Skip to main content
Erschienen in: CardioVascular and Interventional Radiology 6/2015

01.12.2015 | Clinical Investigation

Curved Needles in CT-Guided Fine Needle Biopsies of Abdominal and Retroperitoneal Small Lesions

verfasst von: Massimo De Filippo, Luca Saba, Enrica Rossi, Rita Nizzoli, Marcello Tiseo, Giuseppe Pedrazzi, Luca Brunese, Antonio Rotondo, Cristina Rossi

Erschienen in: CardioVascular and Interventional Radiology | Ausgabe 6/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To demonstrate the advantages of using curved needles in fine needle aspiration (FNA) with CT-guided, for analyzing abdominal and/or retroperitoneal small lesions which are impossible to reach with conventional non-surgical biopsy techniques, particularly in cases in which the cytology sample was not possible to obtain by means of US or CT guide with axial images.

Materials and Methods

An authorization for CT-guided FNA in patients with neoplasms is not required by the institutional review board of our Institute. From April 2012 to November 2014, the study included retrospectively 25 patients (16 M, 9 F) who underwent CT-guided FNA of abdominal and/or retroperitoneal small lesions (<30 mm), in which the ultrasound and axial CT scans were not reliable guides for the biopsy procedure because of the interposition of anatomical obstacles. Patients with suspected lymphomas or sarcomas, pediatric patients and patients with bleeding diathesis were excluded. Cytology reports were used for evaluating suitability.

Results

The biological material was considered to be suitable for cytological study, with a diagnostic value in all 25 cases, finding in particular: out of 23 neoplastic lesions (85 %), 21 were malignant (90.2 %) and 2 were benign (8 %). 2 out 25 were non-neoplastic benign lesions (8 %). No procedural complications arose in any of the cases (0 %).

Conclusion

Using curved needles, there is an effective improvement in CT-guided FNA of abdominal and retroperitoneal small lesions which are difficult to achieve with conventional CT or ultrasound guide.
Literatur
1.
Zurück zum Zitat Mehdi G, Maheshwari V, Afzal S, Ansari HA, Ahmad I. Image-guided fine-needle aspiration of retroperitoneal masses: the role of cytopathologist. J Cytol. 2013;30(1):36–41.PubMedCentralCrossRefPubMed Mehdi G, Maheshwari V, Afzal S, Ansari HA, Ahmad I. Image-guided fine-needle aspiration of retroperitoneal masses: the role of cytopathologist. J Cytol. 2013;30(1):36–41.PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Guo Z, Kurtycz DF, De Las Casas LE, Hoerl HD. Radiologically guided percutaneous fine-needle aspiration biopsy of pelvic and retroperitoneal masses: a retrospective study of 68 cases. Diagn Cytophathol. 2001;25(1):43–9.CrossRef Guo Z, Kurtycz DF, De Las Casas LE, Hoerl HD. Radiologically guided percutaneous fine-needle aspiration biopsy of pelvic and retroperitoneal masses: a retrospective study of 68 cases. Diagn Cytophathol. 2001;25(1):43–9.CrossRef
3.
Zurück zum Zitat Gupta S. New techniques in image-guided percutaneous biopsy. CardioVasc Interv Radiol. 2004;27(2):91–104.CrossRef Gupta S. New techniques in image-guided percutaneous biopsy. CardioVasc Interv Radiol. 2004;27(2):91–104.CrossRef
4.
Zurück zum Zitat Pedersen JF. Percutaneous puncuture guided by ultrasonic multitransducer scanning. J Clin Ultrasound. 1977;5(3):175–7.CrossRefPubMed Pedersen JF. Percutaneous puncuture guided by ultrasonic multitransducer scanning. J Clin Ultrasound. 1977;5(3):175–7.CrossRefPubMed
5.
Zurück zum Zitat Porter B, Karp W, Forsberg L. Percutaneous cytodiagnosis of abdominal masses by ultrasound guided fine needle aspiration biopsy. Acta Radiol Diagn (Stockh). 1981;22(6):663–8. Porter B, Karp W, Forsberg L. Percutaneous cytodiagnosis of abdominal masses by ultrasound guided fine needle aspiration biopsy. Acta Radiol Diagn (Stockh). 1981;22(6):663–8.
6.
Zurück zum Zitat Juul N, Torp-Pedersen S, Holm HH. Ultrasonically guided fine-needle aspiration biopsy of retroperitoneal mass lesions. Br J Radiol. 1984;57(673):43–6.CrossRefPubMed Juul N, Torp-Pedersen S, Holm HH. Ultrasonically guided fine-needle aspiration biopsy of retroperitoneal mass lesions. Br J Radiol. 1984;57(673):43–6.CrossRefPubMed
7.
Zurück zum Zitat Memel DS, Dodd GD, Esola CC. Efficacy of sonography as guidance tecnique for biopsy of abdominal, pelvic, and retroperitoneal lymphnodes. AJR Am J Roentgenol. 1996;167(4):957–62.CrossRefPubMed Memel DS, Dodd GD, Esola CC. Efficacy of sonography as guidance tecnique for biopsy of abdominal, pelvic, and retroperitoneal lymphnodes. AJR Am J Roentgenol. 1996;167(4):957–62.CrossRefPubMed
8.
Zurück zum Zitat Matalon TA, Silver B. US Guidance of Interventional Procedures. Radiology. 1990;174(1):43–7.CrossRefPubMed Matalon TA, Silver B. US Guidance of Interventional Procedures. Radiology. 1990;174(1):43–7.CrossRefPubMed
9.
Zurück zum Zitat Sundaram M, Wolverson MK, Heiberg E, Pilla T, Vas WG, Shields JB. Utility of CT-guided abdominal aspiration procedures. AJR Am J Roentgenol. 1982;139(6):1111–5.CrossRefPubMed Sundaram M, Wolverson MK, Heiberg E, Pilla T, Vas WG, Shields JB. Utility of CT-guided abdominal aspiration procedures. AJR Am J Roentgenol. 1982;139(6):1111–5.CrossRefPubMed
10.
Zurück zum Zitat Stattaus J, Kalkmann J, Kuehl H, et al. Diagnostic yield of computed tomography-guided coaxial core biopsy of undetermined masses in the free retroperitoneal space: single-center experience. Cardiovasc Intervent Radiol. 2008;31(5):919–25.CrossRefPubMed Stattaus J, Kalkmann J, Kuehl H, et al. Diagnostic yield of computed tomography-guided coaxial core biopsy of undetermined masses in the free retroperitoneal space: single-center experience. Cardiovasc Intervent Radiol. 2008;31(5):919–25.CrossRefPubMed
11.
Zurück zum Zitat Welch TJ, Sheedy PF, Johnson CD, Johnson CM, Stephens DH. CT-guided biopsy: prospective analysis of 1,000 procedures. Radiology. 1989;171(2):493–6.CrossRefPubMed Welch TJ, Sheedy PF, Johnson CD, Johnson CM, Stephens DH. CT-guided biopsy: prospective analysis of 1,000 procedures. Radiology. 1989;171(2):493–6.CrossRefPubMed
12.
Zurück zum Zitat De Filippo M, Onniboni M, Rusca M, Carbognani P, Ferrari L, Guazzi A, et al. Advantages of multi detector-row CT with multi planar reformation in guiding percutaneous lung biopsies. Radiol Med. 2008;113:945–53.CrossRefPubMed De Filippo M, Onniboni M, Rusca M, Carbognani P, Ferrari L, Guazzi A, et al. Advantages of multi detector-row CT with multi planar reformation in guiding percutaneous lung biopsies. Radiol Med. 2008;113:945–53.CrossRefPubMed
13.
Zurück zum Zitat De Filippo M, Gira F, Corradi D, Sverzellati N, Zompatori M, Rossi C. Benefits of 3D technique in guiding percutaneous retroperitoneal biopsies. Radiol Med. 2011;116(3):407–16.CrossRefPubMed De Filippo M, Gira F, Corradi D, Sverzellati N, Zompatori M, Rossi C. Benefits of 3D technique in guiding percutaneous retroperitoneal biopsies. Radiol Med. 2011;116(3):407–16.CrossRefPubMed
14.
Zurück zum Zitat Bandoh S, Fujita J, Toyo Y, et al. Diagnostic accuracy and safety of flexible bronchoscopy with multiplanar reconstruction images and ultrafast Papanicolaou stain: evaluating solitary pulmonary nodules. Chest. 2003;124:1985–92.CrossRefPubMed Bandoh S, Fujita J, Toyo Y, et al. Diagnostic accuracy and safety of flexible bronchoscopy with multiplanar reconstruction images and ultrafast Papanicolaou stain: evaluating solitary pulmonary nodules. Chest. 2003;124:1985–92.CrossRefPubMed
15.
Zurück zum Zitat Kimura T, Naka N, Minato Y, et al. Oblique approach of computed tomography guided needle biopsy using multi planar reconstruction image by multi detector-row CT in lung cancer. Eur J Radiol. 2004;52(2):206–11.CrossRefPubMed Kimura T, Naka N, Minato Y, et al. Oblique approach of computed tomography guided needle biopsy using multi planar reconstruction image by multi detector-row CT in lung cancer. Eur J Radiol. 2004;52(2):206–11.CrossRefPubMed
16.
Zurück zum Zitat Ohno Y, Hatabu H, Takenaka D, Imai M, Ohbayashi C, Sugimura K. Transthoracic CT-guided biopsy with multi planar reconstruction image improbe diagnostic accuracy of solitary pulmonary nodules. Eur J Radiol. 2004;51:160–8.CrossRefPubMed Ohno Y, Hatabu H, Takenaka D, Imai M, Ohbayashi C, Sugimura K. Transthoracic CT-guided biopsy with multi planar reconstruction image improbe diagnostic accuracy of solitary pulmonary nodules. Eur J Radiol. 2004;51:160–8.CrossRefPubMed
17.
Zurück zum Zitat De Filippo M, Onniboni M, Zompatori M. Double oblique approach for MDCT-guided needle biopsy or ablation in adrenal tumors using multi planar reconstruction. AJR. 2008;191:W74 0361-803X/08/1912-W74.CrossRef De Filippo M, Onniboni M, Zompatori M. Double oblique approach for MDCT-guided needle biopsy or ablation in adrenal tumors using multi planar reconstruction. AJR. 2008;191:W74 0361-803X/08/1912-W74.CrossRef
18.
Zurück zum Zitat Jeffrey RB Jr. Coaxial technique for CT-guided biopsy of deep retroperitoneal lymph nodes. Gastrointest Radiol. 1988;13(3):271–2.CrossRefPubMed Jeffrey RB Jr. Coaxial technique for CT-guided biopsy of deep retroperitoneal lymph nodes. Gastrointest Radiol. 1988;13(3):271–2.CrossRefPubMed
19.
Zurück zum Zitat De Filippo M, Saba L, Concari G, Nizzoli R, Ferrari L, Tiseo M, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med. 2013;118:1071–81.CrossRefPubMed De Filippo M, Saba L, Concari G, Nizzoli R, Ferrari L, Tiseo M, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med. 2013;118:1071–81.CrossRefPubMed
20.
Zurück zum Zitat Bossuyt Patrick M, Reitsma Johannes B, Bruns DE, et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD Initiative. Radiology. 2003;226:24–8.CrossRefPubMed Bossuyt Patrick M, Reitsma Johannes B, Bruns DE, et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD Initiative. Radiology. 2003;226:24–8.CrossRefPubMed
Metadaten
Titel
Curved Needles in CT-Guided Fine Needle Biopsies of Abdominal and Retroperitoneal Small Lesions
verfasst von
Massimo De Filippo
Luca Saba
Enrica Rossi
Rita Nizzoli
Marcello Tiseo
Giuseppe Pedrazzi
Luca Brunese
Antonio Rotondo
Cristina Rossi
Publikationsdatum
01.12.2015
Verlag
Springer US
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 6/2015
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-015-1107-2

Weitere Artikel der Ausgabe 6/2015

CardioVascular and Interventional Radiology 6/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.