Background

Combined prospectively electrocardiography (ECG)- and respiratory-triggered sequential cardiac computed tomography (CT) has not been evaluated in free-breathing children.

Objective

To evaluate the success rate and image quality of combined prospectively ECG- and respiratory-triggered sequential cardiac CT in free-breathing children.

Materials and methods

Image quality of combined prospectively ECG- and respiratory-triggered sequential cardiac CT in 870 children (≤5 years of age) was evaluated in terms of severe motion (maximal distance ≥2 mm) and band artifacts (maximal attenuation difference ≥100 Hounsfield units). The success rate of the scan mode was calculated. The causes of failed cases were assessed. Patient-related, radiation and image quality parameters were compared between success and failure groups.

Results

Severe motion artifacts were observed in 10.6% (92/870) of patients due to cardiac phase error in 17 (18.5%), patient motion in 12 (13.0%), and unknown causes in 63 (68.5%). Severe band artifacts were seen in 13.2% (115/870) of patients. Combined prospectively ECG- and respiratory-triggered sequential cardiac CT was successfully performed in 78.5% (683/870) of patients, while it failed in 21.5% (187/870). All the evaluated patient-related, radiation and image quality parameters were significantly different (P≤0.001) between success and failure groups except effective dose (P>0.05).

Conclusion

Additional prospective respiratory triggering can reduce motion artifacts in prospectively ECG-triggered sequential cardiac CT in free-breathing children.
Literatur
1.
Zurück zum Zitat Goo HW (2010) State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 11:4–18CrossRefPubMed Goo HW (2010) State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 11:4–18CrossRefPubMed
2.
Zurück zum Zitat Flohr TG, Leng S, Yu L et al (2009) Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality. Med Phys 36:5641–5653CrossRefPubMed Flohr TG, Leng S, Yu L et al (2009) Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality. Med Phys 36:5641–5653CrossRefPubMed
3.
Zurück zum Zitat Nie P, Wang X, Cheng Z et al (2012) Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol 22:2057–2066CrossRefPubMed Nie P, Wang X, Cheng Z et al (2012) Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol 22:2057–2066CrossRefPubMed
4.
Zurück zum Zitat Sriharan M, Lazoura O, Pavitt CW et al (2016) Evaluation of high-pitch ungated pediatric cardiovascular computed tomography for the assessment of cardiac structures in neonates. J Thorac Imaging 31:177–182CrossRefPubMed Sriharan M, Lazoura O, Pavitt CW et al (2016) Evaluation of high-pitch ungated pediatric cardiovascular computed tomography for the assessment of cardiac structures in neonates. J Thorac Imaging 31:177–182CrossRefPubMed
5.
Zurück zum Zitat Goo HW, Allmendinger T (2017) Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imaging slabs in free-breathing children: initial experience. Korean J Radiol 18:860–866CrossRefPubMedPubMedCentral Goo HW, Allmendinger T (2017) Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imaging slabs in free-breathing children: initial experience. Korean J Radiol 18:860–866CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Lu JG, Lv B, Chen XB et al (2010) What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol 75:159–165CrossRefPubMed Lu JG, Lv B, Chen XB et al (2010) What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography? Eur J Radiol 75:159–165CrossRefPubMed
7.
Zurück zum Zitat Goo HW, Yang DH (2010) Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan. Pediatr Radiol 40:1670–1680CrossRefPubMed Goo HW, Yang DH (2010) Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan. Pediatr Radiol 40:1670–1680CrossRefPubMed
8.
Zurück zum Zitat Pache G, Grohmann J, Bulla S et al (2011) Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality. Eur J Radiol 80:e440–e445CrossRefPubMed Pache G, Grohmann J, Bulla S et al (2011) Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality. Eur J Radiol 80:e440–e445CrossRefPubMed
9.
Zurück zum Zitat Blanke P, Bulla S, Baumann T et al (2010) Thoracic aorta: prospective electrocardiographically triggered CT angiography with dual-source CT--feasibility, image quality, and dose reduction. Radiology 255:207–217CrossRefPubMed Blanke P, Bulla S, Baumann T et al (2010) Thoracic aorta: prospective electrocardiographically triggered CT angiography with dual-source CT--feasibility, image quality, and dose reduction. Radiology 255:207–217CrossRefPubMed
10.
Zurück zum Zitat Wu W, Budovec J, Foley WD (2009) Prospective and retrospective ECG gating for thoracic CT angiography: a comparative study. AJR Am J Roentgenol 193:955–963CrossRefPubMed Wu W, Budovec J, Foley WD (2009) Prospective and retrospective ECG gating for thoracic CT angiography: a comparative study. AJR Am J Roentgenol 193:955–963CrossRefPubMed
11.
Zurück zum Zitat Jin KN, Park EA, Shin CI et al (2010) Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose. Int J Card Imaging 26:63–73CrossRef Jin KN, Park EA, Shin CI et al (2010) Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose. Int J Card Imaging 26:63–73CrossRef
12.
Zurück zum Zitat Goo HW (2011) Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation. Pediatr Radiol 41:839–847CrossRefPubMed Goo HW (2011) Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation. Pediatr Radiol 41:839–847CrossRefPubMed
13.
Zurück zum Zitat Goo HW, Suh DS (2006) Tube current reduction in non-electrocardiography-gated heart CT by combined tube current modulation in children. Pediatr Radiol 36:344–351CrossRefPubMed Goo HW, Suh DS (2006) Tube current reduction in non-electrocardiography-gated heart CT by combined tube current modulation in children. Pediatr Radiol 36:344–351CrossRefPubMed
14.
Zurück zum Zitat Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M (2014) Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol 203:123–130CrossRefPubMed Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M (2014) Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol 203:123–130CrossRefPubMed
15.
Zurück zum Zitat Lee KB, Goo HW (2018) Quantitative image quality and histogram-based evaluations of an iterative reconstruction algorithm at low-to-ultralow radiation dose levels: a phantom study in chest CT. Korean J Radiol 19:119–129CrossRefPubMedPubMedCentral Lee KB, Goo HW (2018) Quantitative image quality and histogram-based evaluations of an iterative reconstruction algorithm at low-to-ultralow radiation dose levels: a phantom study in chest CT. Korean J Radiol 19:119–129CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Goo HW (2012) CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol 13:1–11CrossRefPubMed Goo HW (2012) CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol 13:1–11CrossRefPubMed
17.
Zurück zum Zitat Hui P, Goo HW, Du J et al (2017) Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD). Pediatr Radiol 47:899–910CrossRefPubMed Hui P, Goo HW, Du J et al (2017) Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD). Pediatr Radiol 47:899–910CrossRefPubMed
18.
Zurück zum Zitat Bae KT (2003) Peak contrast enhancement in CT and MR angiography: when dose it occur and why? Pharmacokinetic study in a porcine model. Radiology 227:809–816CrossRefPubMed Bae KT (2003) Peak contrast enhancement in CT and MR angiography: when dose it occur and why? Pharmacokinetic study in a porcine model. Radiology 227:809–816CrossRefPubMed
19.
Zurück zum Zitat Goo HW, Park S (2015) Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction. Int J Card Imaging 31:223–232CrossRef Goo HW, Park S (2015) Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction. Int J Card Imaging 31:223–232CrossRef
20.
Zurück zum Zitat Goo HW (2017) Serial changes in anatomy and ventricular function on dual-source cardiac computed tomography after the Norwood procedure for hypoplastic left heart syndrome. Pediatr Radiol 47:1776–1786CrossRefPubMed Goo HW (2017) Serial changes in anatomy and ventricular function on dual-source cardiac computed tomography after the Norwood procedure for hypoplastic left heart syndrome. Pediatr Radiol 47:1776–1786CrossRefPubMed
21.
Zurück zum Zitat Goo HW, Seo DM, Yun TJ et al (2009) Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings. Pediatr Radiol 39:265–273CrossRefPubMed Goo HW, Seo DM, Yun TJ et al (2009) Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings. Pediatr Radiol 39:265–273CrossRefPubMed
22.
Zurück zum Zitat Goo HW (2018) Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants: comparison with transthoracic echocardiography. Pediatr Radiol 48:176–185CrossRefPubMed Goo HW (2018) Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants: comparison with transthoracic echocardiography. Pediatr Radiol 48:176–185CrossRefPubMed
23.
Zurück zum Zitat Wang Q, Qin J, He B et al (2013) Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: initial experience. Clin Radiol 68:792–798CrossRefPubMed Wang Q, Qin J, He B et al (2013) Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: initial experience. Clin Radiol 68:792–798CrossRefPubMed
24.
Zurück zum Zitat Zhang T, Wang W, Luo Z et al (2012) Initial experience on the application of 320-row CT angiography with low-dose prospective ECG-triggered in children with congenital heart disease. Int J Card Imaging 28:1787–1797CrossRef Zhang T, Wang W, Luo Z et al (2012) Initial experience on the application of 320-row CT angiography with low-dose prospective ECG-triggered in children with congenital heart disease. Int J Card Imaging 28:1787–1797CrossRef
Metadaten
Titel
Combined prospectively electrocardiography- and respiratory-triggered sequential cardiac computed tomography in free-breathing children: success rate and image quality
verfasst von
Hyun Woo Goo
Publikationsdatum
27.03.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 7/2018
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-018-4114-z

Weitere Artikel der Ausgabe 7/2018

Pediatric Radiology 7/2018 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.