verfasst von: Adrián Jerónimo, MD, Carmen Olmos, MD, PhD, Isidre Vilacosta, MD, PhD, Aida Ortega-Candil, MD, PhD, Cristina Rodríguez-Rey, MD, PhD, María Jesús Pérez-Castejón, MD, PhD, Cristina Fernández-Pérez, MD, PhD, Carlos Nicolás Pérez-García, MD, Daniel García-Arribas, MD, Carlos Ferrera, MD, PhD, José Luis Carreras, MD, PhD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 2/2022

Einloggen, um Zugang zu erhalten

Abstract

Background

Utility of 18F-FDG PET/CT in diagnosing infective endocarditis (IE) associated with cardiac implantable electronic devices (CIEDs) is not well established. Current ESC guidelines recommend the use of FDG-PET imaging in patients with CIEDs and positive blood cultures, but the number of studies evaluating the diagnostic performance of FDG-PET imaging in these patients remain limited. Our objective was to assess the diagnostic yield of 18F-FDG PET/CT in patients with suspected CIED infections, differentiating between pocket infection (PI) and lead infection (CIED-IE).

Methods and Results

From 2013 to 2018, all patients (n = 63) admitted to a hospital with suspected CIED infection were prospectively recruited, undergoing a diagnostic work-up including a PET/CT. Explanted devices and material from the pocket were cultured. 14 cases corresponded to isolated PI and 13 were categorized as CIED-IE. Considering radionuclide uptake in the intracardiac portion of the lead, sensitivity and specificity of PET/CT for CIED-IE were 38.5% and 98.0%, respectively. Positive (19.2) and negative (0.6) likelihood ratio values, suggest that a positive PET/CT is much more probable to correspond to a patient with CIED-IE, whereas it is not possible to exclude this diagnosis when negative. For PI, sensitivity and specificity were 72.2% and 95.6%, respectively.

Conclusions

The yield of 18F-FDG PET/CT for suspected CIED infections differs depending on the site of infection. Due to very high specificity but poor sensitivity, negative studies must be interpreted with caution if the suspicion of CIED-IE is high.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Saby L, Laas O, Habib G, Cammilleri S, Mancini J, Tessonnier L, et al. Positron emission tomography/computed tomography for diagnosis of prosthetic valve endocarditis: Increased valvular 18F-fluorodeoxyglucose uptake as a novel major criterion. J Am Coll Cardiol 2013;61:2374-84.CrossRef Saby L, Laas O, Habib G, Cammilleri S, Mancini J, Tessonnier L, et al. Positron emission tomography/computed tomography for diagnosis of prosthetic valve endocarditis: Increased valvular 18F-fluorodeoxyglucose uptake as a novel major criterion. J Am Coll Cardiol 2013;61:2374-84.CrossRef
2.
Zurück zum Zitat Pizzi MN, Roque A, Fernández-Hidalgo N, Cuéllar-Calabria H, Ferreira-González I, Gonzàlez-Alujas MT, et al. Improving the diagnosis of infective endocarditis in prosthetic valves and intracardiac devices with 18F-fluordeoxyglucose positron emission tomography/computed tomography angiography. Initial results at an infective endocarditis referral center. Circulation 2015;132:1113-26.CrossRef Pizzi MN, Roque A, Fernández-Hidalgo N, Cuéllar-Calabria H, Ferreira-González I, Gonzàlez-Alujas MT, et al. Improving the diagnosis of infective endocarditis in prosthetic valves and intracardiac devices with 18F-fluordeoxyglucose positron emission tomography/computed tomography angiography. Initial results at an infective endocarditis referral center. Circulation 2015;132:1113-26.CrossRef
3.
Zurück zum Zitat Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, et al. 2015 ESC Guidelines for the management of infective endocarditis: The Task Force for the Management of Infective Endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J 2015;36:3075-128.CrossRef Habib G, Lancellotti P, Antunes MJ, Bongiorni MG, Casalta JP, Del Zotti F, et al. 2015 ESC Guidelines for the management of infective endocarditis: The Task Force for the Management of Infective Endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM). Eur Heart J 2015;36:3075-128.CrossRef
4.
Zurück zum Zitat Tlili G, Amraoui S, Mesguich C, Rivière A, Bordachar P, Hindié E, et al. High performances of (18)F-fluorodeoxyglucose PET–CT in cardiac implantable device infections: A study of 40 patients. J Nucl Cardiol 2015;22:787-98.CrossRef Tlili G, Amraoui S, Mesguich C, Rivière A, Bordachar P, Hindié E, et al. High performances of (18)F-fluorodeoxyglucose PET–CT in cardiac implantable device infections: A study of 40 patients. J Nucl Cardiol 2015;22:787-98.CrossRef
5.
Zurück zum Zitat Sarrazin JF, Philippon F, Tessier M, Guimond J, Molin F, Champagne J, et al. Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections. J Am Coll Cardiol 2012;59:1616-25.CrossRef Sarrazin JF, Philippon F, Tessier M, Guimond J, Molin F, Champagne J, et al. Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections. J Am Coll Cardiol 2012;59:1616-25.CrossRef
6.
Zurück zum Zitat Cautela J, Alessandrini S, Cammilleri S, Giorgi R, Richet H, Casalta JP, et al. Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: A pilot study. Europace 2013;15:252-7.CrossRef Cautela J, Alessandrini S, Cammilleri S, Giorgi R, Richet H, Casalta JP, et al. Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: A pilot study. Europace 2013;15:252-7.CrossRef
7.
Zurück zum Zitat Graziosi M, Nanni C, Lorenzini M, Diemberger I, Bonfiglioli R, Pasguale F, et al. Role of 18F-FDG PET/CT in the diagnosis of infective endocarditis in patients with an implanted cardiac device: A prospective study. Eur J Nucl Med Mol Imaging 2014;41:1617-23.CrossRef Graziosi M, Nanni C, Lorenzini M, Diemberger I, Bonfiglioli R, Pasguale F, et al. Role of 18F-FDG PET/CT in the diagnosis of infective endocarditis in patients with an implanted cardiac device: A prospective study. Eur J Nucl Med Mol Imaging 2014;41:1617-23.CrossRef
8.
Zurück zum Zitat Jamar F, Buscombe J, Chiti A, Christian PE, Delbeke D, Donohoe KJ, et al. EANM/SNMMI guideline for 18F-FDG use in inflammation and infection. J Nucl Med 2013;54:647-58.CrossRef Jamar F, Buscombe J, Chiti A, Christian PE, Delbeke D, Donohoe KJ, et al. EANM/SNMMI guideline for 18F-FDG use in inflammation and infection. J Nucl Med 2013;54:647-58.CrossRef
9.
Zurück zum Zitat Jiménez-Ballvé A, Pérez-Castejón MJ, Delgado-Bolton RC, Delgado-Bolton RC, Sánchez-Enrique C, Vilacosta I, et al. Assessment of the diagnostic accuracy of (18)F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: Comparison of different interpretation criteria. Eur J Nucl Med Mol Imaging 2016;43:2401-12.CrossRef Jiménez-Ballvé A, Pérez-Castejón MJ, Delgado-Bolton RC, Delgado-Bolton RC, Sánchez-Enrique C, Vilacosta I, et al. Assessment of the diagnostic accuracy of (18)F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: Comparison of different interpretation criteria. Eur J Nucl Med Mol Imaging 2016;43:2401-12.CrossRef
10.
Zurück zum Zitat Erba PA, Lancellotti P, Vilacosta I, Gaemperli O, Rouzet F, Hacker M, et al. Recommendations on nuclear and multimodality imaging in IE and CIED infections. Eur J Nucl Med Mol Imaging 2018;45:1795-815.CrossRef Erba PA, Lancellotti P, Vilacosta I, Gaemperli O, Rouzet F, Hacker M, et al. Recommendations on nuclear and multimodality imaging in IE and CIED infections. Eur J Nucl Med Mol Imaging 2018;45:1795-815.CrossRef
11.
Zurück zum Zitat Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, et al. Infective endocarditis complicating permanent pacemaker and implantable cardioverter-defibrillator infection. Mayo Clin Proc 2008;83:46-53.CrossRef Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, et al. Infective endocarditis complicating permanent pacemaker and implantable cardioverter-defibrillator infection. Mayo Clin Proc 2008;83:46-53.CrossRef
12.
Zurück zum Zitat Uslan DZ, Sohail MR, St Sauver JL, Friedman PA, Hayes DL, Stoner SM, et al. Permanent pacemaker and implantable cardioverter defibrillator infection. Arch Intern Med 2007;167:669-75.CrossRef Uslan DZ, Sohail MR, St Sauver JL, Friedman PA, Hayes DL, Stoner SM, et al. Permanent pacemaker and implantable cardioverter defibrillator infection. Arch Intern Med 2007;167:669-75.CrossRef
13.
Zurück zum Zitat Downey BC, Juselius WE, Pandian NG, Estes NA 3rd, Link MS. Incidence and significance of pacemaker and implantable cardioverter-defibrillator lead masses discovered during transesophageal echocardiography. Pacing Clin Electrophysiol 2011;34:679-83.CrossRef Downey BC, Juselius WE, Pandian NG, Estes NA 3rd, Link MS. Incidence and significance of pacemaker and implantable cardioverter-defibrillator lead masses discovered during transesophageal echocardiography. Pacing Clin Electrophysiol 2011;34:679-83.CrossRef
14.
Zurück zum Zitat Ploux S, Riviere A, Amraoui S, Whinnett Z, Barandon L, Lafitte S, et al. Positron emission tomography in patients with suspected pacing system infections may play a critical role in difficult cases. Heart Rhythm 2011;8:1478-81.CrossRef Ploux S, Riviere A, Amraoui S, Whinnett Z, Barandon L, Lafitte S, et al. Positron emission tomography in patients with suspected pacing system infections may play a critical role in difficult cases. Heart Rhythm 2011;8:1478-81.CrossRef
15.
Zurück zum Zitat Bensimhon L, Lavergne T, Hugonnet F, Mainardi JL, Latremouille C, Maunoury C, et al. Whole body [(18) F]fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection: A preliminary prospective study. Clin Microbiol Infect 2011;17:836-44.CrossRef Bensimhon L, Lavergne T, Hugonnet F, Mainardi JL, Latremouille C, Maunoury C, et al. Whole body [(18) F]fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection: A preliminary prospective study. Clin Microbiol Infect 2011;17:836-44.CrossRef
16.
Zurück zum Zitat Leccisotti L, Perna F, Lago M, Leo M, Sterfanelli A, Calcagni ML, et al. Cardiovascular implantable electronic device infection: Delayed vs standard FDG PET–CT imaging. J Nucl Cardiol 2014;21:622-32.CrossRef Leccisotti L, Perna F, Lago M, Leo M, Sterfanelli A, Calcagni ML, et al. Cardiovascular implantable electronic device infection: Delayed vs standard FDG PET–CT imaging. J Nucl Cardiol 2014;21:622-32.CrossRef
17.
Zurück zum Zitat Granados U, Fuster D, Pericas JM, Llopis JL, Ninot S, Quintana E, et al. Diagnostic accuracy of 18F-FDG PET/CT in infective endocarditis and implantable cardiac electronic device infection: A cross-sectional study. J Nucl Med 2016;57:1726-32.CrossRef Granados U, Fuster D, Pericas JM, Llopis JL, Ninot S, Quintana E, et al. Diagnostic accuracy of 18F-FDG PET/CT in infective endocarditis and implantable cardiac electronic device infection: A cross-sectional study. J Nucl Med 2016;57:1726-32.CrossRef
18.
Zurück zum Zitat Blomström-Lundqvist C, Traykov V, Erba PA, Burri H, Nielsen JC, Bongiorni MG, et al. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections—Endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID), and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Europace 2020;22:515-49.CrossRef Blomström-Lundqvist C, Traykov V, Erba PA, Burri H, Nielsen JC, Bongiorni MG, et al. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections—Endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID), and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Europace 2020;22:515-49.CrossRef
19.
Zurück zum Zitat Sandoe JA, Barlow G, Chambers JB, Gammage M, Guleri A, Howard P, et al. Guidelines for the diagnosis, prevention and management of implantable cardiac electronic devices infection. Report of a Joint Working Party Project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE). J Antimicrob Chemother 2015;70:325-59.CrossRef Sandoe JA, Barlow G, Chambers JB, Gammage M, Guleri A, Howard P, et al. Guidelines for the diagnosis, prevention and management of implantable cardiac electronic devices infection. Report of a Joint Working Party Project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE). J Antimicrob Chemother 2015;70:325-59.CrossRef
20.
Zurück zum Zitat Habib G, Erba PA, Iung B, Donal E, Cosyns B, Laroche C, et al. Clinical presentation, aetiology and outcome of infective endocarditis. Results of the ESC-EORP EURO-ENDO (European Infective Endocarditis) Registry: A prospective cohort study. Eur Heart J 2019;40:3222-32.CrossRef Habib G, Erba PA, Iung B, Donal E, Cosyns B, Laroche C, et al. Clinical presentation, aetiology and outcome of infective endocarditis. Results of the ESC-EORP EURO-ENDO (European Infective Endocarditis) Registry: A prospective cohort study. Eur Heart J 2019;40:3222-32.CrossRef
21.
Zurück zum Zitat Juneau D, Golfam M, Hazra S, Zuckier LS, Garas S, Redpath C, et al. Positron emission tomography and single-photon emission computed tomography imaging in the diagnosis of cardiac implantable electronic device infection: A systematic review and meta-analysis. Circ Cardiovasc Imaging 2017;10:1-11.CrossRef Juneau D, Golfam M, Hazra S, Zuckier LS, Garas S, Redpath C, et al. Positron emission tomography and single-photon emission computed tomography imaging in the diagnosis of cardiac implantable electronic device infection: A systematic review and meta-analysis. Circ Cardiovasc Imaging 2017;10:1-11.CrossRef
22.
Zurück zum Zitat Diemberger I, Bonfiglioli R, Martignani C, Graziosi M, Biffi M, Lorenzett S, et al. Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: A prospective single center study. Eur J Nucl Med Mol Imaging 2019;46:194-205.CrossRef Diemberger I, Bonfiglioli R, Martignani C, Graziosi M, Biffi M, Lorenzett S, et al. Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: A prospective single center study. Eur J Nucl Med Mol Imaging 2019;46:194-205.CrossRef
23.
Zurück zum Zitat Swart LE, Gomes A, Scholtens AM, Sinha B, Tanis W, Lam MGEH, et al. Improving the diagnostic performance of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography in prosthetic heart valve endocarditis. Circulation 2018;138:1412-27.CrossRef Swart LE, Gomes A, Scholtens AM, Sinha B, Tanis W, Lam MGEH, et al. Improving the diagnostic performance of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography in prosthetic heart valve endocarditis. Circulation 2018;138:1412-27.CrossRef
25.
Zurück zum Zitat Calais J, Touati A, Grall N, Laouénan C, Benali K, Mahida B, et al. Diagnostic impact of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and white blood cell SPECT/computed tomography in patients with suspected cardiac implantable electronic device chronic infection. Circ Cardiovasc Imaging. 2019;12:e007188.CrossRef Calais J, Touati A, Grall N, Laouénan C, Benali K, Mahida B, et al. Diagnostic impact of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and white blood cell SPECT/computed tomography in patients with suspected cardiac implantable electronic device chronic infection. Circ Cardiovasc Imaging. 2019;12:e007188.CrossRef
Metadaten
Titel
Accuracy of 18F-FDG PET/CT in patients with the suspicion of cardiac implantable electronic device infections
verfasst von
Adrián Jerónimo, MD
Carmen Olmos, MD, PhD
Isidre Vilacosta, MD, PhD
Aida Ortega-Candil, MD, PhD
Cristina Rodríguez-Rey, MD, PhD
María Jesús Pérez-Castejón, MD, PhD
Cristina Fernández-Pérez, MD, PhD
Carlos Nicolás Pérez-García, MD
Daniel García-Arribas, MD
Carlos Ferrera, MD, PhD
José Luis Carreras, MD, PhD
Publikationsdatum
03.08.2020
Verlag
Springer International Publishing
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 2/2022
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-020-02285-z

Weitere Artikel der Ausgabe 2/2022

Journal of Nuclear Cardiology 2/2022 Zur Ausgabe

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.