Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 1/2013

01.02.2013 | Clinical Investigation

Protective Embolization of the Gastroduodenal Artery with a One-HydroCoil Technique in Radioembolization Procedures

verfasst von: R. López-Benítez, P. Hallscheidt, C. Kratochwil, C. Ernst, L. Kara, O. Rusch, P. Vock, J. Kettenbach

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 1/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection.

Methods

Twenty-three subjects with unresectable liver tumors, who were scheduled for protective occlusion of the GDA before radioembolization therapy, were included. The primary end point was to achieve a proximal occlusion of the GDA with only one detachable HydroCoil. Evaluated parameters were duration of deployment, and early (during the intervention) and late (7–21 days) occlusion rates of GDA. Secondary end points included complete duration of the intervention, amount of contrast medium used, fluoroscopy rates, and adverse effects.

Results

In all cases, the GDA was successfully occluded with only one HydroCoil. The selected diameter/length range was 4/10 mm in 2 patients, 4/15 mm in 6 patients, and 4/20 mm in 15 patients. HydroCoils were implanted, on average, 3.75 mm from the origin of the GDA (range 1.5–6.8 mm), with an average deployment time of 2:47 (median 2:42, range 2:30–3:07) min. In 21 (91%) of 23 patients, a complete occlusion of the GDA was achieved during the first 30 min after the coil implantation; however, in all patients, a late occlusion of the GDA was present after 6 to 29 days. No clinical or technical complications were reported.

Conclusion

We demonstrated that occlusion of the GDA with a single HydroCoil is a safe procedure and successfully prevents extrahepatic embolization before radioembolization.
Literatur
1.
Zurück zum Zitat Bilbao JI, Garrastachu P, Herraiz MJ et al (2010) Safety and efficacy assessment of flow redistribution by occlusion of intrahepatic vessels prior to radioembolization in the treatment of liver tumors. Cardiovasc Intervent Radiol 33:523–531PubMedCrossRef Bilbao JI, Garrastachu P, Herraiz MJ et al (2010) Safety and efficacy assessment of flow redistribution by occlusion of intrahepatic vessels prior to radioembolization in the treatment of liver tumors. Cardiovasc Intervent Radiol 33:523–531PubMedCrossRef
2.
Zurück zum Zitat Daghir AA, Gungor H, Haydar AA et al (2011) Embolisation of the gastroduodenal artery is not necessary in the presence of reversed flow before yttrium-90 radioembolisation. Cardiovasc Intervent Radiol. doi:10.1007/s00270-011-0208-9 PubMed Daghir AA, Gungor H, Haydar AA et al (2011) Embolisation of the gastroduodenal artery is not necessary in the presence of reversed flow before yttrium-90 radioembolisation. Cardiovasc Intervent Radiol. doi:10.​1007/​s00270-011-0208-9 PubMed
3.
Zurück zum Zitat Dudeck O, Bulla K, Wieners G et al (2011) Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing standard pushable coils with fibered interlock detachable coils. Cardiovasc Intervent Radiol 34:74–80PubMedCrossRef Dudeck O, Bulla K, Wieners G et al (2011) Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing standard pushable coils with fibered interlock detachable coils. Cardiovasc Intervent Radiol 34:74–80PubMedCrossRef
4.
Zurück zum Zitat Killer M, Arthur AS, Barr JD et al (2010) Histomorphology of thrombus organization, neointima formation, and foreign body response in retrieved human aneurysms treated with hydrocoil devices. J Biomed Mater Res B Appl Biomater 94:486–492PubMed Killer M, Arthur AS, Barr JD et al (2010) Histomorphology of thrombus organization, neointima formation, and foreign body response in retrieved human aneurysms treated with hydrocoil devices. J Biomed Mater Res B Appl Biomater 94:486–492PubMed
5.
Zurück zum Zitat Guimaraes M, Uflacker R, Garretson JS et al (2011) Angiographic and histologic comparison of injectable, expansile hydrogel embolic and pushable AZUR embolic devices in porcine arteries. J Vasc Interv Radiol 22:1619–1624PubMedCrossRef Guimaraes M, Uflacker R, Garretson JS et al (2011) Angiographic and histologic comparison of injectable, expansile hydrogel embolic and pushable AZUR embolic devices in porcine arteries. J Vasc Interv Radiol 22:1619–1624PubMedCrossRef
6.
Zurück zum Zitat Constant MJ, Keeley EM, Cruise GM (2009) Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization. J Biomed Mater Res B Appl Biomater 89:306–313PubMed Constant MJ, Keeley EM, Cruise GM (2009) Preparation, characterization, and evaluation of radiopaque hydrogel filaments for endovascular embolization. J Biomed Mater Res B Appl Biomater 89:306–313PubMed
7.
Zurück zum Zitat Kennedy A, Coldwell D, Sangro B et al (2012) Integrating radioembolization (90Y microspheres) into current treatment options for liver tumors: introduction to the international working group report. Am J Clin Oncol 35:81–90PubMedCrossRef Kennedy A, Coldwell D, Sangro B et al (2012) Integrating radioembolization (90Y microspheres) into current treatment options for liver tumors: introduction to the international working group report. Am J Clin Oncol 35:81–90PubMedCrossRef
8.
Zurück zum Zitat Silveira LA, Silveira FB, Fazan VP (2009) Arterial diameter of the celiac trunk and its branches. Anatomical study. Acta Cir Bras 24:43–47PubMedCrossRef Silveira LA, Silveira FB, Fazan VP (2009) Arterial diameter of the celiac trunk and its branches. Anatomical study. Acta Cir Bras 24:43–47PubMedCrossRef
9.
Zurück zum Zitat Ogawa F, Mino-Kenudson M, Shimizu M et al (2008) Gastroduodenitis associated with yttrium 90–microsphere selective internal radiation: an iatrogenic complication in need of recognition. Arch Pathol Lab Med 132:1734–1738PubMed Ogawa F, Mino-Kenudson M, Shimizu M et al (2008) Gastroduodenitis associated with yttrium 90–microsphere selective internal radiation: an iatrogenic complication in need of recognition. Arch Pathol Lab Med 132:1734–1738PubMed
10.
Zurück zum Zitat Sjoquist KM, Goldstein D, Bester L (2010) A serious complication of selected internal radiation therapy: case report and literature review. Oncologist 15:830–835PubMedCrossRef Sjoquist KM, Goldstein D, Bester L (2010) A serious complication of selected internal radiation therapy: case report and literature review. Oncologist 15:830–835PubMedCrossRef
11.
Zurück zum Zitat Pech M, Kraetsch A, Wieners G et al (2009) Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing platinum-fibered microcoils with the Amplatzer Vascular Plug II. Cardiovasc Intervent Radiol 32:455–461PubMedCrossRef Pech M, Kraetsch A, Wieners G et al (2009) Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing platinum-fibered microcoils with the Amplatzer Vascular Plug II. Cardiovasc Intervent Radiol 32:455–461PubMedCrossRef
12.
Zurück zum Zitat Deshaies EM, Adamo MA, Boulos AS (2007) A prospective single-center analysis of the safety and efficacy of the hydrocoil embolization system for the treatment of intracranial aneurysms. J Neurosurg 106:226–233PubMedCrossRef Deshaies EM, Adamo MA, Boulos AS (2007) A prospective single-center analysis of the safety and efficacy of the hydrocoil embolization system for the treatment of intracranial aneurysms. J Neurosurg 106:226–233PubMedCrossRef
13.
Zurück zum Zitat Gaba RC, Ansari SA, Roy SS et al (2006) Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy. Stroke 37:1443–1450PubMedCrossRef Gaba RC, Ansari SA, Roy SS et al (2006) Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy. Stroke 37:1443–1450PubMedCrossRef
14.
Zurück zum Zitat Gunnarsson T, Tong FC, Klurfan P et al (2009) Angiographic and clinical outcomes in 200 consecutive patients with cerebral aneurysm treated with hydrogel-coated coils. AJNR Am J Neuroradiol 30:1657–1664PubMedCrossRef Gunnarsson T, Tong FC, Klurfan P et al (2009) Angiographic and clinical outcomes in 200 consecutive patients with cerebral aneurysm treated with hydrogel-coated coils. AJNR Am J Neuroradiol 30:1657–1664PubMedCrossRef
Metadaten
Titel
Protective Embolization of the Gastroduodenal Artery with a One-HydroCoil Technique in Radioembolization Procedures
verfasst von
R. López-Benítez
P. Hallscheidt
C. Kratochwil
C. Ernst
L. Kara
O. Rusch
P. Vock
J. Kettenbach
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 1/2013
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-012-0361-9

Weitere Artikel der Ausgabe 1/2013

CardioVascular and Interventional Radiology 1/2013 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.