01.12.2003 | Vascular–Interventional

Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance

verfasst von: Hicham T. Abada, Marc R. Sapoval, Jean-François Paul, Viviane de Maertelaer, Elie Mousseaux, Jean-Claude Gaux

Erschienen in: European Radiology | Ausgabe 12/2003

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to determine the variability of various measurement protocols for measurement of abdominal aortic aneurysm (AAA) and the clinical relevance of variability. Three radiologists performed computed tomographic angiography measurements of both the aorta and the largest portion of the aneurysm on selected axial slices. Then measurements of the largest portion of the aneurysm were performed on unselected axial slices, sagittal and coronal reformatted. Finally, aortic volume was calculated. Measurements and volume calculation were performed before and after endovascular repair and assessed: Part 1: interobserver variability for maximum anteroposterior (MAP) and maximum transverse (MTR) diameters on selected slices; part 2: interobserver variability for unselected slices considering MAP and MTR; part 3: interobserver variability considering maximum diameter in any direction (MAD); part 4: interobserver variability for sagittal (SAG) and coronal (COR) free curved multiplanar reformation (MPR); and part 5: volume calculations. We then determined which technique of measurement was the most clinically relevant for detecting changes in aneurysm size or aortic volume. Parts 1 and 2: interobserver variability was 4.1 mm for both MAP and MTR; part 3: interobserver variability was 7 mm for MAD; part 4: interobserver variability was 5.5 mm (COR) and 4.9 mm (SAG); part 5: interobserver variability for volume was 5.5 ml. A combination of MAP and MTR was the most useful for detecting aortic modification. Volume calculation was needed in only a few cases. We recommend avoiding MAD and MPR measurements and suggest instead measuring both maximum anteroposterior and maximum transverse diameters. If aneurysm size remains stable after endovascular repair, aneurysm volume should be measured.
Literatur
1.
Zurück zum Zitat Parodi JC, Criado FJ, Barone HD, Schonholz CS, Queral LA (1994) Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: a progress report. Ann Vasc Surg 8:523–529PubMed Parodi JC, Criado FJ, Barone HD, Schonholz CS, Queral LA (1994) Endoluminal aortic aneurysm repair using a balloon-expandable stent-graft device: a progress report. Ann Vasc Surg 8:523–529PubMed
2.
Zurück zum Zitat Blum U, Langer M, Spillner G et al. (1996) Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts. Radiol 198:25–31PubMed Blum U, Langer M, Spillner G et al. (1996) Abdominal aortic aneurysms: preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts. Radiol 198:25–31PubMed
3.
Zurück zum Zitat Doffner R, Thurner S, Polterauer P, Kretscnmer G, Lammer J (1997) Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention. Radiology 204:79–86PubMed Doffner R, Thurner S, Polterauer P, Kretscnmer G, Lammer J (1997) Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: complications and secondary radiologic intervention. Radiology 204:79–86PubMed
4.
Zurück zum Zitat Uflacker R, Robinson J (2001) Endovascular treatment of abdominal aortic aneurysm: a review. Eur Radiol 11:739–753CrossRefPubMed Uflacker R, Robinson J (2001) Endovascular treatment of abdominal aortic aneurysm: a review. Eur Radiol 11:739–753CrossRefPubMed
5.
Zurück zum Zitat Thomas PR, Shaw JC, Ashton HA, Kay DN, Scott RA (1994) Accuracy of ultrasound in a screening program for abdominal aortic aneurysms. J Med Screen 1:3–6PubMed Thomas PR, Shaw JC, Ashton HA, Kay DN, Scott RA (1994) Accuracy of ultrasound in a screening program for abdominal aortic aneurysms. J Med Screen 1:3–6PubMed
6.
Zurück zum Zitat Golzarian J, Dussaussois L, Struyven J (1999) Imaging of abdominal aortic aneurysm after endoluminal repair. Semin Ultrasound CT MR 20:16–24PubMed Golzarian J, Dussaussois L, Struyven J (1999) Imaging of abdominal aortic aneurysm after endoluminal repair. Semin Ultrasound CT MR 20:16–24PubMed
7.
Zurück zum Zitat Golzarian J, Struyven J (2001) Imaging of complications after endoluminal treatment of abdominal aortic aneurysm. Eur Radiol 11:2244–2251CrossRefPubMed Golzarian J, Struyven J (2001) Imaging of complications after endoluminal treatment of abdominal aortic aneurysm. Eur Radiol 11:2244–2251CrossRefPubMed
8.
Zurück zum Zitat Golzarian J, Dussaussois L, Abada HT et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR 171:329–331 Golzarian J, Dussaussois L, Abada HT et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR 171:329–331
9.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical notes: measurement error. Br Med J 313:744 Bland JM, Altman DG (1986) Statistical notes: measurement error. Br Med J 313:744
10.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 8:307–310
11.
Zurück zum Zitat White GH, May J, Petrasek P, Waugh R, Stephen M, Harris J (1999) Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovas Surg 6:308–315 White GH, May J, Petrasek P, Waugh R, Stephen M, Harris J (1999) Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovas Surg 6:308–315
12.
Zurück zum Zitat Jaakola P, Hippelainen M, Farin P, Rytkonen H, Kainulainen S, Partanen K (1996) Interobserver variability in measuring the dimensions of abdominal aorta: comparison of ultrasound and computed tomography. Eur J Vasc Endovasc Surg 12:230–237PubMed Jaakola P, Hippelainen M, Farin P, Rytkonen H, Kainulainen S, Partanen K (1996) Interobserver variability in measuring the dimensions of abdominal aorta: comparison of ultrasound and computed tomography. Eur J Vasc Endovasc Surg 12:230–237PubMed
13.
Zurück zum Zitat Lederle FA, Wilson SE, Johnson GR et al. (1995) Variability in measurement of abdominal aortic aneurysms. J Vasc Surg:945–952 Lederle FA, Wilson SE, Johnson GR et al. (1995) Variability in measurement of abdominal aortic aneurysms. J Vasc Surg:945–952
14.
Zurück zum Zitat Wever JJ, Blankensteijn, van Rijn, Broeders IA, Eikelboom, Mali WP (2000) Inter- and intraobserver variability of CT measurements obtained after endovascular repair. AJR 175:1279–1282 Wever JJ, Blankensteijn, van Rijn, Broeders IA, Eikelboom, Mali WP (2000) Inter- and intraobserver variability of CT measurements obtained after endovascular repair. AJR 175:1279–1282
15.
Zurück zum Zitat Wolf YG, Tillich M, Lee A, Fogarty TJ, Zarins CK, Rubin GD (2002) Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 36:305–309CrossRefPubMed Wolf YG, Tillich M, Lee A, Fogarty TJ, Zarins CK, Rubin GD (2002) Changes in aneurysm volume after endovascular repair of abdominal aortic aneurysm. J Vasc Surg 36:305–309CrossRefPubMed
16.
Zurück zum Zitat Shin H, Chavan, Witthus F et al. (2001) Precise determination of aortic length in patients with aortic stent-grafts: in-vivo evaluation of a thinning algorithm applied to CT angiography data. Eur Radiol 11:733–738CrossRefPubMed Shin H, Chavan, Witthus F et al. (2001) Precise determination of aortic length in patients with aortic stent-grafts: in-vivo evaluation of a thinning algorithm applied to CT angiography data. Eur Radiol 11:733–738CrossRefPubMed
17.
Zurück zum Zitat Raman R, Napel S, Beaulieu CF, Bain ES, Brooke JR, Rubin GD (2002) Automated generation of curved planar reformations from volume data: method and evaluation. Radiology 223:275–280PubMed Raman R, Napel S, Beaulieu CF, Bain ES, Brooke JR, Rubin GD (2002) Automated generation of curved planar reformations from volume data: method and evaluation. Radiology 223:275–280PubMed
Metadaten
Titel
Aneurysmal sizing after endovascular repair in patients with abdominal aortic aneurysm: interobserver variability of various measurement protocols and its clinical relevance
verfasst von
Hicham T. Abada
Marc R. Sapoval
Jean-François Paul
Viviane de Maertelaer
Elie Mousseaux
Jean-Claude Gaux
Publikationsdatum
01.12.2003
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1914-8

Weitere Artikel der Ausgabe 12/2003

European Radiology 12/2003 Zur Ausgabe

Letter to the Editor

Reply

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.