Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2016

06.09.2016 | Knee

Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis

verfasst von: Jelle P. van der List, Harshvardhan Chawla, Leo Joskowicz, Andrew D. Pearle

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 11/2016

Einloggen, um Zugang zu erhalten

Abstract

Recently, there is a growing interest in surgical variables that are intraoperatively controlled by orthopaedic surgeons, including lower leg alignment, component positioning and soft tissues balancing. Since more tight control over these factors is associated with improved outcomes of unicompartmental knee arthroplasty and total knee arthroplasty (TKA), several computer navigation and robotic-assisted systems have been developed. Although mechanical axis accuracy and component positioning have been shown to improve with computer navigation, no superiority in functional outcomes has yet been shown. This could be explained by the fact that many differences exist between the number and type of surgical variables these systems control. Most systems control lower leg alignment and component positioning, while some in addition control soft tissue balancing. Finally, robotic-assisted systems have the additional advantage of improving surgical precision. A systematic search in PubMed, Embase and Cochrane Library resulted in 40 comparative studies and three registries on computer navigation reporting outcomes of 474,197 patients, and 21 basic science and clinical studies on robotic-assisted knee arthroplasty. Twenty-eight of these comparative computer navigation studies reported Knee Society Total scores in 3504 patients. Stratifying by type of surgical variables, no significant differences were noted in outcomes between surgery with computer-navigated TKA controlling for alignment and component positioning versus conventional TKA (p = 0.63). However, significantly better outcomes were noted following computer-navigated TKA that also controlled for soft tissue balancing versus conventional TKA (mean difference 4.84, 95 % Confidence Interval 1.61, 8.07, p = 0.003). A literature review of robotic systems showed that these systems can, similarly to computer navigation, reliably improve lower leg alignment, component positioning and soft tissues balancing. Furthermore, two studies comparing robotic-assisted with computer-navigated surgery reported superiority of robotic-assisted surgery in controlling these factors. Manually controlling all these surgical variables can be difficult for the orthopaedic surgeon. Findings in this study suggest that computer navigation or robotic assistance may help managing these multiple variables and could improve outcomes. Future studies assessing the role of soft tissue balancing in knee arthroplasty and long-term follow-up studies assessing the role of computer-navigated and robotic-assisted knee arthroplasty are needed.
Literatur
1.
Zurück zum Zitat Alcelik IA, Blomfield MI, Diana G, Gibbon AJ, Carrington N, Burr S (2016) A comparison of short-term outcomes of minimally invasive computer-assisted vs minimally invasive conventional instrumentation for primary total knee arthroplasty: a systematic review and meta-analysis. J Arthroplasty 31(2):410–418PubMedCrossRef Alcelik IA, Blomfield MI, Diana G, Gibbon AJ, Carrington N, Burr S (2016) A comparison of short-term outcomes of minimally invasive computer-assisted vs minimally invasive conventional instrumentation for primary total knee arthroplasty: a systematic review and meta-analysis. J Arthroplasty 31(2):410–418PubMedCrossRef
4.
Zurück zum Zitat Atkins D, Best D, Briss PA, Eccles M, Falck-Ytter Y, Flottorp S, Guyatt GH, Harbour RT, Haugh MC, Henry D, Hill S, Jaeschke R, Leng G, Liberati A, Magrini N, Mason J, Middleton P, Mrukowicz J, O’Connell D, Oxman AD, Phillips B, Schunemann HJ, Edejer T, Varonen H, Vist GE, Williams JW Jr, Zaza S (2004) Grading quality of evidence and strength of recommendations. BMJ 328(7454):1490PubMedCrossRef Atkins D, Best D, Briss PA, Eccles M, Falck-Ytter Y, Flottorp S, Guyatt GH, Harbour RT, Haugh MC, Henry D, Hill S, Jaeschke R, Leng G, Liberati A, Magrini N, Mason J, Middleton P, Mrukowicz J, O’Connell D, Oxman AD, Phillips B, Schunemann HJ, Edejer T, Varonen H, Vist GE, Williams JW Jr, Zaza S (2004) Grading quality of evidence and strength of recommendations. BMJ 328(7454):1490PubMedCrossRef
5.
Zurück zum Zitat Attfield SF, Wilton TJ, Pratt DJ, Sambatakakis A (1996) Soft-tissue balance and recovery of proprioception after total knee replacement. J Bone Joint Surg Br 78(4):540–545PubMed Attfield SF, Wilton TJ, Pratt DJ, Sambatakakis A (1996) Soft-tissue balance and recovery of proprioception after total knee replacement. J Bone Joint Surg Br 78(4):540–545PubMed
6.
Zurück zum Zitat Babazadeh S, Stoney JD, Lim K, Choong PF (2009) The relevance of ligament balancing in total knee arthroplasty: how important is it? A systematic review of the literature. Orthop Rev (Pavia) 1(2):e26CrossRef Babazadeh S, Stoney JD, Lim K, Choong PF (2009) The relevance of ligament balancing in total knee arthroplasty: how important is it? A systematic review of the literature. Orthop Rev (Pavia) 1(2):e26CrossRef
7.
Zurück zum Zitat Barbadoro P, Ensini A, Leardini A, d’Amato M, Feliciangeli A, Timoncini A, Amadei F, Belvedere C, Giannini S (2014) Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study. Knee Surg Sports Traumatol Arthrosc 22(12):3157–3162PubMedCrossRef Barbadoro P, Ensini A, Leardini A, d’Amato M, Feliciangeli A, Timoncini A, Amadei F, Belvedere C, Giannini S (2014) Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study. Knee Surg Sports Traumatol Arthrosc 22(12):3157–3162PubMedCrossRef
8.
Zurück zum Zitat Barink M, Verdonschot N, de Waal Malefijt M (2003) A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock. Proc Inst Mech Eng H 217(5):325–332PubMedCrossRef Barink M, Verdonschot N, de Waal Malefijt M (2003) A different fixation of the femoral component in total knee arthroplasty may lead to preservation of femoral bone stock. Proc Inst Mech Eng H 217(5):325–332PubMedCrossRef
9.
Zurück zum Zitat Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplasty 26(8):1273–1284PubMedCrossRef Barrett WP, Mason JB, Moskal JT, Dalury DF, Oliashirazi A, Fisher DA (2011) Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty. J Arthroplasty 26(8):1273–1284PubMedCrossRef
10.
Zurück zum Zitat Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement: a meta-analysis. J Bone Joint Surg Am 89(2):261–269PubMed Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement: a meta-analysis. J Bone Joint Surg Am 89(2):261–269PubMed
11.
Zurück zum Zitat Bellemans J, Vandenneucker H, Vanlauwe J (2007) Robot-assisted total knee arthroplasty. Clin Orthop Relat Res 464:111–116PubMed Bellemans J, Vandenneucker H, Vanlauwe J (2007) Robot-assisted total knee arthroplasty. Clin Orthop Relat Res 464:111–116PubMed
12.
Zurück zum Zitat Bin Abd Razak HR, Yeo Jin S, Chong Chi H (2014) Computer navigation results in less severe flexion contracture following total knee arthroplasty. J Arthroplasty 29(12):2369–2372PubMedCrossRef Bin Abd Razak HR, Yeo Jin S, Chong Chi H (2014) Computer navigation results in less severe flexion contracture following total knee arthroplasty. J Arthroplasty 29(12):2369–2372PubMedCrossRef
13.
Zurück zum Zitat Bonnin MP, Saffarini M, Shepherd D, Bossard N, Dantony E (2015) Oversizing the tibial component in TKAs: incidence, consequences and risk factors. Knee Surg Sports Traumatol Arthrosc 24(8):2532–2540PubMedCrossRef Bonnin MP, Saffarini M, Shepherd D, Bossard N, Dantony E (2015) Oversizing the tibial component in TKAs: incidence, consequences and risk factors. Knee Surg Sports Traumatol Arthrosc 24(8):2532–2540PubMedCrossRef
14.
Zurück zum Zitat Bonnin MP, Schmidt A, Basiglini L, Bossard N, Dantony E (2013) Mediolateral oversizing influences pain, function, and flexion after TKA. Knee Surg Sports Traumatol Arthrosc 21(10):2314–2324PubMedPubMedCentralCrossRef Bonnin MP, Schmidt A, Basiglini L, Bossard N, Dantony E (2013) Mediolateral oversizing influences pain, function, and flexion after TKA. Knee Surg Sports Traumatol Arthrosc 21(10):2314–2324PubMedPubMedCentralCrossRef
15.
Zurück zum Zitat Bonutti PM, Dethmers D, Ulrich SD, Seyler TM, Mont MA (2008) Computer navigation-assisted versus minimally invasive TKA: benefits and drawbacks. Clin Orthop Relat Res 466(11):2756–2762PubMedPubMedCentralCrossRef Bonutti PM, Dethmers D, Ulrich SD, Seyler TM, Mont MA (2008) Computer navigation-assisted versus minimally invasive TKA: benefits and drawbacks. Clin Orthop Relat Res 466(11):2756–2762PubMedPubMedCentralCrossRef
16.
Zurück zum Zitat Borenstein M, Hedges LV, Higgins J, Rothstein HR (2009) Introduction to meta-analysis. Wiley, ChichesterCrossRef Borenstein M, Hedges LV, Higgins J, Rothstein HR (2009) Introduction to meta-analysis. Wiley, ChichesterCrossRef
17.
Zurück zum Zitat Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop 35(3):331–339PubMedCrossRef Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop 35(3):331–339PubMedCrossRef
18.
Zurück zum Zitat Burnett RS, Nair R, Hall CA, Jacks DA, Pugh L, McAllister MM (2014) Results of the Oxford Phase 3 mobile bearing medial unicompartmental knee arthroplasty from an independent center: 467 knees at a mean 6-year follow-up: analysis of predictors of failure. J Arthroplasty 29(9 Suppl):193–200PubMedCrossRef Burnett RS, Nair R, Hall CA, Jacks DA, Pugh L, McAllister MM (2014) Results of the Oxford Phase 3 mobile bearing medial unicompartmental knee arthroplasty from an independent center: 467 knees at a mean 6-year follow-up: analysis of predictors of failure. J Arthroplasty 29(9 Suppl):193–200PubMedCrossRef
19.
Zurück zum Zitat Centre of excellence of joint replacements (2010) The Norwegian arthroplasty register Centre of excellence of joint replacements (2010) The Norwegian arthroplasty register
20.
Zurück zum Zitat Chau R, Gulati A, Pandit H, Beard DJ, Price AJ, Dodd CA, Gill HS, Murray DW (2009) Tibial component overhang following unicompartmental knee replacement–does it matter? Knee 16(5):310–313PubMedCrossRef Chau R, Gulati A, Pandit H, Beard DJ, Price AJ, Dodd CA, Gill HS, Murray DW (2009) Tibial component overhang following unicompartmental knee replacement–does it matter? Knee 16(5):310–313PubMedCrossRef
21.
Zurück zum Zitat Cheng T, Pan XY, Mao X, Zhang GY, Zhang XL (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19(4):237–245PubMedCrossRef Cheng T, Pan XY, Mao X, Zhang GY, Zhang XL (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19(4):237–245PubMedCrossRef
22.
Zurück zum Zitat Cheng T, Zhang G, Zhang X (2011) Imageless navigation system does not improve component rotational alignment in total knee arthroplasty. J Orthop Surg Res 171(2):590–600 Cheng T, Zhang G, Zhang X (2011) Imageless navigation system does not improve component rotational alignment in total knee arthroplasty. J Orthop Surg Res 171(2):590–600
23.
Zurück zum Zitat Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20(7):1307–1322PubMedCrossRef Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc 20(7):1307–1322PubMedCrossRef
24.
Zurück zum Zitat Cip J, Widemschek M, Luegmair M, Sheinkop MB, Benesch T, Martin A (2014) Conventional versus computer-assisted technique for total knee arthroplasty: a minimum of 5-year follow-up of 200 patients in a prospective randomized comparative trial. J Arthroplasty 29(9):1795–1802PubMedCrossRef Cip J, Widemschek M, Luegmair M, Sheinkop MB, Benesch T, Martin A (2014) Conventional versus computer-assisted technique for total knee arthroplasty: a minimum of 5-year follow-up of 200 patients in a prospective randomized comparative trial. J Arthroplasty 29(9):1795–1802PubMedCrossRef
25.
Zurück zum Zitat Citak M, Suero EM, Citak M, Dunbar NJ, Branch SH, Conditt MA, Banks SA, Pearle AD (2013) Unicompartmental knee arthroplasty: is robotic technology more accurate than conventional technique? Knee 20(4):268–271PubMedCrossRef Citak M, Suero EM, Citak M, Dunbar NJ, Branch SH, Conditt MA, Banks SA, Pearle AD (2013) Unicompartmental knee arthroplasty: is robotic technology more accurate than conventional technique? Knee 20(4):268–271PubMedCrossRef
26.
Zurück zum Zitat Clark TC, Schmidt FH (2013) Robot-assisted navigation versus computer-assisted navigation in primary total knee arthroplasty: efficiency and accuracy. ISRN Orthop 2013:794827PubMedPubMedCentralCrossRef Clark TC, Schmidt FH (2013) Robot-assisted navigation versus computer-assisted navigation in primary total knee arthroplasty: efficiency and accuracy. ISRN Orthop 2013:794827PubMedPubMedCentralCrossRef
27.
Zurück zum Zitat Cobb J, Henckel J, Gomes P, Harris S, Jakopec M, Rodriguez F, Barrett A, Davies B (2006) Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg Br 88(2):188–197PubMedCrossRef Cobb J, Henckel J, Gomes P, Harris S, Jakopec M, Rodriguez F, Barrett A, Davies B (2006) Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg Br 88(2):188–197PubMedCrossRef
28.
Zurück zum Zitat Collier MB, Eickmann TH, Sukezaki F, McAuley JP, Engh GA (2006) Patient, implant, and alignment factors associated with revision of medial compartment unicondylar arthroplasty. J Arthroplasty 21(6 Suppl 2):108–115PubMedCrossRef Collier MB, Eickmann TH, Sukezaki F, McAuley JP, Engh GA (2006) Patient, implant, and alignment factors associated with revision of medial compartment unicondylar arthroplasty. J Arthroplasty 21(6 Suppl 2):108–115PubMedCrossRef
30.
Zurück zum Zitat Coon T, Roche M, Pearle AD, Dounchis J, Borus T, Buechel Jr F (2013) Two year survivorship of robotically guided unicompartmental knee arthroplasty. Paper presented at the ISTA 26th annual congress, Palm Beach, FL, USA Coon T, Roche M, Pearle AD, Dounchis J, Borus T, Buechel Jr F (2013) Two year survivorship of robotically guided unicompartmental knee arthroplasty. Paper presented at the ISTA 26th annual congress, Palm Beach, FL, USA
31.
Zurück zum Zitat De Steiger RN, Liu YL, Graves SE (2015) Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age. J Bone Joint Surg Am 97(8):635–642PubMedCrossRef De Steiger RN, Liu YL, Graves SE (2015) Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age. J Bone Joint Surg Am 97(8):635–642PubMedCrossRef
32.
Zurück zum Zitat Decking R, Markmann Y, Mattes T, Puhl W, Scharf HP (2007) On the outcome of computer-assisted total knee replacement. Acta Chir Orthop Traumatol Cech 74(3):171–174PubMed Decking R, Markmann Y, Mattes T, Puhl W, Scharf HP (2007) On the outcome of computer-assisted total knee replacement. Acta Chir Orthop Traumatol Cech 74(3):171–174PubMed
33.
Zurück zum Zitat Dobzyniak M, Fehring TK, Odum S (2006) Early failure in total hip arthroplasty. Clin Orthop Relat Res 447:76–78PubMedCrossRef Dobzyniak M, Fehring TK, Odum S (2006) Early failure in total hip arthroplasty. Clin Orthop Relat Res 447:76–78PubMedCrossRef
34.
Zurück zum Zitat Dunbar NJ, Roche MW, Park BH, Branch SH, Conditt MA, Banks SA (2012) Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty. J Arthroplasty 27(5):803–808PubMedCrossRef Dunbar NJ, Roche MW, Park BH, Branch SH, Conditt MA, Banks SA (2012) Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty. J Arthroplasty 27(5):803–808PubMedCrossRef
35.
Zurück zum Zitat Eagar P, Hull ML, Howell SM (2004) How the fixation method stiffness and initial tension affect anterior load-displacement of the knee and tension in anterior cruciate ligament grafts: a study in cadaveric knees using a double-loop hamstrings graft. J Orthop Res 22(3):613–624PubMedCrossRef Eagar P, Hull ML, Howell SM (2004) How the fixation method stiffness and initial tension affect anterior load-displacement of the knee and tension in anterior cruciate ligament grafts: a study in cadaveric knees using a double-loop hamstrings graft. J Orthop Res 22(3):613–624PubMedCrossRef
36.
Zurück zum Zitat Ek ET, Dowsey MM, Tse LF, Riazi A, Love BR, Stoney JD, Choong PF (2008) Comparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study. J Orthop Surg (Hong Kong) 16(2):192–196CrossRef Ek ET, Dowsey MM, Tse LF, Riazi A, Love BR, Stoney JD, Choong PF (2008) Comparison of functional and radiological outcomes after computer-assisted versus conventional total knee arthroplasty: a matched-control retrospective study. J Orthop Surg (Hong Kong) 16(2):192–196CrossRef
37.
Zurück zum Zitat Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M (2001) Early failures in total knee arthroplasty. Clin Orthop Relat Res 392:315–318CrossRef Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M (2001) Early failures in total knee arthroplasty. Clin Orthop Relat Res 392:315–318CrossRef
38.
Zurück zum Zitat Fricka KB, Sritulanondha S, McAsey CJ (2015) To cement or not? Two-year results of a prospective, randomized study comparing cemented vs. cementless total knee arthroplasty (TKA). J Arthroplasty 30(9 Suppl):55–58PubMedCrossRef Fricka KB, Sritulanondha S, McAsey CJ (2015) To cement or not? Two-year results of a prospective, randomized study comparing cemented vs. cementless total knee arthroplasty (TKA). J Arthroplasty 30(9 Suppl):55–58PubMedCrossRef
39.
Zurück zum Zitat Fu Y, Wang M, Liu Y, Fu Q (2012) Alignment outcomes in navigated total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 20(6):1075–1082PubMedCrossRef Fu Y, Wang M, Liu Y, Fu Q (2012) Alignment outcomes in navigated total knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 20(6):1075–1082PubMedCrossRef
40.
Zurück zum Zitat Gioe TJ, Killeen KK, Grimm K, Mehle K, Scheltema K (2004) Why are total knee replacements revised? Clin Orthop Relat Res 428:100–106CrossRef Gioe TJ, Killeen KK, Grimm K, Mehle K, Scheltema K (2004) Why are total knee replacements revised? Clin Orthop Relat Res 428:100–106CrossRef
41.
Zurück zum Zitat Gøthesen O, Espehaug B, Havelin L, Petursson G, Furnes O (2011) Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008. Acta Orthop 82(3):293–300PubMedPubMedCentralCrossRef Gøthesen O, Espehaug B, Havelin L, Petursson G, Furnes O (2011) Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008. Acta Orthop 82(3):293–300PubMedPubMedCentralCrossRef
42.
Zurück zum Zitat Hansen DC, Kusuma SK, Palmer RM, Harris KB (2014) Robotic guidance does not improve component position or short-term outcome in medial unicompartmental knee arthroplasty. J Arthroplasty 29(9):1784–1789PubMedCrossRef Hansen DC, Kusuma SK, Palmer RM, Harris KB (2014) Robotic guidance does not improve component position or short-term outcome in medial unicompartmental knee arthroplasty. J Arthroplasty 29(9):1784–1789PubMedCrossRef
43.
Zurück zum Zitat Harvie P, Sloan K, Beaver RJ (2012) Computer navigation vs conventional total knee arthroplasty. Five-year functional results of a prospective randomized trial. J Arthroplasty 27(5):667–672PubMedCrossRef Harvie P, Sloan K, Beaver RJ (2012) Computer navigation vs conventional total knee arthroplasty. Five-year functional results of a prospective randomized trial. J Arthroplasty 27(5):667–672PubMedCrossRef
44.
Zurück zum Zitat Hasegawa M, Yoshida K, Wakabayashi H, Sudo A (2011) Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc 19(6):904–910PubMedCrossRef Hasegawa M, Yoshida K, Wakabayashi H, Sudo A (2011) Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc 19(6):904–910PubMedCrossRef
45.
Zurück zum Zitat Hernández-Vaquero D, Suarez-Vazquez A, Iglesias-Fernandez S (2011) Can computer assistance improve the clinical and functional scores in total knee arthroplasty? Clin Orthop Relat Res 469(12):3436–3442PubMedPubMedCentralCrossRef Hernández-Vaquero D, Suarez-Vazquez A, Iglesias-Fernandez S (2011) Can computer assistance improve the clinical and functional scores in total knee arthroplasty? Clin Orthop Relat Res 469(12):3436–3442PubMedPubMedCentralCrossRef
46.
Zurück zum Zitat Hetaimish BM, Khan MM, Simunovic N, Al-Harbi HH, Bhandari M, Zalzal PK (2012) Meta-analysis of navigation vs conventional total knee arthroplasty. J Arthroplasty 27(6):1177–1182PubMedCrossRef Hetaimish BM, Khan MM, Simunovic N, Al-Harbi HH, Bhandari M, Zalzal PK (2012) Meta-analysis of navigation vs conventional total knee arthroplasty. J Arthroplasty 27(6):1177–1182PubMedCrossRef
47.
Zurück zum Zitat Hoppe S, Mainzer JD, Frauchiger L, Ballmer PM, Hess R, Zumstein MA (2012) More accurate component alignment in navigated total knee arthroplasty has no clinical benefit at 5-year follow-up. Acta Orthop 83(6):629–633PubMedPubMedCentralCrossRef Hoppe S, Mainzer JD, Frauchiger L, Ballmer PM, Hess R, Zumstein MA (2012) More accurate component alignment in navigated total knee arthroplasty has no clinical benefit at 5-year follow-up. Acta Orthop 83(6):629–633PubMedPubMedCentralCrossRef
48.
Zurück zum Zitat Huang NF, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF (2012) Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplasty 27(9):1737–1741PubMedCrossRef Huang NF, Dowsey MM, Ee E, Stoney JD, Babazadeh S, Choong PF (2012) Coronal alignment correlates with outcome after total knee arthroplasty: five-year follow-up of a randomized controlled trial. J Arthroplasty 27(9):1737–1741PubMedCrossRef
49.
Zurück zum Zitat Huang TW, Lee CY, Lin SJ, Peng KT, Huang KC, Lee MS, Hsu RW, Shen WJ (2014) Comparison of computer-navigated and conventional total knee arthroplasty in patients with Ranawat type-II valgus deformity: medium-term clinical and radiological results. BMC Musculoskelet Disord 15:390PubMedPubMedCentralCrossRef Huang TW, Lee CY, Lin SJ, Peng KT, Huang KC, Lee MS, Hsu RW, Shen WJ (2014) Comparison of computer-navigated and conventional total knee arthroplasty in patients with Ranawat type-II valgus deformity: medium-term clinical and radiological results. BMC Musculoskelet Disord 15:390PubMedPubMedCentralCrossRef
50.
Zurück zum Zitat Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714PubMed
51.
Zurück zum Zitat Ji HM, Han J, Jin DS, Seo H, Won YY (2016) Kinematically aligned TKA can align knee joint line to horizontal. Knee Surg Sports Traumatol Arthrosc 24(8):2436–2441PubMedCrossRef Ji HM, Han J, Jin DS, Seo H, Won YY (2016) Kinematically aligned TKA can align knee joint line to horizontal. Knee Surg Sports Traumatol Arthrosc 24(8):2436–2441PubMedCrossRef
52.
Zurück zum Zitat Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570PubMedCrossRef Kamat YD, Aurakzai KM, Adhikari AR, Matthews D, Kalairajah Y, Field RE (2009) Does computer navigation in total knee arthroplasty improve patient outcome at midterm follow-up? Int Orthop 33(6):1567–1570PubMedCrossRef
53.
Zurück zum Zitat Kendrick BJ, Kaptein BL, Valstar ER, Gill HS, Jackson WF, Dodd CA, Price AJ, Murray DW (2015) Cemented versus cementless Oxford unicompartmental knee arthroplasty using radiostereometric analysis: a randomised controlled trial. Bone Joint J 97-B(2):185–191PubMedCrossRef Kendrick BJ, Kaptein BL, Valstar ER, Gill HS, Jackson WF, Dodd CA, Price AJ, Murray DW (2015) Cemented versus cementless Oxford unicompartmental knee arthroplasty using radiostereometric analysis: a randomised controlled trial. Bone Joint J 97-B(2):185–191PubMedCrossRef
54.
Zurück zum Zitat Khamaisy S, Zuiderbaan HA, van der List JP, Nam D, Pearle AD (2016) Medial unicompartmental knee arthroplasty improves congruence and restores joint space width of the lateral compartment. Knee 23(3):501–505PubMedCrossRef Khamaisy S, Zuiderbaan HA, van der List JP, Nam D, Pearle AD (2016) Medial unicompartmental knee arthroplasty improves congruence and restores joint space width of the lateral compartment. Knee 23(3):501–505PubMedCrossRef
55.
Zurück zum Zitat Kim SM, Park YS, Ha CW, Lim SJ, Moon YW (2012) Robot-assisted implantation improves the precision of component position in minimally invasive TKA. Orthopedics 35(9):e1334–e1339PubMedCrossRef Kim SM, Park YS, Ha CW, Lim SJ, Moon YW (2012) Robot-assisted implantation improves the precision of component position in minimally invasive TKA. Orthopedics 35(9):e1334–e1339PubMedCrossRef
56.
Zurück zum Zitat Kim TK, Chang CB, Kang YG, Chung BJ, Cho HJ, Seong SC (2010) Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty. Knee 17(1):23–28PubMedCrossRef Kim TK, Chang CB, Kang YG, Chung BJ, Cho HJ, Seong SC (2010) Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty. Knee 17(1):23–28PubMedCrossRef
57.
Zurück zum Zitat Kim YH, Park JW, Kim JS (2012) Computer-navigated versus conventional total knee arthroplasty: a prospective randomized trial. J Bone Joint Surg Am 94(22):2017–2024PubMedCrossRef Kim YH, Park JW, Kim JS (2012) Computer-navigated versus conventional total knee arthroplasty: a prospective randomized trial. J Bone Joint Surg Am 94(22):2017–2024PubMedCrossRef
58.
Zurück zum Zitat Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38(2):379–385PubMedCrossRef Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38(2):379–385PubMedCrossRef
59.
Zurück zum Zitat Konyves A, Willis-Owen CA, Spriggins AJ (2010) The long-term benefit of computer-assisted surgical navigation in unicompartmental knee arthroplasty. J Orthop Surg Res 5:94PubMedPubMedCentralCrossRef Konyves A, Willis-Owen CA, Spriggins AJ (2010) The long-term benefit of computer-assisted surgical navigation in unicompartmental knee arthroplasty. J Orthop Surg Res 5:94PubMedPubMedCentralCrossRef
60.
Zurück zum Zitat Koulalis D, O’Loughlin PF, Plaskos C, Kendoff D, Cross MB, Pearle AD (2011) Sequential versus automated cutting guides in computer-assisted total knee arthroplasty. Knee 18(6):436–442PubMedCrossRef Koulalis D, O’Loughlin PF, Plaskos C, Kendoff D, Cross MB, Pearle AD (2011) Sequential versus automated cutting guides in computer-assisted total knee arthroplasty. Knee 18(6):436–442PubMedCrossRef
61.
Zurück zum Zitat Labek G, Sekyra K, Pawelka W, Janda W, Stockl B (2011) Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: a structured literature review including arthroplasty registry data. Acta Orthop 82(2):131–135PubMedPubMedCentralCrossRef Labek G, Sekyra K, Pawelka W, Janda W, Stockl B (2011) Outcome and reproducibility of data concerning the Oxford unicompartmental knee arthroplasty: a structured literature review including arthroplasty registry data. Acta Orthop 82(2):131–135PubMedPubMedCentralCrossRef
62.
Zurück zum Zitat Lee WT, Chin PL, Lo NN, Yeo SJ (2015) Short-term outcome after computer-assisted versus conventional total knee arthroplasty: a randomised controlled trial. J Orthop Surg (Hong Kong) 23(1):71–75CrossRef Lee WT, Chin PL, Lo NN, Yeo SJ (2015) Short-term outcome after computer-assisted versus conventional total knee arthroplasty: a randomised controlled trial. J Orthop Surg (Hong Kong) 23(1):71–75CrossRef
63.
Zurück zum Zitat Lehnen K, Giesinger K, Warschkow R, Porter M, Koch E, Kuster MS (2011) Clinical outcome using a ligament referencing technique in CAS versus conventional technique. Knee Surg Sports Traumatol Arthrosc 19(6):887–892PubMedCrossRef Lehnen K, Giesinger K, Warschkow R, Porter M, Koch E, Kuster MS (2011) Clinical outcome using a ligament referencing technique in CAS versus conventional technique. Knee Surg Sports Traumatol Arthrosc 19(6):887–892PubMedCrossRef
64.
Zurück zum Zitat Lin SY, Chen CH, Fu YC, Huang PJ, Lu CC, Su JY, Chang JK, Huang HT (2013) Comparison of the clinical and radiological outcomes of three minimally invasive techniques for total knee replacement at two years. Bone Joint J 95(7):906–910PubMedCrossRef Lin SY, Chen CH, Fu YC, Huang PJ, Lu CC, Su JY, Chang JK, Huang HT (2013) Comparison of the clinical and radiological outcomes of three minimally invasive techniques for total knee replacement at two years. Bone Joint J 95(7):906–910PubMedCrossRef
65.
Zurück zum Zitat Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29(12):2373–2377PubMedCrossRef Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29(12):2373–2377PubMedCrossRef
66.
Zurück zum Zitat Liow MHL, Chin PL, Tay KJD, Chia SL, Lo NN, Yeo SJ (2014) Early experiences with robot-assisted total knee arthroplasty using the digiMatch™ ROBODOC® surgical system. Singapore Med J 55(10):529–534PubMedPubMedCentralCrossRef Liow MHL, Chin PL, Tay KJD, Chia SL, Lo NN, Yeo SJ (2014) Early experiences with robot-assisted total knee arthroplasty using the digiMatch™ ROBODOC® surgical system. Singapore Med J 55(10):529–534PubMedPubMedCentralCrossRef
67.
Zurück zum Zitat Lonner JH (2009) Robotic arm-assisted unicompartmental arthroplasty. Semin Arthroplasty 20(1):15–22CrossRef Lonner JH (2009) Robotic arm-assisted unicompartmental arthroplasty. Semin Arthroplasty 20(1):15–22CrossRef
68.
Zurück zum Zitat Lonner JH, John TK, Conditt MA (2010) Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 468(1):141–146PubMedCrossRef Lonner JH, John TK, Conditt MA (2010) Robotic arm-assisted UKA improves tibial component alignment: a pilot study. Clin Orthop Relat Res 468(1):141–146PubMedCrossRef
69.
Zurück zum Zitat Lonner JH, Smith JR, Picard F, Hamlin B, Rowe PJ, Riches PE (2015) High degree of accuracy of a novel image-free handheld robot for unicondylar knee arthroplasty in a cadaveric study. Clin Orthop Relat Res 473(1):206–212PubMedCrossRef Lonner JH, Smith JR, Picard F, Hamlin B, Rowe PJ, Riches PE (2015) High degree of accuracy of a novel image-free handheld robot for unicondylar knee arthroplasty in a cadaveric study. Clin Orthop Relat Res 473(1):206–212PubMedCrossRef
70.
Zurück zum Zitat Luring C, Kauper M, Bathis H, Perlick L, Beckmann J, Grifka J, Tingart M, Rath B (2012) A five to seven year follow-up comparing computer-assisted vs freehand TKR with regard to clinical parameters. Int Orthop 36(3):553–558PubMedCrossRef Luring C, Kauper M, Bathis H, Perlick L, Beckmann J, Grifka J, Tingart M, Rath B (2012) A five to seven year follow-up comparing computer-assisted vs freehand TKR with regard to clinical parameters. Int Orthop 36(3):553–558PubMedCrossRef
71.
Zurück zum Zitat Lutzner J, Dexel J, Kirschner S (2013) No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study. Knee Surg Sports Traumatol Arthrosc 21(10):2241–2247PubMedCrossRef Lutzner J, Dexel J, Kirschner S (2013) No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study. Knee Surg Sports Traumatol Arthrosc 21(10):2241–2247PubMedCrossRef
72.
Zurück zum Zitat MacCallum KP, Danoff JR, Geller JA (2016) Tibial baseplate positioning in robotic-assisted and conventional unicompartmental knee arthroplasty. Eur J Orthop Surg Traumatol 26(1):93–98PubMedCrossRef MacCallum KP, Danoff JR, Geller JA (2016) Tibial baseplate positioning in robotic-assisted and conventional unicompartmental knee arthroplasty. Eur J Orthop Surg Traumatol 26(1):93–98PubMedCrossRef
73.
Zurück zum Zitat Manzotti A, Cerveri P, Pullen C, Confalonieri N (2014) Computer-assisted unicompartmental knee arthroplasty using dedicated software versus a conventional technique. Int Orthop 38(2):457–463PubMedCrossRef Manzotti A, Cerveri P, Pullen C, Confalonieri N (2014) Computer-assisted unicompartmental knee arthroplasty using dedicated software versus a conventional technique. Int Orthop 38(2):457–463PubMedCrossRef
74.
Zurück zum Zitat Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22(8):1097–1106PubMedCrossRef Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty 22(8):1097–1106PubMedCrossRef
75.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89(2):236–243PubMed Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89(2):236–243PubMed
76.
Zurück zum Zitat Meijer MF, Reininga IH, Boerboom AL, Bulstra SK, Stevens M (2014) Does imageless computer-assisted TKA lead to improved rotational alignment or fewer outliers? A systematic review. Clin Orthop Relat Res 472(10):3124–3133PubMedPubMedCentralCrossRef Meijer MF, Reininga IH, Boerboom AL, Bulstra SK, Stevens M (2014) Does imageless computer-assisted TKA lead to improved rotational alignment or fewer outliers? A systematic review. Clin Orthop Relat Res 472(10):3124–3133PubMedPubMedCentralCrossRef
77.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6(7):e1000097PubMedPubMedCentralCrossRef Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6(7):e1000097PubMedPubMedCentralCrossRef
78.
Zurück zum Zitat Molfetta L, Caldo D (2008) Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up. Knee 15(2):75–79PubMedCrossRef Molfetta L, Caldo D (2008) Computer navigation versus conventional implantation for varus knee total arthroplasty: a case-control study at 5 years follow-up. Knee 15(2):75–79PubMedCrossRef
79.
Zurück zum Zitat Mont MA, Pivec R, Issa K, Kapadia BH, Maheshwari A, Harwin SF (2014) Long-term implant survivorship of cementless total knee arthroplasty: a systematic review of the literature and meta-analysis. J Knee Surg 27(5):369–376PubMed Mont MA, Pivec R, Issa K, Kapadia BH, Maheshwari A, Harwin SF (2014) Long-term implant survivorship of cementless total knee arthroplasty: a systematic review of the literature and meta-analysis. J Knee Surg 27(5):369–376PubMed
80.
Zurück zum Zitat Moon YW, Ha CW, Do KH, Kim CY, Han JH, Na SE, Lee CH, Kim JG, Park YS (2012) Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Comput Aided Surg 17(2):86–95PubMedCrossRef Moon YW, Ha CW, Do KH, Kim CY, Han JH, Na SE, Lee CH, Kim JG, Park YS (2012) Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Comput Aided Surg 17(2):86–95PubMedCrossRef
81.
Zurück zum Zitat Moskal JT, Capps SG, Mann JW, Scanelli JA (2014) Navigated versus conventional total knee arthroplasty. J Knee Surg 27(3):235–248PubMedCrossRef Moskal JT, Capps SG, Mann JW, Scanelli JA (2014) Navigated versus conventional total knee arthroplasty. J Knee Surg 27(3):235–248PubMedCrossRef
82.
Zurück zum Zitat Mueller JK, Wentorf FA, Moore RE (2014) Femoral and tibial insert downsizing increases the laxity envelope in TKA. Knee Surg Sports Traumatol Arthrosc 22(12):3003–3011PubMedPubMedCentralCrossRef Mueller JK, Wentorf FA, Moore RE (2014) Femoral and tibial insert downsizing increases the laxity envelope in TKA. Knee Surg Sports Traumatol Arthrosc 22(12):3003–3011PubMedPubMedCentralCrossRef
83.
Zurück zum Zitat Nair R, Tripathy G, Deysine GR (2014) Computer navigation systems in unicompartmental knee arthroplasty: a systematic review. Am J Orthop (Belle Mead NJ) 43(6):256–261 Nair R, Tripathy G, Deysine GR (2014) Computer navigation systems in unicompartmental knee arthroplasty: a systematic review. Am J Orthop (Belle Mead NJ) 43(6):256–261
84.
Zurück zum Zitat Nam D, McArthur BA, Cross MB, Pearle AD, Mayman DJ, Haas SB (2012) Patient-specific instrumentation in total knee arthroplasty: a review. J Knee Surg 25(3):213–219PubMedCrossRef Nam D, McArthur BA, Cross MB, Pearle AD, Mayman DJ, Haas SB (2012) Patient-specific instrumentation in total knee arthroplasty: a review. J Knee Surg 25(3):213–219PubMedCrossRef
85.
Zurück zum Zitat National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (2015) 12th Annual report National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (2015) 12th Annual report
86.
Zurück zum Zitat Nedopil AJ, Howell SM, Hull ML (2016) Does malrotation of the tibial and femoral components compromise function in kinematically aligned total knee arthroplasty? Orthop Clin North Am 47(1):41–50PubMedCrossRef Nedopil AJ, Howell SM, Hull ML (2016) Does malrotation of the tibial and femoral components compromise function in kinematically aligned total knee arthroplasty? Orthop Clin North Am 47(1):41–50PubMedCrossRef
87.
Zurück zum Zitat The New Zealand Joint Registry (2014) Fourteen year report. January 1999 to December 2013 The New Zealand Joint Registry (2014) Fourteen year report. January 1999 to December 2013
88.
Zurück zum Zitat Niinimaki TT, Murray DW, Partanen J, Pajala A, Leppilahti JI (2011) Unicompartmental knee arthroplasties implanted for osteoarthritis with partial loss of joint space have high re-operation rates. Knee 18(6):432–435PubMedCrossRef Niinimaki TT, Murray DW, Partanen J, Pajala A, Leppilahti JI (2011) Unicompartmental knee arthroplasties implanted for osteoarthritis with partial loss of joint space have high re-operation rates. Knee 18(6):432–435PubMedCrossRef
89.
Zurück zum Zitat Pabinger C, Berghold A, Boehler N, Labek G (2013) Revision rates after knee replacement. Cumulative results from worldwide clinical studies versus joint registers. Osteoarthr Cartil 21(2):263–268PubMedCrossRef Pabinger C, Berghold A, Boehler N, Labek G (2013) Revision rates after knee replacement. Cumulative results from worldwide clinical studies versus joint registers. Osteoarthr Cartil 21(2):263–268PubMedCrossRef
90.
Zurück zum Zitat Pagnano MW, Hanssen AD, Lewallen DG, Stuart MJ (1998) Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clin Orthop Relat Res 356:39–46CrossRef Pagnano MW, Hanssen AD, Lewallen DG, Stuart MJ (1998) Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clin Orthop Relat Res 356:39–46CrossRef
91.
Zurück zum Zitat Pandit H, Jenkins C, Gill HS, Barker K, Dodd CA, Murray DW (2011) Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1000 cases. J Bone Joint Surg Br 93(2):198–204PubMedCrossRef Pandit H, Jenkins C, Gill HS, Barker K, Dodd CA, Murray DW (2011) Minimally invasive Oxford phase 3 unicompartmental knee replacement: results of 1000 cases. J Bone Joint Surg Br 93(2):198–204PubMedCrossRef
92.
Zurück zum Zitat Pang HN, Yeo SJ, Chong HC, Chin PL, Ong J, Lo NN (2011) Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc 19(9):1496–1503PubMedCrossRef Pang HN, Yeo SJ, Chong HC, Chin PL, Ong J, Lo NN (2011) Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc 19(9):1496–1503PubMedCrossRef
93.
Zurück zum Zitat Park SE, Lee CT (2007) Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty. J Arthroplasty 22(7):1054–1059PubMedCrossRef Park SE, Lee CT (2007) Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty. J Arthroplasty 22(7):1054–1059PubMedCrossRef
94.
Zurück zum Zitat Pearle AD, O’Loughlin PF, Kendoff DO (2010) Robot-assisted unicompartmental knee arthroplasty. J Arthroplasty 25(2):230–237PubMedCrossRef Pearle AD, O’Loughlin PF, Kendoff DO (2010) Robot-assisted unicompartmental knee arthroplasty. J Arthroplasty 25(2):230–237PubMedCrossRef
95.
Zurück zum Zitat Plate JF, Mofidi A, Mannava S, Smith BP, Lang JE, Poehling GG, Conditt MA, Jinnah RH (2013) Achieving accurate ligament balancing using robotic-assisted unicompartmental knee arthroplasty. Adv Orthop 2013:837167PubMedPubMedCentralCrossRef Plate JF, Mofidi A, Mannava S, Smith BP, Lang JE, Poehling GG, Conditt MA, Jinnah RH (2013) Achieving accurate ligament balancing using robotic-assisted unicompartmental knee arthroplasty. Adv Orthop 2013:837167PubMedPubMedCentralCrossRef
96.
Zurück zum Zitat Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 232:168–173 Rand JA, Coventry MB (1988) Ten-year evaluation of geometric total knee arthroplasty. Clin Orthop Relat Res 232:168–173
97.
Zurück zum Zitat Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA Jr, Macaulay W (2014) Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplasty 29(5):938–944PubMedCrossRef Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA Jr, Macaulay W (2014) Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplasty 29(5):938–944PubMedCrossRef
98.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156 Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156
99.
Zurück zum Zitat Roberts TD, Clatworthy MG, Frampton CM, Young SW (2015) Does computer assisted navigation improve functional outcomes and implant survivability after total knee arthroplasty? J Arthroplasty 30(9):59–63PubMedCrossRef Roberts TD, Clatworthy MG, Frampton CM, Young SW (2015) Does computer assisted navigation improve functional outcomes and implant survivability after total knee arthroplasty? J Arthroplasty 30(9):59–63PubMedCrossRef
100.
Zurück zum Zitat Roche M, Elson L, Anderson C (2014) Dynamic soft tissue balancing in total knee arthroplasty. Orthop Clin North Am 45(2):157–165PubMedCrossRef Roche M, Elson L, Anderson C (2014) Dynamic soft tissue balancing in total knee arthroplasty. Orthop Clin North Am 45(2):157–165PubMedCrossRef
101.
Zurück zum Zitat Rosskopf J, Singh PK, Wolf P, Strauch M, Graichen H (2014) Influence of intentional femoral component flexion in navigated TKA on gap balance and sagittal anatomy. Knee Surg Sports Traumatol Arthrosc 22(3):687–693PubMedCrossRef Rosskopf J, Singh PK, Wolf P, Strauch M, Graichen H (2014) Influence of intentional femoral component flexion in navigated TKA on gap balance and sagittal anatomy. Knee Surg Sports Traumatol Arthrosc 22(3):687–693PubMedCrossRef
102.
Zurück zum Zitat Ryd L, Lindstrand A, Stenström A, Selvik G (1990) Porous coated anatomic tricompartmental tibial components: the relationship between prosthetic position and micromotion. Clin Orthop Relat Res 251:189–197 Ryd L, Lindstrand A, Stenström A, Selvik G (1990) Porous coated anatomic tricompartmental tibial components: the relationship between prosthetic position and micromotion. Clin Orthop Relat Res 251:189–197
103.
Zurück zum Zitat Schmitt J, Hauk C, Kienapfel H, Pfeiffer M, Efe T, Fuchs-Winkelmann S, Heyse TJ (2011) Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized study. BMC Musculoskelet Disord 12:16PubMedPubMedCentralCrossRef Schmitt J, Hauk C, Kienapfel H, Pfeiffer M, Efe T, Fuchs-Winkelmann S, Heyse TJ (2011) Navigation of total knee arthroplasty: rotation of components and clinical results in a prospectively randomized study. BMC Musculoskelet Disord 12:16PubMedPubMedCentralCrossRef
104.
105.
Zurück zum Zitat Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24(3):351–357PubMedCrossRef Seon JK, Song EK, Park SJ, Yoon TR, Lee KB, Jung ST (2009) Comparison of minimally invasive unicompartmental knee arthroplasty with or without a navigation system. J Arthroplasty 24(3):351–357PubMedCrossRef
106.
Zurück zum Zitat Shi J, Wei Y, Wang S, Chen F, Wu J, Huang G, Chen J, Wei L, Xia J (2014) Computer navigation and total knee arthroplasty. Orthopedics 37(1):e39–e43PubMedCrossRef Shi J, Wei Y, Wang S, Chen F, Wu J, Huang G, Chen J, Wei L, Xia J (2014) Computer navigation and total knee arthroplasty. Orthopedics 37(1):e39–e43PubMedCrossRef
107.
Zurück zum Zitat Siebert W, Mai S, Kober R, Heeckt PF (2002) Technique and first clinical results of robot-assisted total knee replacement. Knee 9(3):173–180PubMedCrossRef Siebert W, Mai S, Kober R, Heeckt PF (2002) Technique and first clinical results of robot-assisted total knee replacement. Knee 9(3):173–180PubMedCrossRef
108.
Zurück zum Zitat Sierra RJ, Kassel CA, Wetters NG, Berend KR, Della Valle CJ, Lombardi AV (2013) Revision of unicompartmental arthroplasty to total knee arthroplasty: not always a slam dunk! J Arthroplasty 28(8 Suppl):128–132PubMedCrossRef Sierra RJ, Kassel CA, Wetters NG, Berend KR, Della Valle CJ, Lombardi AV (2013) Revision of unicompartmental arthroplasty to total knee arthroplasty: not always a slam dunk! J Arthroplasty 28(8 Suppl):128–132PubMedCrossRef
109.
Zurück zum Zitat Singh VK, Varkey R, Trehan R, Kamat Y, Raghavan R, Adhikari A (2012) Functional outcome after computer-assisted total knee arthroplasty using measured resection versus gap balancing techniques: a randomised controlled study. J Orthop Surg (Hong Kong) 20(3):344–347CrossRef Singh VK, Varkey R, Trehan R, Kamat Y, Raghavan R, Adhikari A (2012) Functional outcome after computer-assisted total knee arthroplasty using measured resection versus gap balancing techniques: a randomised controlled study. J Orthop Surg (Hong Kong) 20(3):344–347CrossRef
110.
Zurück zum Zitat Sinha RK (2009) Outcomes of robotic arm-assisted unicompartmental knee arthroplasty. Am J Orthop (Belle Mead NJ) 38(2 Suppl):20–22 Sinha RK (2009) Outcomes of robotic arm-assisted unicompartmental knee arthroplasty. Am J Orthop (Belle Mead NJ) 38(2 Suppl):20–22
111.
Zurück zum Zitat Smith JR, Riches PE, Rowe PJ (2014) Accuracy of a freehand sculpting tool for unicondylar knee replacement. Int J Med Robot 10(2):162–169PubMedCrossRef Smith JR, Riches PE, Rowe PJ (2014) Accuracy of a freehand sculpting tool for unicondylar knee replacement. Int J Med Robot 10(2):162–169PubMedCrossRef
112.
Zurück zum Zitat Song EK, Mohite N, Lee SH, Na BR, Seon JK (2015) Comparison of outcome and survival after unicompartmental knee arthroplasty between navigation and conventional techniques with an average 9-year follow-up. J Arthroplasty 31(2):395–400PubMedCrossRef Song EK, Mohite N, Lee SH, Na BR, Seon JK (2015) Comparison of outcome and survival after unicompartmental knee arthroplasty between navigation and conventional techniques with an average 9-year follow-up. J Arthroplasty 31(2):395–400PubMedCrossRef
113.
Zurück zum Zitat Song EK, Seon JK, Park SJ, Jung WB, Park HW, Lee GW (2011) Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 19(7):1069–1076PubMedCrossRef Song EK, Seon JK, Park SJ, Jung WB, Park HW, Lee GW (2011) Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 19(7):1069–1076PubMedCrossRef
114.
Zurück zum Zitat Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL (2013) Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 471(1):118–126PubMedCrossRef Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL (2013) Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 471(1):118–126PubMedCrossRef
115.
Zurück zum Zitat Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89(4):477–480PubMedCrossRef Spencer JM, Chauhan SK, Sloan K, Taylor A, Beaver RJ (2007) Computer navigation versus conventional total knee replacement: no difference in functional results at two years. J Bone Joint Surg Br 89(4):477–480PubMedCrossRef
116.
Zurück zum Zitat Sriphirom P, Raungthong N, Chutchawan P, Thiranon C, Sukandhavesa N (2012) Influence of a secondary downsizing of the femoral component on the extension gap: a cadaveric study. Orthopedics 35(10 Suppl):56–59PubMedCrossRef Sriphirom P, Raungthong N, Chutchawan P, Thiranon C, Sukandhavesa N (2012) Influence of a secondary downsizing of the femoral component on the extension gap: a cadaveric study. Orthopedics 35(10 Suppl):56–59PubMedCrossRef
117.
Zurück zum Zitat Stiehl JB, Heck DA (2015) How precise is computer-navigated gap assessment in TKA? Clin Orthop Relat Res 473(1):115–118PubMedCrossRef Stiehl JB, Heck DA (2015) How precise is computer-navigated gap assessment in TKA? Clin Orthop Relat Res 473(1):115–118PubMedCrossRef
118.
Zurück zum Zitat Stulberg SD, Yaffe MA, Koo SS (2006) Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Joint Surg Am 88(Suppl 4):47–54PubMed Stulberg SD, Yaffe MA, Koo SS (2006) Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study. J Bone Joint Surg Am 88(Suppl 4):47–54PubMed
119.
Zurück zum Zitat Thiengwittayaporn S, Kanjanapiboonwong A, Junsee D (2013) Midterm outcomes of electromagnetic computer-assisted navigation in minimally invasive total knee arthroplasty. J Orthop Surg Res 8:37PubMedPubMedCentralCrossRef Thiengwittayaporn S, Kanjanapiboonwong A, Junsee D (2013) Midterm outcomes of electromagnetic computer-assisted navigation in minimally invasive total knee arthroplasty. J Orthop Surg Res 8:37PubMedPubMedCentralCrossRef
120.
Zurück zum Zitat Thienpont E, Fennema P, Price A (2013) Can technology improve alignment during knee arthroplasty. Knee 20:S21–S28PubMedCrossRef Thienpont E, Fennema P, Price A (2013) Can technology improve alignment during knee arthroplasty. Knee 20:S21–S28PubMedCrossRef
121.
Zurück zum Zitat Tolk JJ, Koot HW, Janssen RP (2012) Computer navigated versus conventional total knee arthroplasty. J Knee Surg 25(4):347–352PubMedCrossRef Tolk JJ, Koot HW, Janssen RP (2012) Computer navigated versus conventional total knee arthroplasty. J Knee Surg 25(4):347–352PubMedCrossRef
122.
Zurück zum Zitat van der List JP, Chawla H, Pearle AD (2016) Robotic-assisted knee arthroplasty: an overview. Am J Orthop (Belle Mead NJ) 45(4):202–211 van der List JP, Chawla H, Pearle AD (2016) Robotic-assisted knee arthroplasty: an overview. Am J Orthop (Belle Mead NJ) 45(4):202–211
123.
Zurück zum Zitat van der List JP, Chawla H, Villa JC, Zuiderbaan HA, Pearle AD (2015) Early functional outcome after lateral UKA is sensitive to postoperative lower limb alignment. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-015-3877-0 van der List JP, Chawla H, Villa JC, Zuiderbaan HA, Pearle AD (2015) Early functional outcome after lateral UKA is sensitive to postoperative lower limb alignment. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-015-3877-0
124.
125.
Zurück zum Zitat van der List JP, McDonald LS, Pearle AD (2015) Systematic review of medial versus lateral survivorship in unicompartmental knee arthroplasty. Knee 22(6):454–460PubMedCrossRef van der List JP, McDonald LS, Pearle AD (2015) Systematic review of medial versus lateral survivorship in unicompartmental knee arthroplasty. Knee 22(6):454–460PubMedCrossRef
126.
Zurück zum Zitat van der List JP, Zuiderbaan HA, Pearle AD (2016) Why do medial unicompartmental knee arthroplasties fail today? J Arthroplasty 31(5):1016–1021PubMedCrossRef van der List JP, Zuiderbaan HA, Pearle AD (2016) Why do medial unicompartmental knee arthroplasties fail today? J Arthroplasty 31(5):1016–1021PubMedCrossRef
127.
Zurück zum Zitat van Strien T, van der Linden-van der Zwaag E, Kaptein B, van Erkel A, Valstar E, Nelissen R (2009) Computer assisted versus conventional cemented total knee prostheses alignment accuracy and micromotion of the tibial component. Int Orthop 33 (5):1255–1261 van Strien T, van der Linden-van der Zwaag E, Kaptein B, van Erkel A, Valstar E, Nelissen R (2009) Computer assisted versus conventional cemented total knee prostheses alignment accuracy and micromotion of the tibial component. Int Orthop 33 (5):1255–1261
128.
Zurück zum Zitat Vasso M, Del Regno C, D’Amelio A, Viggiano D, Corona K, Schiavone Panni A (2015) Minor varus alignment provides better results than neutral alignment in medial UKA. Knee 22(2):117–121PubMedCrossRef Vasso M, Del Regno C, D’Amelio A, Viggiano D, Corona K, Schiavone Panni A (2015) Minor varus alignment provides better results than neutral alignment in medial UKA. Knee 22(2):117–121PubMedCrossRef
129.
Zurück zum Zitat Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43 Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43
130.
Zurück zum Zitat Weber P, Crispin A, Schmidutz F, Utzschneider S, Pietschmann MF, Jansson V, Muller PE (2013) Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 21(11):2453–2461PubMedCrossRef Weber P, Crispin A, Schmidutz F, Utzschneider S, Pietschmann MF, Jansson V, Muller PE (2013) Improved accuracy in computer-assisted unicondylar knee arthroplasty: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 21(11):2453–2461PubMedCrossRef
131.
Zurück zum Zitat Weber P, Utzschneider S, Sadoghi P, Pietschmann MF, Ficklscherer A, Jansson V, Müller PE (2012) Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation. Arch Orthop Trauma Surg 132(2):281–288PubMedCrossRef Weber P, Utzschneider S, Sadoghi P, Pietschmann MF, Ficklscherer A, Jansson V, Müller PE (2012) Navigation in minimally invasive unicompartmental knee arthroplasty has no advantage in comparison to a conventional minimally invasive implantation. Arch Orthop Trauma Surg 132(2):281–288PubMedCrossRef
132.
Zurück zum Zitat Whiteside LA (2005) Making your next unicompartmental knee arthroplasty last. J Arthroplasty 20:2–3PubMedCrossRef Whiteside LA (2005) Making your next unicompartmental knee arthroplasty last. J Arthroplasty 20:2–3PubMedCrossRef
133.
Zurück zum Zitat Wright JG, Swiontkowski MF, Heckman JD (2003) Introducing levels of evidence to the journal. J Bone Joint Surg Am 85(1):1–3PubMedCrossRef Wright JG, Swiontkowski MF, Heckman JD (2003) Introducing levels of evidence to the journal. J Bone Joint Surg Am 85(1):1–3PubMedCrossRef
134.
Zurück zum Zitat Yaffe M, Chan P, Goyal N, Luo M, Cayo M, Stulberg SD (2013) Computer-assisted versus manual TKA: no difference in clinical or functional outcomes at 5-year follow-up. Orthopedics 36(5):e627–e632PubMedCrossRef Yaffe M, Chan P, Goyal N, Luo M, Cayo M, Stulberg SD (2013) Computer-assisted versus manual TKA: no difference in clinical or functional outcomes at 5-year follow-up. Orthopedics 36(5):e627–e632PubMedCrossRef
135.
Zurück zum Zitat Yang JH, Yoon JR, Pandher DS, Oh KJ (2010) Clinical and radiologic outcomes of contemporary 3 techniques of TKA. Orthopedics 33(10 Suppl):76–81PubMedCrossRef Yang JH, Yoon JR, Pandher DS, Oh KJ (2010) Clinical and radiologic outcomes of contemporary 3 techniques of TKA. Orthopedics 33(10 Suppl):76–81PubMedCrossRef
136.
Zurück zum Zitat Yildirim G, Fernandez-Madrid I, Schwarzkopf R, Walker PS, Karia R (2014) Comparison of robot surgery modular and total knee arthroplasty kinematics. J Knee Surg 27(2):157–163PubMedCrossRef Yildirim G, Fernandez-Madrid I, Schwarzkopf R, Walker PS, Karia R (2014) Comparison of robot surgery modular and total knee arthroplasty kinematics. J Knee Surg 27(2):157–163PubMedCrossRef
137.
Zurück zum Zitat Yoshida K, Tada M, Yoshida H, Takei S, Fukuoka S, Nakamura H (2013) Oxford phase 3 unicompartmental knee arthroplasty in Japan—clinical results in greater than one thousand cases over ten years. J Arthroplasty 28(9 Suppl):168–171PubMedCrossRef Yoshida K, Tada M, Yoshida H, Takei S, Fukuoka S, Nakamura H (2013) Oxford phase 3 unicompartmental knee arthroplasty in Japan—clinical results in greater than one thousand cases over ten years. J Arthroplasty 28(9 Suppl):168–171PubMedCrossRef
138.
Zurück zum Zitat Young SW, Clarke HD, Graves SE, Liu YL, de Steiger RN (2015) Higher rate of revision in PFC sigma primary total knee arthroplasty with mismatch of femoro-tibial component sizes. J Arthroplasty 30(5):813–817PubMedCrossRef Young SW, Clarke HD, Graves SE, Liu YL, de Steiger RN (2015) Higher rate of revision in PFC sigma primary total knee arthroplasty with mismatch of femoro-tibial component sizes. J Arthroplasty 30(5):813–817PubMedCrossRef
139.
Zurück zum Zitat Zamora LA, Humphreys KJ, Watt AM, Forel D, Cameron AL (2013) Systematic review of computer-navigated total knee arthroplasty. ANZ J Surg 83(1–2):22–30PubMedCrossRef Zamora LA, Humphreys KJ, Watt AM, Forel D, Cameron AL (2013) Systematic review of computer-navigated total knee arthroplasty. ANZ J Surg 83(1–2):22–30PubMedCrossRef
140.
Zurück zum Zitat Zhang Z, Gu B, Zhu W, Zhu L, Li Q, Du Y (2014) Minimally invasive and computer-assisted total knee arthroplasty versus conventional technique: a prospective, randomized study. Eur J Orthop Surg Traumatol 24(8):1475–1479PubMedCrossRef Zhang Z, Gu B, Zhu W, Zhu L, Li Q, Du Y (2014) Minimally invasive and computer-assisted total knee arthroplasty versus conventional technique: a prospective, randomized study. Eur J Orthop Surg Traumatol 24(8):1475–1479PubMedCrossRef
141.
Zurück zum Zitat Zhang Z, Zhu W, Zhu L, Du Y (2014) Superior alignment but no difference in clinical outcome after minimally invasive computer-assisted unicompartmental knee arthroplasty (MICA-UKA). Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-014-3456-9 Zhang Z, Zhu W, Zhu L, Du Y (2014) Superior alignment but no difference in clinical outcome after minimally invasive computer-assisted unicompartmental knee arthroplasty (MICA-UKA). Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-014-3456-9
142.
Zurück zum Zitat Zhu M, Ang CL, Yeo SJ, Lo NN, Chia SL, Chong HC (2015) Minimally invasive computer-assisted total knee arthroplasty compared with conventional total knee arthroplasty: a prospective 9-year follow-up. J Arthroplasty 31(5):1000–1004PubMedCrossRef Zhu M, Ang CL, Yeo SJ, Lo NN, Chia SL, Chong HC (2015) Minimally invasive computer-assisted total knee arthroplasty compared with conventional total knee arthroplasty: a prospective 9-year follow-up. J Arthroplasty 31(5):1000–1004PubMedCrossRef
143.
Zurück zum Zitat Zihlmann MS, Stacoff A, Romero J, Quervain IK, Stussi E (2005) Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences. Clin Biomech (Bristol, Avon) 20(7):661–668CrossRef Zihlmann MS, Stacoff A, Romero J, Quervain IK, Stussi E (2005) Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences. Clin Biomech (Bristol, Avon) 20(7):661–668CrossRef
144.
Zurück zum Zitat Zuiderbaan HA, Khamaisy S, Thein R, Nawabi DH, Pearle AD (2015) Congruence and joint space width alterations of the medial compartment following lateral unicompartmental knee arthroplasty. Bone Joint J 97(1):50–55PubMedCrossRef Zuiderbaan HA, Khamaisy S, Thein R, Nawabi DH, Pearle AD (2015) Congruence and joint space width alterations of the medial compartment following lateral unicompartmental knee arthroplasty. Bone Joint J 97(1):50–55PubMedCrossRef
Metadaten
Titel
Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis
verfasst von
Jelle P. van der List
Harshvardhan Chawla
Leo Joskowicz
Andrew D. Pearle
Publikationsdatum
06.09.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4305-9

Weitere Artikel der Ausgabe 11/2016

Knee Surgery, Sports Traumatology, Arthroscopy 11/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.