01.03.2016 | Systematic Review

Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness

verfasst von: T. G. Eskesen, M. Wetterslev, A. Perner

Erschienen in: Intensive Care Medicine | Ausgabe 3/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Central venous pressure (CVP) has been shown to have poor predictive value for fluid responsiveness in critically ill patients. We aimed to re-evaluate this in a larger sample subgrouped by baseline CVP values.

Methods

In April 2015, we systematically searched and included all clinical studies evaluating the value of CVP in predicting fluid responsiveness. We contacted investigators for patient data sets. We subgrouped data as lower (<8 mmHg), intermediate (8–12 mmHg) and higher (>12 mmHg) baseline CVP.

Results

We included 51 studies; in the majority, mean/median CVP values were in the intermediate range (8–12 mmHg) in both fluid responders and non-responders. In an analysis of patient data sets (n = 1148) from 22 studies, the area under the receiver operating curve was above 0.50 in the <8 mmHg CVP group [0.57 (95 % CI 0.52–0.62)] in contrast to the 8–12 mmHg and >12 mmHg CVP groups in which the lower 95 % CI crossed 0.50. We identified some positive and negative predictive value for fluid responsiveness for specific low and high values of CVP, respectively, but none of the predictive values were above 66 % for any CVPs from 0 to 20 mmHg. There were less data on higher CVPs, in particular >15 mmHg, making the estimates on predictive values less precise for higher CVP.

Conclusions

Most studies evaluating fluid responsiveness reported mean/median CVP values in the intermediate range of 8–12 mmHg both in responders and non-responders. In a re-analysis of 1148 patient data sets, specific lower and higher CVP values had some positive and negative predictive value for fluid responsiveness, respectively, but predictive values were low for all specific CVP values assessed.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
2.
Zurück zum Zitat Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A (2009) Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 37:2642–2647CrossRefPubMed
3.
Zurück zum Zitat Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA (2011) Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 39:259–265CrossRefPubMed Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA (2011) Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med 39:259–265CrossRefPubMed
4.
Zurück zum Zitat Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant JY, De Backer D (2015) Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med 41:1529–1537CrossRefPubMedPubMedCentral Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant JY, De Backer D (2015) Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med 41:1529–1537CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Sondergaard S, Parkin G, Aneman A (2015) Central venous pressure: we need to bring clinical use into physiological context. Acta Anaesthesiol Scand 59:552–560CrossRefPubMed Sondergaard S, Parkin G, Aneman A (2015) Central venous pressure: we need to bring clinical use into physiological context. Acta Anaesthesiol Scand 59:552–560CrossRefPubMed
6.
Zurück zum Zitat Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, Sevransky JE, Sprung CL, Douglas IS, Jaeschke R, Osborn TM, Nunnally ME, Townsend SR, Reinhart K, Kleinpell RM, Angus DC, Deutschman CS, Machado FR, Rubenfeld GD, Webb S, Beale RJ, Vincent JL, Moreno R (2013) Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med 39:165–228CrossRefPubMed Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, Sevransky JE, Sprung CL, Douglas IS, Jaeschke R, Osborn TM, Nunnally ME, Townsend SR, Reinhart K, Kleinpell RM, Angus DC, Deutschman CS, Machado FR, Rubenfeld GD, Webb S, Beale RJ, Vincent JL, Moreno R (2013) Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med 39:165–228CrossRefPubMed
7.
Zurück zum Zitat Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134:172–178CrossRefPubMed Marik PE, Baram M, Vahid B (2008) Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 134:172–178CrossRefPubMed
8.
Zurück zum Zitat Marik PE, Cavallazzi R (2013) Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med 41:1774–1781CrossRefPubMed Marik PE, Cavallazzi R (2013) Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med 41:1774–1781CrossRefPubMed
9.
Zurück zum Zitat Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, Jaeschke R, Mebazaa A, Pinsky MR, Teboul JL, Vincent JL, Rhodes A (2014) Consensus on circulatory shock and hemodynamic monitoring. Task Force of the European Society of Intensive Care Medicine. Intensive Care Med 40:1795–1815CrossRefPubMedPubMedCentral Cecconi M, De Backer D, Antonelli M, Beale R, Bakker J, Hofer C, Jaeschke R, Mebazaa A, Pinsky MR, Teboul JL, Vincent JL, Rhodes A (2014) Consensus on circulatory shock and hemodynamic monitoring. Task Force of the European Society of Intensive Care Medicine. Intensive Care Med 40:1795–1815CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M (2001) Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345:1368–1377CrossRef Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M (2001) Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345:1368–1377CrossRef
11.
Zurück zum Zitat Wetterslev M, Haase N, Johansen RR, Perner A (2013) Predicting fluid responsiveness with transthoracic echocardiography is not yet evidence based. Acta Anaesthesiol Scand 57:692–697CrossRefPubMed Wetterslev M, Haase N, Johansen RR, Perner A (2013) Predicting fluid responsiveness with transthoracic echocardiography is not yet evidence based. Acta Anaesthesiol Scand 57:692–697CrossRefPubMed
12.
Zurück zum Zitat Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:1740–1746PubMed Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med 30:1740–1746PubMed
13.
Zurück zum Zitat Belloni L, Pisano A, Natale A, Piccirillo MR, Piazza L, Ismeno G, De Martino G (2008) Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter. J Cardiothorac Vasc Anesth 22:243–248CrossRefPubMed Belloni L, Pisano A, Natale A, Piccirillo MR, Piazza L, Ismeno G, De Martino G (2008) Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter. J Cardiothorac Vasc Anesth 22:243–248CrossRefPubMed
14.
Zurück zum Zitat Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989CrossRefPubMed Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A (2001) Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 92:984–989CrossRefPubMed
15.
Zurück zum Zitat Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F (2008) Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 101:761–768CrossRefPubMed Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F (2008) Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 101:761–768CrossRefPubMed
16.
Zurück zum Zitat Broch O, Bein B, Gruenewald M, Hocker J, Schottler J, Meybohm P, Steinfath M, Renner J (2011) Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index. Acta Anaesthesiol Scand 55:686–693CrossRefPubMed Broch O, Bein B, Gruenewald M, Hocker J, Schottler J, Meybohm P, Steinfath M, Renner J (2011) Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index. Acta Anaesthesiol Scand 55:686–693CrossRefPubMed
17.
Zurück zum Zitat Broch O, Renner J, Gruenewald M, Meybohm P, Hocker J, Schottler J, Steinfath M, Bein B (2012) Variation of left ventricular outflow tract velocity and global end-diastolic volume index reliably predict fluid responsiveness in cardiac surgery patients. J Crit Care 27:325.e7–325.e13CrossRef Broch O, Renner J, Gruenewald M, Meybohm P, Hocker J, Schottler J, Steinfath M, Bein B (2012) Variation of left ventricular outflow tract velocity and global end-diastolic volume index reliably predict fluid responsiveness in cardiac surgery patients. J Crit Care 27:325.e7–325.e13CrossRef
18.
Zurück zum Zitat Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O, Bastien O, Lehot JJ (2007) Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. Anesthesiology 106:1105–1111CrossRefPubMed Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O, Bastien O, Lehot JJ (2007) Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. Anesthesiology 106:1105–1111CrossRefPubMed
19.
Zurück zum Zitat Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B (2011) Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a “gray zone” approach. Anesthesiology 115:231–241CrossRefPubMed Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B (2011) Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a “gray zone” approach. Anesthesiology 115:231–241CrossRefPubMed
20.
Zurück zum Zitat Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, Lehot JJ (2009) The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 108:513–517CrossRefPubMed Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, Lehot JJ (2009) The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 108:513–517CrossRefPubMed
21.
Zurück zum Zitat Cecconi M, Monti G, Hamilton MA, Puntis M, Dawson D, Tuccillo ML, Della Rocca G, Grounds RM, Rhodes A (2012) Efficacy of functional hemodynamic parameters in predicting fluid responsiveness with pulse power analysis in surgical patients. Minerva Anestesiol 78:527–533PubMed Cecconi M, Monti G, Hamilton MA, Puntis M, Dawson D, Tuccillo ML, Della Rocca G, Grounds RM, Rhodes A (2012) Efficacy of functional hemodynamic parameters in predicting fluid responsiveness with pulse power analysis in surgical patients. Minerva Anestesiol 78:527–533PubMed
22.
Zurück zum Zitat de Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF (2009) Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 37:510–515CrossRefPubMed de Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF (2009) Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 37:510–515CrossRefPubMed
23.
Zurück zum Zitat Desgranges FP, Desebbe O, Ghazouani A, Gilbert K, Keller G, Chiari P, Robin J, Bastien O, Lehot JJ, Cannesson M (2011) Influence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsiveness. Br J Anaesth 107:329–335CrossRefPubMed Desgranges FP, Desebbe O, Ghazouani A, Gilbert K, Keller G, Chiari P, Robin J, Bastien O, Lehot JJ, Cannesson M (2011) Influence of the site of measurement on the ability of plethysmographic variability index to predict fluid responsiveness. Br J Anaesth 107:329–335CrossRefPubMed
24.
Zurück zum Zitat Fischer MO, Pelissier A, Bohadana D, Gerard JL, Hanouz JL, Fellahi JL (2013) Prediction of responsiveness to an intravenous fluid challenge in patients after cardiac surgery with cardiopulmonary bypass: a comparison between arterial pulse pressure variation and digital plethysmographic variability index. J Cardiothorac Vasc Anesth 27:1087–1093CrossRefPubMed Fischer MO, Pelissier A, Bohadana D, Gerard JL, Hanouz JL, Fellahi JL (2013) Prediction of responsiveness to an intravenous fluid challenge in patients after cardiac surgery with cardiopulmonary bypass: a comparison between arterial pulse pressure variation and digital plethysmographic variability index. J Cardiothorac Vasc Anesth 27:1087–1093CrossRefPubMed
25.
Zurück zum Zitat Geerts BF, Aarts LP, Groeneveld AB, Jansen JR (2011) Predicting cardiac output responses to passive leg raising by a PEEP-induced increase in central venous pressure, in cardiac surgery patients. Br J Anaesth 107:150–156CrossRefPubMed Geerts BF, Aarts LP, Groeneveld AB, Jansen JR (2011) Predicting cardiac output responses to passive leg raising by a PEEP-induced increase in central venous pressure, in cardiac surgery patients. Br J Anaesth 107:150–156CrossRefPubMed
26.
Zurück zum Zitat Heijmans JH, Ganushak YM, Theunissen MS, Maessen JG, Roekaerts PJ (2010) Predictors of cardiac responsiveness to fluid therapy after cardiac surgery. Acta Anaesthesiol Belg 61:151–158PubMed Heijmans JH, Ganushak YM, Theunissen MS, Maessen JG, Roekaerts PJ (2010) Predictors of cardiac responsiveness to fluid therapy after cardiac surgery. Acta Anaesthesiol Belg 61:151–158PubMed
27.
Zurück zum Zitat Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH (2008) Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med 36:2810–2816CrossRefPubMed Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH (2008) Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med 36:2810–2816CrossRefPubMed
28.
Zurück zum Zitat Keller G, Sinavsky K, Desebbe O, Lehot JJ (2012) Combination of continuous pulse pressure variation monitoring and cardiac filling pressure to predict fluid responsiveness. J Clin Monit Comput 26:401–405CrossRefPubMed Keller G, Sinavsky K, Desebbe O, Lehot JJ (2012) Combination of continuous pulse pressure variation monitoring and cardiac filling pressure to predict fluid responsiveness. J Clin Monit Comput 26:401–405CrossRefPubMed
29.
Zurück zum Zitat Kramer A, Zygun D, Hawes H, Easton P, Ferland A (2004) Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest 126:1563–1568CrossRefPubMed Kramer A, Zygun D, Hawes H, Easton P, Ferland A (2004) Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest 126:1563–1568CrossRefPubMed
30.
Zurück zum Zitat Lakhal K, Ehrmann S, Benzekri-Lefevre D, Runge I, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T (2011) Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndrome. Crit Care 15:R85CrossRefPubMedPubMedCentral Lakhal K, Ehrmann S, Benzekri-Lefevre D, Runge I, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T (2011) Respiratory pulse pressure variation fails to predict fluid responsiveness in acute respiratory distress syndrome. Crit Care 15:R85CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Lakhal K, Ehrmann S, Runge I, Benzekri-Lefevre D, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T (2010) Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness. Intensive Care Med 36:940–948CrossRefPubMed Lakhal K, Ehrmann S, Runge I, Benzekri-Lefevre D, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T (2010) Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness. Intensive Care Med 36:940–948CrossRefPubMed
32.
Zurück zum Zitat Lee JH, Jeon Y, Bahk JH, Gil NS, Kim KB, Hong DM, Kim HJ (2011) Pulse-pressure variation predicts fluid responsiveness during heart displacement for off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth 25:1056–1062CrossRefPubMed Lee JH, Jeon Y, Bahk JH, Gil NS, Kim KB, Hong DM, Kim HJ (2011) Pulse-pressure variation predicts fluid responsiveness during heart displacement for off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth 25:1056–1062CrossRefPubMed
33.
Zurück zum Zitat Lee JH, Kim JT, Yoon SZ, Lim YJ, Jeon Y, Bahk JH, Kim CS (2007) Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 99:343–348CrossRefPubMed Lee JH, Kim JT, Yoon SZ, Lim YJ, Jeon Y, Bahk JH, Kim CS (2007) Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 99:343–348CrossRefPubMed
34.
Zurück zum Zitat Mahjoub Y, Benoit-Fallet H, Airapetian N, Lorne E, Levrard M, Seydi AA, Amennouche N, Slama M, Dupont H (2012) Improvement of left ventricular relaxation as assessed by tissue Doppler imaging in fluid-responsive critically ill septic patients. Intensive Care Med 38:1461–1470CrossRefPubMed Mahjoub Y, Benoit-Fallet H, Airapetian N, Lorne E, Levrard M, Seydi AA, Amennouche N, Slama M, Dupont H (2012) Improvement of left ventricular relaxation as assessed by tissue Doppler imaging in fluid-responsive critically ill septic patients. Intensive Care Med 38:1461–1470CrossRefPubMed
35.
Zurück zum Zitat Monge Garcia MI, Gil Cano A, Diaz Monrove JC (2009) Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Crit Care 13:R142CrossRefPubMedPubMedCentral Monge Garcia MI, Gil Cano A, Diaz Monrove JC (2009) Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients. Crit Care 13:R142CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Moretti R, Pizzi B (2010) Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage. Neurocrit Care 13:3–9CrossRefPubMed Moretti R, Pizzi B (2010) Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage. Neurocrit Care 13:3–9CrossRefPubMed
37.
Zurück zum Zitat Muller L, Louart G, Bengler C, Fabbro-Peray P, Carr J, Ripart J, de La Coussaye JE, Lefrant JY (2008) The intrathoracic blood volume index as an indicator of fluid responsiveness in critically ill patients with acute circulatory failure: a comparison with central venous pressure. Anesth Analg 107:607–613CrossRefPubMed Muller L, Louart G, Bengler C, Fabbro-Peray P, Carr J, Ripart J, de La Coussaye JE, Lefrant JY (2008) The intrathoracic blood volume index as an indicator of fluid responsiveness in critically ill patients with acute circulatory failure: a comparison with central venous pressure. Anesth Analg 107:607–613CrossRefPubMed
38.
Zurück zum Zitat Muller L, Louart G, Bousquet PJ, Candela D, Zoric L, de La Coussaye JE, Jaber S, Lefrant JY (2010) The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med 36:496–503CrossRefPubMed Muller L, Louart G, Bousquet PJ, Candela D, Zoric L, de La Coussaye JE, Jaber S, Lefrant JY (2010) The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med 36:496–503CrossRefPubMed
39.
Zurück zum Zitat Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, Zoric L, Suehs C, de La Coussaye JE, Molinari N, Lefrant JY (2011) An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology 115:541–547CrossRefPubMed Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, Zoric L, Suehs C, de La Coussaye JE, Molinari N, Lefrant JY (2011) An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology 115:541–547CrossRefPubMed
40.
Zurück zum Zitat Oliveira-Costa CD, Friedman G, Vieira SR, Fialkow L (2012) Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes. Clinics (Sao Paulo) 67:773–778CrossRef Oliveira-Costa CD, Friedman G, Vieira SR, Fialkow L (2012) Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes. Clinics (Sao Paulo) 67:773–778CrossRef
41.
Zurück zum Zitat Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL (2007) Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 35:64–68CrossRefPubMed Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL (2007) Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 35:64–68CrossRefPubMed
42.
Zurück zum Zitat Perel A, Minkovich L, Preisman S, Abiad M, Segal E, Coriat P (2005) Assessing fluid-responsiveness by a standardized ventilatory maneuver: the respiratory systolic variation test. Anesth Analg 100:942–945CrossRefPubMed Perel A, Minkovich L, Preisman S, Abiad M, Segal E, Coriat P (2005) Assessing fluid-responsiveness by a standardized ventilatory maneuver: the respiratory systolic variation test. Anesth Analg 100:942–945CrossRefPubMed
43.
Zurück zum Zitat Preisman S, Kogan S, Berkenstadt H, Perel A (2005) Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators. Br J Anaesth 95:746–755CrossRefPubMed Preisman S, Kogan S, Berkenstadt H, Perel A (2005) Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators. Br J Anaesth 95:746–755CrossRefPubMed
44.
Zurück zum Zitat Roy S, Couture P, Qizilbash B, Toupin F, Levesque S, Carrier M, Lambert J, Denault AY (2013) Hemodynamic pressure waveform analysis in predicting fluid responsiveness. J Cardiothorac Vasc Anesth 27:676–680CrossRefPubMed Roy S, Couture P, Qizilbash B, Toupin F, Levesque S, Carrier M, Lambert J, Denault AY (2013) Hemodynamic pressure waveform analysis in predicting fluid responsiveness. J Cardiothorac Vasc Anesth 27:676–680CrossRefPubMed
45.
Zurück zum Zitat Shin YH, Ko JS, Gwak MS, Kim GS, Lee JH, Lee SK (2011) Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation. Liver Transpl 17:53–59CrossRefPubMed Shin YH, Ko JS, Gwak MS, Kim GS, Lee JH, Lee SK (2011) Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation. Liver Transpl 17:53–59CrossRefPubMed
46.
Zurück zum Zitat Trof RJ, Danad I, Groeneveld AJ (2013) Global end-diastolic volume increases to maintain fluid responsiveness in sepsis-induced systolic dysfunction. BMC Anesthesiol 13:12CrossRefPubMedPubMedCentral Trof RJ, Danad I, Groeneveld AJ (2013) Global end-diastolic volume increases to maintain fluid responsiveness in sepsis-induced systolic dysfunction. BMC Anesthesiol 13:12CrossRefPubMedPubMedCentral
47.
Zurück zum Zitat Trof RJ, Danad I, Reilingh MW, Breukers RM, Groeneveld AB (2011) Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function. Crit Care 15:R73CrossRefPubMedPubMedCentral Trof RJ, Danad I, Reilingh MW, Breukers RM, Groeneveld AB (2011) Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function. Crit Care 15:R73CrossRefPubMedPubMedCentral
48.
Zurück zum Zitat Wilkman E, Kuitunen A, Pettila V, Varpula M (2014) Fluid responsiveness predicted by elevation of PEEP in patients with septic shock. Acta Anaesthesiol Scand 58:27–35CrossRefPubMed Wilkman E, Kuitunen A, Pettila V, Varpula M (2014) Fluid responsiveness predicted by elevation of PEEP in patients with septic shock. Acta Anaesthesiol Scand 58:27–35CrossRefPubMed
49.
Zurück zum Zitat Wyffels PA, Durnez PJ, Helderweirt J, Stockman WM, De Kegel D (2007) Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients. Anesth Analg 105:448–452CrossRefPubMed Wyffels PA, Durnez PJ, Helderweirt J, Stockman WM, De Kegel D (2007) Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients. Anesth Analg 105:448–452CrossRefPubMed
50.
Zurück zum Zitat Yazigi A, Khoury E, Hlais S, Madi-Jebara S, Haddad F, Hayek G, Jabbour K (2012) Pulse pressure variation predicts fluid responsiveness in elderly patients after coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 26:387–390CrossRefPubMed Yazigi A, Khoury E, Hlais S, Madi-Jebara S, Haddad F, Hayek G, Jabbour K (2012) Pulse pressure variation predicts fluid responsiveness in elderly patients after coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 26:387–390CrossRefPubMed
51.
Zurück zum Zitat Calvin JE, Driedger AA, Sibbald WJ (1981) The hemodynamic effect of rapid fluid infusion in critically ill patients. Surgery 90:61–76PubMed Calvin JE, Driedger AA, Sibbald WJ (1981) The hemodynamic effect of rapid fluid infusion in critically ill patients. Surgery 90:61–76PubMed
52.
Zurück zum Zitat Fischer MO, Balaire X, Mauff Le, de Kergal C, Boisselier C, Gerard JL, Hanouz JL, Fellahi JL (2014) The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography. Can J Anaesth 61:19–26CrossRefPubMed Fischer MO, Balaire X, Mauff Le, de Kergal C, Boisselier C, Gerard JL, Hanouz JL, Fellahi JL (2014) The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography. Can J Anaesth 61:19–26CrossRefPubMed
53.
Zurück zum Zitat Hu B, Xiang H, Liang H, Yu L, Xu T, Yang JH, Du ZH, Li JG (2013) Assessment effect of central venous pressure in fluid resuscitation in the patients with shock: a multi-center retrospective research. Chin Med J (Engl) 126:1844–1849 Hu B, Xiang H, Liang H, Yu L, Xu T, Yang JH, Du ZH, Li JG (2013) Assessment effect of central venous pressure in fluid resuscitation in the patients with shock: a multi-center retrospective research. Chin Med J (Engl) 126:1844–1849
54.
Zurück zum Zitat Magder S, Bafaqeeh F (2007) The clinical role of central venous pressure measurements. J Intensive Care Med 22:44–51CrossRefPubMed Magder S, Bafaqeeh F (2007) The clinical role of central venous pressure measurements. J Intensive Care Med 22:44–51CrossRefPubMed
55.
Zurück zum Zitat Saugel B, Kirsche SV, Hapfelmeier A, Phillip V, Schultheiss C, Schmid RM, Huber W (2013) Prediction of fluid responsiveness in patients admitted to the medical intensive care unit. J Crit Care 28:537.e531–537.e539 Saugel B, Kirsche SV, Hapfelmeier A, Phillip V, Schultheiss C, Schmid RM, Huber W (2013) Prediction of fluid responsiveness in patients admitted to the medical intensive care unit. J Crit Care 28:537.e531–537.e539
56.
Zurück zum Zitat Sturgess DJ, Pascoe RL, Scalia G, Venkatesh B (2010) A comparison of transcutaneous Doppler corrected flow time, b-type natriuretic peptide and central venous pressure as predictors of fluid responsiveness in septic shock: a preliminary evaluation. Anaesth Intensive Care 38:336–341CrossRefPubMed Sturgess DJ, Pascoe RL, Scalia G, Venkatesh B (2010) A comparison of transcutaneous Doppler corrected flow time, b-type natriuretic peptide and central venous pressure as predictors of fluid responsiveness in septic shock: a preliminary evaluation. Anaesth Intensive Care 38:336–341CrossRefPubMed
57.
Zurück zum Zitat Thiel SW, Kollef MH, Isakow W (2009) Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study. Crit Care 13:R111CrossRefPubMedPubMedCentral Thiel SW, Kollef MH, Isakow W (2009) Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study. Crit Care 13:R111CrossRefPubMedPubMedCentral
58.
Zurück zum Zitat Velissaris D, Pierrakos C, Scolletta S, De Backer D, Vincent JL (2011) High mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients. Crit Care 15:R177CrossRefPubMedPubMedCentral Velissaris D, Pierrakos C, Scolletta S, De Backer D, Vincent JL (2011) High mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients. Crit Care 15:R177CrossRefPubMedPubMedCentral
59.
Zurück zum Zitat Yu T, Pan C, Guo FM, Yang Y, Qiu HB (2013) Changes in arterial blood pressure induced by passive leg raising predict hypotension during the induction of sedation in critically ill patients without severe cardiac dysfunction. Chin Med J (Engl) 126:2445–2450 Yu T, Pan C, Guo FM, Yang Y, Qiu HB (2013) Changes in arterial blood pressure induced by passive leg raising predict hypotension during the induction of sedation in critically ill patients without severe cardiac dysfunction. Chin Med J (Engl) 126:2445–2450
60.
Zurück zum Zitat Monge Garcia MI, Gil Cano A, Diaz Monrove JC (2009) Arterial pressure changes during the valsalva maneuver to predict fluid responsiveness in spontaneously breathing patients. Intensive Care Med 35:77–84CrossRefPubMed Monge Garcia MI, Gil Cano A, Diaz Monrove JC (2009) Arterial pressure changes during the valsalva maneuver to predict fluid responsiveness in spontaneously breathing patients. Intensive Care Med 35:77–84CrossRefPubMed
61.
Zurück zum Zitat Cecconi M, Aya HD, Geisen M, Ebm C, Fletcher N, Grounds RM, Rhodes A (2013) Changes in the mean systemic filling pressure during a fluid challenge in postsurgical intensive care patients. Intensive Care Med 39:1299–1305CrossRefPubMed Cecconi M, Aya HD, Geisen M, Ebm C, Fletcher N, Grounds RM, Rhodes A (2013) Changes in the mean systemic filling pressure during a fluid challenge in postsurgical intensive care patients. Intensive Care Med 39:1299–1305CrossRefPubMed
62.
Zurück zum Zitat Lanspa MJ, Brown SM, Hirshberg EL, Jones JP, Grissom CK (2012) Central venous pressure and shock index predict lack of hemodynamic response to volume expansion in septic shock: a prospective, observational study. J Crit Care 27:609–615CrossRefPubMedPubMedCentral Lanspa MJ, Brown SM, Hirshberg EL, Jones JP, Grissom CK (2012) Central venous pressure and shock index predict lack of hemodynamic response to volume expansion in septic shock: a prospective, observational study. J Crit Care 27:609–615CrossRefPubMedPubMedCentral
63.
Zurück zum Zitat Hamzaoui O, Monnet X, Teboul JL (2015) Evolving concepts of hemodynamic monitoring for critically ill patients. Indian J Crit Care Med 19:220–226CrossRefPubMedPubMedCentral Hamzaoui O, Monnet X, Teboul JL (2015) Evolving concepts of hemodynamic monitoring for critically ill patients. Indian J Crit Care Med 19:220–226CrossRefPubMedPubMedCentral
64.
Zurück zum Zitat Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, Veber B, Paugam-Burtz C, Jaber S, Ayham A, Zogheib E, Lasocki S, Vieillard-Baron A, Quintard H, Joannes-Boyau O, Plantefeve G, Montravers P, Duperret S, Lakhdari M, Ammenouche N, Lorne E, Slama M, Dupont H (2014) Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study. Br J Anaesth 112:681–685CrossRefPubMed Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, Veber B, Paugam-Burtz C, Jaber S, Ayham A, Zogheib E, Lasocki S, Vieillard-Baron A, Quintard H, Joannes-Boyau O, Plantefeve G, Montravers P, Duperret S, Lakhdari M, Ammenouche N, Lorne E, Slama M, Dupont H (2014) Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study. Br J Anaesth 112:681–685CrossRefPubMed
65.
Zurück zum Zitat Marik PE, Lemson J (2014) Fluid responsiveness: an evolution of our understanding. Br J Anaesth 112:617–620CrossRefPubMed Marik PE, Lemson J (2014) Fluid responsiveness: an evolution of our understanding. Br J Anaesth 112:617–620CrossRefPubMed
66.
67.
Zurück zum Zitat Perner A, Vieillard-Baron A, Bakker J (2015) Fluid resuscitation in ICU patients: quo vadis? Intensive Care Med 41:1667–1669CrossRefPubMed Perner A, Vieillard-Baron A, Bakker J (2015) Fluid resuscitation in ICU patients: quo vadis? Intensive Care Med 41:1667–1669CrossRefPubMed
Metadaten
Titel
Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness
verfasst von
T. G. Eskesen
M. Wetterslev
A. Perner
Publikationsdatum
01.03.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Intensive Care Medicine / Ausgabe 3/2016
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-015-4168-4

Weitere Artikel der Ausgabe 3/2016

Intensive Care Medicine 3/2016 Zur Ausgabe

Imaging in Intensive Care Medicine

Keep an ear to the ground, the answer’s behind

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.