Abstract

Purpose

The aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair.

Materials and Methods

Occupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding was used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented.

Results

Average procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049).

Conclusion

Average FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.
Literatur
1.
Zurück zum Zitat Buck DB, van Herwaarden JA, Schermerhorn ML, Moll FL (2014) Endovascular treatment of abdominal aortic aneurysms. Nat Rev Cardiol 11(2):112–123PubMedCentralPubMedCrossRef Buck DB, van Herwaarden JA, Schermerhorn ML, Moll FL (2014) Endovascular treatment of abdominal aortic aneurysms. Nat Rev Cardiol 11(2):112–123PubMedCentralPubMedCrossRef
2.
Zurück zum Zitat Matsumura JS, Melissano G, Cambria RP, Dake MD, Mehta S, Svensson LG, Moore RD, Zenith TX2 Clinical Trial Investigators (2014) Five-year results of thoracic endovascular aortic repair with the Zenith TX2. J Vasc Surg 60(1):1–10PubMedCrossRef Matsumura JS, Melissano G, Cambria RP, Dake MD, Mehta S, Svensson LG, Moore RD, Zenith TX2 Clinical Trial Investigators (2014) Five-year results of thoracic endovascular aortic repair with the Zenith TX2. J Vasc Surg 60(1):1–10PubMedCrossRef
3.
Zurück zum Zitat Greenberg RK, Sternbergh WC III, Makaroun M, Ohki T, Chuter T, Bharadwaj P, Saunders A, Fenestrated Investigators (2009) Intermediate results of a United States multicenter trial of fenestrated endograft repair for juxtarenal abdominal aortic aneurysms. J Vasc Surg 50(4):730–737 Greenberg RK, Sternbergh WC III, Makaroun M, Ohki T, Chuter T, Bharadwaj P, Saunders A, Fenestrated Investigators (2009) Intermediate results of a United States multicenter trial of fenestrated endograft repair for juxtarenal abdominal aortic aneurysms. J Vasc Surg 50(4):730–737
4.
Zurück zum Zitat Valentin J (2000) Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30(2):7–67PubMedCrossRef Valentin J (2000) Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 30(2):7–67PubMedCrossRef
5.
Zurück zum Zitat Kirkwood ML, Arbique GM, Guild JB, Timaran C, Chung J, Anderson JA, Valentine RJ (2013) Surgeon education decreases radiation dose in complex endovascular procedures and improves patient safety. J Vasc Surg 58(3):715–721PubMedCrossRef Kirkwood ML, Arbique GM, Guild JB, Timaran C, Chung J, Anderson JA, Valentine RJ (2013) Surgeon education decreases radiation dose in complex endovascular procedures and improves patient safety. J Vasc Surg 58(3):715–721PubMedCrossRef
6.
Zurück zum Zitat Eleveld H, Tanzi CP (2004) Ministry of Social Affairs and Employment Netherlands. Standaardisatie van persoonsdosimetrie bij beroepsmatige blootstelling aan ioniserende straling, report no. 329 Eleveld H, Tanzi CP (2004) Ministry of Social Affairs and Employment Netherlands. Standaardisatie van persoonsdosimetrie bij beroepsmatige blootstelling aan ioniserende straling, report no. 329
7.
Zurück zum Zitat Van Dijk JWE, Ebben L, Franken Y (2008) Netherlands Commission on Radiation Dosimetry Subcommittee Lead Aprons. Code of practice for personal dosimetry of professionals wearing protective clothing during radiological procedures. Report 19 of the Netherlands Commission on Radiation Dosimetry Van Dijk JWE, Ebben L, Franken Y (2008) Netherlands Commission on Radiation Dosimetry Subcommittee Lead Aprons. Code of practice for personal dosimetry of professionals wearing protective clothing during radiological procedures. Report 19 of the Netherlands Commission on Radiation Dosimetry
8.
Zurück zum Zitat Bartal G, Vano E, Paulo G, Miller DL (2014) Management of patient and staff radiation dose in interventional radiology: current concepts. Cardiovasc Intervent Radiol 37(2):289–298PubMedCrossRef Bartal G, Vano E, Paulo G, Miller DL (2014) Management of patient and staff radiation dose in interventional radiology: current concepts. Cardiovasc Intervent Radiol 37(2):289–298PubMedCrossRef
9.
Zurück zum Zitat Sutton DG, Williams JR (2012) Radiation shielding for diagnostic radiology. British Institute of Radiology, London, pp 74–77 Sutton DG, Williams JR (2012) Radiation shielding for diagnostic radiology. British Institute of Radiology, London, pp 74–77
10.
Zurück zum Zitat Haqqani OP, Agarwal PK, Halin NM, Iafrati MD (2013) Defining the radiation “scatter cloud” in the interventional suite. J Vasc Surg 58(5):1339–1345PubMedCrossRef Haqqani OP, Agarwal PK, Halin NM, Iafrati MD (2013) Defining the radiation “scatter cloud” in the interventional suite. J Vasc Surg 58(5):1339–1345PubMedCrossRef
11.
Zurück zum Zitat Mohapatra A, Greenberg RK, Mastracci TM, Eagleton MJ, Thornsberry B (2013) Radiation exposure to operating room personnel and patients during endovascular procedures. J Vasc Surg 58(3):702–709PubMedCrossRef Mohapatra A, Greenberg RK, Mastracci TM, Eagleton MJ, Thornsberry B (2013) Radiation exposure to operating room personnel and patients during endovascular procedures. J Vasc Surg 58(3):702–709PubMedCrossRef
12.
Zurück zum Zitat Kloeze C, Klompenhouwer EG, Brands PJ, van Sambeek MR, Cuypers PW, Teijink JA (2014) Use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures. Eur J Vasc Endovasc Surg 47(3):268–272PubMedCrossRef Kloeze C, Klompenhouwer EG, Brands PJ, van Sambeek MR, Cuypers PW, Teijink JA (2014) Use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures. Eur J Vasc Endovasc Surg 47(3):268–272PubMedCrossRef
13.
Zurück zum Zitat Patel AP, Gallacher D, Dourado R, Lyons O, Smith A, Zayed H, Waltham M, Sabharwal T, Bell R, Carrell T, Taylor P, Modarai B (2013) Occupational radiation exposure during endovascular aortic procedures. Eur J Vasc Endovasc Surg 46(4):424–430PubMedCrossRef Patel AP, Gallacher D, Dourado R, Lyons O, Smith A, Zayed H, Waltham M, Sabharwal T, Bell R, Carrell T, Taylor P, Modarai B (2013) Occupational radiation exposure during endovascular aortic procedures. Eur J Vasc Endovasc Surg 46(4):424–430PubMedCrossRef
14.
Zurück zum Zitat Vano E, Kleiman NJ, Duran A, Romano-Miller M, Rehani MM (2013) Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments. J Vasc Interv Radiol 24(2):197–204PubMedCrossRef Vano E, Kleiman NJ, Duran A, Romano-Miller M, Rehani MM (2013) Radiation-associated lens opacities in catheterization personnel: results of a survey and direct assessments. J Vasc Interv Radiol 24(2):197–204PubMedCrossRef
15.
Zurück zum Zitat Broughton J, Cantone MC, Ginjaume M, Shah B (2013) Report of Task Group on the implications of the implementation of the ICRP recommendations for a revised dose limit to the lens of the eye. J Radiol Prot 33(4):855–868PubMedCrossRef Broughton J, Cantone MC, Ginjaume M, Shah B (2013) Report of Task Group on the implications of the implementation of the ICRP recommendations for a revised dose limit to the lens of the eye. J Radiol Prot 33(4):855–868PubMedCrossRef
16.
Zurück zum Zitat van Rooijen BD, de Haan MW, Das M, Arnoldussen CW, de Graaf R, van Zwam WH, Backes WH, Jeukens CR (2013) Efficacy of radiation safety glasses in interventional radiology. Cardiovasc Intervent Radiol 37(5):1149–1155 van Rooijen BD, de Haan MW, Das M, Arnoldussen CW, de Graaf R, van Zwam WH, Backes WH, Jeukens CR (2013) Efficacy of radiation safety glasses in interventional radiology. Cardiovasc Intervent Radiol 37(5):1149–1155
17.
Zurück zum Zitat ICRP (2007) The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 37:1–332 ICRP (2007) The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 37:1–332
18.
Zurück zum Zitat ICRP (1997) Publication 74: conversion coefficients for use in radiological protection against external radiation. Annals of the ICRP, vol 26/3. Elsevier, Oxford ICRP (1997) Publication 74: conversion coefficients for use in radiological protection against external radiation. Annals of the ICRP, vol 26/3. Elsevier, Oxford
19.
Zurück zum Zitat Lie ØØ, Paulsen GU, Wøhni T (2008) Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist. Radiat Prot Dosim 132(3):313–318CrossRef Lie ØØ, Paulsen GU, Wøhni T (2008) Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist. Radiat Prot Dosim 132(3):313–318CrossRef
20.
Zurück zum Zitat Sanchez RM, Vano E, Fernandez JM, Ginjaume M, Duch MA (2014) Measurements of eye lens doses in interventional cardiology using osl and electronic dosemeters. Radiat Prot Dosim. doi:10.1093/rpd/nct368 Sanchez RM, Vano E, Fernandez JM, Ginjaume M, Duch MA (2014) Measurements of eye lens doses in interventional cardiology using osl and electronic dosemeters. Radiat Prot Dosim. doi:10.​1093/​rpd/​nct368
21.
Zurück zum Zitat Maurel B, Hertault A, Sobocinski J, Le Roux M, Gonzalez TM, Azzaoui R, Saeed Kilani M, Midulla M, Haulon S (2014) Techniques to reduce radiation and contrast volume during EVAR. J Cardiovasc Surg (Torino) 55(2 Suppl 1):123–131 Maurel B, Hertault A, Sobocinski J, Le Roux M, Gonzalez TM, Azzaoui R, Saeed Kilani M, Midulla M, Haulon S (2014) Techniques to reduce radiation and contrast volume during EVAR. J Cardiovasc Surg (Torino) 55(2 Suppl 1):123–131
22.
Zurück zum Zitat Scheurig-Muenkler C, Powerski MJ, Mueller JC, Kroencke TJ (2014) Radiation exposure during uterine artery embolization: effective measures to minimize dose to the patient. Cardiovasc Intervent Radiol. doi:10.1007/s00270-014-0962-6 Scheurig-Muenkler C, Powerski MJ, Mueller JC, Kroencke TJ (2014) Radiation exposure during uterine artery embolization: effective measures to minimize dose to the patient. Cardiovasc Intervent Radiol. doi:10.​1007/​s00270-014-0962-6
23.
Zurück zum Zitat Sailer AM, de Haan MW, Peppelenbosch AG, Jacobs MJ, Wildberger JE, Schurink GW (2014) CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg 47(4):349–356PubMedCrossRef Sailer AM, de Haan MW, Peppelenbosch AG, Jacobs MJ, Wildberger JE, Schurink GW (2014) CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair. Eur J Vasc Endovasc Surg 47(4):349–356PubMedCrossRef
24.
Zurück zum Zitat Hertault A, Maurel B, Sobocinski J, Martin Gonzalez T, Le Roux M, Azzaoui R, Midulla M, Haulon S (2014) Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair. Eur J Vasc Endovasc Surg 48(4):382–390 Hertault A, Maurel B, Sobocinski J, Martin Gonzalez T, Le Roux M, Azzaoui R, Midulla M, Haulon S (2014) Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair. Eur J Vasc Endovasc Surg 48(4):382–390
25.
Zurück zum Zitat Fetterly KA, Magnuson DJ, Tannahill GM, Hindal MD, Mathew V (2011) Effective use of radiation shields to minimize operator dose during invasive cardiology procedures. JACC Cardiovasc Interv 4(10):1133–1139PubMedCrossRef Fetterly KA, Magnuson DJ, Tannahill GM, Hindal MD, Mathew V (2011) Effective use of radiation shields to minimize operator dose during invasive cardiology procedures. JACC Cardiovasc Interv 4(10):1133–1139PubMedCrossRef
26.
Zurück zum Zitat Murphy JC, Darragh K, Walsh SJ, Hanratty CG (2011) Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures. Am J Cardiol 108(10):1408–1410PubMedCrossRef Murphy JC, Darragh K, Walsh SJ, Hanratty CG (2011) Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures. Am J Cardiol 108(10):1408–1410PubMedCrossRef
Metadaten
Titel
Occupational Radiation Exposure During Endovascular Aortic Repair
verfasst von
Anna M. Sailer
Geert Willem H. Schurink
Martine E. Bol
Michiel W. de Haan
Willem H. van Zwam
Joachim E. Wildberger
Cécile R. L. P. N. Jeukens
Publikationsdatum
01.08.2015
Verlag
Springer US
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 4/2015
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-014-1025-8

Weitere Artikel der Ausgabe 4/2015

CardioVascular and Interventional Radiology 4/2015 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.