Skip to main content
Erschienen in: European Radiology 8/2003

01.08.2003 | Cardiac

Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating

verfasst von: Tobias F. Jakobs, Bernd J. Wintersperger, Peter Herzog, Thomas Flohr, Christoph Suess, Andreas Knez, Maximilian F. Reiser, Christoph R. Becker

Erschienen in: European Radiology | Ausgabe 8/2003

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4×2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation (r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.
Literatur
1.
Zurück zum Zitat Friedewald ST, Wyngaarden JB, Smith LH (eds) (1988) Cecil's textbook of medicine, 18th edn. Saunders, Philadelphia, pp 179–183 Friedewald ST, Wyngaarden JB, Smith LH (eds) (1988) Cecil's textbook of medicine, 18th edn. Saunders, Philadelphia, pp 179–183
2.
Zurück zum Zitat Tunstall-Pedoe H, Kuulasmaa K, Mahonen M, Tolonen H, Ruokokoski E, Amouyel P (1999) Contribution of trends in survival and coronary-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA project populations. Monitoring trends and determinants in cardiovascular disease. Lancet 353:1547–1557PubMed Tunstall-Pedoe H, Kuulasmaa K, Mahonen M, Tolonen H, Ruokokoski E, Amouyel P (1999) Contribution of trends in survival and coronary-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA project populations. Monitoring trends and determinants in cardiovascular disease. Lancet 353:1547–1557PubMed
3.
Zurück zum Zitat O'Malley P, Taylor A, Gibbons R et al. (1999) Rationale and design of the prospective army coronary calcium (PACC) study: utility of electron-beam computed tomography as a screening test for coronary artery disease and as an intervention for risk factor modification amoung young, asymptomatic, active-duty United States Army personal. Am Heart J 137:932–941PubMed O'Malley P, Taylor A, Gibbons R et al. (1999) Rationale and design of the prospective army coronary calcium (PACC) study: utility of electron-beam computed tomography as a screening test for coronary artery disease and as an intervention for risk factor modification amoung young, asymptomatic, active-duty United States Army personal. Am Heart J 137:932–941PubMed
4.
Zurück zum Zitat National Institutes of Health (2000) NHLBI launches 10-year study on early detection of heart disease. National Heart, Lung and Blood Institute, http://www.nhlbi.nih.gov/new/press/sep14–00.htm National Institutes of Health (2000) NHLBI launches 10-year study on early detection of heart disease. National Heart, Lung and Blood Institute, http://​www.​nhlbi.​nih.​gov/​new/​press/​sep14–00.htm
5.
Zurück zum Zitat Laudon DA, Vukov LF, Breen JF, Rumberger JA, Wollan PC, Sheedy PF (1999) Use of electron-beam computed tomography in the evaluation of chest pain patients in the emergency department. Ann Emerg Med 33:15–21PubMed Laudon DA, Vukov LF, Breen JF, Rumberger JA, Wollan PC, Sheedy PF (1999) Use of electron-beam computed tomography in the evaluation of chest pain patients in the emergency department. Ann Emerg Med 33:15–21PubMed
6.
Zurück zum Zitat Wexler L, Brundage B, Crouse J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods and clinical implications. A statement for health professionals from the American Heart Association Writing Group. Circulation 94:1175–1192PubMed Wexler L, Brundage B, Crouse J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods and clinical implications. A statement for health professionals from the American Heart Association Writing Group. Circulation 94:1175–1192PubMed
7.
Zurück zum Zitat Callister TQ, Raggi P, Cooli B, Lippolis NJ, Russo DJ (1998) Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography. N Engl J Med 339:1972–1978PubMed Callister TQ, Raggi P, Cooli B, Lippolis NJ, Russo DJ (1998) Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography. N Engl J Med 339:1972–1978PubMed
8.
Zurück zum Zitat Becker C, Jakobs T, Aydemir S et al. (2000) Helical and single-slice conventional versus electron beam CT for quantification of coronary artery calcification. AJR 174:543–547PubMed Becker C, Jakobs T, Aydemir S et al. (2000) Helical and single-slice conventional versus electron beam CT for quantification of coronary artery calcification. AJR 174:543–547PubMed
9.
Zurück zum Zitat Becker C, Kleffel T, Crispin A et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. AJR 176:1295–1298 Becker C, Kleffel T, Crispin A et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. AJR 176:1295–1298
10.
Zurück zum Zitat Ohnesorge B, Flohr T, Becker CR et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed Ohnesorge B, Flohr T, Becker CR et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed
11.
Zurück zum Zitat Becker C, Schätzl M, Feist H et al. (1999) Assessment of the effective dose for routine protocols in conventional CT, electron beam CT and coronary angiography. RoFo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 170:90–104 Becker C, Schätzl M, Feist H et al. (1999) Assessment of the effective dose for routine protocols in conventional CT, electron beam CT and coronary angiography. RoFo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 170:90–104
12.
Zurück zum Zitat Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schröder S, Schöpf UJ, Crispin A, Klotz E, Reiser MF, Becker CR (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schröder S, Schöpf UJ, Crispin A, Klotz E, Reiser MF, Becker CR (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed
13.
Zurück zum Zitat Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217:430–435PubMed
14.
Zurück zum Zitat Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMed Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, Reiser MF (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMed
15.
Zurück zum Zitat Ohnesorge B, Flohr T, Becker CR, Kopp AF, Knez A, Reiser MF (2000) Dose evaluation and dose reduction strategies for ECG-gated multislice spiral CT of the heart. Radiology 217:487PubMed Ohnesorge B, Flohr T, Becker CR, Kopp AF, Knez A, Reiser MF (2000) Dose evaluation and dose reduction strategies for ECG-gated multislice spiral CT of the heart. Radiology 217:487PubMed
16.
Zurück zum Zitat Bongartz G, Golding SJ, Jurik AG, Leonardi M, van Meerten EvP, Geleijns J, Jessen KA, Panzer W, Shrimpton PC, Tosi G (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262 EN, http://www.drs.dk/guidelines/ct/quality/default.htm, ISBN 92-828-7478-8 Bongartz G, Golding SJ, Jurik AG, Leonardi M, van Meerten EvP, Geleijns J, Jessen KA, Panzer W, Shrimpton PC, Tosi G (1999) European guidelines on quality criteria for computed tomography. Report EUR 16262 EN, http://​www.​drs.​dk/​guidelines/​ct/​quality/​default.​htm, ISBN 92-828-7478-8
17.
Zurück zum Zitat Becker CR, Schoepf UJ, Reiser MF (2003) Coronary artery calcium scoring: medicine and politics. Eur Radiol 13:445–447PubMed Becker CR, Schoepf UJ, Reiser MF (2003) Coronary artery calcium scoring: medicine and politics. Eur Radiol 13:445–447PubMed
18.
Zurück zum Zitat Hong C, Bae KT et al. (2002) Coronary artery calcium measurement with multi-detector row CT: in vitro assessment of effect of radiation dose. Radiology 225:901–906PubMed Hong C, Bae KT et al. (2002) Coronary artery calcium measurement with multi-detector row CT: in vitro assessment of effect of radiation dose. Radiology 225:901–906PubMed
19.
Zurück zum Zitat Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed
20.
Zurück zum Zitat Klingenbeck K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multislice computed tomography: basics and applications. Eur J Radiol 31:110–124PubMed Klingenbeck K, Schaller S, Flohr T, Ohnesorge B, Kopp AF, Baum U (1999) Subsecond multislice computed tomography: basics and applications. Eur J Radiol 31:110–124PubMed
Metadaten
Titel
Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating
verfasst von
Tobias F. Jakobs
Bernd J. Wintersperger
Peter Herzog
Thomas Flohr
Christoph Suess
Andreas Knez
Maximilian F. Reiser
Christoph R. Becker
Publikationsdatum
01.08.2003
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 8/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1895-7

Weitere Artikel der Ausgabe 8/2003

European Radiology 8/2003 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.