Skip to main content
Erschienen in: Pediatric Radiology 5/2015

01.05.2015 | Original Article

Radiation dose in pneumatic reduction of ileo-colic intussusceptions — results from a single-institution study

verfasst von: Jennifer L. Cullmann, Johannes T. Heverhagen, Stefan Puig

Erschienen in: Pediatric Radiology | Ausgabe 5/2015

Einloggen, um Zugang zu erhalten

Abstract

Background

Air enema under fluoroscopy is a well-accepted procedure for the treatment of childhood intussusception. However, the reported radiation doses of pneumatic reduction with conventional fluoroscopy units have been high in decades past.

Objective

To compare current radiation doses at our institution to past doses reported by others for fluoroscopic-guided pneumatic reduction of ileo-colic intussusception in children.

Materials and Methods

Since 2007 radiologists and residents in our department who perform reduction of intussusceptions have received a radiation risk training. We retrospectively analyzed the data of 45 children (5 months–8 years) who underwent a total of 48 pneumatic reductions of ileo-colic intussusception between 2008 and 2012. We analyzed data for screening time and dose area product (DAP) and compared these data to those reported up to and including the year 2000.

Results

Our mean screening time measured by the DAP-meter was 53.8 s (range 1–320 s, median 33.0 s). The mean DAP was 11.4 cGy∙cm2 (range 1–145 cGy∙cm2, median 5.45 cGy∙cm2). There was one bowel perforation, in a 1-year-old boy requiring surgical revision. Only three studies in the literature presented radiation exposure results on children who received pneumatic or hydrostatic reduction of intussusception under fluoroscopy. Screening times and dose area products in those studies, which were published in the 1990s and in the year 2000, were substantially higher than those in our sample.

Conclusion

Low-frequency pulsed fluoroscopy and other dose-saving keys as well as the radiation risk training might have helped to improve the quality of the procedure in terms of radiation exposure.
Literatur
1.
Zurück zum Zitat Daneman A, Alton DJ (1996) Intussusception. Issues and controversies related to diagnosis and reduction. Radiol Clin North Am 34:743–756PubMed Daneman A, Alton DJ (1996) Intussusception. Issues and controversies related to diagnosis and reduction. Radiol Clin North Am 34:743–756PubMed
2.
Zurück zum Zitat Applegate KE (2009) Intussusception in children: evidence-based diagnosis and treatment. Pediatr Radiol 39:S140–S143CrossRefPubMed Applegate KE (2009) Intussusception in children: evidence-based diagnosis and treatment. Pediatr Radiol 39:S140–S143CrossRefPubMed
3.
Zurück zum Zitat Heenan SD, Kyriou J, Fitzgerald M et al (2000) Effective dose at pneumatic reduction of paediatric intussusception. Clin Radiol 55:811–816CrossRefPubMed Heenan SD, Kyriou J, Fitzgerald M et al (2000) Effective dose at pneumatic reduction of paediatric intussusception. Clin Radiol 55:811–816CrossRefPubMed
4.
Zurück zum Zitat Ilivitzki A, Shtark Glozman L, Arish K et al (2012) Deep sedation during pneumatic reduction of intussusception. Pediatr Radiol 42:562–565CrossRefPubMed Ilivitzki A, Shtark Glozman L, Arish K et al (2012) Deep sedation during pneumatic reduction of intussusception. Pediatr Radiol 42:562–565CrossRefPubMed
5.
Zurück zum Zitat Karlsson A, Schuwert P, Mortensson W (1994) Radiation exposure to children in diagnosing and at hydrostatic reduction of intussusception. Acta Radiol 35:296–299CrossRefPubMed Karlsson A, Schuwert P, Mortensson W (1994) Radiation exposure to children in diagnosing and at hydrostatic reduction of intussusception. Acta Radiol 35:296–299CrossRefPubMed
6.
Zurück zum Zitat Thomas RD, Fairhurst JJ, Roberts PJ (1993) Effective dose during screening monitored intussusception reduction. Clin Radiol 48:189–191CrossRefPubMed Thomas RD, Fairhurst JJ, Roberts PJ (1993) Effective dose during screening monitored intussusception reduction. Clin Radiol 48:189–191CrossRefPubMed
7.
Zurück zum Zitat Meyer JS, Dangman BC, Buonomo C et al (1993) Air and liquid contrast agents in the management of intussusception: a controlled, randomized trial. Radiology 188:507–511CrossRefPubMed Meyer JS, Dangman BC, Buonomo C et al (1993) Air and liquid contrast agents in the management of intussusception: a controlled, randomized trial. Radiology 188:507–511CrossRefPubMed
8.
Zurück zum Zitat Guo JZ, Ma XY, Zhou QH (1986) Results of air pressure enema reduction of intussusception: 6,396 cases in 13 years. J Pediatr Surg 21:1201–1203CrossRefPubMed Guo JZ, Ma XY, Zhou QH (1986) Results of air pressure enema reduction of intussusception: 6,396 cases in 13 years. J Pediatr Surg 21:1201–1203CrossRefPubMed
9.
Zurück zum Zitat Eshel G, Barr J, Heyman E et al (1997) Intussusception: a 9-year survey (1986–1995). J Pediatr Gastroenterol Nutr 24:253–256CrossRefPubMed Eshel G, Barr J, Heyman E et al (1997) Intussusception: a 9-year survey (1986–1995). J Pediatr Gastroenterol Nutr 24:253–256CrossRefPubMed
10.
Zurück zum Zitat Daneman A, Alton DJ, Ein S et al (1995) Perforation during attempted intussusception reduction in children — a comparison of perforation with barium and air. Pediatr Radiol 25:81–88CrossRefPubMed Daneman A, Alton DJ, Ein S et al (1995) Perforation during attempted intussusception reduction in children — a comparison of perforation with barium and air. Pediatr Radiol 25:81–88CrossRefPubMed
11.
Zurück zum Zitat Persliden J, Schuwert P, Mortensson W (1996) Comparison of absorbed radiation doses in barium and air enema reduction of intussusception: a phantom study. Pediatr Radiol 26:329–332CrossRefPubMed Persliden J, Schuwert P, Mortensson W (1996) Comparison of absorbed radiation doses in barium and air enema reduction of intussusception: a phantom study. Pediatr Radiol 26:329–332CrossRefPubMed
12.
Zurück zum Zitat Wang GD, Liu SJ (1988) Enema reduction of intussusception by hydrostatic pressure under ultrasound guidance: a report of 377 cases. J Pediatr Surg 23:814–818CrossRefPubMed Wang GD, Liu SJ (1988) Enema reduction of intussusception by hydrostatic pressure under ultrasound guidance: a report of 377 cases. J Pediatr Surg 23:814–818CrossRefPubMed
13.
Zurück zum Zitat Daneman A, Navarro O (2004) Intussusception. Part 2: an update on the evolution of management. Pediatr Radiol 34:97–108CrossRefPubMed Daneman A, Navarro O (2004) Intussusception. Part 2: an update on the evolution of management. Pediatr Radiol 34:97–108CrossRefPubMed
Metadaten
Titel
Radiation dose in pneumatic reduction of ileo-colic intussusceptions — results from a single-institution study
verfasst von
Jennifer L. Cullmann
Johannes T. Heverhagen
Stefan Puig
Publikationsdatum
01.05.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 5/2015
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-014-3218-3

Weitere Artikel der Ausgabe 5/2015

Pediatric Radiology 5/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.