Skip to main content
Erschienen in: Abdominal Radiology 1/2014

01.02.2014 | Update

Dual-energy CT of the abdomen

verfasst von: Desiree E. Morgan

Erschienen in: Abdominal Radiology | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Although conceived of in the 1970s, practical use of dual-energy CT in the clinical setting did not come to fruition until 2006, and since that time an ever expanding exploration of the technology has been underway. This article will discuss technical aspects of the two commercially available CT scanners, review the recent literature, and provide an organ-based description of abdominal dual-energy CT applications for the practicing radiologist.
Literatur
1.
Zurück zum Zitat Megibow AJ, Sahani D (2012) Best practice: implementation and use of abdominal dual-energy CT in routine patient care. AJR 199:71–77CrossRef Megibow AJ, Sahani D (2012) Best practice: implementation and use of abdominal dual-energy CT in routine patient care. AJR 199:71–77CrossRef
2.
Zurück zum Zitat Primak A, Ramirez G, Liu X, et al. (2009) Improved dual energy material discrimination for dual-source CT by means of additional spectral filtration. Med Phys 36(4):1359–1369PubMedCrossRef Primak A, Ramirez G, Liu X, et al. (2009) Improved dual energy material discrimination for dual-source CT by means of additional spectral filtration. Med Phys 36(4):1359–1369PubMedCrossRef
3.
Zurück zum Zitat Graser A, Johnson T, Chandarana H, et al. (2009) Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19:13–23PubMedCrossRef Graser A, Johnson T, Chandarana H, et al. (2009) Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19:13–23PubMedCrossRef
4.
Zurück zum Zitat Yu L, Leng S, McCollough CH (2012) Dual-energy CT-based monochromatic imaging. AJR 199:S9–S15PubMedCrossRef Yu L, Leng S, McCollough CH (2012) Dual-energy CT-based monochromatic imaging. AJR 199:S9–S15PubMedCrossRef
5.
Zurück zum Zitat Jung DC, Oh YT, Kim MD, et al. (2012) Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: a phantom study. AJR 199(6):1316–1319PubMedCrossRef Jung DC, Oh YT, Kim MD, et al. (2012) Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: a phantom study. AJR 199(6):1316–1319PubMedCrossRef
6.
Zurück zum Zitat Matsumoto K, Jinzaki M, Tanami Y, et al. (2011) Virtual monochromatic spectral imaging with fast kilovoltage switching: Improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 259(1):257–262PubMedCrossRef Matsumoto K, Jinzaki M, Tanami Y, et al. (2011) Virtual monochromatic spectral imaging with fast kilovoltage switching: Improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 259(1):257–262PubMedCrossRef
7.
Zurück zum Zitat Patel BN, Thomas JV, Lockhart ME, Berland LL, Morgan DE (2013) Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast. Clin Radiol 68(2):148–154PubMedCrossRef Patel BN, Thomas JV, Lockhart ME, Berland LL, Morgan DE (2013) Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast. Clin Radiol 68(2):148–154PubMedCrossRef
8.
Zurück zum Zitat Pessis E, Campagna R, Sverzut JM, et al. (2013) Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis. Eur J Radiol . doi:10.1016/j.ejrad.2013.02.024 Pessis E, Campagna R, Sverzut JM, et al. (2013) Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis. Eur J Radiol . doi:10.​1016/​j.​ejrad.​2013.​02.​024
9.
Zurück zum Zitat Matsuda I, Akahane M, Sato J, et al. (2012) Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms. Jpn J Radiol 30:34–39PubMedCrossRef Matsuda I, Akahane M, Sato J, et al. (2012) Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms. Jpn J Radiol 30:34–39PubMedCrossRef
10.
Zurück zum Zitat Wang L, Liu B, Wu X, et al. (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383PubMedCrossRef Wang L, Liu B, Wu X, et al. (2012) Correlation between CT attenuation value and iodine concentration in vitro: discrepancy between gemstone spectral imaging on single-source dual-energy CT and traditional polychromatic X-ray imaging. J Med Imaging Radiat Oncol 56:379–383PubMedCrossRef
11.
Zurück zum Zitat Toepker M, Moritz T, Krauss B, et al. (2012) Virtual non-contrast in second-generation, dual-energy computed tomography: reliability of attenuation values. Eur Radiol 81:e398–e405CrossRef Toepker M, Moritz T, Krauss B, et al. (2012) Virtual non-contrast in second-generation, dual-energy computed tomography: reliability of attenuation values. Eur Radiol 81:e398–e405CrossRef
12.
Zurück zum Zitat deCecco C, Buffa V, Fedeli S, et al. (2010) Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images. Eur Radiol 20:2870–2875CrossRef deCecco C, Buffa V, Fedeli S, et al. (2010) Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images. Eur Radiol 20:2870–2875CrossRef
13.
Zurück zum Zitat Sahni VA, Shinagare AB, Silverman SG (2013) Virtual unenhanced CT images acquired from dual-energy CT urography: accuracy of attenuation values and variation with contrast material phase. Clin Radiol 68(3):264–271PubMedCrossRef Sahni VA, Shinagare AB, Silverman SG (2013) Virtual unenhanced CT images acquired from dual-energy CT urography: accuracy of attenuation values and variation with contrast material phase. Clin Radiol 68(3):264–271PubMedCrossRef
14.
Zurück zum Zitat Kaufmann S, Sauter A, Spira D, et al. (2013) Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging. Acad Radiol 20(5):596–603PubMedCrossRef Kaufmann S, Sauter A, Spira D, et al. (2013) Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging. Acad Radiol 20(5):596–603PubMedCrossRef
15.
Zurück zum Zitat Zatz LM, Alvarez RE (1977) An inaccuracy in computed tomography: the energy dependence of CT values. Radiology 124:91–97PubMed Zatz LM, Alvarez RE (1977) An inaccuracy in computed tomography: the energy dependence of CT values. Radiology 124:91–97PubMed
16.
Zurück zum Zitat Graser A, Becker CR, Staehler M, et al. (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45(7):399–405 Graser A, Becker CR, Staehler M, et al. (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45(7):399–405
17.
Zurück zum Zitat Mileto A, Mazziotti S, Gaeta M, et al. (2012) Pancreatic dual-source dual-energy CT: is it time to discard unenhanced imaging? Clin Radiol 67:334–339PubMedCrossRef Mileto A, Mazziotti S, Gaeta M, et al. (2012) Pancreatic dual-source dual-energy CT: is it time to discard unenhanced imaging? Clin Radiol 67:334–339PubMedCrossRef
18.
Zurück zum Zitat Ascenti G, Mileto A, Gaeta M, et al. (2013) Single-phase dual-energy CT urography in the evaluation of haematuria. Clin Radiol 68(2):e87–e94PubMedCrossRef Ascenti G, Mileto A, Gaeta M, et al. (2013) Single-phase dual-energy CT urography in the evaluation of haematuria. Clin Radiol 68(2):e87–e94PubMedCrossRef
19.
Zurück zum Zitat Silva AC, Morse BG, Hara AK, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. RadioGraphics 31:1031–1046PubMedCrossRef Silva AC, Morse BG, Hara AK, et al. (2011) Dual-energy (spectral) CT: applications in abdominal imaging. RadioGraphics 31:1031–1046PubMedCrossRef
20.
Zurück zum Zitat Henzler T, Fink C, Schoenberg SO, et al. (2012) Dual-energy CT: radiation dose aspects. AJR 199:S16–S25PubMedCrossRef Henzler T, Fink C, Schoenberg SO, et al. (2012) Dual-energy CT: radiation dose aspects. AJR 199:S16–S25PubMedCrossRef
21.
Zurück zum Zitat Yu L, Christner JA, Leng S, et al. (2011) Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 38(12):6371–6379PubMedCrossRef Yu L, Christner JA, Leng S, et al. (2011) Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 38(12):6371–6379PubMedCrossRef
22.
Zurück zum Zitat Park J, Chandarana H, Macari M, et al. (2012) Dual-energy computed tomography applications in uroradiology. Curr Urol Rep 13:55–62PubMedCrossRef Park J, Chandarana H, Macari M, et al. (2012) Dual-energy computed tomography applications in uroradiology. Curr Urol Rep 13:55–62PubMedCrossRef
23.
Zurück zum Zitat Primak AN, Fletcher JG, Vrtiska TJ, et al. (2007) Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol 14(12):1441–1447PubMedCentralPubMedCrossRef Primak AN, Fletcher JG, Vrtiska TJ, et al. (2007) Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol 14(12):1441–1447PubMedCentralPubMedCrossRef
24.
Zurück zum Zitat Stolzmann P, Scheffel H, Rentsch K, et al. (2008) Dual-energy computed tomorgraphy for the differentiation of uric acid stones: ex vivo performance evaluation. Urol Res 36(3–4):133–138PubMedCrossRef Stolzmann P, Scheffel H, Rentsch K, et al. (2008) Dual-energy computed tomorgraphy for the differentiation of uric acid stones: ex vivo performance evaluation. Urol Res 36(3–4):133–138PubMedCrossRef
25.
Zurück zum Zitat Graser A, Johnson TR, Bader M, et al. (2008) Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Investig Radiol 43(2):112–119CrossRef Graser A, Johnson TR, Bader M, et al. (2008) Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Investig Radiol 43(2):112–119CrossRef
26.
Zurück zum Zitat Thomas C, Krauss B, Ketelsen D, et al. (2010) Differentiation of urinary calculi with dual energy CT: effect of spectral shaping by high energy tin filtration. Investig Radiol 45(7):393–398 Thomas C, Krauss B, Ketelsen D, et al. (2010) Differentiation of urinary calculi with dual energy CT: effect of spectral shaping by high energy tin filtration. Investig Radiol 45(7):393–398
27.
Zurück zum Zitat Qu M, Ramirez-Giraldo JC, Leng S, et al. (2011) Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study. AJR 196(6):1279–1287PubMedCentralPubMedCrossRef Qu M, Ramirez-Giraldo JC, Leng S, et al. (2011) Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study. AJR 196(6):1279–1287PubMedCentralPubMedCrossRef
28.
Zurück zum Zitat Zilberman J, Ferrandino M, Preminger G, et al. (2010) In vivo determination of urinary stone composition using dual energy computerized tomography with advanced post-acquisition processing. J Urol 184:2354–2359PubMedCrossRef Zilberman J, Ferrandino M, Preminger G, et al. (2010) In vivo determination of urinary stone composition using dual energy computerized tomography with advanced post-acquisition processing. J Urol 184:2354–2359PubMedCrossRef
29.
Zurück zum Zitat Fung G, Kawamoto S, Matlaga B, et al. (2012) Differentiation of kidney stones using dual-energy CT with and without a tin filter. AJR 198:1380–1386PubMedCrossRef Fung G, Kawamoto S, Matlaga B, et al. (2012) Differentiation of kidney stones using dual-energy CT with and without a tin filter. AJR 198:1380–1386PubMedCrossRef
30.
Zurück zum Zitat Wang J, Qu M, Duan X, et al. (2012) Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study. Eur Radiol 22(12):2589–2596PubMedCrossRef Wang J, Qu M, Duan X, et al. (2012) Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study. Eur Radiol 22(12):2589–2596PubMedCrossRef
31.
Zurück zum Zitat Karlo CA, Gnannt R, Winklehner A, et al. (2013) Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones. Abdom Imaging 38(5):1136–1143 Karlo CA, Gnannt R, Winklehner A, et al. (2013) Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones. Abdom Imaging 38(5):1136–1143
32.
Zurück zum Zitat Hartman R, Kawashima A, Takahashi N, et al. (2012) Applications of dual-energy CT in urologic imaging: an update. Radiol Clin N Am 50:191–205PubMedCrossRef Hartman R, Kawashima A, Takahashi N, et al. (2012) Applications of dual-energy CT in urologic imaging: an update. Radiol Clin N Am 50:191–205PubMedCrossRef
33.
Zurück zum Zitat Manglaviti G, Tresoldi S, Guerrer C, et al. (2011) In vivo evaluation of the chemical composition of urinary stones using dual-energy CT. AJR 197(1):W76–W83PubMedCrossRef Manglaviti G, Tresoldi S, Guerrer C, et al. (2011) In vivo evaluation of the chemical composition of urinary stones using dual-energy CT. AJR 197(1):W76–W83PubMedCrossRef
34.
Zurück zum Zitat Kulkarni NM, Eisner BH, Pinho DF, et al. (2013) Determination of renal stone composition in phantom and patients using single-source dual-energy computed tomography. J Comput Assist Tomogr 37(1):37–45PubMedCrossRef Kulkarni NM, Eisner BH, Pinho DF, et al. (2013) Determination of renal stone composition in phantom and patients using single-source dual-energy computed tomography. J Comput Assist Tomogr 37(1):37–45PubMedCrossRef
35.
Zurück zum Zitat Chandarana H, Megibow A, Cohen B, et al. (2011) Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR 196:W693–W700PubMedCrossRef Chandarana H, Megibow A, Cohen B, et al. (2011) Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR 196:W693–W700PubMedCrossRef
36.
Zurück zum Zitat Kaza RK, Caoili EM, Cohan RH, et al. (2011) Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR 197:1375–1381PubMedCrossRef Kaza RK, Caoili EM, Cohan RH, et al. (2011) Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual-energy CT. AJR 197:1375–1381PubMedCrossRef
37.
Zurück zum Zitat Ascenti G, Mileto A, Krauss B, et al. (2013) Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements. Eur Radiol 23(8):2288–2295 Ascenti G, Mileto A, Krauss B, et al. (2013) Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements. Eur Radiol 23(8):2288–2295
39.
Zurück zum Zitat Gnannt R, Fischer M, Goetti R, et al. (2012) Dual-energy CT for characterization of the incidental adrenal mass: preliminary observations. AJR 198:138–144PubMedCrossRef Gnannt R, Fischer M, Goetti R, et al. (2012) Dual-energy CT for characterization of the incidental adrenal mass: preliminary observations. AJR 198:138–144PubMedCrossRef
40.
Zurück zum Zitat Ho LM, Marin D, Neville AM, et al. (2012) Characterization of adrenal nodules with dual-energy CT: can virtual unenhanced attenuation values replace true unenhanced attenuation values? AJR 198:840–845PubMedCrossRef Ho LM, Marin D, Neville AM, et al. (2012) Characterization of adrenal nodules with dual-energy CT: can virtual unenhanced attenuation values replace true unenhanced attenuation values? AJR 198:840–845PubMedCrossRef
41.
Zurück zum Zitat Kim YK, Park BK, Kim CK, Park SY (2013) Adenoma characterization: adrenal protocol with dual-energy CT. Radiology 267:155–163PubMedCrossRef Kim YK, Park BK, Kim CK, Park SY (2013) Adenoma characterization: adrenal protocol with dual-energy CT. Radiology 267:155–163PubMedCrossRef
42.
Zurück zum Zitat Kim JE, Lee JM, Baek JH, et al. (2012) Initial assessment of dual-energy CT in patients with gallstones or bile duct stones: can virtual nonenhanced images replace true nonenhanced images? AJR 198:817–824PubMedCrossRef Kim JE, Lee JM, Baek JH, et al. (2012) Initial assessment of dual-energy CT in patients with gallstones or bile duct stones: can virtual nonenhanced images replace true nonenhanced images? AJR 198:817–824PubMedCrossRef
43.
Zurück zum Zitat Fischer MA, Reiner CS, Raptis D, et al. (2011) Quantification of liver iron content with CT—added value of dual-energy. Eur Radiol 21:1727–1732PubMedCrossRef Fischer MA, Reiner CS, Raptis D, et al. (2011) Quantification of liver iron content with CT—added value of dual-energy. Eur Radiol 21:1727–1732PubMedCrossRef
44.
Zurück zum Zitat Fischer MA, Gnannt R, Raptis D, et al. (2011) Quantification of liver fat in the presence of iron and iodine. Investig Radiol 46(6):351–358CrossRef Fischer MA, Gnannt R, Raptis D, et al. (2011) Quantification of liver fat in the presence of iron and iodine. Investig Radiol 46(6):351–358CrossRef
45.
Zurück zum Zitat Joe E, Kim S, Lee KB, et al. (2012) Feasibility and accuracy of dual-source dual-energy CT for noninvasive determination of hepatic iron accumulation. Radiology 262(1):126–135PubMedCrossRef Joe E, Kim S, Lee KB, et al. (2012) Feasibility and accuracy of dual-source dual-energy CT for noninvasive determination of hepatic iron accumulation. Radiology 262(1):126–135PubMedCrossRef
46.
Zurück zum Zitat Artz NS, Hines C, Brunner ST, et al. (2012) Quantification of hepatic steatosis with dual-energy computed tomography. Investig Radiol 47(10):603–610CrossRef Artz NS, Hines C, Brunner ST, et al. (2012) Quantification of hepatic steatosis with dual-energy computed tomography. Investig Radiol 47(10):603–610CrossRef
47.
Zurück zum Zitat Zheng X, Ren Y, Phillips WT, et al. (2013) Assessment of hepatic fatty infiltration using spectral computed tomography imaging: a pilot study. J Comput Assist Tomogr 37(2):134–141PubMedCrossRef Zheng X, Ren Y, Phillips WT, et al. (2013) Assessment of hepatic fatty infiltration using spectral computed tomography imaging: a pilot study. J Comput Assist Tomogr 37(2):134–141PubMedCrossRef
48.
Zurück zum Zitat Qian LJ, Zhu J, Zhuang ZZG, et al. (2012) Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study. Eur Radiol 22:2178–2185PubMedCrossRef Qian LJ, Zhu J, Zhuang ZZG, et al. (2012) Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study. Eur Radiol 22:2178–2185PubMedCrossRef
49.
Zurück zum Zitat Altenbernd J, Heusner TA, Ringelstein A, et al. (2011) Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity. Eur Radiol 21:738–743PubMedCrossRef Altenbernd J, Heusner TA, Ringelstein A, et al. (2011) Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity. Eur Radiol 21:738–743PubMedCrossRef
50.
Zurück zum Zitat Wang Q, Shi G, Liu X, et al. (2013) Optimal contrast of computed tomography portal venography using dual-energy computed tomography. J Comput Assist Tomogr 37(2):142–148PubMedCrossRef Wang Q, Shi G, Liu X, et al. (2013) Optimal contrast of computed tomography portal venography using dual-energy computed tomography. J Comput Assist Tomogr 37(2):142–148PubMedCrossRef
51.
Zurück zum Zitat Lee JA, Jeong WK, Kim Y, et al. (2013) Dual-energy CT to detect recurrent HCC after TACE: initial experience of color-coded iodine CT imaging. Eur J Radiol 82(4):569–576PubMedCrossRef Lee JA, Jeong WK, Kim Y, et al. (2013) Dual-energy CT to detect recurrent HCC after TACE: initial experience of color-coded iodine CT imaging. Eur J Radiol 82(4):569–576PubMedCrossRef
52.
Zurück zum Zitat Lee SH, Lee JM, Kim KW, et al. (2011) Dual-energy computed tomography to assess tumor response to hepatic radiofrequency ablation. Investig Radiol 46(2):77–84CrossRef Lee SH, Lee JM, Kim KW, et al. (2011) Dual-energy computed tomography to assess tumor response to hepatic radiofrequency ablation. Investig Radiol 46(2):77–84CrossRef
53.
Zurück zum Zitat Macari M, Spieler B, Kim D, et al. (2010) Dual-source dual-energy MDCT of pancreatic adenocarcinoma: initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp. AJR 194:W27–W32PubMedCrossRef Macari M, Spieler B, Kim D, et al. (2010) Dual-source dual-energy MDCT of pancreatic adenocarcinoma: initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp. AJR 194:W27–W32PubMedCrossRef
54.
Zurück zum Zitat Chu AJ, Lee JM, Lee YJ, et al. (2012) Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours. British J Radiol 85:e891–e898CrossRef Chu AJ, Lee JM, Lee YJ, et al. (2012) Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours. British J Radiol 85:e891–e898CrossRef
55.
Zurück zum Zitat Kaza R, Platt J, Al-Hawary M, et al. (2012) CT enterography at 80 kVp with adaptive statistical iterative reconstruction versus at 120 kVp with standard reconstruction: image quality, diagnostic adequacy, and dose reduction. AJR 198:1084–1092PubMedCrossRef Kaza R, Platt J, Al-Hawary M, et al. (2012) CT enterography at 80 kVp with adaptive statistical iterative reconstruction versus at 120 kVp with standard reconstruction: image quality, diagnostic adequacy, and dose reduction. AJR 198:1084–1092PubMedCrossRef
56.
Zurück zum Zitat Boellaard T, Henneman O, Streekstra G, et al. (2013) The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping. Clin Radiol 68(8):799–806 Boellaard T, Henneman O, Streekstra G, et al. (2013) The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping. Clin Radiol 68(8):799–806
57.
Zurück zum Zitat Schramm N, Schlemmer M, Englhart E, et al. (2011) Dual energy CT for monitoring targeted therapies in patients with advanced gastrointestinal stromal tumor: initial results. Curr Pharm Biotechnol 12:547–557PubMedCrossRef Schramm N, Schlemmer M, Englhart E, et al. (2011) Dual energy CT for monitoring targeted therapies in patients with advanced gastrointestinal stromal tumor: initial results. Curr Pharm Biotechnol 12:547–557PubMedCrossRef
58.
Zurück zum Zitat Apfaltrer P, Meyer M, Meier C, et al. (2012) Contrast-enhanced dual-energy CT of gastrointestinal stromal tumors. Investig Radiol 47(1):65–70CrossRef Apfaltrer P, Meyer M, Meier C, et al. (2012) Contrast-enhanced dual-energy CT of gastrointestinal stromal tumors. Investig Radiol 47(1):65–70CrossRef
59.
Zurück zum Zitat Meyer M, Hohenberger P, Apfaltrer P, et al. (2013) CT-based response assessment of advanced gastrointestinal stromal tumor: dual energy CT provides a more predictive imaging biomarker of clinical benefit than RECIST or Choi criteria. Eur J Radiol 82(6):923–928PubMedCrossRef Meyer M, Hohenberger P, Apfaltrer P, et al. (2013) CT-based response assessment of advanced gastrointestinal stromal tumor: dual energy CT provides a more predictive imaging biomarker of clinical benefit than RECIST or Choi criteria. Eur J Radiol 82(6):923–928PubMedCrossRef
60.
Zurück zum Zitat Mongan J, Rathnayake S. Fu Y, et al. (2013) Extravasated contrast material in penetrating abdominopelvic trauma: dual-contrast dual-energy CT for improved diagnosis-preliminary results in an animal model. Radiology 268(3):738–742 Mongan J, Rathnayake S. Fu Y, et al. (2013) Extravasated contrast material in penetrating abdominopelvic trauma: dual-contrast dual-energy CT for improved diagnosis-preliminary results in an animal model. Radiology 268(3):738–742
Metadaten
Titel
Dual-energy CT of the abdomen
verfasst von
Desiree E. Morgan
Publikationsdatum
01.02.2014
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 1/2014
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-013-0033-5

Weitere Artikel der Ausgabe 1/2014

Abdominal Radiology 1/2014 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.