMedCentral Winchester DE, Kitchen A, Brandt JC, Dusaj RS, Virani SS, Bradley SM, et al. Metrics of quality care in veterans: Correlation between primary-care performance measures and inappropriate myocardial perfusion imaging. Clin Cardiol 2015;38:195-9.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Tilkemeier PL, Cooke CD, Grossman GB, Mcallister BD, Ward BD, Clinical Guidelines and Quality Standards, American Society of Nuclear Cardiology. ASNC Imaging Guidelines for Nuclear Cardiology Procedures: Standardized reporting of radionuclide myocardial perfusion and function. Am Soc Nucl Cardiol 2009. doi:10.1007/s12350-009-9095-8.11. Tilkemeier PL, Cooke CD, Grossman GB, Mcallister BD, Ward BD, Clinical Guidelines and Quality Standards, American Society of Nuclear Cardiology. ASNC Imaging Guidelines for Nuclear Cardiology Procedures: Standardized reporting of radionuclide myocardial perfusion and function. Am Soc Nucl Cardiol 2009. doi:10.​1007/​s12350-009-9095-8.​11.
12.
Zurück zum Zitat Hendel RC, Wackers FJ, Berman D, Ficaro E, DePuey E, Klein EG, et al. American Society of Nuclear Cardiology Consensus Statement: Reporting of radionuclide myocardial perfusion imaging studies. J Nucl Cardiol 2003;10:705-8.CrossRefPubMed Hendel RC, Wackers FJ, Berman D, Ficaro E, DePuey E, Klein EG, et al. American Society of Nuclear Cardiology Consensus Statement: Reporting of radionuclide myocardial perfusion imaging studies. J Nucl Cardiol 2003;10:705-8.CrossRefPubMed
13.
Zurück zum Zitat DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: A non-parametric approach. Biometrics 1998;44:837-45.CrossRef DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: A non-parametric approach. Biometrics 1998;44:837-45.CrossRef
14.
Zurück zum Zitat Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed
15.
Zurück zum Zitat Arsanjani R, Hayes SW, Fish M, Shalev A, Nakanishi R, Thomson L, et al. Two-position supine/prone myocardial perfusion SPECT(MPS) imaging improves visual inter-observer correlation and agreement. J Nucl Cardiol 2014;21:703-11.CrossRefPubMedPubMedCentral Arsanjani R, Hayes SW, Fish M, Shalev A, Nakanishi R, Thomson L, et al. Two-position supine/prone myocardial perfusion SPECT(MPS) imaging improves visual inter-observer correlation and agreement. J Nucl Cardiol 2014;21:703-11.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Perault C, Loboguerro A, Lien J-C, Wampach H, Gibold C, Ouzan J, et al. Quantitative comparison of prone and supine myocardial SPECT images. Clin Nucl Med 1994;20:678-84.CrossRef Perault C, Loboguerro A, Lien J-C, Wampach H, Gibold C, Ouzan J, et al. Quantitative comparison of prone and supine myocardial SPECT images. Clin Nucl Med 1994;20:678-84.CrossRef
17.
Zurück zum Zitat Katayama T, Ogata N, Tsuruya Y. Diagnostic accuracy of supine and prone thallium-201 stress myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in inferior wall of the left ventricle. Ann Nucl Med 2008;24:317-21.CrossRef Katayama T, Ogata N, Tsuruya Y. Diagnostic accuracy of supine and prone thallium-201 stress myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in inferior wall of the left ventricle. Ann Nucl Med 2008;24:317-21.CrossRef
18.
Zurück zum Zitat Rozanski A, Diamond GA, Berman D, Forrester JS, Morris D, Swan HJC. The declining specificity of exercise radionuclide ventriculography. N Engl J Med 1983;309:518-22.CrossRefPubMed Rozanski A, Diamond GA, Berman D, Forrester JS, Morris D, Swan HJC. The declining specificity of exercise radionuclide ventriculography. N Engl J Med 1983;309:518-22.CrossRefPubMed
19.
Zurück zum Zitat Rozanski A, Berman D. The efficacy of cardiovascular nuclear medicine studies. Semin Nucl Med 1987;2:104-20.CrossRef Rozanski A, Berman D. The efficacy of cardiovascular nuclear medicine studies. Semin Nucl Med 1987;2:104-20.CrossRef
20.
Zurück zum Zitat Li J, Elrashidi MY, Flammer AJ, Lennon RJ, Bell MR, Holmes D, et al. Long-term outcomes of fractional flow reserve-guided vs. angiography-guided percutaneous coronary intervention in contemporary practice. Eur Heart J 2013;34:1375-83.CrossRefPubMedPubMedCentral Li J, Elrashidi MY, Flammer AJ, Lennon RJ, Bell MR, Holmes D, et al. Long-term outcomes of fractional flow reserve-guided vs. angiography-guided percutaneous coronary intervention in contemporary practice. Eur Heart J 2013;34:1375-83.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Takamura T, Horiguchi Y, Kanna M, Matsushita H, Sudo Y, Kikuchi S, et al. Validation of prone myocardial perfusion SEPCT with a variable focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction. Ann Nucl Med 2015. doi:10.1007/s12149-015-1019-x.PubMed Takamura T, Horiguchi Y, Kanna M, Matsushita H, Sudo Y, Kikuchi S, et al. Validation of prone myocardial perfusion SEPCT with a variable focus collimator versus supine myocardial perfusion SPECT with or without computed tomography-derived attenuation correction. Ann Nucl Med 2015. doi:10.​1007/​s12149-015-1019-x.PubMed
22.
Zurück zum Zitat Malkerneker D, Brenner R, Martin WH, Sampson UK, Feurer ID, Kronenberg MW, et al. CT-based attenuation correction versus prone imaging to decrease equivocal interpretations of rest/stress Tc-99m tetrofosmin SPECT MPI. J Nucl Cardiol 2007;14:314-23.CrossRefPubMed Malkerneker D, Brenner R, Martin WH, Sampson UK, Feurer ID, Kronenberg MW, et al. CT-based attenuation correction versus prone imaging to decrease equivocal interpretations of rest/stress Tc-99m tetrofosmin SPECT MPI. J Nucl Cardiol 2007;14:314-23.CrossRefPubMed
23.
Zurück zum Zitat Reyes E, Wiener S, Underwood SR, European Council of Nuclear Cardiology. Myocardial perfusion scintigraphy in Europe 2007: A survey of the European Council of Nuclear. Cardiology 2012;39:160-4. Reyes E, Wiener S, Underwood SR, European Council of Nuclear Cardiology. Myocardial perfusion scintigraphy in Europe 2007: A survey of the European Council of Nuclear. Cardiology 2012;39:160-4.
24.
Zurück zum Zitat Shin J, Pokhara H, Williams K, Mehta R, Ward RP. SPECT myocardial perfusion imaging with prone only acquisitions: Correlation with coronary angiography. J Nucl Cardiol 2009;16:590-6.CrossRefPubMed Shin J, Pokhara H, Williams K, Mehta R, Ward RP. SPECT myocardial perfusion imaging with prone only acquisitions: Correlation with coronary angiography. J Nucl Cardiol 2009;16:590-6.CrossRefPubMed
Metadaten
Titel
Comparative accuracy of supine-only and combined supine-prone myocardial perfusion imaging in men
verfasst von
Vicente Taasan, MD
Anita Wokhlu, MD
Michael V. Taasan, MPH
Raman S. Dusaj, MD
Ajay Mehta, MD
Steven Kraft, MD
David Winchester, MD
David Wymer, MD
Publikationsdatum
01.12.2016
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 6/2016
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-015-0358-2

Weitere Artikel der Ausgabe 6/2016

Journal of Nuclear Cardiology 6/2016 Zur Ausgabe

Ist Fasten vor Koronarinterventionen wirklich nötig?

Wenn Eingriffe wie eine Koronarangiografie oder eine Koronarangioplastie anstehen, wird häufig empfohlen, in den Stunden zuvor nüchtern zu bleiben. Ein französisches Forscherteam hat diese Maßnahme hinterfragt.

PET kann infarktgefährdete Koronararterien entdecken

04.06.2024 Koronare Herzerkrankung Nachrichten

Der Nachweis aktiver Plaques mittels 18F-Natriumfluorid-PET hilft nicht nur, infarktgefährdete Patienten, sondern auch infarktgefährdete Koronararterien zu erkennen. Von einer gezielten Behandlung vulnerabler Plaques ist man trotzdem weit entfernt.

GLP-1-Agonist Semaglutid wirkt kardio- und nephroprotektiv

03.06.2024 Semaglutid Nachrichten

Der GLP-1-Agonist Semaglutid hat in der FLOW-Studie bewiesen, dass sich damit die Progression chronischer Nierenerkrankungen bei Patienten mit Typ-2-Diabetes bremsen lässt. Auch in kardiovaskulärer Hinsicht war die Therapie erfolgreich.

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.